1.
Phys Med Biol ; 59(12): 3019-40, 2014 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-24842293

RESUMEN

In carbon ion beams, biological effects vary along the ion track; hence, to quantify them, specific radiobiological models are needed. One of them, the local effect model (LEM), in particular version I (LEM I), is implemented in treatment planning systems (TPS) clinically used in European particle therapy centers. From the physical properties of the specific ion radiation, the LEM calculates the survival probabilities of the cell or tissue type under study, provided that some determinant input parameters are initially defined. Mathematical models can be used to predict, for instance, the tumor control probability (TCP), and then evaluate treatment outcomes. This work studies the influence of the LEM I input parameters on the TCP predictions in the specific case of prostate cancer. Several published input parameters and their combinations were tested. Their influence on the dose distributions calculated for a water phantom and for a patient geometry was evaluated using the TPS TRiP98. Changing input parameters induced clinically significant modifications of the mean dose (up to a factor of 3.5), spatial dose distribution, and TCP predictions (up to factor of 2.6 for D50). TCP predictions were found to be more sensitive to the parameter threshold dose (Dt) than to the biological parameters α and ß. Additionally, an analytical expression was derived for correlating α, ß and Dt, and this has emphasized the importance of [Formula: see text]. The improvement of radiobiological models for particle TPS will only be achieved when more patient outcome data with well-defined patient groups, fractionation schemes and well-defined end-points are available.


Asunto(s)
Modelos Biológicos , Neoplasias de la Próstata/radioterapia , Dosis de Radiación , Humanos , Masculino , Probabilidad , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
2.
Phys Med Biol ; 58(12): 3979-93, 2013 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-23685746

RESUMEN

Scanned ion beam delivery enables the highest degree of target dose conformation attainable in external beam radiotherapy. Nominal pencil beam widths (spot sizes) are recorded during treatment planning system commissioning. Due to changes in the beam-line optics, the actual spot sizes may differ from these commissioning values, leading to differences between planned and delivered dose. The purpose of this study was to analyse the dosimetric consequences of spot size variations in particle therapy treatment plans. For 12 patients with skull base tumours and 12 patients with prostate carcinoma, scanned-beam carbon ion and proton treatment plans were prepared and recomputed simulating spot size changes of (1) ±10% to simulate the typical magnitude of fluctuations, (2) ±25% representing the worst-case scenario and (3) ±50% as a part of a risk analysis in case of fault conditions. The primary effect of the spot size variation was a dose deterioration affecting the target edge: loss of target coverage and broadening of the lateral penumbra (increased spot size) or overdosage and contraction of the lateral penumbra (reduced spot size). For changes ≤25%, the resulting planning target volume mean 95%-isodose line coverage (CI-95%) deterioration was ranging from negligible to moderate. In some cases changes in the dose to adjoining critical structures were observed.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Asistida por Computador/métodos , Humanos , Masculino , Neoplasias de la Próstata/radioterapia , Radiometría , Neoplasias de la Base del Cráneo/radioterapia