Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
ACS Omega ; 9(9): 10160-10168, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38463268

RESUMEN

A simple, feasible, isocratic elution, and stable reversed-phase high performance liquid chromatography method was established and verified. The chromatographic conditions are as follows: EF-C18H, 4.6 × 250 mm, 5 µm column; column temperature 30 °C; for the mobile phase 27.2 g of KH2PO4 and 8.5 g of tetrabutylammonium hydrogen sulfate were taken, 2500 mL of water was added to dissolve, and the pH was adjusted to 6.7 with phosphoric acid:methanol solution with a ratio of 84:16 (V:V). The flow rate was 1.0 mL/min; the injection volume was 10 µL; and the wavelength was 262 nm. According to the current ICH guidelines, the developed method was verified, and the system suitability, specificity, LOD, LOQ, linearity, range, accuracy, repeatability, durability, and solution stability of the proposed method were verified. The validation results demonstrated that the LOQ for the method was 0.05% and the LOD was 0.02%. The content was detected within the concentration range of 300 to 900 µg/mL. The relationship between concentration and measurement was linear, with an r2 of >0.999. The concentration of impurities ranged from 0.3 to 4.5 µg/mL. A good linear correlation was observed within the range of g/mL, with a coefficient of determination r2 greater than 0.999. The accuracy and repeatability met the specified criteria.

2.
Pak J Pharm Sci ; 36(4(Special)): 1281-1290, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37606017

RESUMEN

A new method for the determination of rebamipide in human heparin sodium plasma by LC-MS was established and its methodology was validated. In this method, protein precipitation method was used to pretreat the samples and the rebamipide-d4 isotope of rebamipide was used as the internal standard. In the multi reaction monitoring mode, the electrospray ion source was used as the ionization technolog and LC-MS was used for detection and analysis. The liquid chromatographic conditions were: 00B-4605-AN (Kinetex® XB-C18 100A 50mm × 2.1mm, 5µm); mobile phase A: 0.1% FA and 1 mM NH4FA aqueous solution, mobile phase B: 0.1% FA and 1mM NH4FA 90% ACN solution, flow rate: 0.300mL/min, injection volume: 10uL, column temperature: 30oC, collection time: 3 min, injector temperature control: 5oC. The retention time of rebamipide and rebamipide-d4 were 1.32min and 1.31min, respectively. The lower limit of quantification was 1ng/mL and the calibration map of rebamipide in the concentration range of 1 to 800ng/mL was linear (R2 >0.990, n=11). The CV% values of the inter and intra batch precision of the method were both less than 15.0%. This method has been successfully applied to pharmacokinetic studies to evaluate the main pharmacokinetic parameters of rebamipide.


Asunto(s)
Heparina , Espectrometría de Masas en Tándem , Humanos , Calibración , Cromatografía Liquida
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...