Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38716699

RESUMEN

N-nitrosamines (NAs) are prevalent mutagenic impurities in various consumer products. Their discovery in valsartan-containing medicines in 2018 prompted global regulatory agencies to set guidelines on their presence and permissible levels in pharmaceuticals. In order to determine the NAs content in medicines, efficient and sensitive analytical methods have been developed based on mass spectrometry techniques. Direct analysis in real time-mass spectrometry (DART-MS) has emerged as a prominent ambient ionization technique for pharmaceutical analysis due to its high-throughput capability, simplicity, and minimal sample preparation requirements. Thus, in this study DART-MS was evaluated for the screening and quantification of NAs in medicines. DART-MS analyses were conducted in positive ion mode, for both direct tablet analysis and solution analysis. The analytical performance was evaluated regarding linearity, precision, accuracy, limits of detection, and quantification. The DART-MS proved to be suitable for the determination of NAs in medicines, whether through direct tablet analysis or solution analysis. The analytical performance demonstrated linearity in the range from 1.00 to 200.00 ng mL-1, limits of quantification about 1.00 ng mL-1, precision and accuracy lower than 15%, and no significant matrix effect for six drug-related NAs. In conclusion, the DART-MS technique demonstrated to be an alternative method to determine NAs in medicines, aligning with the principles of green chemistry.

2.
Bioanalysis ; 14(15): 1039-1050, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36125034

RESUMEN

Aims: To validate an SPE-ultra-HPLC-MS/MS method for thalidomide (THD) measurement in dried plasma spot (DPS). Methods: Extraction included acetonitrile/water clean-up and online SPE. The LOD, LLOQ, linearity, precision, accuracy, recovery, matrix effect, process efficiency, carryover, stability, drug interference and dilution integrity were assessed. Results: The method was linear from 50 to 2000 ng/ml with a LOD of 20 ng/ml and LLOQ of 50 ng/ml. The coefficient of variation for precision was 0.4-7.9% for intra-assay and 1.3-8.9% for interassay, and accuracy was 81.4-97.1%. Adequate matrix effect (100.6-107.0%), recovery (88.7-105.0%) and process efficiency (91.3-109.3%) were registered. DPS was stable for 14 days at room temperature and 45°C ,and for 4 months at -80°C. The method was applied to quantify THD in both wet plasma and DPS from patients with cutaneous lupus receiving THD treatment. The difference between THD wet plasma and DPS concentration was <15%. Conclusion: The method is suitable to quantify THD in DPS.


Asunto(s)
Monitoreo de Drogas , Espectrometría de Masas en Tándem , Acetonitrilos , Cromatografía Líquida de Alta Presión/métodos , Pruebas con Sangre Seca/métodos , Monitoreo de Drogas/métodos , Humanos , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem/métodos , Talidomida , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...