Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 236
Filtrar
1.
Int J Med Sci ; 21(4): 656-663, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38464824

RESUMEN

Purpose: With advances in medical technology, the average lifespan has increased, leading to a growing significance of idiopathic normal pressure hydrocephalus (iNPH), particularly in the elderly population. Most patients with iNPH have been treated either with ventriculo-peritoneal shunts (VPS) or conservative measures. However, lumbo-peritoneal shunts (LPS) have emerged as an alternative treatment option for iNPH in recent decades, extensive research still lacks comparing outcomes with LPS to those with VPS or non-surgical treatment. The aim of the resent study is to disclose the long-term therapeutic outcomes of LPS, VPS, and non-shunting in patients with iNPH. Methods: We used the National Health Insurance Research Database in Taiwan to assess the long-term outcomes of these treatment options. We enrolled 5,537 iNPH patients who received shunting surgery, of which 5,254 were VPS and 283 were LPS. To compare the difference between each group, matching was conducted by propensity score matching using a 1:1 ratio based on LPS patients. Primary outcomes included death and major adverse cardiovascular events (MACEs) Results: Our findings show that VPS resulted in significantly more MACEs than non-surgical treatment (Odds ratio: 1.83, 95% confidence interval: 1.16-2.90). In addition, both VPS and LPS groups had significantly lower overall mortality rates than non-shunting group. Moreover, LPS had lower overall mortality but similar MACEs rates to VPS. Conclusions: Based on these findings, we propose that the LPS is preferable to the VPS, and surgical treatment should be considered the primary choice over conservative treatment unless contraindications are present.


Asunto(s)
Hidrocéfalo Normotenso , Humanos , Anciano , Hidrocéfalo Normotenso/epidemiología , Hidrocéfalo Normotenso/cirugía , Estudios Retrospectivos , Lipopolisacáridos , Derivación Ventriculoperitoneal/efectos adversos , Derivación Ventriculoperitoneal/métodos , Procedimientos Quirúrgicos Vasculares , Resultado del Tratamiento
2.
Artículo en Inglés | MEDLINE | ID: mdl-38368191

RESUMEN

BACKGROUND: Clinical quality registries (CQRs) are intended to enhance quality, safety, and cost reduction using real-world data for a self-improving health system. Starting in 2001, Kaiser Permanente established several medical device CQRs as a quality improvement initiative. This report examines the contributions of these CQRs on improvement in health outcomes, changes in clinical practice, and cost-effectiveness over the past 20 years. METHODS: Eight implant registries were instituted with standardized collection from the electronic health record and other institutional data sources of patient characteristics, medical comorbidities, implant attributes, procedure details, surgical techniques, and outcomes (including complications, revisions, reoperations, hospital readmissions, and other utilization measures). A rigorous quality control system is in place to improve and maintain the quality of data. Data from the Implant Registries form the basis for multiple quality improvement and patient safety initiatives to minimize variation in care, promote clinical best practices, facilitate recalls, perform benchmarking, identify patients at risk, and construct reports about individual surgeons. RESULTS: Following the inception of the Implant Registries, there was an observed (1) reduction in opioid utilization following orthopedic procedures, (2) reduction in use of bone morphogenic protein during lumbar fusion allowing for cost savings, (3) reduction in allograft for anterior cruciate ligament reconstruction and subsequent decrease in organizationwide revision rates, (4) cost savings through expansion of same-day discharge programs for joint arthroplasty, (5) increase in the use of cement fixation in the hemiarthroplasty treatment of hip fracture, and (6) organizationwide discontinuation of an endograft device associated with a higher risk for adverse outcomes following endovascular aortic aneurysm repair. CONCLUSION: The use of Implant Registries within our health system, along with clinical leadership and organizational commitment to a learning health system, was associated with improved quality and safety outcomes and reduced costs. The exact mechanisms by which such registries affect health outcomes and costs require further study.

3.
J Vasc Surg ; 79(2): 451-452, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38245187
4.
Global Spine J ; : 21925682231219224, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-38047537

RESUMEN

STUDY DESIGN: Systematic Review and Meta-analysis. OBJECTIVE: The purpose of this study was to evaluate whether transcranial motor evoked potential (TcMEP) alarms can predict postoperative neurologic complications in patients undergoing cervical spine decompression surgery. METHODS: A meta-analysis of the literature was performed using PubMed, Web of Science, and Embase to retrieve published reports on intraoperative TcMEP monitoring for patients undergoing cervical spine decompression surgery. The sensitivity, specificity, and diagnostic odds ratio (DOR), of overall, reversible, and irreversible TcMEP changes for predicting postoperative neurological deficit were calculated. A subgroup analysis was performed to compare anterior vs posterior approaches. RESULTS: Nineteen studies consisting of 4608 patients were analyzed. The overall incidence of postoperative neurological deficits was 2.58% (119/4608). Overall TcMEP changes had a sensitivity of 56%, specificity of 94%, and DOR of 19.26 for predicting deficit. Reversible and irreversible changes had sensitivities of 16% and 49%, specificities of 95% and 98%, and DORs of 3.54 and 71.74, respectively. In anterior procedures, TcMEP changes had a DOR of 17.57, sensitivity of 49%, and specificity of 94%. In posterior procedures, TcMEP changes had a DOR of 21.01, sensitivity of 55%, and specificity of 94%. CONCLUSION: TcMEP monitoring has high specificity but low sensitivity for predicting postoperative neurological deficit in cervical spine decompression surgery. Patients with new postoperative neurological deficits were 19 times more likely to have experienced intraoperative TcMEP changes than those without new deficits, with irreversible TcMEP changes indicating a much higher risk of deficit than reversible TcMEP changes.

5.
Br J Ophthalmol ; 2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37857452

RESUMEN

BACKGROUND: Deep learning (DL) is promising to detect glaucoma. However, patients' privacy and data security are major concerns when pooling all data for model development. We developed a privacy-preserving DL model using the federated learning (FL) paradigm to detect glaucoma from optical coherence tomography (OCT) images. METHODS: This is a multicentre study. The FL paradigm consisted of a 'central server' and seven eye centres in Hong Kong, the USA and Singapore. Each centre first trained a model locally with its own OCT optic disc volumetric dataset and then uploaded its model parameters to the central server. The central server used FedProx algorithm to aggregate all centres' model parameters. Subsequently, the aggregated parameters are redistributed to each centre for its local model optimisation. We experimented with three three-dimensional (3D) networks to evaluate the stabilities of the FL paradigm. Lastly, we tested the FL model on two prospectively collected unseen datasets. RESULTS: We used 9326 volumetric OCT scans from 2785 subjects. The FL model performed consistently well with different networks in 7 centres (accuracies 78.3%-98.5%, 75.9%-97.0%, and 78.3%-97.5%, respectively) and stably in the 2 unseen datasets (accuracies 84.8%-87.7%, 81.3%-84.8%, and 86.0%-87.8%, respectively). The FL model achieved non-inferior performance in classifying glaucoma compared with the traditional model and significantly outperformed the individual models. CONCLUSION: The 3D FL model could leverage all the datasets and achieve generalisable performance, without data exchange across centres. This study demonstrated an OCT-based FL paradigm for glaucoma identification with ensured patient privacy and data security, charting another course toward the real-world transition of artificial intelligence in ophthalmology.

6.
Cell ; 186(22): 4868-4884.e12, 2023 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-37863056

RESUMEN

Single-cell analysis in living humans is essential for understanding disease mechanisms, but it is impractical in non-regenerative organs, such as the eye and brain, because tissue biopsies would cause serious damage. We resolve this problem by integrating proteomics of liquid biopsies with single-cell transcriptomics from all known ocular cell types to trace the cellular origin of 5,953 proteins detected in the aqueous humor. We identified hundreds of cell-specific protein markers, including for individual retinal cell types. Surprisingly, our results reveal that retinal degeneration occurs in Parkinson's disease, and the cells driving diabetic retinopathy switch with disease stage. Finally, we developed artificial intelligence (AI) models to assess individual cellular aging and found that many eye diseases not associated with chronological age undergo accelerated molecular aging of disease-specific cell types. Our approach, which can be applied to other organ systems, has the potential to transform molecular diagnostics and prognostics while uncovering new cellular disease and aging mechanisms.


Asunto(s)
Envejecimiento , Humor Acuoso , Inteligencia Artificial , Biopsia Líquida , Proteómica , Humanos , Envejecimiento/metabolismo , Humor Acuoso/química , Biopsia , Enfermedad de Parkinson/diagnóstico
7.
J Vis Exp ; (199)2023 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-37747194

RESUMEN

A critical challenge in translational research is establishing a viable and efficient interface between patient care in the operating room (OR) and the research laboratory. Here, we developed a protocol for acquiring high-quality liquid biopsies for molecular analyses from the aqueous humor and the vitreous from patients undergoing eye surgery. In this workflow, a Mobile Operating Room Lab Interface (MORLI) cart equipped with a computer, a barcode scanner, and lab instruments, including onboard cold storage, is used to obtain and archive human biological samples. A web-based data privacy-compliant database enables annotating each sample over its lifetime, and a cartesian coordinate system allows tracking each barcoded specimen in storage, enabling quick and accurate retrieval of samples for downstream analyses. Molecular characterization of human tissue samples not only serves as a diagnostic tool (e.g., to distinguish between infectious endophthalmitis and other non-infectious intraocular inflammation) but also represents an important component of translational research, allowing the identification of new drug targets, development of new diagnostic tools, and personalized therapeutics.


Asunto(s)
Bancos de Muestras Biológicas , Endoftalmitis , Humanos , Cuerpo Vítreo , Humor Acuoso , Biopsia Líquida
8.
Heliyon ; 9(8): e18703, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37576221

RESUMEN

Purpose: To compare intraocular pressure (IOP) obtained with Tono-Pen (TP) and Goldmann applanation (GAT) using large-scale electronic health records (EHR). Design: Retrospective cohort study. Methods: A single pair of eligible TP/GAT IOP readings was randomly selected from the EHR for each ophthalmology patient at an academic ophthalmology center (2013-2022), yielding 4550 eligible measurements. We used Bland-Altman analysis to describe agreement between TP/GAT IOP differences and mean IOP measurements. We also used multivariable logistic regression to identify factors associated with different IOP readings in the same eye, including demographics, glaucoma diagnosis, and central corneal thickness (CCT). Primary outcome metrics were discrepant measurements between TP and GAT as defined by two methods: Outcome A (normal TP despite elevated GAT measurements), and Outcome B (TP and GAT IOP differences ≥6 mmHg). Result: The mean TP/GAT IOP difference was 0.15 mmHg ( ± 5.49 mmHg 95% CI). There was high correlation between the measurements (r = 0.790, p < 0.001). We found that TP overestimated pressures at IOP <16.5 mmHg and underestimated at IOP >16.5 mmHg (Fig. 4). Discrepant measurements accounted for 2.6% (N = 116) and 5.2% (N = 238) for outcomes A and B respectively. Patients with thinner CCT had higher odds of discrepant IOP (OR 0.88 per 25 µm increase, CI [0.84-0.92], p < 0.0001; OR 0.88 per 25 µm increase, CI [0.84-0.92], p < 0.0001 for outcomes A and B respectively). Conclusion: In a real-world academic practice setting, TP and GAT IOP measurements demonstrated close agreement, although 2.6% of measurements showed elevated GAT IOP despite normal TP measurements, and 5.2% of measurements were ≥6 mmHg apart.

9.
JAMA Netw Open ; 6(8): e2330320, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37606922

RESUMEN

Importance: Large language models (LLMs) like ChatGPT appear capable of performing a variety of tasks, including answering patient eye care questions, but have not yet been evaluated in direct comparison with ophthalmologists. It remains unclear whether LLM-generated advice is accurate, appropriate, and safe for eye patients. Objective: To evaluate the quality of ophthalmology advice generated by an LLM chatbot in comparison with ophthalmologist-written advice. Design, Setting, and Participants: This cross-sectional study used deidentified data from an online medical forum, in which patient questions received responses written by American Academy of Ophthalmology (AAO)-affiliated ophthalmologists. A masked panel of 8 board-certified ophthalmologists were asked to distinguish between answers generated by the ChatGPT chatbot and human answers. Posts were dated between 2007 and 2016; data were accessed January 2023 and analysis was performed between March and May 2023. Main Outcomes and Measures: Identification of chatbot and human answers on a 4-point scale (likely or definitely artificial intelligence [AI] vs likely or definitely human) and evaluation of responses for presence of incorrect information, alignment with perceived consensus in the medical community, likelihood to cause harm, and extent of harm. Results: A total of 200 pairs of user questions and answers by AAO-affiliated ophthalmologists were evaluated. The mean (SD) accuracy for distinguishing between AI and human responses was 61.3% (9.7%). Of 800 evaluations of chatbot-written answers, 168 answers (21.0%) were marked as human-written, while 517 of 800 human-written answers (64.6%) were marked as AI-written. Compared with human answers, chatbot answers were more frequently rated as probably or definitely written by AI (prevalence ratio [PR], 1.72; 95% CI, 1.52-1.93). The likelihood of chatbot answers containing incorrect or inappropriate material was comparable with human answers (PR, 0.92; 95% CI, 0.77-1.10), and did not differ from human answers in terms of likelihood of harm (PR, 0.84; 95% CI, 0.67-1.07) nor extent of harm (PR, 0.99; 95% CI, 0.80-1.22). Conclusions and Relevance: In this cross-sectional study of human-written and AI-generated responses to 200 eye care questions from an online advice forum, a chatbot appeared capable of responding to long user-written eye health posts and largely generated appropriate responses that did not differ significantly from ophthalmologist-written responses in terms of incorrect information, likelihood of harm, extent of harm, or deviation from ophthalmologist community standards. Additional research is needed to assess patient attitudes toward LLM-augmented ophthalmologists vs fully autonomous AI content generation, to evaluate clarity and acceptability of LLM-generated answers from the patient perspective, to test the performance of LLMs in a greater variety of clinical contexts, and to determine an optimal manner of utilizing LLMs that is ethical and minimizes harm.


Asunto(s)
Inteligencia Artificial , Oftalmólogos , Humanos , Estudios Transversales , Programas Informáticos , Lenguaje
10.
J Vasc Surg ; 78(5): 1239-1247.e4, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37406943

RESUMEN

OBJECTIVE: The results of current prospective trials comparing the effectiveness of carotid endarterectomy (CEA) vs standard medical therapy for long-term stroke prevention in patients with asymptomatic carotid stenosis (ACS) will not be available for several years. In this study, we compared the observed effectiveness of CEA and standard medical therapy vs standard medical therapy alone to prevent ipsilateral stroke in a contemporary cohort of patients with ACS. METHODS: This cohort study was conducted in a large integrated health system in adult subjects with 70% to 99% ACS (no neurologic symptom within 6 months) with no prior ipsilateral carotid artery intervention. Causal inference methods were used to emulate a conceptual randomized trial using data from January 1, 2008, through December 31, 2017, for comparing the event-free survival over 96 months between two treatment strategies: (1) CEA within 12 months from cohort entry vs (2) no CEA (standard medical therapy alone). To account for both baseline and time-dependent confounding, inverse probability weighting estimation was used to derive adjusted hazard ratios, and cumulative risk differences were assessed based on two logistic marginal structural models for counterfactual hazards. Propensity scores were data-adaptively estimated using super learning. The primary outcome was ipsilateral anterior ischemic stroke. RESULTS: The cohort included 3824 eligible patients with ACS (mean age: 73.7 years, 57.9% male, 12.3% active smokers), of whom 1467 underwent CEA in the first year, whereas 2297 never underwent CEA. The median follow-up was 68 months. A total of 1760 participants (46%) died, 445 (12%) were lost to follow-up, and 158 (4%) experienced ipsilateral stroke. The cumulative risk differences for each year of follow-up showed a protective effect of CEA starting in year 2 (risk difference = 1.1%, 95% confidence interval: 0.5%-1.6%) and persisting to year 8 (2.6%, 95% confidence interval: 0.3%-4.8%) compared with patients not receiving CEA. CONCLUSIONS: In this contemporary cohort study of patients with ACS using rigorous analytic methodology, CEA appears to have a small but statistically significant effect on stroke prevention out to 8 years. Further study is needed to appropriately select the subset of patients most likely to benefit from intervention.


Asunto(s)
Estenosis Carotídea , Prestación Integrada de Atención de Salud , Endarterectomía Carotidea , Accidente Cerebrovascular , Humanos , Masculino , Anciano , Femenino , Constricción Patológica/complicaciones , Estudios de Cohortes , Factores de Riesgo , Resultado del Tratamiento , Estenosis Carotídea/complicaciones , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/terapia , Endarterectomía Carotidea/efectos adversos , Arterias Carótidas , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Medición de Riesgo
11.
J Cataract Refract Surg ; 49(7): 764, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37390324

RESUMEN

A 62-year-old woman with mild myopia presented to her local optometrist for a routine examination and was found to have intraocular pressure (IOP) of 30 mm Hg in both eyes and cupped nerves. She had a family history of glaucoma in her father. She was started on latanoprost in both eyes and was referred for a glaucoma evaluation. On initial evaluation, her IOP was 25 mm Hg in the right eye and 26 mm Hg in the left eye. Central corneal thickness measured 592 µm in the right eye and 581 µm in the left eye. Her angles were open to gonioscopy without any peripheral anterior synechia. She had 1+ nuclear sclerosis with a corrected distance visual acuity (CDVA) of 20/25 in the right eye and 20/30- in the left eye and uncorrected near visual acuity of J1+ in each eye. Her nerves were 0.85 mm in the right eye and 0.75 mm in the left eye. Optical coherence tomography (OCT) showed retinal nerve fiber layer thinning and a dense superior arcuate scotoma into fixation in her right eye, and superior and inferior arcuate scotomas in her left eye (Figures 1 and 2JOURNAL/jcrs/04.03/02158034-202307000-00019/figure1/v/2023-06-26T195222Z/r/image-tiffJOURNAL/jcrs/04.03/02158034-202307000-00019/figure2/v/2023-06-26T195222Z/r/image-tiff, Supplemental Figures 1 and 2, available at http://links.lww.com/JRS/A882 and http://links.lww.com/JRS/A883). She was successively trialed on fixed combination brimonidine-timolol, dorzolamide, and netarsudil, in addition to her latanoprost, but her IOP remained in the mid- to upper 20s in both eyes. The addition of acetazolamide lowered the pressure to 19 mm Hg in both eyes, but she tolerated it poorly. Methazolamide was also attempted with similar side effects. We elected to perform left eye cataract surgery combined with 360-degree viscocanaloplasty and insertion of a Hydrus microstent (Alcon Laboratories, Inc.). Surgery was uncomplicated with IOP of 16 mm Hg on postoperative day 1 with no glaucoma medications. However, by postoperative week 3, IOP returned to 27 mm Hg, and despite restarting latanoprost-netarsudil and finishing her steroid taper, IOP remained at 27 mm Hg by postoperative week 6. Brimonidine-timolol was added back to her left eye regimen and at postoperative week 8, IOP had elevated to 45 mm Hg. Maximizing her therapy with the addition of topical dorzolamide and oral methazolamide brought her IOP back down to 30 mm Hg. At that point, the decision was made to proceed with trabeculectomy of the left eye. The trabeculectomy was uneventful. However, postoperative attempts to augment filtration were rendered less successful by extremely thick Tenon layer. At her most recent follow-up the pressure in the left eye was mid-teens with brimonidine-timolol and dorzolamide. Her right eye IOP is in the upper 20s on maximum topical therapy. Knowing her postoperative course in the left eye, how would you manage the right eye? In addition to currently available options, would you consider a supraciliary shunt such as the MINIject (iSTAR) if such a device were U.S. Food and Drug Administration (FDA)-approved?


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Humanos , Estados Unidos , Femenino , Adolescente , Persona de Mediana Edad , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Glaucoma de Ángulo Abierto/cirugía , Latanoprost/uso terapéutico , Metazolamida , Timolol/uso terapéutico , Resultado del Tratamiento
12.
Diagnostics (Basel) ; 13(11)2023 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-37296715

RESUMEN

BACKGROUND: Lumbar degenerative disc disease (LDDD) is a leading cause of chronic lower back pain; however, a lack of clear diagnostic criteria and solid LDDD interventional therapies have made predicting the benefits of therapeutic strategies challenging. Our goal is to develop machine learning (ML)-based radiomic models based on pre-treatment imaging for predicting the outcomes of lumbar nucleoplasty (LNP), which is one of the interventional therapies for LDDD. METHODS: The input data included general patient characteristics, perioperative medical and surgical details, and pre-operative magnetic resonance imaging (MRI) results from 181 LDDD patients receiving lumbar nucleoplasty. Post-treatment pain improvements were categorized as clinically significant (defined as a ≥80% decrease in the visual analog scale) or non-significant. To develop the ML models, T2-weighted MRI images were subjected to radiomic feature extraction, which was combined with physiological clinical parameters. After data processing, we developed five ML models: support vector machine, light gradient boosting machine, extreme gradient boosting, extreme gradient boosting random forest, and improved random forest. Model performance was measured by evaluating indicators, such as the confusion matrix, accuracy, sensitivity, specificity, F1 score, and area under the receiver operating characteristic curve (AUC), which were acquired using an 8:2 allocation of training to testing sequences. RESULTS: Among the five ML models, the improved random forest algorithm had the best performance, with an accuracy of 0.76, a sensitivity of 0.69, a specificity of 0.83, an F1 score of 0.73, and an AUC of 0.77. The most influential clinical features included in the ML models were pre-operative VAS and age. In contrast, the most influential radiomic features had the correlation coefficient and gray-scale co-occurrence matrix. CONCLUSIONS: We developed an ML-based model for predicting pain improvement after LNP for patients with LDDD. We hope this tool will provide both doctors and patients with better information for therapeutic planning and decision-making.

13.
BMJ Open ; 13(6): e069702, 2023 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-37344116

RESUMEN

OBJECTIVES: To investigate incident cataract surgery and to investigate determinants of cataract surgery uptake in Chinese adults. DESIGN: This nationally representative longitudinal study recorded self-reported incident cataract surgery, and measured biological, clinical and socioeconomical characteristics at baseline and endline. SETTING: In the first stage, 150 county-level units were randomly chosen with a probability-proportional-to-size sampling technique from a sampling frame containing all county-level units. The sample was stratified by region and within region by urban district or rural county and per capita gross domestic product. The final sample of 150 counties fell within 28 provinces of China. PARTICIPANTS: Urban and rural Chinese persons aged 45 years and older. PRIMARY AND SECONDARY OUTCOME MEASURES: Incident cataract surgery (primary outcome) and the factors associated with incident cataract surgery (secondary outcome). RESULTS: Among 16 663 people enrolled in 2011, 13 705 (82.2%) attended follow-up in 2015. Among these, 167 (1.22%) reported incident cataract surgery. Those receiving surgery were significantly older (66.2±8.79 vs 58.3±9.18, p≤0.001) and more likely to report: illiteracy (44.9% vs 27.1%, p<0.001), poor baseline distance vision (49.7% vs 20.0%, p≤0.001), poor baseline near vision (37.1% vs 21.8%, p≤0.001), baseline visual impairment (15.6% vs 5.5%, p≤0.001), diabetes (12.0% vs 7.42%, p≤0.05) and higher baseline depression scores (9.7 vs 8.4 on a scale of 0-30, p≤0.05). In linear regression models, older age, worse distance vision, hypertension or diabetes, illiteracy and lower depression score were significantly associated with undergoing surgery. Results were similar in models including only persons aged ≥60 years, except that urban residence was also associated with surgery. When only those aged ≥60 years with poor vision were included, results were again the same, except that higher household expenditure was also associated with surgery. CONCLUSIONS: In China, cataract surgical rates remain low; underserved groups such as rural dwellers are less likely to receive cataract surgery.


Asunto(s)
Extracción de Catarata , Catarata , Baja Visión , Humanos , Estudios Longitudinales , Agudeza Visual , Catarata/epidemiología , China/epidemiología
14.
Langmuir ; 39(19): 6657-6665, 2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37126661

RESUMEN

Micro- and nanotexturing on hard biomaterials have shown advantages for tissue engineering and antifouling applications. However, a growing number of studies have also shown that texturing may cause an increase in friction, demanding further research on the tribological effects of texturing under physiological conditions. This study investigates the tribological effects of micro- and nanopore patterns on hard hydrophilic silicon sliding against soft hydrophobic polydimethylsiloxane (PDMS) immersed in aqueous liquids with various viscosities, simulating the sliding of a textured implant surface against soft tissues. The experimental results show that silicon surfaces with pore textures at both micro- and nanoscale feature sizes confer a higher coefficient of friction (COF) than an untextured one. It is attributed to the texture's edge effect caused by the periodic pore patterns between the two sliding objects with a large difference in material stiffness. For the same solid area fraction, nanopored surfaces show a higher COF than micropored surfaces because of the significantly higher texture edge length per unit area. For micropored surfaces with a similar length of texture edge length per unit area, the COF increases more significantly with the increase in pore size because of the greater stress at the rims of the larger pores. The COFs of both micro- and nanoscale pores generally decrease from ∼10 to 0.1 with an increase in the surrounding aqueous viscosity, indicating the transition from a boundary lubrication to a mixed lubrication regime while mostly remaining in boundary lubrication. In contrast, the COF of an untextured surface decreases from ∼1 to 0.01, indicating that it mostly remains in the mixed lubrication regime while showing the tendency toward hydrodynamic lubrication. Compared to a hydrophilic hard probe sliding against a textured hydrophobic soft substrate, the hydrophobic soft probe sliding against a textured hydrophilic hard substrate produces a significantly higher COF under similar physiological conditions due to the larger edge effect.

15.
Int J Bioprint ; 9(2): 656, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37065672

RESUMEN

The printing accuracy of polymer melt electrowriting is adversely affected by the residual charge entrapped within the fibers, especially for three-dimensional (3D) structured materials or multilayered scaffolds with small interfiber distances. To clarify this effect, an analytical charge-based model is proposed herein. The electric potential energy of the jet segment is calculated considering the amount and distribution of the residual charge in the jet segment and the deposited fibers. As the jet deposition proceeds, the energy surface assumes different patterns, which constitute different modes of evolution. The manner in which the various identified parameters affect the mode of evolution are represented by three charge effects, including the global, local, and polarization effect. Based on these representations, typical modes of energy surface evolution are identified. Moreover, the lateral characteristic curve and characteristic surface are advanced to analyze the complex interplay between fiber morphologies and residual charge. Different parameters contribute to this interplay either by affecting residual charge, fiber morphologies, or the three charge effects. To validate this model, the effects of lateral location and grid number (i.e., number of fibers printed in each direction) on the fiber morphologies are investigated. Moreover, the "fiber bridging" phenomenon in parallel fiber printing is successfully explained. These results help to comprehensively understand the complex interplay between the fiber morphologies and the residual charge, thus furnishing a systematic workflow to improve printing accuracy.

16.
J Vasc Surg ; 78(2): 333-343.e4, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37037259

RESUMEN

OBJECTIVE: To evaluate the risk for 90-day returns to care and long-term subsequent surgical interventions after primary endovascular aneurysm repair (EVAR) with an Endologix AFX Endovascular AAA System compared with three other high-volume endograft devices. METHODS: We conducted a matched cohort study using data from Kaiser Permanente's Endovascular Stent Graft Registry. Patients aged ≥18 years who underwent primary EVAR for AAA in the health care system from January 1, 2011, to December 31, 2017, comprised the eligible study sample. The treatment group included patients who received an Endologix AFX or AFX2 device (n = 470). Patients who received one of three other high-volume endograft devices used within the health care system comprised the eligible comparison group (n = 2122). These patients were 2:1 propensity score matched without replacement to patients who received an Endologix device based on a number of patient and procedural characteristics. After the application of matching, conditional logistic regression was used to evaluate the likelihood for 90-day emergency department visit and readmission. Cause-specific Cox regression was used to evaluate the long-term risk of endoleak, graft revision, secondary reintervention (not including revision), conversion to open repair, and rupture during follow-up. Cox proportional hazards regression was used to evaluate the risk of mortality (overall and aneurysm related). RESULTS: The final matched study sample included 470 patients who received an Endologix AFX or AFX2 device and 940 patients who received a different high-volume device. compared with the other devices, AFX/AFX2 had a higher risk for type III endoleak (hazard ratio [HR], 38.79; 95% confidence interval [CI], 14.51-103.67), revision surgery >1 year after the primary EVAR (HR, 4.50; 95% CI, 3.10-6.54), rupture (HR, 6.52; 95% CI, 1.73-24.63), and aneurysm-related mortality (HR, 2.43; 95% CI, 1.32-4.47) was observed with the use of AFX/AFX2. CONCLUSIONS: In our matched cohort study, patients who received an Endologix AFX System during their primary EVAR had a higher risk for several adverse longitudinal outcomes, as well as aneurysm-related mortality, when compared with patients who received other high-volume devices. Patients who have received these devices should be monitored closely after EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Adolescente , Adulto , Prótesis Vascular , Endofuga/etiología , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Estudios de Cohortes , Resultado del Tratamiento , Factores de Riesgo , Estudios Retrospectivos , Stents
18.
Front Med (Lausanne) ; 10: 1115032, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36936225

RESUMEN

Purpose: The aim of this study was to prospectively quantify the level of agreement among the deep learning system, non-physician graders, and general ophthalmologists with different levels of clinical experience in detecting referable diabetic retinopathy, age-related macular degeneration, and glaucomatous optic neuropathy. Methods: Deep learning systems for diabetic retinopathy, age-related macular degeneration, and glaucomatous optic neuropathy classification, with accuracy proven through internal and external validation, were established using 210,473 fundus photographs. Five trained non-physician graders and 47 general ophthalmologists from China were chosen randomly and included in the analysis. A test set of 300 fundus photographs were randomly identified from an independent dataset of 42,388 gradable images. The grading outcomes of five retinal and five glaucoma specialists were used as the reference standard that was considered achieved when ≥50% of gradings were consistent among the included specialists. The area under receiver operator characteristic curve of different groups in relation to the reference standard was used to compare agreement for referable diabetic retinopathy, age-related macular degeneration, and glaucomatous optic neuropathy. Results: The test set included 45 images (15.0%) with referable diabetic retinopathy, 46 (15.3%) with age-related macular degeneration, 46 (15.3%) with glaucomatous optic neuropathy, and 163 (55.4%) without these diseases. The area under receiver operator characteristic curve for non-physician graders, ophthalmologists with 3-5 years of clinical practice, ophthalmologists with 5-10 years of clinical practice, ophthalmologists with >10 years of clinical practice, and the deep learning system for referable diabetic retinopathy were 0.984, 0.964, 0.965, 0.954, and 0.990 (p = 0.415), respectively. The results for referable age-related macular degeneration were 0.912, 0.933, 0.946, 0.958, and 0.945, respectively, (p = 0.145), and 0.675, 0.862, 0.894, 0.976, and 0.994 for referable glaucomatous optic neuropathy, respectively (p < 0.001). Conclusion: The findings of this study suggest that the accuracy of this deep learning system is comparable to that of trained non-physician graders and general ophthalmologists for referable diabetic retinopathy and age-related macular degeneration, but the deep learning system performance is better than that of trained non-physician graders for the detection of referable glaucomatous optic neuropathy.

19.
Biomolecules ; 13(3)2023 03 20.
Artículo en Inglés | MEDLINE | ID: mdl-36979497

RESUMEN

The rising global prevalence of myopia is a growing concern for clinicians, as it predisposes patients to severe ocular pathologies including glaucoma. High myopia can be associated with clinical features that resemble glaucomatous damage, which make an accurate glaucoma diagnosis challenging, particularly among patients with normal intraocular pressures. These patients may also present with established visual field defects which can mimic glaucoma, and standard imaging technology is less useful in disease detection and monitoring due to the lack of normative data for these anatomically unique eyes. Progression over time remains the most critical factor in facilitating the detection of early glaucomatous changes, and thus careful longitudinal follow-up of high-risk myopic patients is the most important aspect of management. Here, we review our current understanding of the complex relationship between myopia and glaucoma, and the diagnostic challenges and limitations of current testing protocols including visual field, intraocular pressure, and imaging. Furthermore, we discuss the clinical findings of two highly myopic patients with suspected glaucoma.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Miopía , Humanos , Glaucoma de Ángulo Abierto/complicaciones , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/patología , Glaucoma/diagnóstico , Presión Intraocular , Pruebas del Campo Visual , Miopía/diagnóstico
20.
Adv Mater ; 35(19): e2207927, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36906738

RESUMEN

An unconventional "heteromorphic" superlattice (HSL) is realized, comprised of repeated layers of different materials with differing morphologies: semiconducting pc-In2 O3 layers interleaved with insulating a-MoO3 layers. Originally proposed by Tsu in 1989, yet never fully realized, the high quality of the HSL heterostructure demonstrated here validates the intuition of Tsu, whereby the flexibility of the bond angle in the amorphous phase and the passivation effect of the oxide at interfacial bonds serve to create smooth, high-mobility interfaces. The alternating amorphous layers prevent strain accumulation in the polycrystalline layers while suppressing defect propagation across the HSL. For the HSL with 7:7 nm layer thickness, the observed electron mobility of 71 cm2  Vs-1 , matches that of the highest quality In2 O3 thin films. The atomic structure and electronic properties of crystalline In2 O3 /amorphous MoO3 interfaces are verified using ab-initio molecular dynamics simulations and hybrid functional calculations. This work generalizes the superlattice concept to an entirely new paradigm of morphological combinations.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...