Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 161
Filtrar
1.
Can J Neurol Sci ; : 1-2, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38465649
5.
Int Ophthalmol ; 43(7): 2493-2501, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36905461

RESUMEN

PURPOSE: To evaluate the effects of different programmed optical zones (POZs) on achieved corneal refractive power (CRP) with myopic astigmatism after small incision lenticule extraction (SMILE). METHODS: In total, 113 patients (113 eyes) were included in this retrospective study. The eyes were divided into two groups according to POZ: group A (6.5, 6.6, and 6.7 mm, n = 59) and group B (6.8, 6.9, and 7.0 mm, n = 54). Fourier vector analysis was applied to evaluate the error values between the attempted and achieved corneal refractive power (CRP). Alpins vector analysis was used to calculate surgically induced astigmatism (SIA), difference vector (DV), magnitude of error (ME), and astigmatism correction index (ACI). Multivariate regression analysis was performed to assess potential factors associated with the error values. RESULTS: The error values in the group with large POZ were closer to zero, and significantly associated with the POZ at 2 and 4 mm of the cornea (ß = - 0.50, 95% confidence interval [CI] [- 0.80, - 0.20]; ß = - 0.37, 95% CI [- 0.63, - 0.10], P < 0.05, respectively). For the correction of astigmatism, the values of SIA, ME, and ACI were lower in group B than in group A (P < 0.05). The fitting curves between TIA and SIA were y = 0.83x + 0.19 (R2 = 0.84) and y = 1.05x + 0.04 (R2 = 0.90), respectively. CONCLUSIONS: Smaller POZs resulted in higher error values between the achieved- and attempted-CRP in the SMILE procedure, which should be considered when performing surgery.


Asunto(s)
Astigmatismo , Cirugía Laser de Córnea , Miopía , Humanos , Astigmatismo/diagnóstico , Astigmatismo/etiología , Astigmatismo/cirugía , Refracción Ocular , Agudeza Visual , Estudios Retrospectivos , Miopía/cirugía , Córnea/cirugía , Sustancia Propia/cirugía , Láseres de Excímeros/uso terapéutico , Cirugía Laser de Córnea/efectos adversos , Cirugía Laser de Córnea/métodos
6.
Front Immunol ; 14: 1063069, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36798135

RESUMEN

Purpose: We aim to investigate the effect of sustained hyperglycemia on corneal epithelial wound healing, ocular surface and systemic immune response, and microbiome indices in diabetic mice compared to controls after alkaline chemical injury of the eye. Methods: Corneal alkaline injury was induced in the right eye of Ins2Akita (Akita) mice and wild-type mice. The groups were observed at baseline and subsequently days 0, 3, and 7 after injury. Corneal re-epithelialization was observed under slit lamp with fluorescein staining using a cobalt blue light filter. Enucleated cornea specimens were compared at baseline and after injury for changes in cornea thickness under hematoxylin and eosin staining. Tear cytokine and growth factor levels were measured using protein microarray assay and compared between groups and time points. Flow cytometry was conducted on peripheral blood and ocular surface samples to determine CD3+CD4+ cell count. Fecal samples were collected, and gut microbiota composition and diversity pattern were measured using shotgun sequencing. Results: Akita mice had significantly delayed corneal wound healing compared to controls. This was associated with a reduction in tear levels of vascular endothelial growth factor A, angiopoietin 2, and insulin growth factor 1 on days 0, 3, and 7 after injury. Furthermore, there was a distinct lack of upregulation of peripheral blood and ocular surface CD3+CD4+ cell counts in response to injury in Akita mice compared to controls. This was associated with a reduction in intestinal microbiome diversity indices in Akita mice compared to controls after injury. Specifically, there was a lower abundance of Firmicutes bacterium M10-2 in Akita mice compared to controls after injury. Conclusion: In diabetic mice, impaired cornea wound healing was associated with an inability to mount systemic and local immune response to ocular chemical injury. Baseline and post-injury differences in intestinal microbial diversity and abundance patterns between diabetic mice and controls may potentially play a role in this altered response.


Asunto(s)
Lesiones de la Cornea , Diabetes Mellitus Experimental , Microbioma Gastrointestinal , Ratones , Animales , Factor A de Crecimiento Endotelial Vascular/farmacología , Diabetes Mellitus Experimental/complicaciones , Córnea , Lesiones de la Cornea/complicaciones , Cicatrización de Heridas
9.
Am J Ophthalmol ; 251: 126-142, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36549584

RESUMEN

PURPOSE: To optimize artificial intelligence (AI) algorithms to integrate Scheimpflug-based corneal tomography and biomechanics to enhance ectasia detection. DESIGN: Multicenter cross-sectional case-control retrospective study. METHODS: A total of 3886 unoperated eyes from 3412 patients had Pentacam and Corvis ST (Oculus Optikgeräte GmbH) examinations. The database included 1 eye randomly selected from 1680 normal patients (N) and from 1181 "bilateral" keratoconus (KC) patients, along with 551 normal topography eyes from patients with very asymmetric ectasia (VAE-NT), and their 474 unoperated ectatic (VAE-E) eyes. The current TBIv1 (tomographic-biomechanical index) was tested, and an optimized AI algorithm was developed for augmenting accuracy. RESULTS: The area under the receiver operating characteristic curve (AUC) of the TBIv1 for discriminating clinical ectasia (KC and VAE-E) was 0.999 (98.5% sensitivity; 98.6% specificity [cutoff: 0.5]), and for VAE-NT, 0.899 (76% sensitivity; 89.1% specificity [cutoff: 0.29]). A novel random forest algorithm (TBIv2), developed with 18 features in 156 trees using 10-fold cross-validation, had a significantly higher AUC (0.945; DeLong, P < .0001) for detecting VAE-NT (84.4% sensitivity and 90.1% specificity; cutoff: 0.43; DeLong, P < .0001) and a similar AUC for clinical ectasia (0.999; DeLong, P = .818; 98.7% sensitivity; 99.2% specificity [cutoff: 0.8]). Considering all cases, the TBIv2 had a higher AUC (0.985) than TBIv1 (0.974; DeLong, P < .0001). CONCLUSIONS: AI optimization to integrate Scheimpflug-based corneal tomography and biomechanical assessments augments accuracy for ectasia detection, characterizing ectasia susceptibility in the diverse VAE-NT group. Some patients with VAE may have true unilateral ectasia. Machine learning considering additional data, including epithelial thickness or other parameters from multimodal refractive imaging, will continuously enhance accuracy. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.


Asunto(s)
Queratocono , Humanos , Estudios Retrospectivos , Topografía de la Córnea/métodos , Queratocono/diagnóstico , Inteligencia Artificial , Dilatación Patológica/diagnóstico , Paquimetría Corneal/métodos , Estudios Transversales , Córnea/diagnóstico por imagen , Curva ROC , Tomografía/métodos
11.
Ophthalmic Physiol Opt ; 42(6): 1326-1337, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36102169

RESUMEN

INTRODUCTION: To compare intrasession agreement and repeatability of wavefront aberration measurements from three different aberrometers obtained using Hartmann-Shack, ray tracing and automated retinoscopy methods, as well as their interdevice agreement. METHODS: Three consecutive measurements were obtained using the Pentacam AXL Wave, the iTrace and the OPD-Scan III in 47 eyes of 47 patients. Wavefront refractions, root mean square of total aberrations (RMS total), RMS of higher-order aberrations (HOA) and second-, third- and fourth-order HOAs were exported for 4-mm pupils. Wavefront refractions were converted into vector components: M, J0 and J45 . Intrasession agreement and repeatability were evaluated using intraclass correlation coefficients (ICCs) and repeatability coefficients (RCs); interdevice agreement was assessed using the Bland-Altman method. RESULTS: The intrasession agreement and repeatability of RMS HOA were comparable between the three devices; both the Pentacam AXL Wave and the OPD-Scan III had better intrasession agreement and repeatability for the RMS total than the iTrace (p ≤ 0.02). Intrasession repeatability for the majority of second- and third-order aberrations was better on the Pentacam AXL Wave than on the iTrace (p ≤ 0.01) and OPD-Scan III (p ≤ 0.04), although their agreement and repeatability in spherical aberration were comparable (p ≥ 0.24). Significant systematic differences and proportional bias were detected for almost all refraction power vectors and Zernike coefficients among the three devices. CONCLUSIONS: In this study, all three devices provided good-to-excellent agreement for aberration measurements. Most of the individual Zernike's components were not exchangeable between different aberrometers. Their relative intrasession performance in agreement and repeatability varied significantly across different ocular aberration parameters.


Asunto(s)
Aberración de Frente de Onda Corneal , Humanos , Aberrometría/métodos , Refracción Ocular , Reproducibilidad de los Resultados , Retinoscopía
12.
Indian J Ophthalmol ; 70(8): 2930-2935, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35918946

RESUMEN

Purpose: To analyze the 5-year results of accelerated corneal collagen crosslinking (CXL) for progressive keratoconus and identify preoperative characteristics predictive of visual and topographic outcomes. Methods: A prospective interventional case series. Nineteen eyes of 19 patients receiving accelerated CXL with settings of 18 mW/cm2 for 5 min were included. Clinical and topographic parameters were assessed. Linear regression and logistic regression were used to compare the R2 and odds ratio (OR), respectively, between baseline characteristics and postoperative outcomes. Results: Corrected distance visual acuity (CDVA) remained stable from 0.28 ± 0.21 to 0.25 ± 0.18 logMAR (P = 0.486). The mean cylindrical refraction was stable (P = 0.119). The maximal keratometry (Kmax) decreased from 61.99 ± 10.37 to 59.25 ± 7.75 D (P < 0.001), flattening in the flattest and steepest meridians and mean keratometry were also observed (P ≤ 0.040). The mean anterior elevation at the apex reduced from 21.42 ± 16.69 to 18.53 ± 12.74 µm (P = 0.013) and changes in posterior elevation were non-significant (P = 0.629). Preoperative Kmax best predicted the postoperative change in Kmax (R2 = 0.55, P < 0.001) compared to the other baseline characteristics (P ≤ 0.028), whereas preoperative CDVA was the only significant predictor of postoperative change in CDVA (R2 = 0.41, P = 0.003). Accelerated CXL is less likely to fail in eyes with a steeper preoperative Kmax (OR = 0.74, P = 0.040) or greater posterior elevation at the apex (OR = 0.91, P = 0.042). Conclusion: Kmax significantly decreased following accelerated CXL. Eyes with worse preoperative CDVA and higher Kmax were more likely to have an improvement in visual acuity and corneal flattening.


Asunto(s)
Queratocono , Fotoquimioterapia , Colágeno/uso terapéutico , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Humanos , Queratocono/diagnóstico , Queratocono/tratamiento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Riboflavina/uso terapéutico , Rayos Ultravioleta
14.
Environ Sci Technol Lett ; 9(5): 375-382, 2022 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-35573269

RESUMEN

Relatively high concentrations of preexisting particles, acting as a condensation sink (CS) of gaseous precursors, have been thought to suppress the occurrence of new particle formation (NPF) in urban environments, yet NPF still occurs frequently. Here, we aim to understand the factors promoting and inhibiting NPF events in urban Beijing by combining one-year-long measurements of particle number size distributions and PM2.5 chemical composition. Our results show that indeed the CS is an important factor controlling the occurrence of NPF events, with its chemical composition affecting the efficiency of the background particles in removing gaseous H2SO4 (effectiveness of the CS) driving NPF. During our observation period, the CS was found to be more effective for ammonium nitrate-rich (NH4NO3-rich) fine particles. On non-NPF event days, particles acting as CS contained a larger fraction of NH4NO3 compared to NPF event days under comparable CS levels. In particular, in the CS range from 0.02 to 0.03 s-1, the nitrate fraction was 17% on NPF event days and 26% on non-NPF event days. Overall, our results highlight the importance of considering the chemical composition of preexisting particles when estimating the CS and their role in inhibiting NPF events, especially in urban environments.

15.
Semin Ophthalmol ; 37(5): 676-681, 2022 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-35476818

RESUMEN

AIM: To compare the safety, efficacy, and predictability outcomes of combined sub-Bowman's keratomileusis (thin flap laser in situ keratomileusis [LASIK]) and accelerated crosslinking (CXL) using two different irradiation durations. METHODS: A retrospective comparative study of patients with percent tissue altered ≥35%, undergoing simultaneous CXL during sub-Bowman's keratomileusis were recruited. Following riboflavin application, they underwent ultraviolet-A (UVA) irradiation (18 mW/cm2) for either 2 min (total energy 2.16 J/cm2) or 3 min (total energy 3.24 J/cm2). Visual and refractive outcomes were compared between follow-up visits during the first year postoperatively. Demarcation line and endothelial cell count were evaluated, respectively, at 1 and 3 months postoperatively. RESULTS: The baseline characteristics were similar between the 40 eyes/patients treated using the 2-min protocol and the 33 eyes/patients treated with the 3-min protocol (p ≥ .114). Uncorrected distance visual acuity and corrected distance visual acuity were significantly better for eyes treated with the shorter irradiation protocol on Day 1 (p ≤ .030) and Month 1 (p ≤ .040) postoperatively; these differences diminished by Month 3 (p ≥ .070). Likewise, the efficacy index was higher during the first postoperative week for the 2-min protocol (p ≤ .043). At 1 year, the proportion of eye attaining within 0.5 D of target refraction was 80.0% and 84.8% for the 2-min and 3-min protocols, respectively (p = .590). The corresponding corneal stromal demarcation line depth and endothelial cell density changes were comparable between the two groups (p = .311 and 0.899, respectively). CONCLUSIONS: A comparable volume of crosslinked corneal tissue can be achieved by using a shorter UVA irradiation duration. Additional duration of UVA irradiation could lead to delay in visual rehabilitation after simultaneous sub-Bowman's keratomileusis and CXL.


Asunto(s)
Colágeno , Queratomileusis por Láser In Situ , Miopía , Colágeno/metabolismo , Humanos , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Fármacos Fotosensibilizantes/uso terapéutico , Refracción Ocular , Estudios Retrospectivos , Rayos Ultravioleta
16.
Nat Commun ; 13(1): 28, 2022 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-35013178

RESUMEN

Heatwaves exert disproportionately strong and sometimes irreversible impacts on forest ecosystems. These impacts remain poorly understood at the tree and species level and across large spatial scales. Here, we investigate the effects of the record-breaking 2018 European heatwave on tree growth and tree water status using a collection of high-temporal resolution dendrometer data from 21 species across 53 sites. Relative to the two preceding years, annual stem growth was not consistently reduced by the 2018 heatwave but stems experienced twice the temporary shrinkage due to depletion of water reserves. Conifer species were less capable of rehydrating overnight than broadleaves across gradients of soil and atmospheric drought, suggesting less resilience toward transient stress. In particular, Norway spruce and Scots pine experienced extensive stem dehydration. Our high-resolution dendrometer network was suitable to disentangle the effects of a severe heatwave on tree growth and desiccation at large-spatial scales in situ, and provided insights on which species may be more vulnerable to climate extremes.


Asunto(s)
Cambio Climático , Deshidratación , Ecología , Bosques , Rayos Infrarrojos , Clima , Sequías , Ecosistema , Noruega , Picea , Pinus sylvestris , Suelo , Árboles , Agua
17.
Ophthalmol Ther ; 11(1): 35-67, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34762259

RESUMEN

We systematically reviewed published research on dry eye disease and its association with higher order aberrations (HOAs). The purpose of this review was to first determine if an association between tear film metrics and HOAs exists and second to determine if the treatment of dry eyes can improve tear film metrics and HOAs together. A search was conducted in Entrez PubMed on 25 April 2021 using the keywords "higher order aberrations" and "dry eye". The initial search yielded 61 articles. After publications were restricted to only original articles measuring HOA outcomes in patients with dry eye, the final yield was 27 relevant articles. Of these 27 papers, 12 directly looked at associations and correlations between dry eyes and HOA parameters. The remaining 15 studies looked at dry eye interventions and HOA outcomes and parameters. There is clear evidence demonstrating that dry eyes and HOAs have an association, and that the tear film is one of the most important factors in this relationship. There is also a direct correlation between tear film metrics and HOAs. Improvements in HOAs with dry eye interventions provide further evidence to support the intricate relationship between the two. Despite the clear association between HOAs and dry eye disease, further research is still required in the realm of clinical application as dry eye interventions vary depending on many factors, including patient severity and eye drop viscosity.

19.
Sci Rep ; 11(1): 14853, 2021 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-34290281

RESUMEN

To evaluate the repeatability and agreement of corneal and biometry measurements obtained with two swept-source optical coherence tomography (SSOCT) and a partial coherence interferometry-based device. This is a cross-sectional study. Forty-eight eyes of 48 patients had three consecutive measurements for ANTERION (Heidelberg Engineering, Germany), CASIAII (Tomey, Japan) and IOLMaster500 (Carl Zeiss Meditec, USA) on the same visit. Mean keratometry (Km), central corneal thickness (CCT), anterior chamber depth (ACD) and axial length (AL) were recorded. Corneal astigmatic measurements were converted into vector components-J0 and J45. Intra-device repeatability and agreements of measurements amongst the devices were evaluated using repeatability coefficients (RCs) and Bland-Altman plots, respectively. All devices demonstrated comparable repeatability for Km (p ≥ 0.138). ANTERION had the lowest RC for J0 amongst the devices (p ≤ 0.039). Systematic difference was found for the Km and J0 obtained with IOLMaster500 compared to either SSOCTs (p ≤ 0.010). The ACD and AL measured by IOLMaster500 showed a higher RC compared with either SSOCTs (p < 0.002). Systematic difference was found in CCT and ACD between the two SSOCTs (p < 0.001), and in AL between ANTERION and IOLMaster500 (p < 0.001), with a mean difference of 1.6 µm, 0.022 mm and 0.021 mm, respectively. Both SSOCTs demonstrated smaller test-retest variability for measuring ACD and AL compared with IOLMaster500. There were significant disagreement in keratometry and AL measurements between the SSOCTs and PCI-based device; their measurements should not be considered as interchangeable.


Asunto(s)
Cámara Anterior/diagnóstico por imagen , Longitud Axial del Ojo/diagnóstico por imagen , Córnea/diagnóstico por imagen , Interferometría/instrumentación , Tomografía de Coherencia Óptica/instrumentación , Adulto , Anciano , Cámara Anterior/patología , Longitud Axial del Ojo/patología , Córnea/patología , Estudios Transversales , Alemania , Humanos , Japón , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...