Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Chin J Physiol ; 66(5): 313-325, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37929342

RESUMEN

The flowers of daylily (Hemerocallis fulva Linn.) have been used as vegetable and medicinal herb for thousands of years in Taiwan and eastern Asia. Daylily flowers have been demonstrated to exert several biomedical properties. In this study, we provided the evidences show that daylily flowers exert anti-inflammatory activity in vitro and improved the sleep quality in vivo. We demonstrated that adult volunteers received water extract of daylily flowers improved sleep quality, sleep efficiency and daytime functioning, while sleep latency was reduced, compared to the adult volunteers received water. In addition, we demonstrated that aqueous and ethanol extracts of daylily flowers inhibited nitric oxide and interleukin-6 production in lipopolysaccharide-activated macrophages. Furthermore, the quantitative high performance liquid chromatography-based analysis showed the rutin content of the aqueous extract, ethanolic extract, ethyl acetate fractions of ethanolic extract, and water fractions of ethanolic extract were 7.27, 23.30, 14.71, and 57.43 ppm, respectively. These results indicate that daylily flowers have the potential to be a nutraceutical for improving inflammatory-related diseases and sleep quality in the future.


Asunto(s)
Hemerocallis , Extractos Vegetales , Calidad del Sueño , Humanos , Flores/química , Hemerocallis/química , Interleucina-6 , Macrófagos , Óxido Nítrico , Extractos Vegetales/farmacología
2.
World J Clin Cases ; 11(7): 1498-1505, 2023 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-36926405

RESUMEN

BACKGROUND: Liver metastasis is the most common form of distant metastasis in colorectal cancer, and the only possible curative treatment for patients with colorectal liver metastases (CRLM) is hepatectomy. However, approximately 25% of patients with CRLM have indications for liver resection at the initial diagnosis. Strategies aimed at downstaging large or multifocal tumors to enable curative resection are appealing. CASE SUMMARY: A 42-year-old man was diagnosed with ascending colon cancer and liver metastases. Due to the huge lesion size and compression of the right portal vein, the liver metastases were initially diagnosed as unresectable lesions. The patient was treated with preoperative transcatheter arterial chemoembolization (TACE) consisting of 5-fluorouracil/Leucovorin/oxaliplatin/Endostar®. After four courses, radical right-sided colectomy and ileum transverse colon anastomosis were performed. Postoperatively, the pathological analysis revealed moderately differentiated adenocarcinoma with necrosis and negative margins. Thereafter, S7/S8 partial hepatectomy was performed after two courses of neoadjuvant chemotherapy. Pathological examination of the resected specimen revealed a pathologically complete response (pCR). Intrahepatic recurrence was detected more than two months after the operation, and the patient was then treated with TACE consisting of irinotecan/Leucovorin/fluorouracil therapy plus Endostar®. Subsequently, the patient was treated with a γ-knife to enhance local control. Notably, a pCR was reached, and the patient's overall survival time was > 9 years. CONCLUSION: Multidisciplinary treatment can promote the conversion of initially unresectable colorectal liver metastasis and facilitate complete pathological remission of liver lesions.

3.
BJS Open ; 7(1)2023 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-36849753

RESUMEN

BACKGROUND: Hepatocellular carcinoma is the sixth most common malignancy in the world. Major hepatectomy (resection of greater than or equal to three liver segments) is needed if a tumour is large or close to major blood vessels. Despite low mortality, open major hepatectomy is associated with high rates of tumour recurrence that limits survival. Laparoscopic major hepatectomy has been proposed as an alternative approach with potential oncological benefits. This study compares laparoscopic major hepatectomy with open major hepatectomy for hepatocellular carcinoma in a randomized trial. METHODS: The Asia-Pacific multicentre randomized trial of laparoscopic versus open major hepatectomy for hepatocellular carcinoma (AP-LAPO trial) is an open-labelled multicentre randomized trial to be conducted in five centres in the Asia-Pacific region. The study will test the hypothesis that laparoscopic major hepatectomy for hepatocellular carcinoma is associated with less tumour recurrence and better survival compared with open major hepatectomy; the primary outcome being 2-year recurrence-free survival. Secondary outcomes include hospital mortality, postoperative complications according to the Clavien-Dindo classification, time to functional recovery, quality of life, long-term survival, and postoperative serum surgical stress-related cytokines. RESULTS AND CONCLUSION: The AP-LAPO trial will determine whether laparoscopic major hepatectomy offers oncological benefits to patients with hepatocellular carcinoma compared with open major hepatectomy. REGISTRATION NUMBER: NCT04852211 (http://www.clinicaltrials.gov) registered on 21 April 2021. PROTOCOL VERSION: AP-LAPO trial version 01 (1 December 2021).


Asunto(s)
Carcinoma Hepatocelular , Laparoscopía , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/cirugía , Hepatectomía , Recurrencia Local de Neoplasia/epidemiología , Calidad de Vida , Neoplasias Hepáticas/cirugía , Asia/epidemiología , Laparoscopía/efectos adversos
4.
Microbiol Spectr ; 11(1): e0228622, 2023 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-36519888

RESUMEN

Rapid coronavirus disease 2019 (COVID-19) antigen tests can be used to aid in quickly identifying positive cases, which can help mitigate the spread of COVID-19 infection. Using previously characterized Omicron-positive severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), non-Omicron-positive SARS-CoV-2, and negative samples, we evaluated five brands of at-home rapid COVID-19 antigen tests (On/Go at-home COVID-19 rapid antigen self-test, iHealth COVID-19 antigen rapid test, QuickVue SARS antigen test, Abbott BinaxNOW COVID-19 card home test, and InBios SCoV-2 Ag detect rapid self-test). Our results showed that these rapid tests had similar levels of sensitivity to Omicron and non-Omicron variants (On/Go, 76.4% and 71.0%; iHealth, 73.0% and 71.0%; QuickVue, 84.3% and 74.3%; BinaxNOW, 69.7% and 71.0%; and InBios, 66.3% and 64.5%, respectively). In conclusion, rapid COVID-19 antigen tests can continue to be used as part of public health measures to combat the spread of the Omicron variant, as their sensitivity was not significantly affected. IMPORTANCE The emergence of the Omicron variant of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is due to mutations as part of the virus evolution process. These mutations might affect the sensitivity of diagnostic tests that are currently being used to detect the virus. Because rapid coronavirus disease 2019 (COVID-19) antigen tests are commonly used in the general population, it is important to assess their performance in detecting the Omicron variant. Here, we compared the performance of five brands of rapid tests against Omicron and non-Omicron variants using nasopharyngeal swab samples in viral transport media. Our result found no difference in their performance, suggesting no reduction in sensitivity when used to detect the Omicron variant.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , Mutación , Salud Pública
5.
PLoS One ; 17(11): e0276729, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36342921

RESUMEN

Combining diagnostic specimens into pools has been considered as a strategy to augment throughput, decrease turnaround time, and leverage resources. This study utilized a multi-parametric approach to assess optimum pool size, impact of automation, and effect of nucleic acid amplification chemistries on the detection of SARS-CoV-2 RNA in pooled samples for surveillance testing on the Hologic Panther Fusion® System. Dorfman pooled testing was conducted with previously tested SARS-CoV-2 nasopharyngeal samples using Hologic's Aptima® and Panther Fusion® SARS-CoV-2 Emergency Use Authorization assays. A manual workflow was used to generate pool sizes of 5:1 (five samples: one positive, four negative) and 10:1. An automated workflow was used to generate pool sizes of 3:1, 4:1, 5:1, 8:1 and 10:1. The impact of pool size, pooling method, and assay chemistry on sensitivity, specificity, and lower limit of detection (LLOD) was evaluated. Both the Hologic Aptima® and Panther Fusion® SARS-CoV-2 assays demonstrated >85% positive percent agreement between neat testing and pool sizes ≤5:1, satisfying FDA recommendation. Discordant results between neat and pooled testing were more frequent for positive samples with CT>35. Fusion® CT (cycle threshold) values for pooled samples increased as expected for pool sizes of 5:1 (CT increase of 1.92-2.41) and 10:1 (CT increase of 3.03-3.29). The Fusion® assay demonstrated lower LLOD than the Aptima® assay for pooled testing (956 vs 1503 cp/mL, pool size of 5:1). Lowering the cut-off threshold of the Aptima® assay from 560 kRLU (manufacturer's setting) to 350 kRLU improved the assay sensitivity to that of the Fusion® assay for pooled testing. Both Hologic's SARS-CoV-2 assays met the FDA recommended guidelines for percent positive agreement (>85%) for pool sizes ≤5:1. Automated pooling increased test throughput and enabled automated sample tracking while requiring less labor. The Fusion® SARS-CoV-2 assay, which demonstrated a lower LLOD, may be more appropriate for surveillance testing.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , ARN Viral/genética , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Automatización , Sensibilidad y Especificidad
6.
Process Saf Environ Prot ; 167: 695-707, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36185493

RESUMEN

Particulate matter (PMs) from combustion emissions (traffic, power plant, and industries) and the novel coronavirus (COVID-19) pandemic have recently enhanced the development of personal protective equipment against airborne pathogens to protect humans' respiratory system. However, most commercial face masks still cannot simultaneously achieve breathability and high filtration of PMs, bacteria, and viruses. This study used the electrospinning method with polyimide (PI) and polyethersulfone (PES) solutions to form a nanofiber membrane with low-pressure loss and high biocompatibility for high-efficiency bacteria, viruses, and nano-aerosol removal. Conclusively, the optimized nano-sized PI/PES membrane (0.1625 m2/g basis weight) exhibited conspicuous performance for the highest filtration efficiency towards PM from 50 to 500 nm (99.74 %), good filter quality of nano-aerosol (3.27 Pa-1), exceptional interception ratio against 100-nm airborne COVID-19 (over 99 %), and non-toxic effect on the human body (107 % cell viability). The PI/PES nanofiber membrane required potential advantage to form a medical face mask because of its averaged 97 % BEF on Staphylococcus aureus filiation and ultra-low pressure loss of 0.98 Pa by referring ASTM F2101-01. The non-toxic PI/PES filters provide a new perspective on designing excellent performance for nano-aerosols from air pollution and airborne COVID-19 with easy and comfortable breathing under ultra-low air flow resistance.

7.
Epidemiology ; 33(6): 797-807, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-35944149

RESUMEN

BACKGROUND: Marine recruits training at Parris Island experienced an unexpectedly high rate of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, despite preventive measures including a supervised, 2-week, pre-entry quarantine. We characterize SARS-CoV-2 transmission in this cohort. METHODS: Between May and November 2020, we monitored 2,469 unvaccinated, mostly male, Marine recruits prospectively during basic training. If participants tested negative for SARS-CoV-2 by quantitative polymerase chain reaction (qPCR) at the end of quarantine, they were transferred to the training site in segregated companies and underwent biweekly testing for 6 weeks. We assessed the effects of coronavirus disease 2019 (COVID-19) prevention measures on other respiratory infections with passive surveillance data, performed phylogenetic analysis, and modeled transmission dynamics and testing regimens. RESULTS: Preventive measures were associated with drastically lower rates of other respiratory illnesses. However, among the trainees, 1,107 (44.8%) tested SARS-CoV-2-positive, with either mild or no symptoms. Phylogenetic analysis of viral genomes from 580 participants revealed that all cases but one were linked to five independent introductions, each characterized by accumulation of mutations across and within companies, and similar viral isolates in individuals from the same company. Variation in company transmission rates (mean reproduction number R 0 ; 5.5 [95% confidence interval [CI], 5.0, 6.1]) could be accounted for by multiple initial cases within a company and superspreader events. Simulations indicate that frequent rapid-report testing with case isolation may minimize outbreaks. CONCLUSIONS: Transmission of wild-type SARS-CoV-2 among Marine recruits was approximately twice that seen in the community. Insights from SARS-CoV-2 outbreak dynamics and mutations spread in a remote, congregate setting may inform effective mitigation strategies.


Asunto(s)
COVID-19 , Brotes de Enfermedades , Personal Militar , COVID-19/epidemiología , COVID-19/prevención & control , Brotes de Enfermedades/prevención & control , Femenino , Humanos , Masculino , Personal Militar/estadística & datos numéricos , Filogenia , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Estados Unidos/epidemiología
8.
Microorganisms ; 10(5)2022 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-35630476

RESUMEN

Dengue fever, caused by any of four dengue viruses (DENV1-4), is a major global burden. Currently, there is no effective vaccine that prevents infection in dengue naïve populations. We tested the ability of two novel adjuvants (Advax-PEI and Advax-2), using aluminum hydroxide (alum) as control, to enhance the immunogenicity of formalin- or psoralen-inactivated (PIV or PsIV) DENV2 vaccines in mice. Mice were vaccinated on days 0 and 30, and serum samples were collected on days 30, 60, 90, and 101. Neutralizing antibodies were determined by microneutralization (MN) assays, and the geometric mean 50% MN (MN50) titers were calculated. For the PIV groups, after one dose MN50 titers were higher in the novel adjuvant groups compared to the alum control, while MN50 titers were comparable between the adjuvant groups after the second dose. For the PsIV groups, both novel adjuvants induced higher MN50 titers than the alum control after the second dose. Spleen cells were collected on days 45 and 101 for enzyme-linked immunospot (ELISPOT) for IFNγ and IL4. Both PIV and PsIV groups elicited different degrees of IFNγ and IL4 responses. Overall, Advax-2 gave the best responses just ahead of Advax-PEI. Given Advax-2's extensive human experience in other vaccine applications, it will be pursued for further development.

9.
Chem Phys Lipids ; 244: 105191, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35257749

RESUMEN

Curcumin has been incorporated for the development of new products with applicability in food, pharmaceutical and cosmetic fields in Asia, due to the traits of anti-oxidation and anti-inflammatory. In the application of food engineering, high-pressure processing (HPP) can destroy non-covalent bonds and use as a method to inactivate bacteria for extending the perseveration of food. Thus, this study focuses on a novel approach for the microencapsulation of curcumin by the combination of ethanol injection and HPP at the room temperature for stabilizing pure curcumin in aqueous solutions and in liposome. The results revealed that the most optimal curcumin-liposome was prepared by HPP at operational pressure of 200 MPa within 5 mins holding time to obtain the minimum particle size of 281.9 nm, encapsulation efficiency of 87.25% and polydispersity index (PDI) of 0.23. Particle size could reduce to nanoscale (70.65 nm) after 0.5% addition of Tween 80, but the encapsulation efficiency spontaneously decreased to 45.05%. It is an option to produce liposome with nanosize and uniform distribution for the consideration of high drug delivery. Conclusively, HPP process could not only effectively decrease particle size and PDI of liposome but also efficiently sterilize bacteria around concentration of 103 CFU/g.


Asunto(s)
Curcumina , Liposomas , Disponibilidad Biológica , Curcumina/química , Sistemas de Liberación de Medicamentos , Liposomas/química , Tamaño de la Partícula
10.
Environ Technol ; 43(6): 805-814, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32741260

RESUMEN

The adsorption of copper ions on magnetic adsorbents with amino-functionalized polymers (DETA/SiO2/Fe3O4) has been investigated. In addition, the structure and characterization of magnetic nano-adsorbents were confirmed using FTIR, TGA, TEM, VSM, and BET. The results showed that DETA/SiO2/Fe3O4 exhibited a paramagnetic behaviour and could be easily recovered and quickly separated from a suspension solution. The optimum pH level for adsorption of copper ions was proposed to be in the range of pH level from 5 to 6, and the maximum adsorption capacity (qm) and activated energy (Ea) at 298 K was 13.459 mg g-1 and 22.421 kJ mol-1, respectively. The copper ions adsorption behaviour by DETA/SiO2/Fe3O4 was in good agreement with the Langmuir isotherm rather than Freundlich equation. A pseudo-second-order model could best describe the adsorption kinetics, and the optimal condition of copper ions desorption (99%) from DETA/SiO2/Fe3O4 was provided by 1.0 M HNO3. The novel magnetic nano-adsorbents could not only be regenerated by HNO3 solutions but also reused by the recovery of magnetic force without requiring further downstream treatment.


Asunto(s)
Cobre , Contaminantes Químicos del Agua , Adsorción , Iones , Cinética , Fenómenos Magnéticos , Polímeros , Dióxido de Silicio , Contaminantes Químicos del Agua/análisis
11.
Mil Med ; 187(7-8): 802-807, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33861353

RESUMEN

INTRODUCTION: Leptospirosis and rickettsial diseases are global zoonotic diseases. In severe infection cases, mortality can range from 10% to 30%. Currently most epidemiological data available are based on outbreak investigations and hospital-based studies from endemic countries. The U.S. soldiers at military bases in these countries are highly vulnerable due to the fact that most of them are immunologically naïve to these pathogens. No risk assessment of leptospirosis and rickettsial diseases among U.S. military personnel in Honduras is currently available. This study was aimed at determining the prevalence of leptospirosis and rickettsial diseases in U.S. military personnel deployed to Honduras using serological assays. MATERIALS AND METHODS: A cohort of pre- and post-deployment sera from the most recent 1,000 military personnel stationed in Honduras for at least 6 months between 2000 and 2016 was identified for this study. Serum specimens from these eligible subjects were retrieved. All post-deployment serum specimens were screened at a dilution of 1:100 for the presence of IgG antibodies to Leptospira and Rickettsia pathogens. The pre-deployment sera from those individuals with post-deployment IgG antibodies above cutoff (i.e., seropositive) were tested to determine seroconversion. Seroconversion was defined as conversion of an optical density value from below the cutoff (i.e., negative) in a pre-deployed specimen to above the cutoff (i.e., positive) in a post-deployed specimen at a titer of 100. RESULTS: The seropositive post-deployment specimens for antibodies against Leptospira (causing leptospirosis), Rickettsia typhi (causing murine typhus [MT]), spotted fever group rickettsioses (SFGR, causing SFG Rickettsia), Orientia tsutsugamushi (causing scrub typhus [ST]), and Coxiella burnetii (causing Q fever [QF]) were 11.6%, 11.3%, 6%, 5.6%, and 8.0%, respectively. The seroconverted rate in those assigned to Honduras from 2000 to 2016 was 7.3%, 1.9%, 3.9%, 4.3%, and 2.7% for leptospirosis, MT, SFGR, ST, and QF, respectively. Among the seroconverted specimens, 27 showed seroconversion of at least two antibodies. These seroconverted individuals accounted for 8.8% (3 out of 34) of the personnel who looked for medical attention during their deployment. CONCLUSIONS: Our results suggest a leptospirosis seroconversion rate of 7.3%, which is higher than the 0.9% and 3.9% seroconversion in Korea and Japan, respectively. The higher rate of seroconversion indicates potential risk of Leptospira exposure. Additional testing of water samples in the pools and pits around the training sites to locate the infected areas is important to eliminate or reduce future exposure to Leptospira during trainings. The rates of seroconversion for ST, MT, spotted fever Rickettsia, and QF were 4.3%, 1.9%, 3.9%, and 2.7%, respectively, indicating the potential exposure to a variety of rickettsial-related pathogens. Testing of vectors for rickettsial pathogens in the areas could inform effective vector control countermeasures to prevent exposure. Proper precaution and protective measures are needed to better protect military personnel deployed to Honduras.


Asunto(s)
Leptospira , Leptospirosis , Personal Militar , Infecciones por Rickettsia , Tifus por Ácaros , Tifus Endémico Transmitido por Pulgas , Animales , Anticuerpos Antibacterianos , Honduras/epidemiología , Humanos , Inmunoglobulina G , Leptospirosis/epidemiología , Ratones , Infecciones por Rickettsia/epidemiología , Infecciones por Rickettsia/microbiología
12.
Mil Med ; 187(5-6): e655-e660, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-33428750

RESUMEN

INTRODUCTION: Dengue fever, caused by any of the four dengue viruses (DENV1-4), is endemic in more than 100 countries around the world. Each year, up to 400 million people get infected with dengue virus. It is one of the most important arthropod-borne viral diseases. Dengue's global presence poses a medical threat to deploying military personnel and their dependents. An accurate diagnosis followed by attentive supportive care can improve outcomes in patients with severe dengue disease. Dengue diagnostic tests based on PCR and ELISA platforms have been developed and cleared by the U.S. FDA. However, these diagnostic assays are laborious and usually require highly trained personnel and specialized equipment, which presents a significant challenge when conducting operations in austere and resource-constrained areas. InBios International, Inc. (Seattle, WA) has developed two rapid and instrument-free immunochromatographic test prototype devices (multiplex and traditional formats) for dengue diagnosis. MATERIALS AND METHODS: To determine the performance of the InBios immunochromatographic tests, 183 clinical samples were tested on both prototype devices. Both assays were performed without any instruments and the results were read in 20 minutes. RESULTS: The traditional format had better overall performance (sensitivity: 97.4%; specificity: 90%) than the multiplex format (sensitivity: 86.9%; specificity: 63.3%). The traditional format was superior in serotype-specific detection with 100% overall sensitivity for DENV1, DENV3, and DENV4 and 93.3% sensitivity for DENV2 compared to the multiplex format (91.7%, 78.3%, 83.3%, and 96.3% for DENV1, 2, 3, and 4, respectively). The traditional format was easier to read than the multiplex format. The multiplex format was simpler and faster to set up than the traditional format. CONCLUSIONS: The InBios traditional format had a better overall performance and readability profile than the multiplex format, while the multiplex format was easier to set up. Both formats were highly sensitive and specific, were easy to perform, and did not require sophisticated equipment. They are ideal for use in resource-limited settings where dengue is endemic. Based on our overall assessment, the traditional format should be considered for further development and used in the upcoming multicenter clinical trial toward FDA clearance.


Asunto(s)
Dengue , Anticuerpos Antivirales , Dengue/diagnóstico , Ensayo de Inmunoadsorción Enzimática/métodos , Humanos , Técnicas de Amplificación de Ácido Nucleico , Sensibilidad y Especificidad
13.
AJPM Focus ; 1(1): 100003, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36896336

RESUMEN

Introduction: Quarantining is commonly used to mitigate the spread of SARS-CoV-2. However, questions remain regarding what specific interventions are most effective. Methods: After a 2-week home quarantine, U.S. Marine Corps recruits underwent a supervised 2-week quarantine at a hotel from August 11 to September 21, 2020. All recruits were assessed for symptoms through oral questioning and had their temperatures checked daily. Study participants answered a written clinical questionnaire and were tested for SARS-CoV-2 by polymerase chain reaction shortly after arrival in quarantine and on Days 7 and 14. The results were compared with those of a previously reported Marine-supervised quarantine at a college campus from May until July 2020 utilizing the same study, laboratory, and statistical procedures. Results: A total of 1,401 of 1,514 eligible recruits (92.5%) enrolled in the study, 93.1% of whom were male. At the time of enrollment, 12 of 1,401 (0.9%) participants were polymerase chain reaction positive for SARS-CoV-2, 9 of 1,376 (0.7%) were positive on Day 7, and 1 of 1,358 (0.1%) was positive on Day 14. Only 12 of 22 (54.5%) participants endorsed any symptoms on a study questionnaire, and none of the participants had an elevated temperature or endorsed symptoms during daily screening for SARS-CoV-2. Participation rate (92%) was much greater than the approximately 58.8% (1,848 of 3,143) rate observed in the previous Marine-supervised college campus quarantine, suggesting the changing attitudes of recruits during the pandemic (p<0.001). Approximately 1% of participants were quantitative polymerase chain reaction positive after self-quarantine in both studies. Conclusions: Key findings include the shifting attitudes of young adults during the pandemic, the limitations of self-quarantine, and the ineffectiveness of daily temperature and symptom screening to identify SARS-CoV-2‒positive recruits.

14.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 39(5): 524-530, 2021 Oct 01.
Artículo en Inglés, Chino | MEDLINE | ID: mdl-34636199

RESUMEN

OBJECTIVES: To compare the effects of different irradiators on the establishment of osteoradionecrosis of jaw model (ORNJ) to explore an ideal modeling method. METHODS: A total of 33 adult SD rats were included and randomly divided into three groups according to the radiation equipment, namely, the blank control (CN, 3 rats), group A (linear accelerator irradiation, 15 rats), and group B (small-animal irradiator irradiation, 15 rats). Groups A and B were irradiated with daily fractions of 7, 8, and 9 Gy for 5 days and further divided into three subgroups as follows: group A35/B35, 35 Gy; group A40/B40, 40 Gy; and group A45/B45, 45 Gy. The left mandibular molars of the rats were extracted 1 week after irradiation. The rats were sacrificed 3 weeks after tooth extraction, and the mandible specimens were obtained for gross observation, micro-CT scanning, and histological detection to evaluate the success rate of modeling. RESULTS: At 3 weeks after dental extractions, complete gingival healing was found in the regions of dental extractions in groups A35 and A40. However, failed gingival healing and bone exposure were found in groups A45 and B. Hematoxylin and eosin staining showed necrotic bone of the irradiated mandible in groups A40, A45,and B, with success modeling rates of 40% in group A and 93.3% in group B. CONCLUSIONS: Small-animal irradiator irradiation is an ideal device for establishing ORNJ model.


Asunto(s)
Osteorradionecrosis , Animales , Mandíbula , Diente Molar , Osteorradionecrosis/etiología , Ratas , Ratas Sprague-Dawley , Microtomografía por Rayos X
15.
Front Immunol ; 12: 703887, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34367162

RESUMEN

The only licensed dengue vaccine, Dengvaxia®, increases risk of severe dengue when given to individuals without prior dengue virus (DENV) infection but is protective against future disease in those with prior DENV immunity. The World Health Organization has recommended using rapid diagnostic tests (RDT) to determine history of prior DENV infection and suitability for vaccination. Dengue experts recommend that these assays be highly specific (≥98%) to avoid erroneously vaccinating individuals without prior DENV infection, as well as be sensitive enough (≥95%) to detect individuals with a single prior DENV infection. We evaluated one existing and two newly developed anti-flavivirus RDTs using samples collected >6 months post-infection from individuals in non-endemic and DENV and ZIKV endemic areas. We first evaluated the IgG component of the SD BIOLINE Dengue IgG/IgM RDT, which was developed to assist in confirming acute/recent DENV infections (n=93 samples). When evaluated following the manufacturer's instructions, the SD BIOLINE Dengue RDT had 100% specificity for both non-endemic and endemic samples but low sensitivity for detecting DENV seropositivity (0% non-endemic, 41% endemic). Sensitivity increased (53% non-endemic, 98% endemic) when tests were allowed to run beyond manufacturer recommendations (0.5 up to 3 hours), but specificity decreased in endemic samples (36%). When tests were evaluated using a quantitative reader, optimal specificity could be achieved (≥98%) while still retaining sensitivity at earlier timepoints in non-endemic (44-88%) and endemic samples (31-55%). We next evaluated novel dengue and Zika RDTs developed by Excivion to detect prior DENV or ZIKV infections and reduce cross-flavivirus reactivity (n=207 samples). When evaluated visually, the Excivion Dengue RDT had sensitivity and specificity values of 79%, but when evaluated with a quantitative reader, optimal specificity could be achieved (≥98%) while still maintaining moderate sensitivity (48-75%). The Excivion Zika RDT had high specificity (>98%) and sensitivity (>93%) when evaluated quantitatively, suggesting it may be used alongside dengue RDTs to minimize misclassification due to cross-reactivity. Our findings demonstrate the potential of RDTs to be used for dengue pre-vaccination screening to reduce vaccine-induced priming for severe dengue and show how assay design adaptations as well quantitative evaluation can further improve RDTs for this purpose.


Asunto(s)
Anticuerpos Antivirales/sangre , Virus del Dengue/metabolismo , Dengue , Pruebas Diagnósticas de Rutina , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Dengue/sangre , Dengue/diagnóstico , Vacunas contra el Dengue/administración & dosificación , Vacunas contra el Dengue/efectos adversos , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad
17.
Lancet Respir Med ; 9(7): 712-720, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33865504

RESUMEN

BACKGROUND: Whether young adults who are infected with SARS-CoV-2 are at risk of subsequent infection is uncertain. We investigated the risk of subsequent SARS-CoV-2 infection among young adults seropositive for a previous infection. METHODS: This analysis was performed as part of the prospective COVID-19 Health Action Response for Marines study (CHARM). CHARM included predominantly male US Marine recruits, aged 18-20 years, following a 2-week unsupervised quarantine at home. After the home quarantine period, upon arrival at a Marine-supervised 2-week quarantine facility (college campus or hotel), participants were enrolled and were assessed for baseline SARS-CoV-2 IgG seropositivity, defined as a dilution of 1:150 or more on receptor-binding domain and full-length spike protein ELISA. Participants also completed a questionnaire consisting of demographic information, risk factors, reporting of 14 specific COVID-19-related symptoms or any other unspecified symptom, and brief medical history. SARS-CoV-2 infection was assessed by PCR at weeks 0, 1, and 2 of quarantine and participants completed a follow-up questionnaire, which included questions about the same COVID-19-related symptoms since the last study visit. Participants were excluded at this stage if they had a positive PCR test during quarantine. Participants who had three negative swab PCR results during quarantine and a baseline serum serology test at the beginning of the supervised quarantine that identified them as seronegative or seropositive for SARS-CoV-2 then went on to basic training at Marine Corps Recruit Depot-Parris Island. Three PCR tests were done at weeks 2, 4, and 6 in both seropositive and seronegative groups, along with the follow-up symptom questionnaire and baseline neutralising antibody titres on all subsequently infected seropositive and selected seropositive uninfected participants (prospective study period). FINDINGS: Between May 11, 2020, and Nov 2, 2020, we enrolled 3249 participants, of whom 3168 (98%) continued into the 2-week quarantine period. 3076 (95%) participants, 2825 (92%) of whom were men, were then followed up during the prospective study period after quarantine for 6 weeks. Among 189 seropositive participants, 19 (10%) had at least one positive PCR test for SARS-CoV-2 during the 6-week follow-up (1·1 cases per person-year). In contrast, 1079 (48%) of 2247 seronegative participants tested positive (6·2 cases per person-year). The incidence rate ratio was 0·18 (95% CI 0·11-0·28; p<0·001). Among seropositive recruits, infection was more likely with lower baseline full-length spike protein IgG titres than in those with higher baseline full-length spike protein IgG titres (hazard ratio 0·45 [95% CI 0·32-0·65]; p<0·001). Infected seropositive participants had viral loads that were about 10-times lower than those of infected seronegative participants (ORF1ab gene cycle threshold difference 3·95 [95% CI 1·23-6·67]; p=0·004). Among seropositive participants, baseline neutralising titres were detected in 45 (83%) of 54 uninfected and in six (32%) of 19 infected participants during the 6 weeks of observation (ID50 difference p<0·0001). INTERPRETATION: Seropositive young adults had about one-fifth the risk of subsequent infection compared with seronegative individuals. Although antibodies induced by initial infection are largely protective, they do not guarantee effective SARS-CoV-2 neutralisation activity or immunity against subsequent infection. These findings might be relevant for optimisation of mass vaccination strategies. FUNDING: Defense Health Agency and Defense Advanced Research Projects Agency.


Asunto(s)
Anticuerpos Antivirales/sangre , COVID-19/sangre , COVID-19/epidemiología , SARS-CoV-2/inmunología , Adolescente , COVID-19/diagnóstico , Prueba Serológica para COVID-19 , Estudios de Cohortes , Femenino , Humanos , Masculino , Estudios Prospectivos , Cuarentena , Medición de Riesgo , Adulto Joven
19.
Pharmaceutics ; 13(1)2020 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-33374428

RESUMEN

Toxic organic solvent residues and the active substances of thermal degradation (such as anthocyanin and polyphenols) are always a concern with the liposomes produced by traditional techniques. The present study focuses on a new approach for the microencapsulation of Clitoria ternatea petal (CTP) extracts, which contain anthocyanins, by high-pressure processing (HPP) at room temperature. Thus, a series of CTP liposomes were prepared and their physicochemical properties were analyzed by laser granulometry and by scanning electron microscopy (SEM). The results revealed that the average particle size of the liposomes after HPP treatment increased gradually from 300 MPa to 600 MPa, possibly due to the aggregation of liposomes and damage to the phospholipid bilayers. For the preparation of liposomes by the HPP method at 300 MPa, the mean particle size, polydispersity index (PDI), and encapsulation efficiency were 240.7 nm, 0.37, and 77.8%, respectively. The HPP method provided a number of advantages over conventional methods (magnet stirring and ultrasonication) as it could allow liposome preparation with higher encapsulation efficiency, smaller size, and narrower, more reproducible particle size distribution. Conclusively, microencapsulation in the liposomes was successfully achieved with the fast-adiabatic expansion of HPP.

20.
Mil Med ; 185(9-10): e1440-e1446, 2020 09 18.
Artículo en Inglés | MEDLINE | ID: mdl-32789444

RESUMEN

INTRODUCTION: Measles, mumps, and rubella (MMR) and varicella (VAR) vaccines are the two vaccines administered in large recruit training sites (RTS) that require a single-use syringe to be prefilled with the diluent (ie water) before vaccine reconstitution. Since there are no preservatives in either MMR or VAR vaccines, it is critical to maintain the diluent sterile to ensure the sterility of the reconstituted vaccine. The Department of Defense/Defense Health Agency has instructions on reconstitution of lyophilized vaccines and guidelines for their storage. Vaccine manufacturers provide instructions on how to properly store the diluent. However, there is no clear guidance or standard operating procedures regarding the best practice for preparation and storage of the syringes prefilled with diluent. Various RTS across all four services have their respective routines to best fit their vaccination requirements. Currently, there are no available data on the sterility status of the diluent prepared using these various routines before they are used to reconstitute vaccines. MATERIALS AND METHODS: We investigated the sterility of the diluent (ie water) in prefilled syringes prepared using routines practiced at various RTS. Diluent was drawn up into single syringes and was kept under various conditions (4 °C or room temperature for overnight up to 24 hours) used by various RTS. At indicated time, diluent was injected into sterile vials and the sterility of the diluent was determined by monitoring the presence/growth of bacteria (including aerobic bacteria, mycoplasma, and an obligate intracellular bacterium, Coxiella burnetii), fungi, and viruses for up to 21 days after inoculation into proper and specific culture media. Both traditional cell culture and molecular assays were used to demonstrate the presence or absence of contamination that may compromise the sterility of the diluent. RESULTS: Our results demonstrate that the diluent, after being drawn up to fill the syringe, maintains sterility after storage for overnight up to 24 hours at room temperature or 4 °C with or without recapping the syringes, suggesting that current vaccine reconstitution routines practiced at large military RTS are safe. CONCLUSIONS: Our results demonstrate that in spite of variations in current practices used in various RTS, the diluent in the prefilled syringe tested from each site maintains its sterility and was determined to be safe for use in military health system-wide vaccine reconstitution.


Asunto(s)
Jeringas , Vacunación , Vacunas , Humanos , Infertilidad , Paperas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...