Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 93(9): 093527, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36182470

RESUMEN

Capacitive plasma pickup is a well-known and difficult problem for plasma-facing edge diagnostics. This problem must be addressed to ensure an accurate and robust interpretation of the real signal measurements vs noise. The Faraday cup fast ion loss detector array of the Joint European Torus (JET) is particularly prone to this issue and can be used as a testbed to prototype solutions. The issue of separation and distinction between warranted fast ion signal and electromagnetic plasma noise has traditionally been solved with hardware modifications, but a more versatile post-processing approach is of great interest. This work presents post-processing techniques to characterize the signal noise. While hardware changes and advancements may be limited, the combination with post-processing procedures allows for more rapid and robust analysis of measurements. The characterization of plasma pickup noise is examined for alpha losses in a discharge from JET's tritium campaign. In addition to highlighting the post-processing methodology, the spatial sensitivity of the detector array is also examined, which presents significant advantages for the physical interpretation of fast ion losses.

2.
Phys Rev Lett ; 88(14): 145001, 2002 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-11955153

RESUMEN

Joint European Torus discharges which demonstrate the critical role the safety factor profile, q, can play in the formation of internal transport barriers (ITB) are examined. In these discharges, the target parameters, including the E x B flows, were kept virtually the same, except for the q profile. In a discharge with a nonmonotonic q, an ITB was triggered whereas a discharge with monotone q made no such transition. Thus, there is strong evidence that the q profile was the critical factor for the triggering of an ITB. Possible interpretations of this finding are discussed.

3.
Phys Rev Lett ; 88(14): 145004, 2002 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-11955156

RESUMEN

Quasistationary operation has been achieved on the Joint European Torus tokamak in internal-transport-barrier (ITB) scenarios, with the discharge time limited only by plant constraints. Full current drive was obtained over all the high performance phase by using lower hybrid current drive. For the first time feedback control on the total pressure and on the electron temperature profile was implemented by using, respectively, the neutral beams and the ion-cyclotron waves. Although impurity accumulation could be a problem in steady state ITBs, these experiments bring some elements to answer to it.

4.
Phys Rev Lett ; 87(11): 115001, 2001 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-11531529

RESUMEN

Simultaneous current ramping and application of lower hybrid heating and current drive (LHCD) have produced a region with zero current density within measurement errors in the core ( r/a< or =0.2) of JET tokamak optimized shear discharges. The reduction of core current density is consistent with a simple physical explanation and numerical simulations of radial current diffusion including the effects of LHCD. However, the core current density is clamped at zero, indicating the existence of a physical mechanism which prevents it from becoming negative.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...