Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Radiat Oncol ; 14(1): 80, 2019 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-31088490

RESUMEN

BACKGROUND: For radiotherapy of abdominal cancer, four-dimensional magnetic resonance imaging (4DMRI) is desirable for tumor definition and the assessment of tumor and organ motion. However, irregular breathing gives rise to image artifacts. We developed a outlier rejection strategy resulting in a 4DMRI with reduced image artifacts in the presence of irregular breathing. METHODS: We obtained 2D T2-weighted single-shot turbo spin echo images, with an interleaved 1D navigator acquisition to obtain the respiratory signal during free breathing imaging in 2 patients and 12 healthy volunteers. Prior to binning, upper and lower inclusion thresholds were chosen such that 95% of the acquired images were included, while minimizing the distance between the thresholds (inclusion range (IR)). We compared our strategy (Min95) with three commonly applied strategies: phase binning with all images included (Phase), amplitude binning with all images included (MaxIE), and amplitude binning with the thresholds set as the mean end-inhale and mean end-exhale diaphragm positions (MeanIE). We compared 4DMRI quality based on: Data included (DI); percentage of images remaining after outlier rejection. Reconstruction completeness (RC); percentage of bin-slice combinations containing at least one image after binning. Intra-bin variation (IBV); interquartile range of the diaphragm position within the bin-slice combination, averaged over three central slices and ten respiratory bins. IR. Image smoothness (S); quantified by fitting a parabola to the diaphragm profile in a sagittal plane of the reconstructed 4DMRI. A two-sided Wilcoxon's signed-rank test was used to test for significance in differences between the Min95 strategy and the Phase, MaxIE, and MeanIE strategies. RESULTS: Based on the fourteen subjects, the Min95 binning strategy outperformed the other strategies with a mean RC of 95.5%, mean IBV of 1.6 mm, mean IR of 15.1 mm and a mean S of 0.90. The Phase strategy showed a poor mean IBV of 6.2 mm and the MaxIE strategy showed a poor mean RC of 85.6%, resulting in image artifacts (mean S of 0.76). The MeanIE strategy demonstrated a mean DI of 85.6%. CONCLUSIONS: Our Min95 reconstruction strategy resulted in a 4DMRI with less artifacts and more precise diaphragm position reconstruction compared to the other strategies. TRIAL REGISTRATION: Volunteers: protocol W15_373#16.007; patients: protocol NL47713.018.14.


Asunto(s)
Neoplasias Esofágicas/diagnóstico por imagen , Tomografía Computarizada Cuatridimensional/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Respiración , Neoplasias Gástricas/diagnóstico por imagen , Adulto , Anciano de 80 o más Años , Algoritmos , Artefactos , Estudios de Casos y Controles , Estudios de Cohortes , Neoplasias Esofágicas/patología , Neoplasias Esofágicas/radioterapia , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Neoplasias Pancreáticas/patología , Neoplasias Pancreáticas/radioterapia , Fantasmas de Imagen , Pronóstico , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Neoplasias Gástricas/patología , Neoplasias Gástricas/radioterapia
2.
Brachytherapy ; 15(1): 118-26, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26614236

RESUMEN

PURPOSE: To quantify distortions on MR images of the Utrecht interstitial CT/MR applicator at a field strength of 3T using an MRI-only method. MATERIALS AND METHODS: An MR-compatible phantom suspending the applicator in water was built and imaged on a Philips Ingenia 3T MRI scanner. A map of the magnetic field (B0) was calculated from multiecho images and used to quantify the field inhomogeneity. The expected displacements of the applicator could be quantified using the measured field inhomogeneity and sequence bandwidth. Additionally, two scans were acquired using opposing readout gradients. These scans were rigidly matched and their displacement was compared with the expected displacements from the B0 map. These same methods were applied in 4 patients. By rigid matching of the scans acquired with opposing readout direction the applicator displacement due to image distortion from B0 inhomogeneity as well as patient movement and organ deformation was determined. RESULTS: According to the B0 map, the displacement on the intrauterine device of the plastic brachytherapy applicator was <0.4 mm for both the phantom and patients. Displacements obtained by the opposing readout method were ≤0.8 mm for each patient with a mean ± SD over the patients of 0.3 ± 0.1 mm. CONCLUSION: The results of our study indicate that the B0 method agrees with the opposing readout method. Displacements caused by magnetic field inhomogeneity on 3T MRI were small compared with displacements due to patient movement and organ deformation.


Asunto(s)
Braquiterapia , Imagen por Resonancia Magnética , Radioterapia Guiada por Imagen , Tomografía Computarizada por Rayos X , Neoplasias del Cuello Uterino/radioterapia , Braquiterapia/instrumentación , Femenino , Humanos , Fantasmas de Imagen , Incertidumbre
3.
J Appl Microbiol ; 118(5): 1191-8, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25580664

RESUMEN

AIM: To determine the presence of the T6SS in Campylobacter jejuni from diverse sources. METHODS AND RESULTS: The recently identified type VI secretion system (T6SS) is a bacterial injection machinery that plays a role in virulence, symbiosis, bacterial interactions and environmental stress responses. This system has been recently discovered in the major enteric pathogen Camp. jejuni. In this study, we used multiplex PCR (mPCR), based on conserved genetic markers of the T6SS, to screen 366 Pakistani Camp. jejuni isolates from humans, poultry, cattle, wildlife or waste-water sources. We identified the T6SS in isolates from all of these sources except humans. The overall prevalence of the T6SS among the isolates was 17/366 (4·6%) and the T6SS positive isolates clustered into four different groups. Transcription of the T6SS genes, determined using RT-PCR, was observed in bacteria cultured at 37 or 42°C but not in 37°C cultures adjusted to pH3. CONCLUSIONS: Campylobacter jejuni isolates harbouring T6SS markers genes were identified in livestock and non-livestock sources but in this study we did not identify human diarrhoeal isolates which possessed the T6SS. We demonstrated down-regulation of T6SS in an acidic environment. SIGNIFICANCE AND IMPACT OF THE STUDY: This study questions the role of the T6SS in human diarrhoeal disease. Moreover this study did not identify a clear association of Camp. jejuni isolates harbouring T6SS with any of the niches tested. Our study highlights the need to establish the role of the T6SS in environmental survival or virulence.


Asunto(s)
Proteínas Bacterianas/genética , Infecciones por Campylobacter/microbiología , Infecciones por Campylobacter/veterinaria , Campylobacter jejuni/genética , Sistemas de Secreción Tipo VI/genética , Animales , Animales Salvajes/microbiología , Proteínas Bacterianas/metabolismo , Campylobacter jejuni/clasificación , Campylobacter jejuni/aislamiento & purificación , Campylobacter jejuni/patogenicidad , Bovinos , Regulación hacia Abajo , Marcadores Genéticos , Humanos , Ganado/microbiología , Aves de Corral/microbiología , Sistemas de Secreción Tipo VI/metabolismo , Virulencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA