Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Analyst ; 139(19): 4846-54, 2014 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-25089836

RESUMEN

Cancer metastasis and drug resistance are important malignant tumor phenotypes that cause roughly 90% mortality in human cancers. Current therapeutic strategies, however, face substantial challenges partially due to a lack of applicable pre-clinical models and drug-screening platforms. Notably, microscale and three-dimensional (3D) tissue culture platforms capable of mimicking in vivo microenvironments to replicate physiological conditions have become vital tools in a wide range of cellular and clinical studies. Here, we present a microfluidic device capable of mimicking a configurable tumor microenvironment to study in vivo-like cancer cell migration as well as screening of inhibitors on both parental tumors and migratory cells. In addition, a novel evaporation-based paper pump was demonstrated to achieve adaptable and sustainable concentration gradients for up to 6 days in this model. This straightforward modeling approach allows for fast patterning of a wide variety of cell types in 3D and may be further integrated into biological assays. We also demonstrated cell migration from tumor spheroids induced by an epidermal growth factor (EGF) gradient and exhibited lowered expression of an epithelial marker (EpCAM) compared with parental cells, indicative of partial epithelial-mesenchymal transition (EMT) in this process. Importantly, pseudopodia protrusions from the migratory cells - critical during cancer metastasis - were demonstrated. Insights gained from this work offer new opportunities to achieve active control of in vitro tumor microenvironments on-demand, and may be amenable towards tailored clinical applications.


Asunto(s)
Modelos Biológicos , Antígenos de Neoplasias/metabolismo , Moléculas de Adhesión Celular/metabolismo , Técnicas de Cultivo de Célula , Línea Celular Tumoral , Movimiento Celular/efectos de los fármacos , Evaluación Preclínica de Medicamentos , Factor de Crecimiento Epidérmico/farmacología , Molécula de Adhesión Celular Epitelial , Transición Epitelial-Mesenquimal/efectos de los fármacos , Humanos , Células MCF-7 , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Paclitaxel/farmacología , ARN Mensajero/metabolismo , Esferoides Celulares/citología , Esferoides Celulares/efectos de los fármacos , Microambiente Tumoral
2.
Clin Chem ; 59(3): 493-501, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23322907

RESUMEN

BACKGROUND: Semen analysis is essential for evaluating male infertility. Besides sperm concentration, other properties, such as motility and morphology, are critical indicators in assessing sperm quality. Nevertheless, rapid and complete assessment of these measures still presents considerable difficulty and involves a range of complex issues. Here we present a microfluidic device capable of quantifying a range of properties of human sperm via the resistive pulse technique (RPT). METHODS: An aperture, designed as a long channel, was used to allow the quantification of various properties as sperm swam through. RESULTS: The time trace of the voltage drop across the aperture during sperm passage contained a wealth of information: the sperm volume was presented by the amplitude of the induced pulse, the swim velocity was evaluated via the duration, and the beat frequency was calculated from the voltage undulation superposed on the pulse signal. The RPT measurement of swim velocity and beat frequency showed a correlation with the same observation in a microscope (R(2) = 0.94 and 0.70, respectively). CONCLUSIONS: The proposed proof of principle enables substantial quantification of the motion-dependent properties of sperm. Because this approach requires only a current/voltage source and data analysis, it is economically advantageous compared with optical methods for characterizing sperm motion. Furthermore, this approach may be used to characterize sperm morphology.


Asunto(s)
Técnicas Analíticas Microfluídicas , Motilidad Espermática , Humanos , Masculino , Vibración
3.
Anal Biochem ; 429(2): 116-23, 2012 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-22813710

RESUMEN

Recent studies have shown that specific rare cells in the blood can serve as an indicator of cancer prognosis, among other purposes. This article demonstrates the concept of separating and detecting rare cells from peripheral blood mononuclear cells via an economical microfluidic disk with a model system. MCF7, labeled with magnetic beads, was used to simulate circulating tumor cells as a target. Jurkat clone E6-1 was used to simulate leukocytes or other cells abundant in human blood. A tailored multistage magnet maximized the magnetic field to ensure optimal trapping efficiency. Results indicate that the yield of detected MCF7 was consistent at approximately 80% when fewer than hundreds of MCF7 cells were mixed in greater than 1 million Jurkat cells. The 80% yield also held for 10 MCF7 in 100 million Jurkat (rarity of 10(7)). Compared with the results from autoMACS, the performance was at least 20% higher and was more independent of the number of Jurkat. The viability of the enriched cells was approximately 90 ± 20%, showing that this method caused little damage to trapped cells. The microfluidic disk should be applicable for separation and detection of various rare cells, such as circulating tumor cells and circulating endothelial cells in human blood.


Asunto(s)
Recuento de Células/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Supervivencia Celular , Células Cultivadas , Humanos , Inmunohistoquímica , Células Jurkat , Leucocitos Mononucleares/citología , Células MCF-7 , Magnetismo , Técnicas Analíticas Microfluídicas/instrumentación , Células Neoplásicas Circulantes
4.
Clin Chem ; 57(4): 586-92, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21296971

RESUMEN

BACKGROUND: Circulating endothelial cells (CECs) in the blood are rare but have been shown to be associated with various diseases. With the ratio of CECs to peripheral blood mononuclear cells (PBMCs) less than 1 part per thousand, their separation from PBMCs and detection are challenging. We present a means of detecting CECs from PBMCs via an economical microfluidic disk with a model cell system [human umbilical vein endothelial cells (HUVECs) in PBMCs], along with demonstration of its efficacy clinically. METHODS: To enrich these rare cells, we used immunomagnetic beads and a tailor-made magnet on the disk. CEC-simulating HUVECs, as target cells, were stained with primary anti-CD146-phycoerythrin antibody and bound with secondary antibody on antiphycoerythrin magnetic beads. PBMCs served as nontarget cells and were labeled with anti-CD45-FITC antibody. RESULTS: When hundreds of HUVECs were mixed in 10(6) PBMCs, 95% of spiked HUVECs were detected. This yield also held for 60 HUVEC in <10(4) PBMCs. We compared data from flow cytometry with that from the disk: CEC counts in 50 µL blood from patients with systemic lupus erythematosus were 61.1 (21.5), significantly higher (P < 0.01) than those of healthy donors, 31.2 (13.3). CONCLUSIONS: The count of CECs is a suitable marker for symptoms of systemic lupus erythematosus. The microfluidic disk system should be a viable platform for detection of CECs.


Asunto(s)
Endotelio Vascular/citología , Microfluídica/instrumentación , Citometría de Flujo , Humanos
5.
Lab Chip ; 11(3): 474-83, 2011 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-21088774

RESUMEN

Cyto-analysis of rare cells often requires separation and detection with each procedure posing substantial challenges. This paper presents a disk-based microfluidic platform for both procedures via an immunomagnetic negative selection process. The microfluidic platform's unique features include a multistage magnetic gradient to trap labeled cells in double trapping areas, drainage of fluid to substantially shorten detection time, and a bin-like regions to capture target cells to facilitate a seamless enumeration process. Proof-of-concept was conducted using MCF7 as target rare cells (stained with anti-cytokeratin-FITC antibodies) spiked into Jurkat Clone E6-1 non-target cells (labeled with anti-CD45-PE and anti-PE BD magnetic beads). Then, mononuclear cells (MNC) from healthy blood donors were mixed with MCF7s, modeling rare cells, and tested in the disk. Results show a non-linear magnetic coupling effect of the multistage magnet substantially increased the trapping efficacy over that of a single magnet, contributing to the depletion rate of Jurkats, which reaches 99.96%. Detection time is extensively shortened by depletion of 95% of non-cell-containing fluid in the collection area. The average yield of detected MCF7 cells is near-constant 60 ± 10% over a wide range of rarity from 10(-3) to 10(-6) and this yield also holds for the MCF7/MNC complex mixture. Comparison with autoMACS and BD IMagnet separators revealed the average yield from the disk (60%) is superior to that of autoMACS (37.3%) and BD IMagnet (48.3%). The advantages of near-constant yield, roughly 30 min of operation, an acceptable level of cell loss, and potentially low cost system should aid in cyto-analysis of rare cells.


Asunto(s)
Separación Inmunomagnética/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Anticuerpos Monoclonales , Línea Celular Tumoral , Humanos , Células Jurkat , Queratinas/análisis , Antígenos Comunes de Leucocito/análisis , Leucocitos
6.
Biosens Bioelectron ; 22(4): 568-74, 2006 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-16997544

RESUMEN

Microfabricated devices for cell lysis have demonstrated many advantages over conventional approaches. Among various design of microdevices that employ electroporation for cytolysis, most utilize Ag/AgCl wires or 2D planar electrodes. Although, simple in fabrication the electric field generated by 2D electrodes decays exponentially, resulting in rather non-uniform forcing on the cell membrane. This paper investigates the effect of electric field generated by 3D cylindrical electrodes to perform cell lysis via electroporation in a microfluidic platform, and compared with that by 2D design. Computational results of the electric field for both 2D and 3D electrode geometries showed that the 3D configuration demonstrated a significantly higher effective volume ratio-volume which electric field is sufficient for cell lysis to that of net throughflow volume. Hence, the efficacy of performing cell lysis is substantially greater for cells passing through 3D than 2D electrodes. Experimentally, simultaneous multi-pores were observed on leukocytes lysed with 3D electrodes, which is indicative of enhanced uniformity of the electric field generated by 3D design. Additionally, a single row of 3D electrode demonstrated a substantially higher lysing percentage (30%) than that of 2D (8%) under that same flow condition. This work should aid in the design of electrodes in performing cell lysis via electroporation.


Asunto(s)
Permeabilidad de la Membrana Celular/efectos de la radiación , Membrana Celular/fisiología , Electroporación/instrumentación , Leucocitos/fisiología , Microelectrodos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas de Cultivo de Célula/instrumentación , Técnicas de Cultivo de Célula/métodos , Membrana Celular/efectos de la radiación , Permeabilidad de la Membrana Celular/fisiología , Células Cultivadas , Campos Electromagnéticos , Electroporación/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Leucocitos/efectos de la radiación , Técnicas Analíticas Microfluídicas/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA