Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38083653

RESUMEN

Wireless communication enables an ingestible device to send sensor information and support external on-demand operation while in the gastrointestinal (GI) tract. However, it is challenging to maintain stable wireless communication with an ingestible device that travels inside the dynamic GI environment as this environment easily detunes the antenna and decreases the antenna gain. In this paper, we propose an air-gap based antenna solution to stabilize the antenna gain inside this dynamic environment. By surrounding a chip antenna with 1 ~ 2 mms of air, the antenna is isolated from the environment, recovering its antenna gain and the received signal strength by 12 dB or more according to our in vitro and in vivo evaluation in swine. The air gap makes margin for the high path loss, enabling stable wireless communication at 2.4 GHz that allows users to easily access their ingestible devices by using mobile devices with Bluetooth Low Energy (BLE). On the other hand, the data sent or received over the wireless medium is vulnerable to being eavesdropped on by nearby devices other than authorized users. Therefore, we also propose a lightweight security protocol. The proposed protocol is implemented in low energy without compromising the security level thanks to the base protocol of symmetric challenge-response and Speck, the cipher that is optimized for software implementation.


Asunto(s)
Redes de Comunicación de Computadores , Tracto Gastrointestinal , Tecnología Inalámbrica , Animales , Programas Informáticos , Porcinos
2.
Sci Adv ; 9(30): eadh5325, 2023 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-37506210

RESUMEN

Ultrasound is widely used for tissue imaging such as breast cancer diagnosis; however, fundamental challenges limit its integration with wearable technologies, namely, imaging over large-area curvilinear organs. We introduced a wearable, conformable ultrasound breast patch (cUSBr-Patch) that enables standardized and reproducible image acquisition over the entire breast with less reliance on operator training and applied transducer compression. A nature-inspired honeycomb-shaped patch combined with a phased array is guided by an easy-to-operate tracker that provides for large-area, deep scanning, and multiangle breast imaging capability. The in vitro studies and clinical trials reveal that the array using a piezoelectric crystal [Yb/Bi-Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3] (Yb/Bi-PIN-PMN-PT) exhibits a sufficient contrast resolution (~3 dB) and axial/lateral resolutions of 0.25/1.0 mm at 30 mm depth, allowing the observation of small cysts (~0.3 cm) in the breast. This research develops a first-of-its-kind ultrasound technology for breast tissue scanning and imaging that offers a noninvasive method for tracking real-time dynamic changes of soft tissue.


Asunto(s)
Plomo , Transductores , Ultrasonografía
3.
Nat Nanotechnol ; 18(5): 456-463, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37106051

RESUMEN

Two-dimensional (2D) materials are promising candidates for future electronics due to their excellent electrical and photonic properties. Although promising results on the wafer-scale synthesis (≤150 mm diameter) of monolayer molybdenum disulfide (MoS2) have already been reported, the high-quality synthesis of 2D materials on wafers of 200 mm or larger, which are typically used in commercial silicon foundries, remains difficult. The back-end-of-line (BEOL) integration of directly grown 2D materials on silicon complementary metal-oxide-semiconductor (CMOS) circuits is also unavailable due to the high thermal budget required, which far exceeds the limits of silicon BEOL integration (<400 °C). This high temperature forces the use of challenging transfer processes, which tend to introduce defects and contamination to both the 2D materials and the BEOL circuits. Here we report a low-thermal-budget synthesis method (growth temperature < 300 °C, growth time ≤ 60 min) for monolayer MoS2 films, which enables the 2D material to be synthesized at a temperature below the precursor decomposition temperature and grown directly on silicon CMOS circuits without requiring any transfer process. We designed a metal-organic chemical vapour deposition reactor to separate the low-temperature growth region from the high-temperature chalcogenide-precursor-decomposition region. We obtain monolayer MoS2 with electrical uniformity on 200 mm wafers, as well as a high material quality with an electron mobility of ~35.9 cm2 V-1 s-1. Finally, we demonstrate a silicon-CMOS-compatible BEOL fabrication process flow for MoS2 transistors; the performance of these silicon devices shows negligible degradation (current variation < 0.5%, threshold voltage shift < 20 mV). We believe that this is an important step towards monolithic 3D integration for future electronics.

4.
Sci Adv ; 9(12): eadf1978, 2023 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-36947609

RESUMEN

Smallholder farmers and manufacturers in the Agri-Food sector face substantial challenges because of increasing circulation of counterfeit products (e.g., seeds), for which current countermeasures are implemented mainly at the secondary packaging level, and are generally vulnerable because of limited security guarantees. Here, by integrating biopolymer design with physical unclonable functions (PUFs), we propose a cryptographic protocol for seed authentication using biodegradable and miniaturized PUF tags made of silk microparticles. By simply drop casting a mixture of variant silk microparticles on a seed surface, tamper-evident PUF tags can be seamlessly fabricated on a variety of seeds, where the unclonability comes from the stochastic assembly of spectrally and visually distinct silk microparticles in the tag. Unique, reproducible, and unpredictable PUF codes are generated from both Raman mapping and microscopy imaging of the silk tags. Together, the proposed technology offers a highly secure solution for anticounterfeiting and product traceability in agriculture.

5.
Science ; 365(6449): 145-150, 2019 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-31296764

RESUMEN

Artificial muscles may accelerate the development of robotics, haptics, and prosthetics. Although advances in polymer-based actuators have delivered unprecedented strengths, producing these devices at scale with tunable dimensions remains a challenge. We applied a high-throughput iterative fiber-drawing technique to create strain-programmable artificial muscles with dimensions spanning three orders of magnitude. These fiber-based actuators are thermally and optically controllable, can lift more than 650 times their own weight, and withstand strains of >1000%. Integration of conductive nanowire meshes within these fiber-based muscles offers piezoresistive strain feedback and demonstrates long-term resilience across >105 deformation cycles. The scalable dimensions of these fiber-based actuators and their strength and responsiveness may extend their impact from engineering fields to biomedical applications.


Asunto(s)
Órganos Artificiales , Ingeniería Biomédica , Fibra de Carbono/química , Fibras Musculares Esqueléticas/química , Polimetil Metacrilato/química , Prótesis e Implantes , Robótica
6.
Science ; 360(6391): 915-918, 2018 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-29798884

RESUMEN

Biomolecular monitoring in the gastrointestinal tract could offer rapid, precise disease detection and management but is impeded by access to the remote and complex environment. Here, we present an ingestible micro-bio-electronic device (IMBED) for in situ biomolecular detection based on environmentally resilient biosensor bacteria and miniaturized luminescence readout electronics that wirelessly communicate with an external device. As a proof of concept, we engineer heme-sensitive probiotic biosensors and demonstrate accurate diagnosis of gastrointestinal bleeding in swine. Additionally, we integrate alternative biosensors to demonstrate modularity and extensibility of the detection platform. IMBEDs enable new opportunities for gastrointestinal biomarker discovery and could transform the management and diagnosis of gastrointestinal disease.


Asunto(s)
Técnicas Biosensibles/instrumentación , Enfermedades Gastrointestinales/diagnóstico , Tracto Gastrointestinal/microbiología , Tracto Gastrointestinal/fisiopatología , Monitoreo Fisiológico/instrumentación , Probióticos , Animales , Equipos y Suministros Eléctricos , Enfermedades Gastrointestinales/microbiología , Hemorragia Gastrointestinal/diagnóstico , Hemo/química , Porcinos
7.
Artículo en Inglés | MEDLINE | ID: mdl-28458955

RESUMEN

Ingestible electronics have revolutionized the standard of care for a variety of health conditions. Extending the capacity and safety of these devices, and reducing the costs of powering them, could enable broad deployment of prolonged monitoring systems for patients. Although prior biocompatible power harvesting systems for in vivo use have demonstrated short minute-long bursts of power from the stomach, not much is known about the capacity to power electronics in the longer term and throughout the gastrointestinal tract. Here, we report the design and operation of an energy-harvesting galvanic cell for continuous in vivo temperature sensing and wireless communication. The device delivered an average power of 0.23 µW per mm2 of electrode area for an average of 6.1 days of temperature measurements in the gastrointestinal tract of pigs. This power-harvesting cell has the capacity to provide power for prolonged periods of time to the next generation of ingestible electronic devices located in the gastrointestinal tract.

8.
Nano Lett ; 15(11): 7211-6, 2015 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-26468687

RESUMEN

In this work, we leverage graphene's unique tunable Seebeck coefficient for the demonstration of a graphene-based thermal imaging system. By integrating graphene based photothermo-electric detectors with micromachined silicon nitride membranes, we are able to achieve room temperature responsivities on the order of ~7-9 V/W (at λ = 10.6 µm), with a time constant of ~23 ms. The large responsivities, due to the combination of thermal isolation and broadband infrared absorption from the underlying SiN membrane, have enabled detection as well as stand-off imaging of an incoherent blackbody target (300-500 K). By comparing the fundamental achievable performance of these graphene-based thermopiles with standard thermocouple materials, we extrapolate that graphene's high carrier mobility can enable improved performances with respect to two main figures of merit for infrared detectors: detectivity (>8 × 10(8) cm Hz(1/2) W(-1)) and noise equivalent temperature difference (<100 mK). Furthermore, even average graphene carrier mobility (<1000 cm(2) V(-1) s(-1)) is still sufficient to detect the emitted thermal radiation from a human target.

9.
IEEE J Solid-State Circuits ; 50(1): 214-229, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-26251552

RESUMEN

A system-on-chip for an invisible, fully-implantable cochlear implant is presented. Implantable acoustic sensing is achieved by interfacing the SoC to a piezoelectric sensor that detects the sound-induced motion of the middle ear. Measurements from human cadaveric ears demonstrate that the sensor can detect sounds between 40 and 90 dB SPL over the speech bandwidth. A highly-reconfigurable digital sound processor enables system power scalability by reconfiguring the number of channels, and provides programmable features to enable a patient-specific fit. A mixed-signal arbitrary waveform neural stimulator enables energy-optimal stimulation pulses to be delivered to the auditory nerve. The energy-optimal waveform is validated with in-vivo measurements from four human subjects which show a 15% to 35% energy saving over the conventional rectangular waveform. Prototyped in a 0.18 µm high-voltage CMOS technology, the SoC in 8-channel mode consumes 572 µW of power including stimulation. The SoC integrates implantable acoustic sensing, sound processing, and neural stimulation on one chip to minimize the implant size, and proof-of-concept is demonstrated with measurements from a human cadaver ear.

10.
IEEE J Solid-State Circuits ; 49(7): 1463-1474, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26246641

RESUMEN

This paper presents the design of a narrowband transmitter and antenna system that achieves an average power consumption of 78 pW when operating at a duty-cycled data rate of 1 bps. Fabricated in a 0.18 µm CMOS process, the transmitter employs a direct-RF power oscillator topology where a loop antenna acts as a both a radiative and resonant element. The low-complexity single-stage architecture, in combination with aggressive power gating techniques and sizing optimizations, limited the standby power of the transmitter to only 39.7 pW at 0.8 V. Supporting both OOK and FSK modulations at 2.4 GHz, the transmitter consumed as low as 38 pJ/bit at an active-mode data rate of 5 Mbps. The loop antenna and integrated diodes were also used as part of a wireless power transfer receiver in order to kick-start the system power supply during energy harvesting operation.

11.
IEEE J Solid-State Circuits ; 49(12): 2812-2824, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25983340

RESUMEN

This paper presents a nW power management unit (PMU) for an autonomous wireless sensor that sustains itself by harvesting energy from the endocochlear potential (EP), the 70-100 mV electrochemical bio-potential inside the mammalian ear. Due to the anatomical constraints inside the inner ear, the total extractable power from the EP is limited to 1.1-6.25 nW. A nW boost converter is used to increase the input voltage (30-55 mV) to a higher voltage (0.8 to 1.1 V) usable by CMOS circuits in the sensor. A pW Charge Pump circuit is used to minimize the leakage in the boost converter. Further, ultra-low-power control circuits consisting of digital implementations of input impedance adjustment circuits and Zero Current Switching circuits along with Timer and Reference circuits keep the quiescent power of the PMU down to 544 pW. The designed boost converter achieves a peak power conversion efficiency of 56%. The PMU can sustain itself and a duty-cyled ultra-low power load while extracting power from the EP of a live guinea pig. The PMU circuits have been implemented on a 0.18µm CMOS process.

12.
Lab Chip ; 13(19): 3903-3909, 2013 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-23925122

RESUMEN

The electrical properties of biological cells have connections to their pathological states. Here we present an electric impedance microflow cytometry (EIMC) platform for the characterization of disease states of single cells. This platform entails a microfluidic device for a label-free and non-invasive cell-counting assay through electric impedance sensing. We identified a dimensionless offset parameter δ obtained as a linear combination of a normalized phase shift and a normalized magnitude shift in electric impedance to differentiate cells on the basis of their pathological states. This paper discusses a representative case study on red blood cells (RBCs) invaded by the malaria parasite Plasmodium falciparum. Invasion by P. falciparum induces physical and biochemical changes on the host cells throughout a 48-h multi-stage life cycle within the RBC. As a consequence, it also induces progressive changes in electrical properties of the host cells. We demonstrate that the EIMC system in combination with data analysis involving the new offset parameter allows differentiation of P. falciparum infected RBCs from uninfected RBCs as well as among different P. falciparum intraerythrocytic asexual stages including the ring stage. The representative results provided here also point to the potential of the proposed experimental and analysis platform as a valuable tool for non-invasive diagnostics of a wide variety of disease states and for cell separation.


Asunto(s)
Eritrocitos/citología , Eritrocitos/parasitología , Citometría de Flujo/métodos , Técnicas Analíticas Microfluídicas/métodos , Impedancia Eléctrica , Humanos , Plasmodium falciparum/fisiología
13.
Nat Biotechnol ; 30(12): 1240-3, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23138225

RESUMEN

Endocochlear potential (EP) is a battery-like electrochemical gradient found in and actively maintained by the inner ear. Here we demonstrate that the mammalian EP can be used as a power source for electronic devices. We achieved this by designing an anatomically sized, ultra-low quiescent-power energy harvester chip integrated with a wireless sensor capable of monitoring the EP itself. Although other forms of in vivo energy harvesting have been described in lower organisms, and thermoelectric, piezoelectric and biofuel devices are promising for mammalian applications, there have been few, if any, in vivo demonstrations in the vicinity of the ear, eye and brain. In this work, the chip extracted a minimum of 1.12 nW from the EP of a guinea pig for up to 5 h, enabling a 2.4 GHz radio to transmit measurement of the EP every 40-360 s. With future optimization of electrode design, we envision using the biologic battery in the inner ear to power chemical and molecular sensors, or drug-delivery actuators for diagnosis and therapy of hearing loss and other disorders.


Asunto(s)
Fuentes de Energía Bioeléctrica , Oído Interno/fisiología , Animales , Biotecnología , Potenciales Microfónicos de la Cóclea/fisiología , Oído Interno/anatomía & histología , Electrónica Médica/instrumentación , Fenómenos Electrofisiológicos , Diseño de Equipo , Cobayas
14.
Annu Rev Biomed Eng ; 10: 247-74, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18647116

RESUMEN

The electronics of a general biomedical device consist of energy delivery, analog-to-digital conversion, signal processing, and communication subsystems. Each of these blocks must be designed for minimum energy consumption. Specific design techniques, such as aggressive voltage scaling, dynamic power-performance management, and energy-efficient signaling, must be employed to adhere to the stringent energy constraint. The constraint itself is set by the energy source, so energy harvesting holds tremendous promise toward enabling sophisticated systems without straining user lifestyle. Further, once harvested, efficient delivery of the low-energy levels, as well as robust operation in the aggressive low-power modes, requires careful understanding and treatment of the specific design limitations that dominate this realm. We outline the performance and power constraints of biomedical devices, and present circuit techniques to achieve complete systems operating down to power levels of microwatts. In all cases, approaches that leverage advanced technology trends are emphasized.


Asunto(s)
Ingeniería Biomédica/instrumentación , Suministros de Energía Eléctrica/tendencias , Electrónica Médica/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Telemetría/instrumentación , Ingeniería Biomédica/tendencias , Electrónica Médica/tendencias , Transferencia de Energía , Diseño de Equipo , Evaluación de la Tecnología Biomédica , Telemetría/tendencias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...