Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
PLoS One ; 19(6): e0304552, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38838028

RESUMEN

BACKGROUND: Vaginal rings formulated to deliver two drugs simultaneously have potential as user-controlled, long-acting methods for dual prevention of HIV and pregnancy. METHODS: Two phase 1 randomized trials (MTN-030/IPM 041 and MTN-044/IPM 053/CCN019) respectively enrolled 24 and 25 healthy, HIV-negative participants to evaluate safety, pharmacokinetics, and vaginal bleeding associated with use of a vaginal ring containing 200mg dapivirine (DPV) and 320mg levonorgestrel (LNG) designed for 90-day use. MTN-030/IPM 041 compared the DPV/LNG ring to a DPV-only ring (200mg) over 14 days of use. MTN-044/IPM 053/CCN019 compared continuous or cyclic use of the DPV/LNG ring over 90 days of use. Safety was assessed by recording adverse events (AEs). DPV and LNG concentrations were quantified in plasma, cervicovaginal fluid, and cervical tissue. Vaginal bleeding was self-reported. RESULTS: There were no differences in the proportion of participants with grade ≥2 genitourinary AEs or grade ≥3 AEs with DPV/LNG ring vs. DPV ring use (p = .22), or with DPV/LNG ring continuous vs. cyclic use (p = .67). Higher plasma DPV concentrations were observed in users of DPV/LNG compared to DPV-only rings (Cmax p = 0.049; AUC p = 0.091). Plasma DPV and LNG concentrations were comparable with continuous and cyclic use (Cmax p = 0.74; AUC p = 0.25). With cyclic use, median nadir plasma DPV concentration was approximately 300 pg/mL two days after removal and median t1/2 for cervicovaginal fluid DPV concentration was 5.76 hours (n = 3). Overall bleeding experiences did not differ between continuous and cyclic users (p = 0.12). CONCLUSIONS: The extended duration DPV/ LNG rings were well tolerated and the observed DPV concentrations in plasma and cervicovaginal fluid when used continuously exceeded concentrations observed in previous DPV ring efficacy studies. LNG concentrations in plasma were comparable with other efficacious LNG-based contraceptives. Genital DPV concentrations had a short half-life and were thus not well sustained following ring removal.


Asunto(s)
Dispositivos Anticonceptivos Femeninos , Levonorgestrel , Pirimidinas , Hemorragia Uterina , Humanos , Femenino , Levonorgestrel/farmacocinética , Levonorgestrel/administración & dosificación , Levonorgestrel/efectos adversos , Adulto , Pirimidinas/farmacocinética , Pirimidinas/efectos adversos , Pirimidinas/administración & dosificación , Dispositivos Anticonceptivos Femeninos/efectos adversos , Fármacos Anti-VIH/farmacocinética , Fármacos Anti-VIH/efectos adversos , Fármacos Anti-VIH/administración & dosificación , Adulto Joven , Persona de Mediana Edad , Infecciones por VIH/tratamiento farmacológico
2.
J Int AIDS Soc ; 27(3): e26223, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38444118

RESUMEN

INTRODUCTION: Tenofovir-based oral pre-exposure prophylaxis is currently approved for HIV prevention; however, adherence in women has been low. A vaginal gel containing tenofovir (TFV) demonstrated partial protection to HIV but protection was not confirmed in additional studies. Vaginal rings offer user-controlled long-acting HIV prevention that could overcome adherence and protection challenges. TFV may also help prevent herpes simplex virus type 2 acquisition when delivered intravaginally. We evaluated the pharmacokinetics, safety, adherence and acceptability of a 90-day TFV ring. METHODS: Between January and June 2019, Microbicide Trials Network (MTN)-038 enrolled 49 HIV-negative participants into a phase 1, randomized (2:1) trial comparing a 90-day ring containing 1.4 grams (g) TFV to a placebo ring. TFV concentrations were quantified in plasma, cervicovaginal fluid (CVF), rectal fluid and cervical tissue, and TFV-diphosphate (TFV-DP) in cervical tissue. Used rings were analysed for residual TFV. Safety was assessed by adverse events (AEs); acceptability and adherence by self-report. RESULTS: Mean age was 29.5; 46 identified as cisgender-female and three gender non-conforming. There were no differences in the proportion of participants with grade ≥2 genitourinary AEs in the TFV versus placebo arms (p = 0.41); no grade ≥3 AEs were reported. Geometric mean TFV concentrations increased through day 34 in CVF/rectal fluid and day 59 in plasma, but declined across compartments by day 91. Geometric mean TFV-DP tissue concentrations exceeded the 1000 fmol/mg target through day 56, but fell to 456 fmol/mg at day 91. Among 32 rings returned at the end of the study, 13 had no or low (<0.1 g) residual TFV. Residual TFV did not differ by socio-demographics, sexual activity, Nugent Score or vaginal microbiota. Most participants reported being fully adherent to ring use: 85% and 81% in the TFV and placebo arms, respectively (p = 1.00). A majority of participants reported liking the ring (median 8 on a 10-point Likert scale) and reported a high likelihood of using the ring in the future, if effective (median 9). CONCLUSIONS: The 90-day TFV ring was well-tolerated, acceptable and exceeded target cervical tissue concentrations through day 56, but declined thereafter. Additional studies are needed to characterize the higher release from TFV rings in some participants and the optimal duration of use.


Asunto(s)
Infecciones por VIH , Tenofovir , Adulto , Femenino , Humanos , Adenina , Herpesvirus Humano 2 , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/prevención & control , Microbiota , Tenofovir/efectos adversos , Tenofovir/farmacocinética , Estados Unidos
3.
Front Reprod Health ; 5: 1147628, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37484873

RESUMEN

Introduction: With high concurrent global rates of HIV incidence and unintended pregnancy, there is a need to provide options beyond condoms to enable users to simultaneously prevent HIV acquisition and pregnancy. Multiple vaginal rings are in development as "MPTs" (multipurpose prevention technologies) as they are shown to provide several co-occurring benefits such as discretion, convenience, reversibility and user control. Methods: In this Phase 1 trial of a 3-month MPT ring in the U.S., 25 participants (low-risk for HIV and pregnancy) were randomized to use the study ring for 90 days continuously or in 28-day cycles with 2-day removal periods in between. All participants completed in-depth interviews at the end of their study participation. Results: Overall, the ring was well tolerated. Participants resoundingly endorsed the concept of an extended-use, dual-purpose vaginal ring, but reported too many functional challenges and side effects to endorse this particular ring. Participants assigned to the continuous regimen reported more positive experiences with ring use than those in the cyclic group. A minority of participants who experienced minimal side effects and did not experience challenges with vaginal retention of the ring found it appealing. However, the majority of participants experienced challenges (ring slippage, expulsions, side effects, vaginal bleeding changes) with product use that outweighed the potential benefits and led them to report that - in the future - they would not be interested in using this specific version of the ring in its current form. A subset expressed interest in using the current MPT ring under certain conditions (e.g., if fewer expulsions, less bleeding, higher risk for HIV/pregnancy). Discussion: User feedback regarding participant experiences and challenges with the study ring was continuously shared with the product developer, underscoring the value of early-stage end-user feedback in product development.

5.
Obstet Gynecol ; 141(5): 1004-1006, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-37023451

RESUMEN

FUNDING SOURCE: Medicines360. The Sponsor, Medicines360, designed the study and oversaw its conduct, including funding the trial and providing all study product free of charge to participants. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT00995150.


Asunto(s)
Anticonceptivos Femeninos , Dispositivos Intrauterinos Medicados , Dispositivos Intrauterinos , Femenino , Humanos , Anticonceptivos Femeninos/efectos adversos , Dispositivos Intrauterinos Medicados/efectos adversos , Levonorgestrel/efectos adversos , Factores de Tiempo
6.
Contraception ; 117: 30-35, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36084711

RESUMEN

OBJECTIVES: Crisis pregnancy centers (CPCs) seek to dissuade people from having abortions. Twenty-five states have policies supporting CPCs. We aimed: (1) to characterize access to early pregnancy confirmation at CPCs compared to abortion facilities nationwide and (2) to understand the role of state CPC policy in service access. STUDY DESIGN: We conducted a national mystery caller study of 445 CPCs and geographically paired abortion facilities, posing as patients seeking pregnancy confirmation. Facility type (CPC vs abortion facility) was the primary exposure in Aim 1. Wait time to first available early pregnancy appointment was the primary outcome. In Aim 2, state-level CPC policy designation (supportive vs not supportive of CPCs) was the primary exposure. Difference in wait time ≥7 days to first available appointment between CPCs and paired abortion facilities was the primary outcome. RESULTS: CPCs were more likely than abortion facilities to provide same-day appointments (68.5% vs 37.2%, p < 0.0001), and free pregnancy testing (98.0% vs 16.6%, p < 0.0001). The median wait to first available appointment at a CPC was 0 days (IQR 0,1), compared to 1 day at abortion facilities (IQR 0, 5), p < 0.0001. In states with supportive CPC policy environments, abortion facilities were less likely to have wait times exceeding their paired CPC by a week or more, compared to paired facilities in states with non-supportive CPC policy environments (p = 0.033). This remained true after adjusting for state abortion policy environment (p = 0.011). CONCLUSIONS: Pregnancy confirmation is more accessible at CPCs compared to abortion facilities. Factors other than state-level CPC policies likely influence service accessibility. There is a need for improved access to pregnancy confirmation in medical settings. IMPLICATIONS: Our findings demonstrating that pregnancy confirmation is more accessible at crisis pregnancy centers than at abortion facilities are predicted to be exacerbated in the wake of abortion clinic closures following the Dobbs v Jackson Women's Health Organization Supreme Court decision. This highlights the need for improved funding and support for pregnancy confirmation service delivery in medical settings, including abortion facilities.


Asunto(s)
Aborto Inducido , Embarazo , Estados Unidos , Femenino , Humanos , Instituciones de Atención Ambulatoria , Citas y Horarios , Accesibilidad a los Servicios de Salud
7.
Contraception ; 118: 109908, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36332661

RESUMEN

OBJECTIVES: To evaluate efficacy and satisfaction of dextromethorphan as a non-narcotic adjuvant to current analgesic regimens for medication abortion. STUDY DESIGN: We conducted a randomized, double-blinded, placebo-controlled trial. We randomized eligible participants (N = 156) 1:1 to adjunctively take dextromethorphan (loading dose 60 mg and two subsequent 30 mg doses at 2 and 5 hours after misoprostol administration) or placebo combined with usual-care nonsteroidal anti-inflammatory medications ± opioids for pain. Participants reported pain scores and satisfaction using a secure texting application at 2, 5, 8, and 24 hours after misoprostol administration. Our primary outcome was worst pain score and total analgesic use. RESULTS: Baseline demographics of enrolled participants were similar between randomization arms. Worst pain scores for participants receiving dextromethorphan versus placebo (8.0 vs 7.0, p = 0.06) did not differ. Total milligram usage of ibuprofen (800 mg vs 610 mg, p =.62), acetaminophen (1000 mg vs 1300 mg, p = 0.62), and opioids (10 mg vs 15 mg, p = 0.51) did not differ between the randomization groups. Participants randomized to placebo were significantly more likely to be satisfied with their pain control (91% vs 75%, p = 0.02). CONCLUSION: Dextromethorphan used adjunctively with standard analgesics did not reduce pain associated with medication abortion. Participants who received dextromethorphan reported decreased satisfaction with their pain control. IMPLICATIONS: Dextromethorphan used adjunctively with commonly used analgesic regimens did not reduce medication abortion associated pain. Many participants did not use analgesics as counseled, and nearly 25% used no analgesia during medication abortion.


Asunto(s)
Analgésicos no Narcóticos , Misoprostol , Embarazo , Femenino , Humanos , Dextrometorfano/uso terapéutico , Misoprostol/uso terapéutico , Método Doble Ciego , Analgésicos/uso terapéutico , Dolor/tratamiento farmacológico , Analgésicos Opioides/uso terapéutico , Dolor Postoperatorio/tratamiento farmacológico , Analgésicos no Narcóticos/uso terapéutico
8.
Eur J Contracept Reprod Health Care ; 27(6): 478-485, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36062524

RESUMEN

OBJECTIVE: To evaluate the effects of increased access to immediate postpartum contraceptive implants (IPI) on repeat pregnancy and contraceptive use rates among patients with opioid use disorder (OUD). MATERIALS AND METHODS: Between 2016 and 2018, 194 postpartum patients with OUD were offered the option of IPI placement at an institution with limited immediate postpartum long-acting reversible contraception availability and followed for one-year postpartum. Differences in pregnancy rates between participants who did and did not choose IPI were examined using logistic regression with inverse probability of treatment weighting from propensity scores accounting for differences between the two groups. RESULTS: Among 194 participants, 96 (49.5%) chose an IPI and 98 (50.5%) chose an alternative method or no contraception (non-IPI). Among IPI participants, 76 (80.9%) continued to use their implant at one-year postpartum. Overall, 19 participants had a repeat pregnancy and 11 (57.9%) were unintended. In multivariable analyses, repeat pregnancy was more likely among those who did not choose IPI (OR 9.90; 95% CI 3.58-27.03) than those who did. Participants with OUD and who used alcohol (11.66; 1.38, 98.20) or cocaine (2.72; 1.23, 5.99) during pregnancy were more likely to choose IPI. Participants who were married (0.28; 0.09, 0.89), engaged in OUD treatment prior to pregnancy (0.48; 0.25, 0.93), and happier when they found out about their pregnancy (0.87; 0.77, 0.98) were less likely to choose IPI. CONCLUSION: Offering patients with OUD the option of IPI is associated with high utilisation and continuation rates, and low rates of repeat pregnancy within one-year postpartum.


Asunto(s)
Anticoncepción Reversible de Larga Duración , Trastornos Relacionados con Opioides , Femenino , Embarazo , Humanos , Estudios Prospectivos , Periodo Posparto , Trastornos Relacionados con Opioides/epidemiología , Anticonceptivos
9.
EClinicalMedicine ; 51: 101554, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35865736

RESUMEN

Background: The most widely used copper intrauterine device (IUD) in the world (the TCu380A), and the only product available in many countries, causes side effects and early removals for many users. These problems are exacerbated in nulliparous women, who have smaller uterine cavities compared to parous women. We compared first-year continuation rates and reasons/probabilities for early removal of the TCu380A versus a smaller Belgian copper IUD among nulliparous users. Methods: This 12-month interim report is derived from a pre-planned interim analysis of a sub population and focused on key secondary comparative endpoints. In this participant-blinded trial at 16 centres in the USA, we randomised participants aged 17-40 in a 4:1 ratio to the NT380-Mini or the TCu380A. In the first year, participants had follow-up visits at 6-weeks and 3, 6, and 12-months, and a phone contact at 9 months; we documented continued use, expulsions, and reasons for removal. Among participants with successful IUD placement, we compared probabilities of IUD continuation and specific reasons for discontinuation using log-rank tests. This trial is registered with ClinicalTrials.gov number NCT03124160 and is closed to recruitment. Findings: Between June 1, 2017, and February 25, 2019, we assigned 927 nulliparous women to either the NT380-Mini (n = 744) or the TCu380A (n = 183); the analysis population was 732 (NT380-Mini) and 176 (TCu380A). Participants using the NT380-Mini, compared to the TCu380A, had higher 12-month continuation rates (78·7% [95% CI: 72·9-84·5%] vs. 70·2% [95% CI: 59·7-80·7], p = 0·014), lower rates of removal for bleeding and/or pain (8·1% vs. 16·2%, p = 0·003) and lower IUD expulsion rates (4·8% vs. 8·9%, p = 0·023), respectively. Interpretation: The NT380-Mini offers important benefits for a nulliparous population compared to the TCu380A in the first twelve months, when pivotal experiences typically occur. Higher continuation rates with the NT380-Mini may avert disruptions in contraceptive use and help users avoid unintended pregnancy. Funding: Bill & Melinda Gates Foundation, Eunice Kennedy Shriver National Institute of Child Health and Human Development, and Mona Lisa, N.V. (Belgium).

10.
Am J Obstet Gynecol ; 227(6): 871.e1-871.e7, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35569516

RESUMEN

BACKGROUND: Extending hormonal intrauterine system duration will allow users to have less need for procedures to provide long-term contraception. OBJECTIVE: This study aimed to evaluate the efficacy and safety of the levonorgestrel 52 mg intrauterine system during years 7 and 8 of use. STUDY DESIGN: A total of 1751 nulliparous and multiparous participants aged 16 to 45 years enrolled in a phase 3, multicenter trial to evaluate the efficacy and safety of the use of the Liletta levonorgestrel 52 mg intrauterine system for up to 10 years. Participants aged 36 to 45 years at enrollment underwent safety evaluation only. After the first year, we evaluated participants every 6 months for intrauterine system location confirmation and urine pregnancy testing at each visit. We assessed the Pearl Indices in years 7 and 8 and the life-table analysis for cumulative pregnancy rates through 8 years of use. For the primary efficacy analyses, all participants aged 16 to 35 years at enrollment were included through year 6; years 7 and 8 included only users aged ≤39 years at the start of each use year. Safety outcomes were assessed in all participants regardless of duration of use. We assessed amenorrhea rates, defined as no bleeding or spotting in the 90 days before the end of the year. RESULTS: After intrauterine system placement, we followed 1568 participants aged 16 to 35 years and 146 participants aged 36 to 45 years. The 16- to 35-year-old participants included 986 (57.5%) nulliparous and 433 (25.3%) obese users. Overall, 569 participants started year 7, 478 completed year 7 (380 aged ≤39 years at beginning of year) and 343 completed year 8 (257 aged ≤39 years at beginning of year); 77 completed 10 years of use. Eleven pregnancies occurred over 8 years, 7 (64%) of which were ectopic. Two pregnancies occurred in year 7 (Pearl Index, 0.49; 95% confidence interval, 0.06-1.78), 1 in a participant with implantation 4 days after a desired removal; no pregnancies occurred in year 8. The cumulative life-table pregnancy rate in the primary efficacy population through year 8 was 1.32 (95% confidence interval, 0.69-2.51); without the postremoval pregnancy, the rate was 1.09 (95% confidence interval, 0.56-2.13). Two perforations (0.1%) occurred, none noted after year 1. Expulsion occurred in 71 (4.1%) participants overall, with 3 in year 7 and 2 in year 8. Pelvic infection was diagnosed in 16 (0.9%) participants during intrauterine system use, 1 each in years 7 and 8. Only 44 (2.6%) participants overall discontinued because of bleeding complaints (4 total in years 7 and 8) with rates per year of 0.1% to 0.5% for years 3 to 8. Amenorrhea rates were 39% at both years 7 and 8. CONCLUSION: The levonorgestrel 52 mg intrauterine system is highly effective over 8 years of use and has an excellent extended safety profile. This report details the longest period of efficacy and safety data for continuous use of a levonorgestrel 52 mg intrauterine system for contraception.


Asunto(s)
Anticonceptivos Femeninos , Dispositivos Intrauterinos Medicados , Embarazo , Femenino , Humanos , Adolescente , Adulto Joven , Adulto , Levonorgestrel , Amenorrea/epidemiología , Anticoncepción
11.
AIDS Patient Care STDS ; 36(3): 97-105, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35289688

RESUMEN

For women in the United States who remain sexually active beyond child-bearing years, susceptibility to HIV infection remains, yet condom use is low. We assessed acceptability of the dapivirine vaginal ring (ring) among 96 postmenopausal US women enrolled in a placebo-controlled multisite phase II trial of the ring, using questionnaires and in-depth interviews. Three quarters of women reported "perfect" adherence (ring never out) over the 3-month trial period. At study exit, the ring was found to be very easy to use by 72%, very comfortable to wear by 65%, and 4% reported it ever interfered with their daily activities. The most common worries among participants at preinitiation had decreased significantly at study exit (e.g., worries about inserting the ring declined from 46% to 6%, discomfort during daily activities from 53% to 3%, ring not staying in place from 48% to 14%, all p < 0.0001). Despite some couples feeling the ring during sex, the ring was perceived as more suitable than condoms for prevention because it was not burdensome to use, did not interfere with erection, and provided (for some) additional vaginal lubrication. The ring is a promising, highly acceptable HIV prevention method that is suitable to the lives of postmenopausal women and their male partners and can provide them with an additional prevention choice. Clinical Trials Registration: NCT02010593.


Asunto(s)
Fármacos Anti-VIH , Dispositivos Anticonceptivos Femeninos , Infecciones por VIH , Fármacos Anti-VIH/uso terapéutico , Femenino , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/epidemiología , Infecciones por VIH/prevención & control , Humanos , Masculino , Posmenopausia , Pirimidinas
12.
PLoS One ; 17(2): e0263664, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35192655

RESUMEN

Given challenges with adherence to existing HIV prevention products, the development of an extended duration vaginal ring could improve adherence while reducing patient and provider burden. Additionally, women have other interlinked sexual health concerns such as unintended pregnancy. We evaluated acceptability of a 90-day ring to prevent HIV and hypothetical preferences for a dual (HIV and contraceptive) indication. This was a secondary analysis of a Phase 1, two-arm, multi-site, placebo-controlled randomized trial evaluating safety and pharmacokinetics of a 90-day vaginal ring containing tenofovir for HIV prevention (N = 49). We used a mixed methods approach to assess quantitative data on acceptability (n = 49) and used qualitative data from a random subset to explain the quantitative findings (N = 25). The 3-month extended duration tenofovir ring was highly acceptable. Participants perceived the ring to be easy to use, comfortable and reported liking it more over time. About half felt the ring during sex but most of those participants said it bothered them only a little. Concerns about hygiene increased over the study period but were often outweighed by the benefits of an extended duration ring. Interest in a multi-purpose ring was high (77%) and even higher among those who were sexually active and had male partners. The 3-month extended duration tenofovir ring for HIV prevention was highly acceptable among women and interest in an MPT was high.


Asunto(s)
Fármacos Anti-VIH/uso terapéutico , Dispositivos Anticonceptivos Femeninos , Infecciones por VIH/prevención & control , Aceptación de la Atención de Salud/psicología , Profilaxis Pre-Exposición/métodos , Tenofovir/uso terapéutico , Administración Intravaginal , Adulto , Coito/fisiología , Femenino , Infecciones por VIH/psicología , Infecciones por VIH/virología , Humanos , Masculino , Aceptación de la Atención de Salud/estadística & datos numéricos , Embarazo , Embarazo no Planeado
13.
AIDS Res Hum Retroviruses ; 38(4): 313-326, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34969254

RESUMEN

Vaginal rings address a critical need for an independently initiated, long-acting HIV prevention method, but their design must be acceptable to promote uptake and adherence. Human-centered design (HCD) may help address design preference questions. In two Phase I studies of vaginal rings for HIV prevention conducted in the United States, we used qualitative interviews to assess participants' perceptions and opinions of the physical characteristics of the ring they used and of a ring's physical characteristics after comparing four ring designs presented via a visual tool. Users were found to prefer ring designs that appear easy to use, are physically comfortable, that function well, and are aesthetically pleasing. The parameters for these features varied widely. Product developers and marketers should consider marketing messages in which the target users feel this product is made to meet their needs and desires. Product developers are encouraged to design using HCD early in ring development (Clinical Trial Registration number: NCT03234400 and NCT03670355).


Asunto(s)
Dispositivos Anticonceptivos Femeninos , Infecciones por VIH , Femenino , Infecciones por VIH/prevención & control , Humanos
14.
AIDS Res Hum Retroviruses ; 38(4): 269-278, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34384282

RESUMEN

The Combination HIV Antiretroviral Rectal Microbicide-3 (CHARM-03) study was a randomized, open-label, crossover Phase 1 safety and pharmacokinetic (PK) study of oral maraviroc (MVC) and MVC 1% gel. At a single site, healthy HIV-uninfected men and women were enrolled and randomized to an open label crossover sequence of eight consecutive daily exposures to MVC 300 mg dosed orally, MCV 1% gel dosed rectally, and MVC 1% gel dosed vaginally. Male participants received oral and rectal dosing and female participants received oral, rectal, and vaginal dosing. Assessments were undertaken at baseline and following each 8-day period and included collection of plasma, rectal/cervical tissue (CT), and rectal/endocervical/vaginal fluids. Eleven men and nine women were enrolled. Two participants withdrew from the study before receiving study product. There were 25 adverse events, of which 24 were Grade 1 (G1) and one was G2 (unrelated). After eight doses, MVC was quantifiable in all samples following oral, rectal, or vaginal product administration. The highest drug concentrations in plasma, rectal tissue (RT), and CT were associated with oral, rectal, and vaginal drug delivery, respectively. There were significant reductions in tissue drug concentrations when rectal and cervical biopsies were incubated in media before tissue processing for PK (p < .0001). Only oral MVC was associated with limited protection in the rectal explant HIV challenge model (p < .05). There were no immunological changes in RT, and all products were acceptable to participants. In conclusion, all products were found to be safe and acceptable and did not induce local inflammation. The lack of ex vivo efficacy demonstrated in study samples may be due to rapid disassociation of MVC from the explant tissue. ClinicalTrials.gov Identifier: NCT02346084.


Asunto(s)
Fármacos Anti-VIH , Antiinfecciosos , Infecciones por VIH , Fármacos Anti-VIH/farmacología , Antiinfecciosos/uso terapéutico , Antirretrovirales/uso terapéutico , Ciclohexanos/efectos adversos , Femenino , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/prevención & control , Humanos , Masculino , Maraviroc/efectos adversos
15.
J Infect Dis ; 225(12): 2208-2218, 2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-34865071

RESUMEN

BACKGROUND: A 25-mg dapivirine vaginal ring has been demonstrated to reduce risk of human immunodeficiency virus (HIV) acquisition in nonpregnant adult women. In this secondary analysis of studies conducted in US adolescent, lactating, and postmenopausal females, vaginal microbiota was assessed prior to and after ring use, and between dapivirine and placebo ring users. METHODS: Vaginal fluid swabs were collected before and after product use for the evaluation of microbiota using Nugent criteria, quantitative culture, and quantitative polymerase chain reaction. RESULTS: Vaginal ring use did not impact bacterial vaginosis prevalence among the 3 populations and was associated with minimal shifts in microbiota. Adolescents in both arms demonstrated an increased prevalence of Lactobacillus crispatus and a decrease in quantity of Megasphaera lornae. Postmenopausal active and placebo ring users demonstrated an increased prevalence of lactobacilli and non-albicans yeast, while dapivirine ring users demonstrated an increased prevalence of Candida albicans and increased quantity of group B Streptococcus and non-albicans yeasts. Prevotella species were increased in lactating women, whereas Prevotella timonensis increased in prevalence and concentration among adolescent and postmenopausal females and Prevotella bivia increased in prevalence among adolescent dapivirine ring users. CONCLUSIONS: Dapivirine vaginal ring use was associated with minimal changes in the vaginal microbiota that are likely not clinically significant.


Asunto(s)
Dispositivos Anticonceptivos Femeninos , Microbiota , Adolescente , Adulto , Femenino , Humanos , Lactancia , Posmenopausia , Pirimidinas , Vagina/microbiología
16.
Contraception ; 104(4): 444-446, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34186040

RESUMEN

The expected trend in serum beta-human chorionic gonadotropin (ß-hCG) following treatment of an undesired heterotopic pregnancy with uterine aspiration and systemic methotrexate is not known. Thus, monitoring for treatment success is challenging. We describe an undesired heterotopic pregnancy treated with aspiration and two-dose methotrexate and report the observed ß-hCG trend.


Asunto(s)
Abortivos no Esteroideos , Embarazo Heterotópico , Gonadotropina Coriónica , Gonadotropina Coriónica Humana de Subunidad beta , Femenino , Humanos , Metotrexato , Embarazo , Embarazo Heterotópico/diagnóstico por imagen , Embarazo Heterotópico/tratamiento farmacológico , Estudios Retrospectivos , Útero
17.
EClinicalMedicine ; 36: 100893, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34041459

RESUMEN

BACKGROUND: Daily oral emtricitabine (FTC, F)/tenofovir disoproxil fumarate (TDF) combination is approved for HIV pre-exposure prophylaxis (PrEP) in men and women. Tenofovir alafenamide fumarate (TAF) is a newer, more potent prodrug of tenofovir (TFV), and in combination with FTC, has recently been approved for prevention of HIV through rectal transmission. METHODS: This Phase I, prospective, interventional, randomized study was conducted in three clinical sites: PROFAMILIA, Santo Domingo, Dominican Republic; University of Pittsburgh and Eastern Virginia Medical School. We assessed the multi-compartmental pharmacokinetics (primary outcome) and safety (secondary outcome) among HIV uninfected women randomized to F/TDF (200mg/300mg) or F/TAF (200mg/25mg; F/TAF25) (n=24) in a single dose phase (SDP) and F/TDF, F/TAF (200mg/10mg; F/TAF10), or F/TAF25 (n=75) in a multiple dose (14 daily doses) phase (MDP). We described PK parameters in plasma, peripheral blood mononuclear cells (PBMCs), and cervicovaginal (CV) and rectal fluids and tissues. ClinicalTrials.gov #NCT02904369, completed. FINDINGS: Recruitment for the study began on 5 October 2016. The first participant was enrolled on 6 October 2016 and the last participant completed the study 21 November 2017. PLASMA: TFV concentrations area under curve (AUC) were ~20 fold lower following F/TAF versus F/TDF. TFV-diphosphate (TFV-DP) AUC concentrations in PBMCs were 7-fold higher with F/TAF25 versus F/TDF. Median TFV-DP concentrations in vaginal tissue (4hours post last dose) were approximately 6-fold higher with F/TAF25 versus F/TDF. TFV and TFV-DP were lower with F/TAF versus F/TDF in rectal tissue. Concentrations of FTC and FTC-triphosphate (FTC-TP) were similar across matrices and treatment arms. Gastrointestinal adverse events (AEs) occurred more frequently in F/TDF users (44.0%) than in either F/TAF group (11.5 and 12.0%). INTERPRETATION: F/TAF was safe and well-tolerated. TFV-DP concentrations were higher in PBMCs and similar or higher (4h post dose) in female genital tract tissues for F/TAF versus F/TDF. High FTC and FTC-TP concentrations in all compartments support the potential of F/TAF as a new PrEP combination for women.

18.
J Law Biosci ; 7(1): lsaa013, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32728460

RESUMEN

In response to the COVID-19 pandemic, states have ordered the cessation of non-essential healthcare. Unfortunately, many conservative states have sought to capitalize on those orders to halt abortion care. In this short paper, we argue that abortion should not fall under any state's non-essential healthcare order. Major medical organizations recognize that abortion is essential healthcare that must be provided even in a pandemic, and the law recognizes abortion as a time-sensitive constitutional right. Finally, we examine the constitutional arguments as to why enforcing these orders against abortion providers should not stand constitutional scrutiny. We conclude that no public health purpose can be served by this application because abortion uses less scarce resources and involves fewer contacts with healthcare professionals than prenatal care and delivery assistance, which is continuing to be provided in this public health emergency.

19.
J Womens Health (Larchmt) ; 29(12): 1586-1595, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32667847

RESUMEN

Background: There is little research examining adherence to practice guidelines for long-acting reversible contraception (LARC). We assessed same-day LARC provision and adherence to other guideline-recommended practices among providers in a large academic health care system. Materials and Methods: We surveyed 363 providers who had billed using LARC-related codes within the prior 12 months. Primary outcomes were, for women requesting an intrauterine device (IUD) or implant, the typical number of visits for method provision and ability to add an insertion procedure to an annual examination. We used chi-square tests and multivariable logistic regression to identify characteristics associated with primary outcomes and described other practices and barriers to same-day LARC. Results: Our response rate was 42% (153/363). A typical single visit for women requesting an IUD or implant was reported by 37% of IUD providers and 51% of implant providers, respectively, and was associated with obstetrician-gynecologist specialty versus family medicine (IUD: 44% vs. 12%, p = 0.001; implant: 57% vs. 26%, p = 0.002) and practicing in the county of the main academic medical center versus any other county (IUD: 48% vs. 20%, p = 0.001; implant: 65% vs. 27%, p < 0.001). High ability to add LARC insertion to an annual examination was reported by 48% of IUD providers and 51% of implant providers, with similar associations of specialty and county. Barriers to same-day LARC included scheduling constraints, insurance and billing concerns, and device stocking. Nearly all respondents provide LARC to nulliparous women and adolescents. Among IUD providers, 73% schedule routine follow-up after insertion. Conclusions: Same-day LARC provision is low among providers in a large academic health care system. Provider-identified barriers suggest interventions to improve LARC access, including incentivizing device stocking and billing and insurance education.


Asunto(s)
Anticoncepción/estadística & datos numéricos , Anticonceptivos Femeninos/administración & dosificación , Anticonceptivos Femeninos/uso terapéutico , Adhesión a Directriz/estadística & datos numéricos , Personal de Salud/psicología , Dispositivos Intrauterinos , Anticoncepción Reversible de Larga Duración/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Adulto , Anticoncepción/métodos , Estudios Transversales , Atención a la Salud , Servicios de Planificación Familiar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Embarazo , Encuestas y Cuestionarios , Estados Unidos
20.
J Acquir Immune Defic Syndr ; 85(2): 182-188, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32568766

RESUMEN

BACKGROUND: Depot medroxyprogesterone acetate (DMPA) is a commonly used contraceptive in areas where use of tenofovir disoproxil fumarate and emtricitabine for HIV pre-exposure prophylaxis (PrEP) is increasing. OBJECTIVES: We aimed to investigate the impact of DMPA on PrEP drug pharmacokinetics and pharmacodynamics in women using PrEP before and after DMPA administration. METHODS: In this pilot study, 12 HIV-negative women ages 18-45 underwent biological sample collection at 3 time points: before study drug, after 2 weeks of daily PrEP use alone, and after 2 weeks of daily PrEP and concomitant DMPA use. We measured drug and drug metabolites in plasma, peripheral blood mononuclear cells, cervicovaginal fluid, cervical tissue, and rectal fluid after each 2-week course of PrEP. We measured HIV replication ex vivo in genital tissue biopsies and innate anti-HIV activity in cervicovaginal fluid before PrEP and after both courses. We compared drug concentrations after PrEP alone to after PrEP and DMPA in the same participant using Wilcoxon signed-rank tests. We used mixed effects linear regression models to compare pharmacodynamic measures for each participant at predrug baseline, after PrEP alone, and after PrEP and DMPA. RESULTS: We found no significant differences in PrEP drug and drug metabolite concentrations in any compartment during concomitant DMPA use compared with use of PrEP alone, except for a reduction in emtricitabine concentration in cervical tissue. We found no difference in HIV replication in cervical tissue or anti-HIV activity in cervicovaginal fluid during concomitant DMPA and PrEP use compared with during PrEP use alone. CONCLUSIONS: Concomitant use of DMPA does not clinically alter pharmacokinetics or pharmacodynamics of PrEP in women. These data support the safety of DMPA use in women using PrEP.


Asunto(s)
Fármacos Anti-VIH/uso terapéutico , Infecciones por VIH/tratamiento farmacológico , Acetato de Medroxiprogesterona/farmacología , Profilaxis Pre-Exposición/métodos , Adolescente , Adulto , Emtricitabina/uso terapéutico , Femenino , Humanos , Leucocitos Mononucleares , Persona de Mediana Edad , Proyectos Piloto , Tenofovir/uso terapéutico , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...