Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Analyst ; 149(7): 1981-1987, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38226658

RESUMEN

MicroRNAs (miRNAs) have emerged as a promising class of biomarkers for early detection of various cancers, including ovarian cancer. However, quantifying miRNAs in human blood samples is challenging owing to the issues of sensitivity and specificity. In this study, hsa-miR-200a-3p of the miR-200a sub-family, which is a biomarker of ovarian cancer, was used as the analyte to demonstrate the analytical capability of an integrated biosensing platform using an extremely sensitive surface-enhanced Raman scattering (SERS) nanotag-nanoaggregate-embedded beads (NAEBs), magnetic nanoparticles (MNPs), a pair of highly specific locked nucleic acid (LNA) probes, and a semi-automated paper-based electrowetting-on-dielectric (pEWOD) device to provide labor-less and thorough sample cleanup and recovery. A sandwich approach where NAEBs are modified by one LNA-1 probe and MNPs are modified by another LNA-2 probe was applied. Then, the target analyte miRNA-200a-3p was introduced to form a sandwich nanocomplex through hybridization with the pair of LNA probes. The pEWOD device was used to achieve short cleanup time and good recovery of the nanocomplex, bringing the total analysis time to less than 30 min. The detection limit of this approach can reach 0.26 fM through SERS detection. The versatility of this method without the need for RNA extraction from clinical samples is expected to have good potential in detecting other miRNAs.


Asunto(s)
Técnicas Biosensibles , MicroARN Circulante , Nanopartículas de Magnetita , Nanopartículas del Metal , MicroARNs , Neoplasias Ováricas , Humanos , Femenino , MicroARNs/análisis , Electrohumectación , Técnicas Biosensibles/métodos , Espectrometría Raman/métodos , Neoplasias Ováricas/diagnóstico , Límite de Detección , Oro
2.
Biosensors (Basel) ; 12(10)2022 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-36291043

RESUMEN

We developed a fast (<20 min), label-free fiber optic particle plasmon resonance (FOPPR) immunosensing method to detect nervous necrosis virus (NNV), which often infects high-value economic aquatic species, such as grouper. Using spiked NNV particles in a phosphate buffer as samples, the standard calibration curve obtained was linear (R2 = 0.99) and the limit of detection (LOD) achieved was 2.75 × 104 TCID50/mL, which is superior to that obtained using enzyme-linked immunosorbent assay (ELISA). By using an enhancement method called fiber optic nanogold-linked immunosorbent assay (FONLISA), the LOD can be further improved to <1 TCID50/mL, which is comparable to that found by the conventional qPCR method. Employing the larvae homogenate samples of NNV-infected grouper, the results obtained by the FOPPR biosensor agree with those obtained by the quantitative polymerase chain reaction (qPCR) method. We also examined pond water samples from an infected container in an indoor aquaculture facility. The lowest detectable level of NNV coat protein was found to be 0.17 µg/mL, which is one order lower than the LOD reported by ELISA. Therefore, we demonstrated the potential of the FOPPR biosensor as an outbreak surveillance tool, which is able to give warning indication even when the trend of larvae death toll increment is still not clear.


Asunto(s)
Lubina , Técnicas Biosensibles , Enfermedades de los Peces , Nodaviridae , Animales , Larva , Inmunoadsorbentes , Estanques , Enfermedades de los Peces/diagnóstico , Fosfatos , Necrosis , Agua
3.
Sensors (Basel) ; 20(24)2020 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-33333831

RESUMEN

When a centrifugation-enriched sample of 100 µL containing the surface-enhanced Raman scattering (SERS) tag-bound bacteria (Salmonella in this study) is siphoned onto a glass slide next to an embedded thermoelectric heating chip, such a sessile droplet is quickly evaporated. As the size of the sample droplet is significantly reduced during the heating process, ionic wind streams from a corona discharge needle, stationed above the sample, sweep across the liquid surface to produce centrifugal vortex flow. Tag-bound Salmonella in the sample are then dragged and trapped at the center of droplet bottom. Finally, when the sample is dried, unlike the "coffee ring" effect, the SERS tag-bound Salmonella is concentrated in one small spot to allow sensitive detection of a Raman signal. Compared with our previous electrohydrodynamic concentration device containing only a corona discharge needle, this thermoelectric evaporation-assisted device is more time-effective, with the time of concentrating and drying about 100 µL sample reduced from 2 h to 30 min. Hence, sample throughput can be accelerated with this device for practical use. It is also more sensitive, with SERS detection of a few cells of Salmonella in neat samples achievable. We also evaluated the feasibility of using this device to detect Salmonella in food samples without performing the culturing procedures. Having spiked a few Salmonella cells into ice cubes and lettuce leaves, we use filtration and ultracentrifugation steps to obtain enriched tag-bound Salmonella samples of 200 µL. After loading an aliquot of 100 µL of sample onto this concentration device, the SERS tag signals from samples of 100 g ice cubes containing two Salmonella cells and 20 g lettuce leaf containing 5 Salmonella cells can be successfully detected.


Asunto(s)
Análisis de los Alimentos/instrumentación , Calefacción , Salmonella , Centrifugación , Filtración , Análisis de los Alimentos/métodos , Microbiología de Alimentos , Espectrometría Raman
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...