Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Mol Sci ; 24(8)2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37108698

RESUMEN

Chondrocyte phenotype and energy metabolism are altered in osteoarthritis (OA). However, most studies characterising the change in human chondrocyte behaviour in OA have been conducted in supraphysiological oxygen concentrations. The purpose of this study was to compare phenotype and energy metabolism in chondrocytes from macroscopically normal (MN) and OA cartilage maintained in 18.9% (standard tissue culture), 6% (equivalent to superficial zone of cartilage in vivo) or 1% oxygen (equivalent to deep zone of cartilage in vivo). MMP13 production was higher in chondrocytes from OA compared to MN cartilage in hyperoxia and physoxia but not hypoxia. Hypoxia promoted SOX9, COL2A1 and ACAN protein expression in chondrocytes from MN but not OA cartilage. OA chondrocytes used higher levels of glycolysis regardless of oxygen availability. These results show that differences in phenotype and energy metabolism between chondrocytes from OA and MN cartilage differ depending on oxygen availability. OA chondrocytes show elevated synthesis of cartilage-catabolising enzymes and chondrocytes from MN cartilage show reduced cartilage anabolism in oxygenated conditions. This is relevant as a recent study has shown that oxygen levels are elevated in OA cartilage in vivo. Our findings may indicate that this elevated cartilage oxygenation may promote cartilage loss in OA.


Asunto(s)
Cartílago Articular , Hiperoxia , Osteoartritis , Humanos , Condrocitos/metabolismo , Hiperoxia/metabolismo , Osteoartritis/metabolismo , Fenotipo , Cartílago Articular/metabolismo , Hipoxia/metabolismo , Metabolismo Energético , Oxígeno/metabolismo , Células Cultivadas
2.
ACS Nano ; 14(7): 7808-7822, 2020 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-32142248

RESUMEN

Anti-polyethylene glycol (PEG) antibodies are present in many healthy individuals as well as in patients receiving polyethylene glycol-functionalized drugs. Antibodies against PEG-coated nanocarriers can accelerate their clearance, but their impact on nanodrug properties including nanocarrier integrity is unclear. Here, we show that anti-PEG IgG and IgM antibodies bind to PEG molecules on the surface of PEG-coated liposomal doxorubicin (Doxil, Doxisome, LC-101, and Lipo-Dox), resulting in complement activation, formation of the membrane attack complex (C5b-9) in the liposomal membrane, and rapid release of encapsulated doxorubicin from the liposomes. Drug release depended on both classical and alternative pathways of complement activation. Doxorubicin release of up to 40% was also observed in rats treated with anti-PEG IgG and PEG-coated liposomal doxorubicin. Our results demonstrate that anti-PEG antibodies can disrupt the membrane integrity of PEG-coated liposomal doxorubicin through activation of complement, which may alter therapeutic efficacy and safety in patients with high levels of pre-existing antibodies against PEG.


Asunto(s)
Complejo de Ataque a Membrana del Sistema Complemento , Doxorrubicina , Animales , Doxorrubicina/análogos & derivados , Doxorrubicina/farmacología , Liberación de Fármacos , Humanos , Liposomas , Polietilenglicoles , Ratas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...