Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 115(2): 027002, 2015 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-26207496

RESUMEN

The spin character of the states at the top of the valence band in doped La(2-x)Sr(x)CuO(4) (x=0.03, 0.07, 0.15, 0.22, and 0.30) has been investigated using spin-polarized resonant photoemission. A clear Zhang-Rice singlet (ZRS) is observed at all doping levels. Its stability and polarization are preserved as a function of doping, suggesting that the concept of the ZRS can be used across a wide doping range and up to the metallic nonsuperconducting overdoped regime. The results are significant for theoretical models that use the ZRS approximation and for the understanding of the peculiar interplay between the ZRS and the remaining localized spins.

2.
Phys Med ; 24(2): 92-7, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18407772

RESUMEN

Synchrotron stereotactic radiotherapy (SSR) is a treatment that involves selective accumulation of high-Z elements in tumours followed by stereotactic irradiation, in CT mode, with monochromatic X-rays from a synchrotron source, tuned at an optimal energy. The irradiation geometry, characteristic X-rays, photoelectrons, and Auger electrons generated on high-Z atoms by kilovoltage X-rays produce a localized dose enhancement. Two complimentary SSR approaches have been successfully developed in the past 5 years in our team, and may be promising in high-grade glioma management: iodine-enhanced SSR, with an iodinated contrast agent; and Pt-enhanced SSR; a concomitant radio-chemotherapy treatment with locoregional injection of platinated chemotherapy drugs. The results for iodine-enhanced SSR using contrast agents are presented in this paper. IUdR-enhanced SSR was also tested in this study. Up to 15 Gy, intracarotid infusion of iodine significantly improved the rats' survival compared to irradiation alone. SSR provides the most protracted survivals of F98 glioma-bearing rats. The technique is currently transferred to clinical trials. Iodine-enhanced SSR will be implemented first, because of its simplicity; and pave the way for Pt-enhanced SSR, the most efficient technique, but still needing to be improved in terms of intrinsic toxicity.


Asunto(s)
Neoplasias Encefálicas/cirugía , Radiocirugia/métodos , Animales , Fenómenos Biofísicos , Biofisica , Medios de Contraste/administración & dosificación , Glioma/cirugía , Humanos , Idoxuridina/administración & dosificación , Yodo/administración & dosificación , Platino (Metal)/administración & dosificación , Ratas , Ratas Endogámicas F344 , Sincrotrones
3.
Br J Cancer ; 91(3): 544-51, 2004 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-15266326

RESUMEN

This study was designed to experimentally evaluate the optimal X-ray energy for increasing the radiation energy absorbed in tumours loaded with iodinated compounds, using the photoelectric effect. SQ20B human cells were irradiated with synchrotron monochromatic beam tuned at 32.8, 33.5, 50 and 70 keV. Two cell treatments were compared to the control: cells suspended in 10 mg ml(-1) of iodine radiological contrast agent or cells pre-exposed with 10 microM of iodo-desoxyuridine (IUdR) for 48 h. Our radiobiological end point was clonogenic cell survival. Cells irradiated with both iodine compounds exhibited a radiation sensitisation enhancement. Moreover, it was energy dependent, with a maximum at 50 keV. At this energy, the sensitisation calculated at 10% survival was equal to 2.03 for cells suspended in iodinated contrast agent and 2.60 for IUdR. Cells pretreated with IUdR had higher sensitisation factors over the energy range than for those suspended in iodine contrast agent. Also, their survival curves presented no shoulder, suggesting complex lethal damages from Auger electrons. Our results confirm the existence of the 50 keV energy optimum for a binary therapeutic irradiation based on the presence of stable iodine in tumours and an external irradiation. Monochromatic synchrotron radiotherapy concept is hence proposed for increasing the differential effect between healthy and cancerous tissue irradiation.


Asunto(s)
Carcinoma de Células Escamosas/patología , Neoplasias de Cabeza y Cuello/patología , Idoxuridina/farmacología , Yodo/farmacocinética , Inhibidores de la Síntesis del Ácido Nucleico/farmacología , Fármacos Sensibilizantes a Radiaciones/farmacología , Terapia por Rayos X/métodos , Muerte Celular , Supervivencia Celular , Medios de Contraste/farmacocinética , Humanos , Idoxuridina/farmacocinética , Yodo/farmacología , Inhibidores de la Síntesis del Ácido Nucleico/farmacocinética , Tolerancia a Radiación , Fármacos Sensibilizantes a Radiaciones/farmacocinética , Células Tumorales Cultivadas
4.
Radiat Res ; 158(6): 763-70, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12452779

RESUMEN

In this paper we describe the results of experiments using synchrotron radiation to trigger the Auger effect in living human cancer cells treated with a widely used chemotherapy drug: cis-diamminedichloroplatinum (II) (cisplatin). The experiments were carried out at the ID17 beamline of the European Synchrotron Radiation Facility, which produces a high-fluence monochromatic beam that is adjustable from 20 to 80 keV. Cisplatin was chosen as the carrier of platinum atoms in the cells because of its alkylating-like activity and the irradiation was done with monochromatic beams above and below the platinum K-shell edge (78.39 keV). Cell survival curves were comparable with those obtained for the same cells under conventional irradiation conditions. At a low dose of cisplatin (0.1 microM, 48 h), no difference was seen in survival when the cells were irradiated above and below the K-shell edge of platinum. Higher cisplatin concentrations were investigated to enhance the cellular platinum content. The results with 1 microM cisplatin for 12 h showed no difference when the cells were irradiated with beams above or below the platinum K-shell edge with the exception of the higher cell death resulting from drug toxicity. The intracellular content of platinum was significant, as measured macroscopically by inductively coupled plasma mass spectrometry. Its subcellular localization and particularly its presence in the cell nucleus were verified by microscopic synchrotron X-ray fluorescence. This was the first known attempt at K-shell edge photon activation of stable platinum in living cells with a platinum complex used for chemotherapy. Its evident toxicity in these cells leads us to put forth the hypothesis that cisplatin toxicity can mask the enhancement of cell death induced by the irradiation above the K-shell edge. However, K-shell edge photon activation of stable elements provides a powerful technique for the understanding of the biological effects of Auger processes. Further avenues of development are discussed.


Asunto(s)
Muerte Celular , Supervivencia Celular/efectos de los fármacos , Supervivencia Celular/efectos de la radiación , Cisplatino/farmacología , Aceleradores de Partículas/instrumentación , Platino (Metal)/farmacología , Fármacos Sensibilizantes a Radiaciones/farmacología , Rayos X , Calibración , Ciclo Celular , Línea Celular , Ensayo de Unidades Formadoras de Colonias , Relación Dosis-Respuesta en la Radiación , Citometría de Flujo , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Fotones , Células Tumorales Cultivadas
5.
Phys Med Biol ; 47(18): 3369-85, 2002 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-12375826

RESUMEN

We investigated the performance of monochromatic computed tomography for the quantification of contrast agent concentrations. Two subtraction methods (K-edge subtraction and temporal subtraction) were evaluated and compared theoretically and experimentally in terms of detection limit, precision and accuracy. Measurements were performed using synchrotron x-rays with Lucite phantoms (10 cm and 17.5 cm in diameter) containing iodine or gadolinium solutions ranging from 50 microg ml(-1) to 5 mg ml(-1). The experiments were carried out using monochromators developed at the European Synchrotron Radiation Facility (ESRF) medical beamline. The phantoms were imaged either above and below the contrast agent K-edge, or before and after the addition of the contrast agent. Both methods gave comparable performance for phantoms less than 10 cm in diameter. For large phantoms, equivalent to a human head, the temporal subtraction is more suitable for detecting elements such as iodine, keeping a reasonable x-ray dose delivered to the phantom. A good agreement was obtained between analytical calculations, simulations and measurements. The beam harmonic content was taken into account in the simulations. It explains the performance degradation with high contrast agent concentrations. The temporal subtraction technique has the advantage of energy tunability and is well suited for imaging elements, such as iodine or gadolinium, in highly absorbing samples. For technical reasons, the K-edge method is preferable when the imaged organ is moving since the two measurements can be performed simultaneously, which is mandatory for obtaining a good subtraction.


Asunto(s)
Medios de Contraste/farmacología , Tomografía Computarizada por Rayos X/métodos , Rayos X , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/metabolismo , Relación Dosis-Respuesta a Droga , Gadolinio/farmacología , Humanos , Yodo/farmacología , Distribución Normal , Fantasmas de Imagen , Fotones , Radiometría , Factores de Tiempo
7.
Phys Med Biol ; 45(9): L39-43, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11008947

RESUMEN

The first operation of the European Synchrotron Radiation Facility (ESRF) medical beamline is reported in this paper. The goal of the angiography project is to develop a reduced risk imaging technique, which can be used to follow up patients after coronary intervention. After the intravenous injection of a contrast agent (iodine) two images are produced with monochromatic beams, bracketing the iodine K-edge. The logarithmic subtraction of the two measurements results in an iodine enhanced image, which can be precisely quantified. A research protocol has been designed to evaluate the performances of this method in comparison with the conventional technique. Patients included in the protocol have previously undergone angioplasty. If a re-stenosis is suspected, the patient is imaged both at the ESRF and at the hospital with the conventional technique, within the next few days. This paper reports the results obtained with the first patients. To date, eight patients have been imaged and excellent image quality was obtained.


Asunto(s)
Angiografía Coronaria/instrumentación , Angiografía Coronaria/métodos , Sincrotrones , Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/métodos , Europa (Continente) , Francia , Humanos
8.
Cell Mol Biol (Noisy-le-grand) ; 46(6): 1053-63, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10976863

RESUMEN

The application of synchrotron radiation in medical research has become a mature field of research at synchrotron facilities worldwide. In the relatively short time that synchrotrons have been available to the scientific community, their characteristic beams of UV and X-ray radiation have been applied to virtually all areas of medical science which use ionizing radiation. The ability to tune intense monochromatic beams over wide energy ranges differentiates these sources from standard clinical and research tools. At the European Synchrotron Radiation Facility (Grenoble, France), a major research facility is operational on an advanced wiggler radiation beamport, ID17. The beamport is designed to carry out a broad range of research ranging from cell radiation biology to in vivo human studies. Medical imaging programs at ID17 include transvenous coronary angiography, computed tomography, mammography and bronchography. In addition, a major research program on microbeam radiation therapy is progressing. This paper will present a very brief overview of the beamline and the imaging and therapy programs.


Asunto(s)
Sincrotrones/instrumentación , Animales , Angiografía Coronaria/instrumentación , Europa (Continente) , Humanos , Radioterapia de Alta Energía/instrumentación , Investigación , Tomografía Computarizada por Rayos X/instrumentación , Difracción de Rayos X/instrumentación
9.
Cell Mol Biol (Noisy-le-grand) ; 46(6): 1065-75, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10976864

RESUMEN

We present in this paper two imaging techniques using contrast agents assessed with in vivo experiments. Both methods are based on the same physical principle, and were implemented at the European Synchrotron Radiation Facility medical beamline. The first one is intravenous coronary angiography using synchrotron radiation X-rays. This imaging technique has been planned for human studies in the near future. We describe the first experiments that were carried out with pigs at the ESRF. The second imaging mode is computed tomography using synchrotron radiation on rats bearing brain tumors. Owing to synchrotron radiation physical properties, these new imaging methods provide additional information compared to conventional techniques. After infusion of the contrast agent, it is possible to derive from the images the concentration of the contrast agent in the tumor area for the computed tomography and in any visible vessel for the angiography method.


Asunto(s)
Angiografía Coronaria/métodos , Sincrotrones , Tomografía Computarizada por Rayos X/métodos , Animales , Neoplasias Encefálicas/diagnóstico por imagen , Medios de Contraste , Angiografía Coronaria/instrumentación , Europa (Continente) , Gadolinio , Glioma/diagnóstico por imagen , Humanos , Yodo , Ratas , Porcinos , Sincrotrones/instrumentación , Tomografía Computarizada por Rayos X/instrumentación
10.
Eur Radiol ; 10(9): 1487-92, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10997441

RESUMEN

The purpose of this work was to demonstrate the feasibility of a new imaging technique called synchrotron radiation computed tomography (SRCT). This technique leads to a direct assessment of the in vivo concentration of an iodine- or gadolinium-labeled compound. Rats bearing C6 glioma were imaged by MRI prior to the SRCT experiment. The SRCT experiments were performed after a 1.3 g I/kg (n = 5) or a 0.4 g Gd/kg (n = 5) injection. Finally, brains were sampled for histology. The SRCT images exhibited contrast enhancement at the tumor location. Ten minutes after injection, iodine and gadolinium tissular concentrations were equal to 0.80 ( +/- 0.40) mg/cm3 and 0.50 ( +/- 0.10) mg/cm3, respectively in the peripheral area of the tumor (respective background value: 0.20 +/- 0.02 to 0.10 +/- 0.01). Correlation to MRI and histology revealed that the contrast uptake occurred in the most vascularized area of the tumor. The present study summarizes the feasibility of in vivo SRCT to obtain quantitative information about iodine and gadolinium-labeled compounds. Beyond brain tumor pathology, the SRCT appears as a complementary approach to MRI and CT, for studying iodine- and gadolinium-labeled compounds by the direct achievement of the tissular concentration value in the tissue.


Asunto(s)
Neoplasias Encefálicas/diagnóstico , Medios de Contraste , Gadolinio , Glioma/diagnóstico , Ácido Yoxáglico , Meglumina , Compuestos Organometálicos , Sincrotrones , Tomografía Computarizada por Rayos X , Animales , Estudios de Factibilidad , Femenino , Ratas , Ratas Wistar , Células Tumorales Cultivadas
11.
J Synchrotron Radiat ; 7(Pt 5): 340-7, 2000 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-16609218

RESUMEN

A fixed-exit monochromator has been constructed for computed tomography (CT) studies at the Medical Beamline of the European Synchrotron Radiation Facility. A non-dispersive pair of bent Laue-type crystals is used, and the first crystal is water-cooled. The monochromator operates at energies from 18 to 90 keV, and the maximum width of the beam is 150 mm. The performance of the monochromator is studied with respect to the beam intensity and energy distributions, and a close agreement is found between the calculated and experimental results. The intensity is between 10(9) and 10(10) photons s(-1) mm(-2) under typical operating conditions. The harmonic content of a 25 keV beam is about 30% at the minimum wiggler gap of 25 mm (field 1.57 T) and decreases by an order of magnitude when the gap is increased to 60 mm (field 0.62 T). The experimental set-up for CT studies includes dose monitors, goniometers and translation stages for positioning and scanning the object, and a 432-element linear-array Ge detector. Examples from phantom studies and in vivo animal experiments are shown to illustrate the spatial resolution and contrast of the reconstructed images.

12.
Acta Radiol Suppl ; 412: 29-41, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9240078

RESUMEN

Synchrotron sources can provide intense, collimated and tunable X-ray beams suitable for medical imaging and research, allowing the use of monochromatic X-rays for human examinations. At the European Synchrotron Radiation Facility (ESRF), a beam line dedicated to medical research is under commissioning. Two imaging programs are being developed, for coronary angiography and cerebral CT. The new monochromatic imaging systems should improve image contrast and provide better image quantification. The properties of synchrotron radiation are described, as well as the instrumentation of the medical beam line and its 2 imaging programs. The new possibilities offered by synchrotron radiation for contrast media research are discussed, the improvement on concentration measurement precision achievable is underlined.


Asunto(s)
Medios de Contraste , Sincrotrones , Academias e Institutos , Angiografía Coronaria/métodos , Angiografía Coronaria/estadística & datos numéricos , Europa (Continente) , Humanos , Fenómenos Físicos , Física , Sensibilidad y Especificidad , Sincrotrones/instrumentación , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos
13.
Bull Cancer ; 82 Suppl 5: 544s-548s, 1995 Dec.
Artículo en Francés | MEDLINE | ID: mdl-8680062

RESUMEN

Whether for diagnosis or therapeutic purposes, X-rays have many applications in medicine. Synchrotron Radiation sources open new perspectives. This has already been the case for a number of years in molecular and cellular biology where the scope of absorption and diffraction work has been greatly extended. This could also be the case for medical imaging and radiotherapy where the characteristics of the beam (collimation, stability, flux) allow new approaches in the energy range of radiological X-rays, namely between 30 keV and 100 keV. Such a source exists today in Grenoble, with the European Synchrotron Radiation Facility (ESRF). The opening of a beamline dedicated to medical research for whole European scientific community is planned for the end of 1996. This beamline, coupled with the "microbeam" beamlines, will cover medical imaging (angiography, tomodensitometry, microtomography, X-ray microscopy) as well as radiotherapy.


Asunto(s)
Diagnóstico por Imagen/métodos , Radioterapia de Alta Energía/métodos , Sincrotrones , Animales , Angiografía Coronaria/métodos , Cricetinae , Humanos , Ratas , Investigación , Tomografía Computarizada por Rayos X/métodos , Difracción de Rayos X/instrumentación , Difracción de Rayos X/métodos , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...