Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Eur Radiol Exp ; 8(1): 19, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38347188

RESUMEN

BACKGROUND: A dual-function phantom designed to quantify the apparent diffusion coefficient (ADC) in different fat contents (FCs) and glass bead densities (GBDs) to simulate the human tissues has not been documented yet. We propose a dual-function phantom to quantify the FC and to measure the ADC at different FCs and different GBDs. METHODS: A fat-containing diffusion phantom comprised by 30 glass-bead-containing fat-water emulsions consisting of six different FCs (0, 10, 20, 30, 40, and 50%) multiplied by five different GBDs (0, 0.1, 0.25, 0.5, and 1.0 g/50 mL). The FC and ADC were measured by the "iterative decomposition of water and fat with echo asymmetry and least squares estimation-IQ," IDEAL-IQ, and single-shot echo-planar diffusion-weighted imaging, SS-EP-DWI, sequences, respectively. Linear regression analysis was used to evaluate the relationship among the fat fraction (FF) measured by IDEAL-IQ, GBD, and ADC. RESULTS: The ADC was significantly, negatively, and linearly associated with the FF (the linear slope ranged from -0.005 to -0.017, R2 = 0.925 to 0.986, all p < 0.001). The slope of the linear relationship between the ADC and the FF, however, varied among different GBDs (the higher the GBD, the lower the slope). ADCs among emulsions across different GBDs and FFs were overlapped. Emulsions with low GBDs plus high FFs shared a same lower ADC range with those with median or high GBDs plus median or lower FFs. CONCLUSIONS: A novel dual-function phantom simulating the human tissues allowed to quantify the influence of FC and GBD on ADC. RELEVANCE STATEMENT: The study developed an innovative dual-function MRI phantom to explore the impact of FC on ADC variation that can affect clinical results. The results revealed the superimposed effect on FF and GBD density on ADC measurements. KEY POINTS: • A dual-function phantom made of glass bead density (GBD) and fat fraction (FF) emulsion has been developed. • Apparent diffusion coefficient (ADC) values are determined by GBD and FF. • The dual-function phantom showed the mutual ADC addition between FF and GBD.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen por Resonancia Magnética , Humanos , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar , Agua , Fantasmas de Imagen
2.
Adv Sci (Weinh) ; 11(7): e2305495, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38072667

RESUMEN

Magnetic resonance imaging (MRI) demonstrates clear advantages over other imaging modalities in neurosurgery with its ability to delineate critical neurovascular structures and cancerous tissue in high-resolution 3D anatomical roadmaps. However, its application has been limited to interventions performed based on static pre/post-operative imaging, where errors accrue from stereotactic frame setup, image registration, and brain shift. To leverage the powerful intra-operative functions of MRI, e.g., instrument tracking, monitoring of physiological changes and tissue temperature in MRI-guided bilateral stereotactic neurosurgery, a multi-stage robotic positioner is proposed. The system positions cannula/needle instruments using a lightweight (203 g) and compact (Ø97 × 81 mm) skull-mounted structure that fits within most standard imaging head coils. With optimized design in soft robotics, the system operates in two stages: i) manual coarse adjustment performed interactively by the surgeon (workspace of ±30°), ii) automatic fine adjustment with precise (<0.2° orientation error), responsive (1.4 Hz bandwidth), and high-resolution (0.058°) soft robotic positioning. Orientation locking provides sufficient transmission stiffness (4.07 N/mm) for instrument advancement. The system's clinical workflow and accuracy is validated with lab-based (<0.8 mm) and MRI-based testing on skull phantoms (<1.7 mm) and a cadaver subject (<2.2 mm). Custom-made wireless omni-directional tracking markers facilitated robot registration under MRI.


Asunto(s)
Neurocirugia , Robótica , Procedimientos Neuroquirúrgicos/métodos , Encéfalo , Imagen por Resonancia Magnética/métodos
3.
IEEE Trans Med Imaging ; 43(1): 439-448, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37647176

RESUMEN

We present a design of an inductively coupled radio frequency (ICRF) marker for magnetic resonance (MR)-based positional tracking, enabling the robust increase of tracking signal at all scanning orientations in quadrature-excited closed MR imaging (MRI). The marker employs three curved resonant circuits fully covering a cylindrical surface that encloses the signal source. Each resonant circuit is a planar spiral inductor with parallel plate capacitors fabricated monolithically on flexible printed circuit board (FPC) and bent to achieve the curved structure. Size of the constructed marker is Ø3-mm ×5 -mm with quality factor > 22, and its tracking performance was validated with 1.5 T MRI scanner. As result, the marker remains as a high positive contrast spot under 360° rotations in 3 axes. The marker can be accurately localized with a maximum error of 0.56 mm under a displacement of 56 mm from the isocenter, along with an inherent standard deviation of 0.1-mm. Accrediting to the high image contrast, the presented marker enables automatic and real-time tracking in 3D without dependency on its orientation with respect to the MRI scanner receive coil. In combination with its small form-factor, the presented marker would facilitate robust and wireless MR-based tracking for intervention and clinical diagnosis. This method targets applications that can involve rotational changes in all axes (X-Y-Z).


Asunto(s)
Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Fantasmas de Imagen
4.
NMR Biomed ; 37(3): e5063, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37871617

RESUMEN

Recently, intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) has also been demonstrated as an imaging tool for applications in neurological and neurovascular diseases. However, the use of single-shot diffusion-weighted echo-planar imaging for IVIM DWI acquisition leads to suboptimal data quality: for instance, geometric distortion and deteriorated image quality at high spatial resolution. Although the recently commercialized multi-shot acquisition methods, such as multiplexed sensitivity encoding (MUSE), can attain high-resolution and high-quality DWI with signal-to-noise ratio (SNR) performance superior to that of the conventional parallel imaging method, the prolonged scan time associated with multi-shot acquisition is impractical for routine IVIM DWI. This study proposes an acquisition and reconstruction framework based on parametric-POCSMUSE to accelerate the four-shot IVIM DWI with 70% reduction of total scan time (13 min 8 s versus 4 min 8 s). First, the four-shot IVIM DWI scan with 17 b values was accelerated by acquiring only one segment per b value except for b values of 0 and 600 s/mm2 . Second, an IVIM-estimation scheme was integrated into the parametric-POCSMUSE to enable joint reconstruction of multi-b images from under-sampled four-shot IVIM DWI data. In vivo experiments on both healthy subjects and patients show that the proposed framework successfully produced multi-b DW images with significantly higher SNRs and lower reconstruction errors than did the conventional acceleration method based on parallel imaging. In addition, the IVIM quantitative maps estimated from the data produced by the proposed framework showed quality comparable to that of fully sampled MUSE-reconstructed images, suggesting that the proposed framework can enable highly accelerated multi-shot IVIM DWI without sacrificing data quality. In summary, the proposed framework can make multi-shot IVIM DWI feasible in a routine MRI examination, with reasonable scan time and improved geometric fidelity.


Asunto(s)
Alprostadil , Encéfalo , Humanos , Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Cabeza , Imagen por Resonancia Magnética , Imagen Eco-Planar/métodos , Movimiento (Física)
5.
Radiother Oncol ; 189: 109948, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37832790

RESUMEN

BACKGROUND AND PURPOSE: Motion estimation from severely downsampled 4D-MRI is essential for real-time imaging and tumor tracking. This simulation study developed a novel deep learning model for simultaneous MR image reconstruction and motion estimation, named the Downsampling-Invariant Deformable Registration (D2R) model. MATERIALS AND METHODS: Forty-three patients undergoing radiotherapy for liver tumors were recruited for model training and internal validation. Five prospective patients from another center were recruited for external validation. Patients received 4D-MRI scans and 3D MRI scans. The 4D-MRI was retrospectively down-sampled to simulate real-time acquisition. Motion estimation was performed using the proposed D2R model. The accuracy and robustness of the proposed D2R model and baseline methods, including Demons, Elastix, the parametric total variation (pTV) algorithm, and VoxelMorph, were compared. High-quality (HQ) 4D-MR images were also constructed using the D2R model for real-time imaging feasibility verification. The image quality and motion accuracy of the constructed HQ 4D-MRI were evaluated. RESULTS: The D2R model showed significantly superior and robust registration performance than all the baseline methods at downsampling factors up to 500. HQ T1-weighted and T2-weighted 4D-MR images were also successfully constructed with significantly improved image quality, sub-voxel level motion error, and real-time efficiency. External validation demonstrated the robustness and generalizability of the technique. CONCLUSION: In this study, we developed a novel D2R model for deformation estimation of downsampled 4D-MR images. HQ 4D-MR images were successfully constructed using the D2R model. This model may expand the clinical implementation of 4D-MRI for real-time motion management during liver cancer treatment.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Neoplasias Hepáticas , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia
6.
Magn Reson Med ; 90(6): 2454-2471, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37486854

RESUMEN

PURPOSE: To develop a distortion-free motion-resolved four-dimensional diffusion-weighted PROPELLER EPI (4D-DW-PROPELLER-EPI) technique for benefiting clinical abdominal radiotherapy (RT). METHODS: An improved abdominal 4D-DWI technique based on 2D diffusion-weighted PROPELLER-EPI (2D-DW-PROPELLER-EPI), termed 4D-DW-PROPELLER-EPI, was proposed to improve the frame rate of repeated data acquisition and produce distortion-free 4D-DWI images. Since the radial or PROPELLER sampling with golden-angle rotation can achieve an efficient k-space coverage with a flexible time-resolved acquisition, the golden-angle multi-blade acquisition was used in the proposed 4D-DW-PROPELLER-EPI to improve the performance of data sorting. A new k-space and blade (K-B) amplitude binning method was developed for the proposed 4D-DW-PROPELLER-EPI to optimize the number of blades and the k-space uniformity before performing conventional PROPELLER-EPI reconstruction, by using two metrics to evaluate the adequacy of the acquired data. The proposed 4D-DW-PROPELLER-EPI was preliminarily evaluated in both simulation experiments and in vivo experiments with varying frame rates and different numbers of repeated acquisition. RESULTS: The feasibility of achieving distortion-free 4D-DWI images by using the proposed 4D-DW-PROPELLER-EPI technique was demonstrated in both digital phantom and healthy subjects. Evaluation of the 4D completeness metrics shows that the K-B amplitude binning method could simultaneously improve the acquisition efficiency and data reconstruction performance for 4D-DW-PROPELLER-EPI. CONCLUSION: 4D-DW-PROPELLER-EPI with K-B amplitude binning is an advanced technique that can provide distortion-free 4D-DWI images for resolving respiratory motion, and may benefit the application of image-guided abdominal RT.


Asunto(s)
Abdomen , Imagen de Difusión por Resonancia Magnética , Humanos , Imagen de Difusión por Resonancia Magnética/métodos , Abdomen/diagnóstico por imagen , Rotación , Simulación por Computador , Fantasmas de Imagen , Imagen Eco-Planar/métodos
7.
Eur Radiol ; 33(9): 6157-6167, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37095361

RESUMEN

BACKGROUND: To evaluate the effect of the weighting of input imaging combo and ADC threshold on the performance of the U-Net and to find an optimized input imaging combo and ADC threshold in segmenting acute ischemic stroke (AIS) lesion. METHODS: This study retrospectively enrolled a total of 212 patients having AIS. Four combos, including ADC-ADC-ADC (AAA), DWI-ADC-ADC (DAA), DWI-DWI-ADC (DDA), and DWI-DWI-DWI (DDD), were used as input images, respectively. Three ADC thresholds including 0.6, 0.8 and 1.8 × 10-3 mm2/s were applied. Dice similarity coefficient (DSC) was used to evaluate the segmentation performance of U-Nets. Nonparametric Kruskal-Wallis test with Tukey-Kramer post-hoc tests were used for comparison. A p < .05 was considered statistically significant. RESULTS: The DSC significantly varied among different combos of images and different ADC thresholds. Hybrid U-Nets outperformed uniform U-Nets at ADC thresholds of 0.6 × 10-3 mm2/s and 0.8 × 10-3 mm2/s (p < .001). The U-Net with imaging combo of DDD had segmentation performance similar to hybrid U-Nets at an ADC threshold of 1.8 × 10-3 mm2/s (p = .062 to 1). The U-Net using the imaging combo of DAA at the ADC threshold of 0.6 × 10-3 mm2/s achieved the highest DSC in the segmentation of AIS lesion. CONCLUSIONS: The segmentation performance of U-Net for AIS varies among the input imaging combos and ADC thresholds. The U-Net is optimized by choosing the imaging combo of DAA at an ADC threshold of 0.6 × 10-3 mm2/s in segmentating AIS lesion with highest DSC. KEY POINTS: • Segmentation performance of U-Net for AIS differs among input imaging combos. • Segmentation performance of U-Net for AIS differs among ADC thresholds. • U-Net is optimized using DAA with ADC = 0.6 × 10-3 mm2/s.


Asunto(s)
Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Estudios Retrospectivos , Accidente Cerebrovascular/diagnóstico por imagen
8.
J Vis Exp ; (186)2022 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-36121278

RESUMEN

Preclinical experimental models of hepatocellular carcinoma (HCC) that recapitulate human disease represent an important tool to study tumorigenesis and evaluate novel therapeutic approaches. Non-invasive whole-body imaging using positron emission tomography (PET) provides critical insights into the in vivo characteristics of tissues at the molecular level in real-time. We present here a protocol for orthotopic HCC xenograft creation with and without hepatic artery ligation (HAL) to induce tumor hypoxia and the assessment of their tumor metabolism in vivo using [18F]Fluoromisonidazole ([18F]FMISO) and [18F]Fluorodeoxyglucose ([18F]FDG) PET/magnetic resonance (MR) imaging. Tumor hypoxia could be readily visualized using the hypoxia marker [18F]FMISO, and it was found that the [18F]FMISO uptake was higher in HCC mice that underwent HAL than in the non-HAL group, whereas [18F]FDG could not distinguish tumor hypoxia between the two groups. HAL tumors also displayed a higher level of hypoxia-inducible factor (HIF)-1α expression in response to hypoxia. Quantification of HAL tumors showed a 2.3-fold increase in [18F]FMISO uptake based on the standardized value uptake (SUV) approach.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Animales , Carcinoma Hepatocelular/diagnóstico por imagen , Modelos Animales de Enfermedad , Fluorodesoxiglucosa F18/metabolismo , Humanos , Hipoxia , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Ratones , Misonidazol/análogos & derivados , Tomografía de Emisión de Positrones/métodos , Radiofármacos
9.
J Gastroenterol Hepatol ; 37(6): 1139-1147, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35368120

RESUMEN

BACKGROUND AND AIM: Liver fibrosis and steatosis are important factors affecting chronic hepatitis B (CHB) disease outcome. Multiparametric magnetic resonance (MR) imaging of the liver measures fibroinflammation, fat, and iron through iron-corrected T1 relaxation time (cT1), proton density fat fraction (PDFF), and T2*-weighted imaging, respectively. We assessed the utility of MR metrics for prognostication in CHB. METHODS: Chronic hepatitis B patients receiving nucleos(t)ide analogs with advanced fibrosis documented by vibration-controlled transient elastography were recruited. Paired multiparametric MR liver and transient elastography were performed at baseline and after at least 2 years. Adverse outcomes including death, hepatocellular carcinoma (HCC), and liver decompensation were monitored. RESULTS: One hundred and ninety-two patients (mean age 60.3 ± 8.5 years; 76.0% male) were recruited. Eight patients (4.2%) developed HCC after 11.6 (8.8-22.8) months, and increased baseline liver iron independently predicted HCC (hazard ratio 2.329 [1.030-5.266]; P = 0.042). Liver MR metrics were not predictive of death or hepatic decompensation. Among 150 patients with follow-up liver MR at 30.3 (25.2-35.6) months, longitudinal liver PDFF increase was associated with liver cT1 increase (odds ratio 1.571 [1.217-2.029]; P = 0.001). Ninety patients received simultaneous multiparametric MR pancreas during the follow-up MR. Pancreatic PDFF correlated with liver PDFF (r = 0.501, P < 0.001), while pancreatic T1 had no correlation with liver cT1 (r = -0.092, P = 0.479). Pancreatic T1 and PDFF were not associated with adverse outcomes. CONCLUSION: Among CHB patients with advanced disease, liver iron level on MR predicts HCC. Multiparametric MR can also simultaneously assess the pancreas and the liver. Multiparametric MR should be further studied as a one-stop option for monitoring and prognosticating CHB.


Asunto(s)
Carcinoma Hepatocelular , Diagnóstico por Imagen de Elasticidad , Hepatitis B Crónica , Neoplasias Hepáticas , Enfermedad del Hígado Graso no Alcohólico , Anciano , Benchmarking , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/etiología , Carcinoma Hepatocelular/patología , Femenino , Hepatitis B Crónica/complicaciones , Hepatitis B Crónica/tratamiento farmacológico , Hepatitis B Crónica/patología , Humanos , Hierro , Hígado/diagnóstico por imagen , Hígado/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/etiología , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/patología , Protones
10.
Med Phys ; 49(5): 3159-3170, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35171511

RESUMEN

BACKGROUND: Most available four-dimensional (4D)-magnetic resonance imaging (MRI) techniques are limited by insufficient image quality and long acquisition times or require specially designed sequences or hardware that are not available in the clinic. These limitations have greatly hindered the clinical implementation of 4D-MRI. PURPOSE: This study aims to develop a fast ultra-quality (UQ) 4D-MRI reconstruction method using a commercially available 4D-MRI sequence and dual-supervised deformation estimation model (DDEM). METHODS: Thirty-nine patients receiving radiotherapy for liver tumors were included. Each patient was scanned using a time-resolved imaging with interleaved stochastic trajectories (TWIST)-lumetric interpolated breath-hold examination (VIBE) MRI sequence to acquire 4D-magnetic resonance (MR) images. They also received 3D T1-/T2-weighted MRI scans as prior images, and UQ 4D-MRI at any instant was considered a deformation of them. A DDEM was developed to obtain a 4D deformable vector field (DVF) from 4D-MRI data, and the prior images were deformed using this 4D-DVF to generate UQ 4D-MR images. The registration accuracies of the DDEM, VoxelMorph (normalized cross-correlation [NCC] supervised), VoxelMorph (end-to-end point error [EPE] supervised), and the parametric total variation (pTV) algorithm were compared. Tumor motion on UQ 4D-MRI was evaluated quantitatively using region of interest (ROI) tracking errors, while image quality was evaluated using the contrast-to-noise ratio (CNR), lung-liver edge sharpness, and perceptual blur metric (PBM). RESULTS: The registration accuracy of the DDEM was significantly better than those of VoxelMorph (NCC supervised), VoxelMorph (EPE supervised), and the pTV algorithm (all, p < 0.001), with an inference time of 69.3 ± 5.9 ms. UQ 4D-MRI yielded ROI tracking errors of 0.79 ± 0.65, 0.50 ± 0.55, and 0.51 ± 0.58 mm in the superior-inferior, anterior-posterior, and mid-lateral directions, respectively. From the original 4D-MRI to UQ 4D-MRI, the CNR increased from 7.25 ± 4.89 to 18.86 ± 15.81; the lung-liver edge full-width-at-half-maximum decreased from 8.22 ± 3.17 to 3.65 ± 1.66 mm in the in-plane direction and from 8.79 ± 2.78 to 5.04 ± 1.67 mm in the cross-plane direction, and the PBM decreased from 0.68 ± 0.07 to 0.38 ± 0.01. CONCLUSION: This novel DDEM method successfully generated UQ 4D-MR images based on a commercial 4D-MRI sequence. It shows great promise for improving liver tumor motion management during radiation therapy.


Asunto(s)
Neoplasias Hepáticas , Imagen por Resonancia Magnética , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Movimiento (Física)
11.
J Magn Reson Imaging ; 55(1): 126-137, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34169600

RESUMEN

BACKGROUND: Single-shot diffusion-weighted imaging (ssDWI) has been shown useful for detecting active bowel inflammation in Crohn's disease (CD) without MRI contrast. However, ssDWI suffers from geometric distortion and low spatial resolution. PURPOSE: To compare conventional ssDWI with higher-resolution ssDWI (HR-ssDWI) and multi-shot DWI based on multiplexed sensitivity encoding (MUSE-DWI) for evaluating bowel inflammation in CD, using contrast-enhanced MR imaging (CE-MRI) as the reference standard. STUDY TYPE: Prospective. SUBJECTS: Eighty nine patients with histological diagnosis of CD from previous endoscopy (55 male/34 female, age: 17-69 years). FIELD STRENGTH/SEQUENCES: ssDWI (2.7 mm × 2.7 mm), HR-ssDWI (1.8 mm × 1.8 mm), MUSE-DWI (1.8 mm × 1.8 mm) based on echo-planar imaging, T2-weighted imaging, and CE-MRI sequences, all at 1.5 T. ASSESSMENT: Five raters independently evaluated the tissue texture conspicuity, geometry accuracy, minimization of artifacts, diagnostic confidence, and overall image quality using 5-point Likert scales. The diagnostic performance (sensitivity, specificity and accuracy) of each DWI sequences was assessed on per-bowel-segment basis. STATISTICAL TESTS: Inter-rater agreement for qualitative evaluation of each parameter was measured by the intra-class correlation coefficient (ICC). Paired Wilcoxon signed-rank tests were performed to evaluate the statistical significance of differences in qualitative scoring between DWI sequences. A P value <0.05 was considered to be statistically significant. RESULTS: Tissue texture conspicuity, geometric distortions, and overall image quality were significantly better for MUSE-DWI than for ssDWI and HR-ssDWI with good agreement among five raters (ICC: 0.70-0.89). HR-ssDWI showed significantly poorer performance to ssDWI and MUSE-DWI for all qualitative scores and had the worst diagnostic performance (sensitivity of 57.0% and accuracy of 87.3%, with 36 undiagnosable cases due to severe artifacts). MUSE-DWI showed significantly higher sensitivity (97.5% vs. 86.1%) and accuracy (98.9% vs. 95.1%) than ssDWI for detecting bowel inflammation. DATA CONCLUSION: MUSE-DWI was advantageous in assessing bowel inflammation in CD, resulting in improved spatial resolution and image quality. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Enfermedad de Crohn , Adolescente , Adulto , Anciano , Enfermedad de Crohn/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Inflamación/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
12.
Tomography ; 7(4): 555-572, 2021 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-34698286

RESUMEN

In order to improve the image quality of BLADE magnetic resonance imaging (MRI) using the index tensor solvers and to evaluate MRI image quality in a clinical setting, we implemented BLADE MRI reconstructions using two tensor solvers (the least-squares solver and the L1 total-variation regularized least absolute deviation (L1TV-LAD) solver) on a graphics processing unit (GPU). The BLADE raw data were prospectively acquired and presented in random order before being assessed by two independent radiologists. Evaluation scores were examined for consistency and then by repeated measures analysis of variance (ANOVA) to identify the superior algorithm. The simulation showed the structural similarity index (SSIM) of various tensor solvers ranged between 0.995 and 0.999. Inter-reader reliability was high (Intraclass correlation coefficient (ICC) = 0.845, 95% confidence interval: 0.817, 0.87). The image score of L1TV-LAD was significantly higher than that of vendor-provided image and the least-squares method. The image score of the least-squares method was significantly lower than that of the vendor-provided image. No significance was identified in L1TV-LAD with a regularization strength of λ= 0.4-1.0. The L1TV-LAD with a regularization strength of λ= 0.4-0.7 was found consistently better than least-squares and vendor-provided reconstruction in BLADE MRI with a SENSitivity Encoding (SENSE) factor of 2. This warrants further development of the integrated computing system with the scanner.


Asunto(s)
Algoritmos , Imagen por Resonancia Magnética , Simulación por Computador , Análisis de los Mínimos Cuadrados , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados
13.
Sci Robot ; 6(57)2021 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-34408096

RESUMEN

Magnetic resonance (MR) imaging (MRI) provides compelling features for the guidance of interventional procedures, including high-contrast soft tissue imaging, detailed visualization of physiological changes, and thermometry. Laser-based tumor ablation stands to benefit greatly from MRI guidance because 3D resection margins alongside thermal distributions can be evaluated in real time to protect critical structures while ensuring adequate resection margins. However, few studies have investigated the use of projection-based lasers like those for transoral laser microsurgery, potentially because dexterous laser steering is required at the ablation site, raising substantial challenges in the confined MRI bore and its strong magnetic field. Here, we propose an MR-safe soft robotic system for MRI-guided transoral laser microsurgery. Owing to its miniature size (Ø12 × 100 mm), inherent compliance, and five degrees of freedom, the soft robot ensures zero electromagnetic interference with MRI and enables safe and dexterous operation within the confined oral and pharyngeal cavities. The laser manipulator is rapidly fabricated with hybrid soft and hard structures and is powered by microvolume (<0.004 milliter) fluid flow to enable laser steering with enhanced stiffness and lowered hysteresis. A learning-based controller accommodates the inherent nonlinear robot actuation, which was validated with laser path-following tests. Submillimeter laser steering accuracy was demonstrated with a mean error < 0.20 mm. MRI compatibility testing demonstrated zero observable image artifacts during robot operation. Ex vivo tissue ablation and a cadaveric head-and-neck trial were carried out under MRI, where we employed MR thermometry to monitor the tissue ablation margin and thermal diffusion intraoperatively.


Asunto(s)
Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/cirugía , Imagen por Resonancia Magnética/métodos , Microcirugia/métodos , Artefactos , Cadáver , Difusión , Diseño de Equipo , Calor , Humanos , Imagenología Tridimensional , Terapia por Láser , Rayos Láser , Aprendizaje , Redes Neurales de la Computación , Distribución Normal , Fantasmas de Imagen , Procedimientos Quirúrgicos Robotizados , Robótica , Cirugía Bucal/métodos , Termometría/métodos
14.
J Vis Exp ; (173)2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-34279507

RESUMEN

Brown and beige adipocytes are now recognized as potential therapeutic targets for obesity and metabolic syndromes. Non-invasive molecular imaging methods are essential to provide critical insights into these thermogenic adipose depots. Here, the protocol presents a PET/MR imaging-based method to evaluate the activity of brown and beige adipocytes in mouse interscapular brown adipose tissue (iBAT) and inguinal subcutaneous white adipose tissue (iWAT). Visualization and quantification of the thermogenic adipose depots were achieved using [18F]FDG, the non-metabolizable glucose analog, as the radiotracer, when combined with the precise anatomical information provided by MR imaging. The PET/MR imaging was conducted 7 days after cold acclimation and quantitation of [18F]FDG signal in different adipose depots was conducted to assess the relative mobilization of thermogenic adipose tissues. Removal of iBAT substantially increased cold-evoked [18F]FDG uptake in iWAT of the mice.


Asunto(s)
Tejido Adiposo Beige , Fluorodesoxiglucosa F18 , Tejido Adiposo Pardo/diagnóstico por imagen , Tejido Adiposo Blanco , Animales , Imagen por Resonancia Magnética , Ratones , Tomografía de Emisión de Positrones
15.
BMC Psychiatry ; 21(1): 46, 2021 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-33461506

RESUMEN

BACKGROUND: Video gaming is a promising intervention for cognitive and social impairment in patients with schizophrenia. A number of gaming interventions have been evaluated in small-scale studies with various patient groups, but studies on patients with schizophrenia remain scarce and rarely include the evaluation of both clinical and neurocognitive outcomes. In this study, we will test the effectiveness of two interventions with gaming elements to improve cognitive and clinical outcomes among persons with schizophrenia. METHODS: The participants will be recruited from different outpatient units (e.g., outpatient psychiatric units, day hospitals, residential care homes). The controlled clinical trial will follow a three-arm parallel-group design: 1) cognitive training (experimental group, CogniFit), 2) entertainment gaming (active control group, SIMS 4), and 3) treatment as usual. The primary outcomes are working memory function at 3-month and 6-month follow-ups. The secondary outcomes are patients' other cognitive and social functioning, the ability to experience pleasure, self-efficacy, and negative symptoms at 3-month and 6-month follow-ups. We will also test the effectiveness of gaming interventions on neurocognitive outcomes (EEG and 3 T MRI plus rs-fMRI) at a 3-month follow-up as an additional secondary outcome. Data will be collected in outpatient psychiatric services in Hong Kong. Participants will have a formal diagnosis of schizophrenia and be between 18 and 60 years old. We aim to have a total of 234 participants, randomly allocated to the three arms. A sub-sample of patients (N = 150) will be recruited to undergo an EEG. For neuroimaging assessment, patients will be randomly allocated to a subset of patients (N=126). We will estimate the efficacy of the interventions on the primary and secondary outcomes based on the intention-to-treat principle. Behavioural and EEG data will be analysed separately. DISCUSSION: The study will characterise benefits of gaming on patients' health and well-being, and contribute towards the development of new treatment approaches for patients with schizophrenia. TRIAL REGISTRATION: ClinicalTrials.gov NCT03133143 . Registered on April 28, 2017.


Asunto(s)
Esquizofrenia , Juegos de Video , Adolescente , Adulto , Cognición , Centros de Día , Hong Kong , Humanos , Persona de Mediana Edad , Ensayos Clínicos Controlados Aleatorios como Asunto , Esquizofrenia/complicaciones , Esquizofrenia/terapia , Resultado del Tratamiento , Adulto Joven
16.
Insights Imaging ; 11(1): 128, 2020 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-33252711

RESUMEN

BACKGROUND: Time-efficient and accurate whole volume thigh muscle segmentation is a major challenge in moving from qualitative assessment of thigh muscle MRI to more quantitative methods. This study developed an automated whole thigh muscle segmentation method using deep learning for reproducible fat fraction quantification on fat-water decomposition MRI. RESULTS: This study was performed using a public reference database (Dataset 1, 25 scans) and a local clinical dataset (Dataset 2, 21 scans). A U-net was trained using 23 scans (16 from Dataset 1, seven from Dataset 2) to automatically segment four functional muscle groups: quadriceps femoris, sartorius, gracilis and hamstring. The segmentation accuracy was evaluated on an independent testing set (3 × 3 repeated scans in Dataset 1 and four scans in Dataset 2). The average Dice coefficients between manual and automated segmentation were > 0.85. The average percent difference (absolute) in volume was 7.57%, and the average difference (absolute) in mean fat fraction (meanFF) was 0.17%. The reproducibility in meanFF was calculated using intraclass correlation coefficients (ICCs) for the repeated scans, and automated segmentation produced overall higher ICCs than manual segmentation (0.921 vs. 0.902). A preliminary quantitative analysis was performed using two-sample t test to detect possible differences in meanFF between 14 normal and 14 abnormal (with fat infiltration) thighs in Dataset 2 using automated segmentation, and significantly higher meanFF was detected in abnormal thighs. CONCLUSIONS: This automated thigh muscle segmentation exhibits excellent accuracy and higher reproducibility in fat fraction estimation compared to manual segmentation, which can be further used for quantifying fat infiltration in thigh muscles.

17.
NMR Biomed ; 33(5): e4282, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32124504

RESUMEN

The aim of this study was to evaluate the imaging quality and diagnostic performance of fast spin echo diffusion-weighted imaging with periodically rotated overlapping parallel lines with enhanced reconstruction (FSE-PROP-DWI) in distinguishing parotid pleomorphic adenoma (PMA) from Warthin tumor (WT). This retrospective study enrolled 44 parotid gland tumors from 34 patients, including 15 PMAs and 29 WTs with waived written informed consent. All participants underwent 1.5 T diffusion-weighted imaging including FSE-PROP-DWI and single-shot echo-planar diffusion-weighted imaging (SS-EP-DWI). After imaging resizing and registration among T2WI, FSE-PROP-DWI and SS-EP-DWI, imaging distortion was quantitatively analyzed by using the Dice coefficient. Signal-to-noise ratio and contrast-to-noise ratio were qualitatively evaluated. The mean apparent diffusion coefficient (ADC) of parotid gland tumors was calculated. Wilcoxon signed-rank test was used for paired comparison between FSE-PROP-DWI versus SS-EP-DWI. Mann-Whitney U test was used for independent group comparison between PMAs versus WTs. Diagnostic performance was evaluated by receiver operating characteristics curve analysis. P < 0.05 was considered statistically significant. The Dice coefficient was statistically significantly higher on FSE-PROP-DWI than SS-EP-DWI for both tumors (P < 0.005). Mean ADC was statistically significantly higher in PMAs than WTs on both FSE-PROP-DWI and SS-EP-DWI (P < 0.005). FSE-PROP-DWI and SS-EP-DWI successfully distinguished PMAs from WTs with an AUC of 0.880 and 0.945, respectively (P < 0.05). Sensitivity, specificity, positive predictive value, negative predictive value and accuracy in diagnosing PMAs were 100%, 69.0%, 62.5%, 100% and 79.5% for FSE-PROP-DWI, and 100%, 82.8%, 75%, 100% and 88.6% for SS-EP-DWI, respectively. FSE-PROP-DWI is useful to distinguish parotid PMAs from WTs with less distortion of tumors but lower AUC than SS-EP-DWI.


Asunto(s)
Adenolinfoma/diagnóstico por imagen , Adenolinfoma/diagnóstico , Adenoma Pleomórfico/diagnóstico por imagen , Adenoma Pleomórfico/diagnóstico , Imagen de Difusión por Resonancia Magnética , Neoplasias de la Parótida/diagnóstico por imagen , Neoplasias de la Parótida/diagnóstico , Neoplasias de las Glándulas Salivales/diagnóstico por imagen , Neoplasias de las Glándulas Salivales/diagnóstico , Diagnóstico Diferencial , Humanos , Procesamiento de Imagen Asistido por Computador , Curva ROC , Procesamiento de Señales Asistido por Computador , Relación Señal-Ruido
18.
Korean J Radiol ; 21(2): 218-227, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31997597

RESUMEN

OBJECTIVE: This study aimed to find the optimal number of b-values for intravoxel incoherent motion (IVIM) imaging analysis, using simulated and in vivo data from cervical cancer patients. MATERIALS AND METHODS: Simulated data were generated using literature pooled means, which served as reference values for simulations. In vivo data from 100 treatment-naïve cervical cancer patients with IVIM imaging (13 b-values, scan time, 436 seconds) were retrospectively reviewed. A stepwise b-value fitting algorithm calculated optimal thresholds. Feed forward selection determined the optimal subsampled b-value distribution for biexponential IVIM fitting, and simplified IVIM modeling using monoexponential fitting was attempted. IVIM parameters computed using all b-values served as reference values for in vivo data. RESULTS: In simulations, parameters were accurately estimated with six b-values, or three b-values for simplified IVIM, respectively. In vivo data showed that the optimal threshold was 40 s/mm² for patients with squamous cell carcinoma and a subsampled acquisition of six b-values (scan time, 198 seconds) estimated parameters were not significantly different from reference parameters (individual parameter error rates of less than 5%). In patients with adenocarcinoma, the optimal threshold was 100 s/mm², but an optimal subsample could not be identified. Irrespective of the histological subtype, only three b-values were needed for simplified IVIM, but these parameters did not retain their discriminative ability. CONCLUSION: Subsampling of six b-values halved the IVIM scan time without significant losses in accuracy and discriminative ability. Simplified IVIM is possible with only three b-values, at the risk of losing diagnostic information.


Asunto(s)
Adenocarcinoma/patología , Carcinoma de Células Escamosas/patología , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias del Cuello Uterino/patología , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Retrospectivos , Relación Señal-Ruido , Adulto Joven
19.
J Magn Reson Imaging ; 51(5): 1442-1453, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31664772

RESUMEN

BACKGROUND: Single-shot diffusion-weighted echo-planar imaging (ssDW-EPI) acquired with parallel imaging and a multi-oblique scan plane may suffer from residual aliasing artifacts, resembling lesions on the calculated apparent diffusion coefficient (ADC) map. PURPOSE: To combine ssDW-EPI and virtual coil acquisition and develop a self-reference reconstruction method to eliminate the residual aliasing artifact on multi-oblique ssDW-EPI sequence with parallel imaging and multiple signal averaging. STUDY TYPE: Prospective. SUBJECTS: Three healthy subjects and 50 stroke patients. FIELD STRENGTH/SEQUENCE: Conventional ssDW-EPI with parallel imaging, and proposed ssDW-EPI with virtual coil acquisition at 1.5T. ASSESSMENT: The efficacy of the proposed method was evaluated in 50 stroke patients by comparing the ssDW-EPI with conventional parallel imaging reconstructions. The extent of residual aliasing artifacts were rated on a 5-point Likert scale by three independent raters. Only the data without residual aliasing artifacts on conventional ssDW-EPI were included for the assessment of signal-to-noise ratio (SNR), ghost-to-signal ratio (GSR), and ADC. STATISTICAL TESTS: The interobserver agreements for examining residual aliasing artifacts were measured by the intraclass correlation coefficient (ICC). A two-sample t-test was performed for comparing SNR, GSR, and ADC. RESULTS: There was a perfect agreement (ICC = 1.00) in the examination of residual aliasing artifacts on images obtained using the proposed method. The incidence rates of the residual aliasing artifact on the ADC maps obtained from the scanner console and proposed method were 60% (ie, 30 out of 50) and 0%, respectively. The proposed method offers significantly lower GSR than conventional parallel imaging reconstruction (P < 0.001). There was no significant difference in SNR (P = 0.20-0.51) and ADC values (P = 0.20-0.94) between conventional parallel imaging reconstructions and the proposed method. DATA CONCLUSION: It appears that our method could effectively eliminate artifacts and significantly improve the GSR of b = 0 T2 WI and b > 0 DWI, as well as permit ADC measurement consistent with conventional techniques. Our method may be beneficial to clinical assessment of the brain that utilizes multi-oblique ssDW-EPI. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:1442-1453.


Asunto(s)
Artefactos , Imagen Eco-Planar , Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Humanos , Estudios Prospectivos
20.
Eur J Radiol ; 117: 56-61, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31307653

RESUMEN

PURPOSE: The purpose of this retrospective study was to investigate the differentiation of abscess and necrotic tumors, using susceptibility-weighted imaging (SWI) and apparent diffusion coefficients (ADC) either separated or combined. METHODS: Imaging was performed on 26 patients with pyogenic brain abscesses, 31 patients with rim-enhancing glioblastomas, and 21 patients with rim-enhancing metastases. The degree of intralesional susceptibility signal (ILSS) was independently assessed by three observers. Average ADC in the lesion core was calculated. After receiver operating characteristic (ROC) analysis, the area under the ROC curve was compared using three different analytical models (ILSS, ADC, and ILSS-ADC combined) to differentiate abscess from the two rim-enhancing necrotic tumors. RESULTS: The ILSS-ADC combined model had greater area under the ROC curves than ILSS or ADC used alone. In this study, the ILSS-ADC combined model showed 100% diagnostic accuracy differentiating abscesses from glioblastoma. The ADC model and the ILSS-ADC combined model performed equally well in distinguishing abscesses from metastases. CONCLUSION: It is concluded that SWI and ADC are complementary, and the combination of SWI and ADC may improve results compared with the use of only one model. Validation by an independent cohort is the next necessary step to broaden its applicability in routine clinical settings.


Asunto(s)
Absceso Encefálico/diagnóstico por imagen , Neoplasias Encefálicas/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Glioblastoma/diagnóstico por imagen , Necrosis/diagnóstico por imagen , Adulto , Anciano , Absceso Encefálico/patología , Neoplasias Encefálicas/patología , Diagnóstico Diferencial , Imagen de Difusión por Resonancia Magnética/métodos , Femenino , Glioblastoma/patología , Humanos , Masculino , Persona de Mediana Edad , Necrosis/patología , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...