1.
Micromachines (Basel) ; 14(6)2023 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-37374807

RESUMEN

This paper presents a design and optimization method utilizing inductive coupling coils for wireless power transfer in implantable neural recording microsystems, aiming at maximizing power transfer efficiency, which is essential for reducing externally transmitted power and ensuring biological tissue safety. The modeling of inductive coupling is simplified by combining semi-empirical formulations with theoretical models. By introducing the optimal resonant load transformation, the coil optimization is decoupled from an actual load impedance. The complete design optimization process of the coil parameters is given, which takes the maximum theoretical power transfer efficiency as the objective function. When the actual load changes, only the load transformation network needs to be updated instead of rerunning the entire optimization process. Planar spiral coils are designed to power neural recording implants given the challenges of limited implantable space, stringent low-profile restrictions, high-power transmission requirements and biocompatibility. The modeling calculation, electromagnetic simulation and measurement results are compared. The operating frequency of the designed inductive coupling is 13.56 MHz, the outer diameter of the implanted coil is 10 mm and the working distance between the external coil and the implanted coil is 10 mm. The measured power transfer efficiency is 70%, which is close to the maximum theoretical transfer efficiency of 71.9%, confirming the effectiveness of this method.

2.
Sensors (Basel) ; 23(11)2023 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-37299896

RESUMEN

This paper proposes a temperature sensor based on temperature-frequency conversion using 180 nm CMOS technology. The temperature sensor consists of a proportional-to-absolute temperature (PTAT) current generating circuit, a relaxation oscillator with oscillation frequency proportional to temperature (OSC-PTAT), a relaxation oscillator with oscillation frequency independent of temperature (OSC-CON), and a divider circuit cascaded with D flip-flops. Using BJT as the temperature sensing module, the sensor has the advantages of high accuracy and high resolution. An oscillator that uses PTAT current to charge and discharge capacitors to achieve oscillation, and utilizes voltage average feedback (VAF) to enhance the frequency stability of the oscillator is tested. Through the dual temperature sensing process with the same structure, the influence of variables such as power supply voltage, device, and process deviation can be reduced to a certain extent. The temperature sensor in this paper was implemented and tested with a temperature measurement range of 0-100 °C, an inaccuracy of +0.65 °C/-0.49 °C after two-point calibration, a resolution of 0.003 °C, a resolution Figure of Merit (FOM) of 6.7 pJ/K2, an area of 0.059 mm2, and a power consumption of 32.9 µW.


Asunto(s)
Suministros de Energía Eléctrica , Temperatura , Diseño de Equipo , Retroalimentación , Calibración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA