Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 12(14)2023 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-37510822

RESUMEN

BACKGROUND: There is a paucity of reporting outcomes of complex aortic aneurysm treatment such as juxtarenal abdominal aortic aneurysms, where additional techniques to preserve renal artery perfusion are required. METHODS: Retrospective analysis of consecutive patients who underwent emergent and elective aortic repair with fenestrated PMEGs between March 2019 and January 2023. Endpoints were technical success, reinterventions, secondary reinterventions and target vessel patency. RESULTS: Forty-seven target vessels in 37 patients (23 male, median age 75 years) were targeted, of which 44 were renal arteries (RAs) with a mean diameter of 5.4 ± 1.0 mm. Thirteen were accessory RAs and six had a diameter ≤ 4 mm. Technical success rate was 87% overall; 97% for main and 62% for accessory RAs respectively. Target vessel patency and freedom from secondary reintervention was 100% and 97% at 30 days and 96% and 91% at one year, respectively. There was no 30-day mortality. CONCLUSION: Fenestrated physician-modified endografts are safe and effective for the treatment of patients with juxtarenal abdominal aortic aneurysms when incorporating main renal arteries. Limited technical success may be expected when targeting accessory renal arteries, especially when small in diameter. Long-term follow-up is needed to confirm durability of PMEGs for renal artery preservation.

2.
J Endovasc Ther ; : 15266028231173311, 2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37191262

RESUMEN

PURPOSE: We describe the feasibility and early results of a novel endovascular approach with a surgeon-modified fenestrated iliac stent graft to preserve pelvic perfusion in patients with iliac aneurysms not suitable for iliac branch devices (IBDs). TECHNIQUE: Seven high-risk patients, median age 76 years (range 63-83), with a complex aortoiliac anatomy with contraindications for commercially available IBDs were treated with a novel surgeon-modified fenestrated iliac stent graft between August 2020 and November 2021. The modified device was built using an iliac limb stent graft (Endurant II Stent Graft; Medtronic), which was partially deployed, surgically fenestrated with a scalpel, reinforced, re-sheathed, and inserted via femoral access. The internal iliac artery was cannulated and bridged with a covered stent. Technical success rate was 100%. After a median follow-up period of 10 months, there was 1 type II endoleak and no migrations, stent fractures, or loss of device integrity. One iliac limb occlusion occurred after 7 months, which needed a secondary endovascular intervention, restoring patency. CONCLUSION: Surgeon-modified fenestrated iliac stent graft is feasible and might be used as an alternative in patients with a complex iliac anatomy not suitable to commercially available IBDs. Long-term follow-up is needed to evaluate stent graft patency and potential complications. CLINICAL IMPACT: Surgeon modified fenetrated iliac stent grafts might be a promising alternative to iliac branch devices, extending endovascular solutions to a broader patient population with complex aorto-iliac anatomies preserving antegrade internal iliac artery perfusion. It is possible to treat small iliac bifurcations and large angulations of the iliac bifurcation safely and there is no need for a contralateral or upper-extremity access.

3.
J Endovasc Ther ; 28(6): 871-877, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34190634

RESUMEN

PURPOSE: To describe the use of large-diameter balloon-expandable stent-grafts (BeGraft aortic stent-graft, Bentley InnoMed GmbH, Hechingen, Germany) in the treatment of infrarenal penetrating aortic ulcer (iPAU). MATERIALS AND METHODS: Retrospective analysis of patients undergoing endovascular treatment with the BeGraft aortic stent-graft in 8 European centers from January 2017 to October 2020. Demographics, perioperative data, and midterm outcomes were collected. Endpoints of the study were technical feasibility, early mortality, and morbidity. RESULTS: A total of 40 patients were included. The mean age was 73.9±7.05 years and 63.2% were male. Indications for treatment included size and morphology (65%), presence of symptoms (29.5%), and contained ruptures (5.5%). Urgent treatment was performed in 5% of cases. Technical success was 97.5%. Median operation time was 58 minutes (19-170 minutes), with 27.5% of patients having additional procedures during the main intervention (1 additional repair with a C-TAG (W.L. Gore & Associates, Inc, Flagstaff, AZ, USA) thoracic endoprosthesis, 5 covered endovascular reconstruction of aortic bifurcation procedures, 3 extensions with proximal cuffs, and 2 percutaneous angioplasties of the common iliac arteries). Percutaneous femoral access was used in 72.5%, while groin cut-down was performed in 27.5%. Repair was successful with only 1 stent in 45% of cases, while 37.5% required 2 stents and nearly 17.5% required 3/4 stent-grafts. The 30-day mortality was 0%, with a 2.5% reintervention rate (1 patient required evacuation of an intra-abdominal hematoma). Median follow-up was 13.9 months (2-39 months), during which no vascular-related reinterventions or deaths were reported. In 4 patients, a type II endoleak was observed. No cases of graft migration, thrombosis, or stent-fracture were observed. CONCLUSIONS: The treatment of iPAU with the BeGraft aortic stent-graft in a selective patient group is feasible with low rate of perioperative morbidity and mortality. Balloon-expandable stent-grafts offer the option to repair iPAUs with a shorter coverage of the aorta using low-profile sheath, that enables treatment in the presence of calcified access vessels and small diameter aortic bifurcations.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Anciano de 80 o más Años , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Stents , Resultado del Tratamiento , Úlcera/diagnóstico por imagen , Úlcera/cirugía
4.
Angiology ; 69(8): 686-691, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29334754

RESUMEN

The predictive value of the neutrophil to lymphocyte ratio (NLR) has been demonstrated in several cardiovascular diseases. The aim of our study was to investigate the association between the preoperative NLR and aneurysm characteristics as well as 30-day postoperative morbidity and mortality in patients with thoracic aortic aneurysm (TAA) undergoing aortic surgical repair. Consecutive patients (n = 75) with TAA were retrospectively included over a 10-year period. Clinical characteristics, aneurysm characteristics, and 30-day postoperative outcome were recorded. The median age of patients was 71 (67-80) years. The median preoperative NLR was 3.5 (2.3-5.8). The proportion of asymptomatic TAA was significantly lower in patients with an NLR > 3.5 compared with those with an NLR < 3.5 (52.6% vs 75.7%; P = .054). The proportion of patients with pain or with ruptured TAA was significantly higher in patients with an NLR > 3.5 compared with those with NLR < 3.5 (42.1% vs 16.2%; P = .022 and 26.3% vs 2.7%; P = .007, respectively). No significant difference was observed regarding the 30-day overall postoperative mortality and morbidity. The preoperative NLR did not correlate with TAA diameter. A high preoperative NLR is significantly associated with symptomatic and ruptured TAA, suggesting a potential interest as a marker and/or player in the disease.


Asunto(s)
Aneurisma de la Aorta Torácica/sangre , Rotura de la Aorta/sangre , Linfocitos , Neutrófilos , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Torácica/mortalidad , Aneurisma de la Aorta Torácica/cirugía , Rotura de la Aorta/mortalidad , Rotura de la Aorta/cirugía , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
5.
Chirurgia (Bucur) ; 111(4): 337-9, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27604672

RESUMEN

We present the case of a 75-year-old patient with asymptomatic gastro-duodenal artery aneurism (GAA) that was coiled through the left femoral artery. The gastro-duodenal artery (GDA) was then embolized. Following the intervention, the patient'™s left foot became cold. A sub-acute ischemia caused by a stenotic effect in the left external iliac artery and by lower limb embolic phenomena caused by the introductor, was diagnosed. A thromboembolectomy of the popliteal, anterior and posterior tibial and peroneal arteries was performed with a Fogarty catheter with good results. Aneurisms of the GDA are rare. Rupture is a severe and unpredictable complication that complicates management and darkens prognosis. Though endovascular treatment for splanchnic aneurisms are used more and more often and offers numerous advantages compared to surgery, it is not without risk. A multidisciplinary approach with careful collaboration between the surgeon and the radiologist is recommended. Abbreviattions: GAA: gastro-duodenal artery aneurism, GDA: gastro-duodenal artery.


Asunto(s)
Aneurisma/terapia , Cateterismo Periférico/efectos adversos , Duodeno/irrigación sanguínea , Embolectomía , Isquemia/cirugía , Estómago/irrigación sanguínea , Anciano , Cateterismo Periférico/métodos , Embolectomía/métodos , Arteria Femoral/cirugía , Humanos , Arteria Ilíaca/cirugía , Isquemia/etiología , Masculino , Arteria Poplítea/cirugía , Circulación Esplácnica , Resultado del Tratamiento
6.
Basic Res Cardiol ; 107(6): 298, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22961595

RESUMEN

Systolic function is often evaluated by measuring ejection fraction and its preservation is often assimilated with the lack of impairment of systolic left ventricular (LV) function. Considering the left ventricle as a muscular pump, we explored LV function during chronic hypertension independently of increased afterload conditions. Fourteen conscious and chronically instrumented pigs received continuous infusion of either angiotensin II (n = 8) or saline (n = 6) during 28 days. Hemodynamic recordings were regularly performed in the presence and 1 h after stopping angiotensin II infusion to evaluate intrinsic LV function. Throughout the protocol, the mean arterial pressure steadily increased by 55 ± 4 mmHg in angiotensin II-treated animals. There were no significant changes in stroke volume, LV fractional shortening or LV wall thickening, indicating the lack of alterations in LV ejection. In contrast, we observed maladaptive changes with (1) the lack of reduction in isovolumic contraction and relaxation durations with heart rate increases, (2) abnormally blunted isovolumic contraction and relaxation responses to dobutamine and (3) a linear correlation between isovolumic contraction and relaxation durations. None of these changes were observed in saline-infused animals. In conclusion, we provide evidence of impaired LV function with concomitant isovolumic contraction and relaxation abnormalities during chronic hypertension while ejection remains preserved and no sign of heart failure is present. The evaluation under unloaded conditions shows intrinsic LV abnormalities.


Asunto(s)
Hipertensión/fisiopatología , Función Ventricular Izquierda , Angiotensina II , Animales , Diástole , Femenino , Hemodinámica , Hipertrofia Ventricular Izquierda/inducido químicamente , Contracción Miocárdica , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...