Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Curr Probl Cardiol ; 49(2): 102216, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37993008

RESUMEN

OBJECTIVE: This study seeks to identify the ideal dilution rate of a radiopaque product to optimize the visualization of coronary arteries and their branches within human cadaver hearts. The process involves obtaining images in the anatomy laboratory and subsequently constructing a three-dimensional model. MATERIALS AND METHODS: We utilized 30 human hearts fixed in 10 % formalin (9 females and 21 males) with a mean age of 79 ± 5 years. The initial experiment, involving the first four hearts (referred to as "group 1"), encountered difficulties in opacifying coronary arteries. In this phase, a probabilistic injection of 20 % Visipaque and 80 % latex, with coronary sinus ostium closure, was performed. The optimal mixture ratio was then determined as 33 % Visipaque and 66 % latex. Recognizing the need for on-site injection at the CT Scan table, this protocol was applied to the subsequent 11 hearts in "group 2." Closure of the coronary sinus was deemed unnecessary. The final 15 hearts, constituting "group 3," revealed that the injection should be gradual, maintaining controlled pressure between 120 and 150 mm Hg. Post-injection, hearts were scanned with the injected coronary arteries using an Optima 660 CT scanner. Two-dimensional images were acquired with parameters set at 64 × 0.625 mm, 100 kV, 300-400 mA, and a rotation of 0.5 s. Subsequently, 3D reconstruction was conducted using Advantage Workstation 4.7 (GE Healthcare) and volume rendering with Volume Viewer software, version 15. RESULTS: Significant differences in the percentage of opacified coronaries were observed among the three groups (p < 0.005). This variation underscores the learning curve and comprehension required before establishing a reliable method. Group 1 (N = 4) demonstrated minimal opacification, group 2 (N = 11) displayed partial opacification, while group 3 (N = 15) achieved 100 % opacification of coronary arteries. CONCLUSION: The successive experiments culminated in the development of a protocol for CT imaging, enabling accurate three-dimensional reconstruction of the normal anatomy of the main and secondary coronary arteries. Our work is grounded in a series of progressively refined and successful experiments.


Asunto(s)
Vasos Coronarios , Imagenología Tridimensional , Masculino , Femenino , Humanos , Anciano , Anciano de 80 o más Años , Vasos Coronarios/diagnóstico por imagen , Imagenología Tridimensional/métodos , Látex , Cadáver
2.
Front Cardiovasc Med ; 10: 1227589, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37781314

RESUMEN

Introduction: Calcification is a main cause of bioprosthetic heart valves failure. It may be promoted by the inflammation developed in the glutaraldehyde (GA)-fixed cusps of the bioprosthesis. We tested the hypothesis that antagonizing the C-X-C chemokines receptor 2 (CXCR2) may prevent the calcification of GA-fixed porcine aortic valves. Materiel and methods: Four-week-old Sprague Dawley males were transplanted with 2 aortic valve cusps isolated from independent pigs and implanted into the dorsal wall. Four groups of 6 rats were compared: rats transplanted with GA-free or GA-fixed cusps and rats transplanted with GA-fixed cusps and treated with 1 mg/kg/day SCH5217123 (a CXCR2 antagonist) intraperitoneally (IP) or subcutaneously (SC) around the xenograft, for 14 days. Then, rats underwent blood count before xenografts have been explanted for histology and biochemistry analyses. Results: A strong calcification of the xenografts was induced by GA pre-incubation. However, we observed a significant decrease in this effect in rats treated with SCH527123 IP or SC. Implantation of GA-fixed cusps was associated with a significant increase in the white blood cell count, an effect that was significantly prevented by SCH527123. In addition, the expression of the CD3, CD68 and CXCR2 markers was reduced in the GA-fixed cusps explanted from rats treated with SCH527123 as compared to those explanted from non-treated rats. Conclusion: The calcification of GA-fixed porcine aortic valve cusps implanted subcutaneously in rats was significantly prevented by antagonizing CXCR2 with SCH527123. This effect may partly result from an inhibition of the GA-induced infiltration of T-cells and macrophages into the xenograft.

3.
Front Cardiovasc Med ; 10: 1205770, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37701140

RESUMEN

Background/introduction: Currently, despite continued issues with durability ( 1), biological prosthetic valves are increasingly chosen over mechanical valves for surgical aortic valve replacement (SAVR) in adult patients of all ages, at least in Western countries. For younger patients, this choice means assuming the risks associated with a redo SAVR or valve-in-valve procedure. Purpose: To assess the use of mechanical vs. biological valve prostheses for SAVR relative to patient's age and implant time in a large population extracted from the French National Database EPICARD. Methods: Patients in EPICARD undergoing SAVR from 2007 to 2022 were included from 22 participating public or private centers chosen to represent a balanced representation of centre sizes and geographical discrepancies. Patients with associated pathology of the aorta (aneurysm or dissection) and requiring a vascular aortic prosthesis were excluded. Comparisons were made amongst centers, valve choice, implant date range, and patient age. Results: We considered 101,070 valvular heart disease patients and included 72,375 SAVR (mean age 71.4 ± 12.2 years). We observed a mechanical vs. biological prosthesis ratio (MBPR) of 0.14 for the overall population. Before 50 years old (y-o), MBPR was >1.3 (p < 0.001) while patients above 60 years-old received principally biological SAVR (p < 0.0001). Concerning patients between 50 and 60 years-old patients, MPVR was 1.04 (p = 0.03). Patients 50-60 years-old from the first and second study duration quartile (before August 2015) received preferentially mechanical SAVR (p < 0.001). We observed a shift towards more biological SAVR (p < 0.001) for patients from the third and fourth quartile to reach a MBPR at 0.43 during the last years of the series. Incidentally, simultaneous mitral valve replacement were more common in case of mechanical SAVR (p < 0.0001), while associated CABGs were more frequent in case of biological SAVR (p < 0.0001). Conclusion: In a large contemporary French patient population, real world practice showed a recent shift towards a lower age-threshold for biological SAVR as compared to what would suggest contemporary guidelines.

4.
Surg Radiol Anat ; 45(9): 1089-1095, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37452194

RESUMEN

OBJECTIVE: To study the anatomy and biometry of the radial artery and to report the implications of this study for daily practice in Cardiac Surgery. METHOD: Radial arteries from 45 human cadavers (28 males and 17 females, average age 79.2 (92) fixed in 10% formalin were dissected. The proximal and distal internal calibers and lengths of these radial arteries were measured. RESULTS: Our results showed the presence of a single radial artery variation in 2.3% of the entire sample (1.1% of the 90 dissected upper limbs). The distance between the epicondyle and the emergence of the radial artery was 32.4 (6.67) mm in men and 30.7 (9.00) mm in women, with an average of 31.8 (7.58) mm. For the right upper limb, the mean proximal internal caliber of the radial artery was 3.16 (0.56) mm and its mean distal internal caliber was 2.62 (0.66) mm. For the left upper limb, the mean proximal internal caliber of the radial artery was 3.17 (0.59) mm and its mean distal internal caliber was 2.64 (0.68) mm. The mean length of the left radial artery was 197.0 (17) mm. The mean length of the right radial artery was 201.0 (33) mm. CONCLUSION: It is very important to be aware of the possible anatomical variation of the radial artery. Despite its rarity, this knowledge may ensure a better safety and reliability of the harvesting technique for use as a graft.


Asunto(s)
Brazo , Arteria Radial , Masculino , Humanos , Femenino , Anciano , Arteria Radial/anatomía & histología , Reproducibilidad de los Resultados , Brazo/anatomía & histología , Cadáver , Biometría
5.
Cardiovasc Res ; 119(13): 2355-2367, 2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37517061

RESUMEN

AIMS: Inflammatory cytokines play a critical role in the progression of calcific aortic valve disease (CAVD), for which there is currently no pharmacological treatment. The aim of this study was to test the hypothesis that interleukin-8 (IL-8), known to be involved in arterial calcification, also promotes aortic valve calcification (AVC) and to evaluate whether pharmacologically blocking the IL-8 receptor, CXC motif chemokine receptor 2 (CXCR2), could be effective in preventing AVC progression. METHODS AND RESULTS: A cohort of 195 patients (median age 73, 74% men) diagnosed with aortic valve stenosis (severe in 16.9% of cases) were prospectively followed by CT for a median time of 2.6 years. A Cox proportional hazards regression analysis indicated that baseline IL-8 serum concentrations were associated with rapid progression of AVC, defined as an annualized change in the calcification score by CT ≥ 110 AU/year, after adjustment for age, gender, bicuspid anatomy, and baseline disease severity. In vitro, exposure of primary human aortic valvular interstitial cells (hVICs) to 15 pg/mL IL-8 induced a two-fold increase in inorganic phosphate (Pi)-induced calcification. IL-8 promoted NFκB pathway activation, MMP-12 expression, and elastin degradation in hVICs exposed to Pi. These effects were prevented by SCH527123, an antagonist of CXCR2. The expression of CXCR2 was confirmed in hVICs and samples of aortic valves isolated from patients with CAVD, in which the receptor was mainly found in calcified areas, along with MMP-12 and a degraded form of elastin. Finally, in a rat model of chronic kidney disease-associated CAVD, SCH527123 treatment (1 mg/kg/day given orally for 11 weeks) limited the decrease in aortic cusp separation, the increase in maximal velocity of the transaortic jet, and the increase in aortic mean pressure gradient measured by echocardiography, effects that were associated with a reduction in hydroxyapatite deposition and MMP-12 expression in the aortic valves. CONCLUSION: Overall, these results highlight, for the first time, a significant role for IL-8 in the progression of CAVD by promoting calcification via a CXCR2- and MMP-12-dependent mechanism that leads to elastin degradation, and identify CXCR2 as a promising therapeutic target for the treatment of CAVD.

6.
J Cardiothorac Surg ; 18(1): 141, 2023 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-37060017

RESUMEN

OBJECTIVE: Most mitral valve repair techniques provide excellent surgical results by removing regurgitation, but all of these techniques simultaneously reduce posterior valve mobility. A comprehensive biometric study of the mitral valve apparatus will provide landmarks that would help improve this posterior valve mobility. MATERIALS AND METHODS: Thirty one (31) human hearts have been studied, from 14 women and 17 men. The characteristics of the studied sample were analyzed descriptively. The difference in means of the variables between women and men were tested using a Student t test. Correlations between the different measures were determined by simple regression analysis. Mean values are shown with ± 1 standard deviation and the limit of significance was set at 0.05. RESULTS: The mean weight of the hearts was 275.3 ± 2.4 g. The anteroposterior diameter of the mitral annulus was 29.3 ± 1.22 mm, the intertrigonal distance was 25.2 ± 3.50 mm and the anterior leaflet to posterior leaflet ratio was 1.9 ± 0.10, the length of the chordae A2 = 19.4 ± 1.15 mm and P2 = 14.5 ± 0.85 mm. The length of the anterior papillary muscle averaged 30.9 ± 7.20 mm and that of the posterior one 30.0 ± 8.75 mm. The comparison of the different values measured between women and men showed no statistically significant difference (p > 0.05). There was no correlation between these different measured values (p > 0.05). CONCLUSION: A perfect knowledge of anatomy and biometry is therefore essential to offer alternative techniques that reproduce the real anatomy and physiology with a complete reconstruction of the mitral valve.


Asunto(s)
Biometría , Válvula Mitral , Válvula Mitral/anatomía & histología , Válvula Mitral/cirugía , Humanos , Masculino , Femenino , Músculos Papilares/anatomía & histología , Procedimientos Quirúrgicos Cardíacos , Corazón/anatomía & histología , Factores Sexuales
7.
Eur J Cardiothorac Surg ; 60(1): 191-193, 2021 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-33367561

RESUMEN

Infections of frozen elephant trunk hybrid prosthesis (HP) are not well documented in the literature and their management is not standardized yet. We report herein the case of a 59-year-old patient who benefited from a Thoraflex™ HP aortic arch replacement for an acute type A aortic dissection. He presented a year later with a Staphylococcus aureus infection of the proximal part of this prosthesis. We performed a replacement of the proximal compound of the HP accompanied by a complete debranching of the 3 supra-aortic vessels with an inter-carotidal retro-oesophageal bypass. As we left in situ the endovascular graft within the descending aorta, a life-long antibiotic therapy was introduced. The postoperative follow-up was uneventful, and the patient discharged home 2 weeks after his surgery. As an alternative to a more radical redo surgery with major risk, a hybrid medical and surgical treatment of infected frozen elephant trunk could be considered.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Reimplantación , Stents , Resultado del Tratamiento
8.
Artículo en Inglés | MEDLINE | ID: mdl-33141214

RESUMEN

OBJECTIVES: Our goal was to study the immediate outcome after an emergency frozen elephant trunk procedure with a Thoraflex™ Hybrid prosthesis (THP) in patients included in the EPI-Flex national registry and operated on in 21 French centres. METHODS: All patients operated on in France between April 2016 and April 2019 for acute aortic syndromes and who had an frozen elephant trunk procedure with a THP were included in the study. The main end point was in-hospital mortality. The secondary end point was neuromorbidity, including paraplegia. The evolution of the main end point was monitored using a variable life-adjusted display graph with cumulative sum derivatives in order to stop inclusions in case the observed mortality became out of range compared to an expected mortality between 15% and 20%. RESULTS: Enrolment ended on the scheduled date and included 109 patients. Most cases (54%) were performed at 3 centres, where more than 10 THP each were implanted (10-26). The observed mortality in the large-volume centres (22%) was comparable to that observed in the low-volume centres (20%). The individually risk-adjusted cumulative sum revealed that observed in-hospital mortality was statistically in line with that predicted by the log EuroSCORE. Analysis of the secondary end point revealed 8% cases of paraplegia, all of which appeared after treatment of the thoracic type A aortic dissection. CONCLUSIONS: In France, THP for emergency frozen elephant trunk surgery outside high-volume centres did not result in excessive in-hospital deaths. However, a word of caution must be expressed regarding the prevention of medullar ischaemia even in emergency aortic surgery.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...