Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Bioengineering (Basel) ; 10(1)2023 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-36671632

RESUMEN

Aortic disease has a significant impact on quality of life. The involvement of the aortic arch requires the preservation of blood supply to the brain during surgery. Deep hypothermic circulatory arrest is an established technique for this purpose, although neurological injury remains high. Additional techniques have been used to reduce risk, although controversy still remains. A three-way cannulation approach, including both carotid arteries and the femoral artery or the ascending aorta, has been used successfully for aortic arch replacement and redo procedures. We developed circuits of the circulation to simulate blood flow during this type of cannulation set up. The CARDIOSIM© cardiovascular simulation platform was used to analyse the effect on haemodynamic and energetic parameters and the benefit derived in terms of organ perfusion pressure and flow. Our simulation approach based on lumped-parameter modelling, pressure-volume analysis and modified time-varying elastance provides a theoretical background to a three-way cannulation strategy for aortic arch surgery with correlation to the observed clinical practice.

2.
World J Crit Care Med ; 10(5): 301-309, 2021 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-34616664

RESUMEN

BACKGROUND: Panton-Valentine leukocidin (PVL) is an exotoxin secreted by Staphylococcus aureus (S. aureus), responsible for skin and soft tissue infections. As a cause of severe necrotising pneumonia, it is associated with a high mortality rate. A rare entity, the epidemiology of PVL S. aureus (PVL-SA) pneumonia as a complication of influenza coinfection, particularly in young adults, is incompletely understood. CASE SUMMARY: An adolescent girl presented with haemoptysis and respiratory distress, deteriorated rapidly, with acute respiratory distress syndrome (ARDS) and profound shock requiring extensive, prolonged resuscitation, emergency critical care and venovenous extracorporeal membrane oxygenation (ECMO). Cardiac arrest and a rare complication of ECMO cannulation necessitated intra-procedure extracorporeal cardiopulmonary resuscitation, i.e., venoarterial ECMO. Coordinated infectious disease, microbiology and Public Health England engagement identified causative agents as PVL-SA and influenza A/H3N2 from bronchial aspirates within hours. Despite further complications of critical illness, the patient made an excellent recovery with normal cognitive function. The coordinated approach of numerous multidisciplinary specialists, nursing staff, infection control, specialist cardiorespiratory support, hospital services, both adult and paediatric and Public Health are testimony to what can be achieved to save life against expectation, against the odds. The case serves as a reminder of the deadly nature of PVL-SA when associated with influenza and describes a rare complication of ECMO cannulation. CONCLUSION: PVL-SA can cause severe ARDS and profound shock, with influenza infection. A timely coordinated multispecialty approach can be lifesaving.

3.
J Cardiovasc Dev Dis ; 8(8)2021 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-34436228

RESUMEN

Total arch replacement remains a very demanding surgical procedure. It can be associated with reasonable long-term outcomes but carries serious perioperative complications. Aortic arch surgery has progressed in recent years to a wider adoption of reproducible and reliable techniques. Conventional open, surgical aortic arch replacement is currently offered to the majority of patients, although hybrid and wholly endovascular techniques are gaining popularity. With regards to open arch replacement, the nuances of surgical technique, the mode of cannulation and the optimal cerebral protection protocols remain a matter of debate. We propose an alternative cannulation approach facilitated by the cooperation between cardiac and vascular surgeons. A three-way arterial cannulation including both carotid arteries and the femoral artery (or ascending aorta) is the key feature of this approach. A case series of complex patients is presented to show both the feasibility and relative safety of a standardised new approach with a 100% technical success rate and a 16% 30-day mortality. The three-way cannulation approach may have a role to play for complex and extensive procedures requiring prolonged cerebral protection. We believe that a shared skill set from cardiac and vascular specialists is essential for the safe management and successful outcomes using this adaptive technique.

4.
J Investig Med High Impact Case Rep ; 9: 2324709620970890, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33472437

RESUMEN

Traditionally, cardiac and vascular surgeons have been treating diseases of the aorta as individual specialists. Neither cardiac nor vascular surgeons have ever considered the aorta as a whole, which can be diseased throughout its length at the same time requiring a more thoughtful and different approach. Aortic dissection and aneurysmal disease may well benefit from a multidisciplinary approach. In the context of this review, we discuss examples of joint operating between cardiac and vascular surgeons that may well become a more routine approach in more units in the future.


Asunto(s)
Enfermedades de la Aorta , Disección Aórtica , Cirujanos , Aorta , Enfermedades de la Aorta/cirugía , Humanos
5.
J Saudi Heart Assoc ; 32(2): 208-212, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33154918

RESUMEN

We discuss a patient who presented with a type B aortic dissection with a retrograde progression in the context of sickle cell anaemia. Given the involvement of the superior mesenteric artery and concern for bowel ischaemia, a delayed approach was considered. Subsequently, a frozen elephant trunk was performed in the hybrid theatre with the back-up of the vascular surgeon for mesenteric protection. A technically demanding procedure followed by a prolonged and challenging postoperative course finally led to a successful outcome. We argue that the case presented is an example of how a close cooperation between professionals can offer additional options to treatment based on a mixture of skills and background to achieve the desired outcome.

7.
Ann Surg ; 268(6): 1113-1118, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-28498233

RESUMEN

OBJECTIVE: To evaluate the effect of using wearable activity monitors (WAMs) in patients with intermittent claudication (IC) within a single-center randomized controlled trial. BACKGROUND: WAMs allow users to set daily activity targets and monitor their progress. They may offer an alternative treatment to supervised exercise programs (SEPs) for patients with IC. METHODS: Thirty-seven patients with IC were recruited and randomized into intervention or control group. The intervention consisted of a feedback-enabled, wrist-worn activity monitor (WAM) in addition to access to SEP. The control group was given access to SEP only. The outcome measures were maximum walking distance (MWD), claudication distance (CD), and quality of life as measured by the VascuQol questionnaire. Participants were assessed upon recruitment, and at 3, 6, and 12 months. RESULTS: Patients in the WAM group showed significant improvement in MWD at 3 and 6 months (80-112 m, to 178 m; P < 0.001), which was sustained at 12 months. The WAM group also increased CD (40 vs 110 m; P < 0.001) and VascuQol score (4.7 vs 5.8; P = 0.004). The control group saw a temporary increase in VascuQol score at 6 months (4.5 vs 4.7; P = 0.028), but no other improvements in MWD or CD were observed. Significantly higher improvements in MWD were seen in the WAM group compared with that in the control group at 6 months (82 vs -5 m; P = 0.009, r = 0.47) and 12 months (69 vs 7.5 m; P = 0.011, r = 0.52). CONCLUSIONS: The study demonstrates the significant, sustained benefit of WAM-led technologies for patients with IC. This potentially resource-sparing intervention is likely to provide a valuable adjunct or alternative to SEP.


Asunto(s)
Terapia por Ejercicio/métodos , Claudicación Intermitente/fisiopatología , Claudicación Intermitente/terapia , Dispositivos Electrónicos Vestibles , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Calidad de Vida , Encuestas y Cuestionarios , Resultado del Tratamiento
8.
EuroIntervention ; 13(12): e1460-e1467, 2017 12 08.
Artículo en Inglés | MEDLINE | ID: mdl-28649951

RESUMEN

AIMS: Video motion analysis (VMA) uses fluoroscopic sequences to derive catheter and guidewire movement, and is able to calculate 2D catheter-tip path length (PL) on the basis of frame-by-frame pixel coordinates. The objective of this study was to validate VMA in coronary angiography as a method of skill assessment. METHODS AND RESULTS: Forty-seven coronary interventions performed by 10 low- (<1,000 cases; group A), five medium- (1,000-4,000; group B) and six high- (>4,000; group C) experience-volume cardiologists were prospectively recorded and analysed using VMA software. Total PL was calculated and procedure, fluoroscopy times, and radiation dose were recorded. Comparisons of PL were made between groups of experience. Groups A, B and C performed 24, 14 and 6 paired (right and left coronary) cannulations, respectively. Calculation of PL was possible in all recorded cases and significantly correlated with procedure (p=<0.001, rho=0.827) and fluoroscopy times (p=<0.001, rho=0.888). Median total path length (combined right and left coronaries) was significantly shorter in group C which used 3,836 pixels of movement (IQR: 3,003-4,484) vs. 10,556 (7,242-31,408) in group A (p=<0.001) and 8,725 (5,187-15,150) in group B (p=0.013). CONCLUSIONS: VMA in coronary angiography is feasible and PL is able to differentiate levels of experience.


Asunto(s)
Angiografía Coronaria/normas , Intervención Coronaria Percutánea/normas , Grabación en Video , Competencia Clínica , Humanos , Evaluación de Procesos, Atención de Salud
9.
Ann Biomed Eng ; 45(5): 1315-1327, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28181002

RESUMEN

Despite the increasing popularity of endovascular intervention in clinical practice, there remains a lack of objective and quantitative metrics for skill evaluation of endovascular techniques. Data relating to the forces exerted during endovascular procedures and the behavioral patterns of endovascular clinicians is currently limited. This research proposes two platforms for measuring tool forces applied by operators and contact forces resulting from catheter-tissue interactions, as a means of providing accurate, objective metrics of operator skill within a realistic simulation environment. Operator manipulation patterns are compared across different experience levels performing various complex catheterization tasks, and different performance metrics relating to tool forces, catheter motion dynamics, and forces exerted on the vasculature are extracted. The results depict significant differences between the two experience groups in their force and motion patterns across different phases of the procedures, with support vector machine (SVM) classification showing cross-validation accuracies as high as 90% between the two skill levels. This is the first robust study, validated across a large pool of endovascular specialists, to present objective measures of endovascular skill based on exerted forces. The study also provides significant insights into the design of optimized metrics for improved training and performance assessment of catheterization tasks.


Asunto(s)
Cateterismo , Competencia Clínica , Procedimientos Endovasculares , Modelos Teóricos , Movimiento (Física) , Máquina de Vectores de Soporte , Humanos
11.
Nat Rev Dis Primers ; 2: 16053, 2016 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-27440162

RESUMEN

Aortic dissection is a life-threatening condition caused by a tear in the intimal layer of the aorta or bleeding within the aortic wall, resulting in the separation (dissection) of the layers of the aortic wall. Aortic dissection is most common in those 65-75 years of age, with an incidence of 35 cases per 100,000 people per year in this population. Other risk factors include hypertension, dyslipidaemia and genetic disorders that involve the connective tissue, such as Marfan syndrome. Swift diagnostic confirmation and adequate treatment are crucial in managing affected patients. Contemporary management is multidisciplinary and includes serial non-invasive imaging, biomarker testing and genetic risk profiling for aortopathy. The choice of approach for repairing or replacing the damaged region of the aorta depends on the severity and the location of the dissection and the risks of complication from surgery. Open surgical repair is most commonly used for dissections involving the ascending aorta and the aortic arch, whereas minimally invasive endovascular intervention is appropriate for descending aorta dissections that are complicated by rupture, malperfusion, ongoing pain, hypotension or imaging features of high risk. Recent advances in the understanding of the underlying pathophysiology of aortic dissection have led to more patients being considered at substantial risk of complications and, therefore, in need of endovascular intervention rather than only medical or surgical intervention.


Asunto(s)
Disección Aórtica/diagnóstico , Disección Aórtica/fisiopatología , Disección Aórtica/cirugía , Mortalidad , Aorta/patología , Aorta/fisiopatología , Biomarcadores/análisis , Procedimientos Quirúrgicos Cardíacos , Dislipidemias/complicaciones , Humanos , Hipertensión/complicaciones , Imagen por Resonancia Magnética/métodos , Síndrome de Marfan/complicaciones , Factores de Riesgo , Tomografía Computarizada por Rayos X/métodos
12.
Genet Med ; 18(11): 1119-1127, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27011056

RESUMEN

PURPOSE: Ehlers-Danlos syndrome (EDS) comprises a group of overlapping hereditary disorders of connective tissue with significant morbidity and mortality, including major vascular complications. We sought to identify the diagnostic utility of a next-generation sequencing (NGS) panel in a mixed EDS cohort. METHODS: We developed and applied PCR-based NGS assays for targeted, unbiased sequencing of 12 collagen and aortopathy genes to a cohort of 177 unrelated EDS patients. Variants were scored blind to previous genetic testing and then compared with results of previous Sanger sequencing. RESULTS: Twenty-eight pathogenic variants in COL5A1/2, COL3A1, FBN1, and COL1A1 and four likely pathogenic variants in COL1A1, TGFBR1/2, and SMAD3 were identified by the NGS assays. These included all previously detected single-nucleotide and other short pathogenic variants in these genes, and seven newly detected pathogenic or likely pathogenic variants leading to clinically significant diagnostic revisions. Twenty-two variants of uncertain significance were identified, seven of which were in aortopathy genes and required clinical follow-up. CONCLUSION: Unbiased NGS-based sequencing made new molecular diagnoses outside the expected EDS genotype-phenotype relationship and identified previously undetected clinically actionable variants in aortopathy susceptibility genes. These data may be of value in guiding future clinical pathways for genetic diagnosis in EDS.Genet Med 18 11, 1119-1127.


Asunto(s)
Colágeno/genética , Síndrome de Ehlers-Danlos/diagnóstico , Síndrome de Ehlers-Danlos/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Adolescente , Adulto , Anciano , Niño , Preescolar , Síndrome de Ehlers-Danlos/fisiopatología , Femenino , Pruebas Genéticas , Genotipo , Humanos , Masculino , Persona de Mediana Edad , Mutación/genética , Patología Molecular/métodos , Fenotipo , Proteínas Serina-Treonina Quinasas/genética , Receptor Tipo I de Factor de Crecimiento Transformador beta , Receptores de Factores de Crecimiento Transformadores beta/genética , Adulto Joven
13.
J Vasc Surg ; 64(5): 1422-1432, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26386511

RESUMEN

OBJECTIVE: Conventional catheter manipulation in the arch and supra-aortic trunks carries a risk of cerebral embolization. This study proposes a platform for detailed quantitative analysis of contact forces (CF) exerted on the vasculature, in order to investigate the potential advantages of robotic navigation. METHODS: An anthropomorphic phantom representing a type I bovine arch was mounted and coupled onto a force/torque sensor. Three-axis force readings provided an average root-mean-square modulus, indicating the total forces exerted on the phantom. Each of the left subclavian, left common carotid, and right common carotid arteries was cannulated within a simulated endovascular suite with conventional (n = 42) vs robotic techniques (n = 30) by two operator groups: experts and novices. The procedure path was divided into three phases, and performance metrics corresponding to mean and maximum forces, force impact over time, standard deviation of forces, and number of significant catheter contacts with the arterial wall were extracted. RESULTS: Overall, median CF were reduced from 1.20 N (interquartile range [IQR], 0.98-1.56 N) to 0.31 N (IQR, 0.26-0.40 N; P < .001) for the right common carotid artery; 1.59 N (IQR, 1.11-1.85 N) to 0.33 N (IQR, 0.29-0.43 N; P < .001) for the left common carotid artery; and 0.84 N (IQR, 0.47-1.08 N) to 0.10 N (IQR, 0.07-0.17 N; P < .001) for the left subclavian artery. Robotic navigation resulted in significant reductions for the mean and maximum forces for each procedural phase. Significant improvements were also seen in other metrics, particularly at the target vessel ostium and for the more anatomically challenging procedural phases. Force reductions using robotic technology were evident for both novice and expert groups. CONCLUSIONS: Robotic navigation can potentially reduce CF and catheter-tissue contact points in an in vitro model, by enhancing catheter stability and control during endovascular manipulation.


Asunto(s)
Aorta Torácica/cirugía , Cateterismo Periférico/instrumentación , Embolia/prevención & control , Procedimientos Endovasculares/instrumentación , Procedimientos Quirúrgicos Robotizados/instrumentación , Accidente Cerebrovascular/prevención & control , Dispositivos de Acceso Vascular , Aorta Torácica/anomalías , Aorta Torácica/fisiopatología , Cateterismo Periférico/efectos adversos , Competencia Clínica , Embolia/etiología , Embolia/fisiopatología , Procedimientos Endovasculares/efectos adversos , Diseño de Equipo , Humanos , Modelos Anatómicos , Destreza Motora , Factores de Riesgo , Procedimientos Quirúrgicos Robotizados/efectos adversos , Estrés Mecánico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/fisiopatología , Análisis y Desempeño de Tareas , Factores de Tiempo , Torque
14.
Vasc Health Risk Manag ; 11: 195-202, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25792841

RESUMEN

Endovascular technologies are rapidly evolving, often requiring coordination and cooperation between clinicians and technicians from diverse specialties. These multidisciplinary interactions lead to challenges that are reflected in the high rate of errors occurring during endovascular procedures. Endovascular virtual reality (VR) simulation has evolved from simple benchtop devices to full physic simulators with advanced haptics and dynamic imaging and physiological controls. The latest developments in this field include the use of fully immersive simulated hybrid angiosuites to train whole endovascular teams in crisis resource management and novel technologies that enable practitioners to build VR simulations based on patient-specific anatomy. As our understanding of the skills, both technical and nontechnical, required for optimal endovascular performance improves, the requisite tools for objective assessment of these skills are being developed and will further enable the use of VR simulation in the training and assessment of endovascular interventionalists and their entire teams. Simulation training that allows deliberate practice without danger to patients may be key to bridging the gap between new endovascular technology and improved patient outcomes.


Asunto(s)
Simulación por Computador , Educación Médica Continua/métodos , Educación de Postgrado en Medicina/métodos , Procedimientos Endovasculares/educación , Errores Médicos/prevención & control , Modelos Cardiovasculares , Cirugía Asistida por Computador/educación , Competencia Clínica , Procedimientos Endovasculares/efectos adversos , Humanos , Capacitación en Servicio , Comunicación Interdisciplinaria , Curva de Aprendizaje , Grupo de Atención al Paciente , Seguridad del Paciente , Factores de Riesgo , Programas Informáticos , Cirugía Asistida por Computador/efectos adversos , Resultado del Tratamiento
15.
Ann Vasc Surg ; 29(4): 841.e1-3, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25744231

RESUMEN

We report a case of leiomyosarcoma of the thoracic aorta in a 49-year-old male patient with history of hypertrophic cardiomyopathy. The only presenting symptom was back pain localized under the left scapula with the frequency and severity of the pain increasing with time. Imaging studies detected the presence of an aortic tumor. The tumor was excised en bloc, and an interposition graft was implanted. The histology showed a fully excised grade 3 leiomyosarcoma. This article discusses features of this rare condition.


Asunto(s)
Aorta Torácica/patología , Cardiomiopatía Hipertrófica/complicaciones , Leiomiosarcoma/patología , Neoplasias Vasculares/patología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aortografía/métodos , Dolor de Espalda/etiología , Implantación de Prótesis Vascular , Cardiomiopatía Hipertrófica/diagnóstico , Humanos , Leiomiosarcoma/complicaciones , Leiomiosarcoma/cirugía , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Neoplasias Vasculares/complicaciones , Neoplasias Vasculares/cirugía
17.
J Vasc Surg ; 61(5): 1321-3, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24423478

RESUMEN

We describe a novel use of an Amplatzer III plug device (St. Jude Medical, St. Paul, Minn) in the treatment of a traumatic arteriovenous fistula between the innominate vein and the origin of the left common carotid artery causing symptomatic right heart failure. A review of the literature indicates this is the first case to describe the use of the Amplatzer III device in this way. We demonstrate immediate closure of fistula radiologically and complete symptomatic resolution at short-term follow-up.


Asunto(s)
Fístula Arteriovenosa/fisiopatología , Fístula Arteriovenosa/terapia , Velocidad del Flujo Sanguíneo/fisiología , Venas Braquiocefálicas/lesiones , Traumatismos de las Arterias Carótidas/terapia , Arteria Carótida Común , Procedimientos Endovasculares , Dispositivo Oclusor Septal , Angiografía , Clavícula/lesiones , Conducta Cooperativa , Diseño de Equipo , Femenino , Fracturas Óseas/complicaciones , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Comunicación Interdisciplinaria , Persona de Mediana Edad
18.
J Vasc Surg ; 60(6): 1499-506, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25264365

RESUMEN

BACKGROUND: The suitability of the proximal landing zone remains one of the main limitations to thoracic endovascular aortic repair (TEVAR). The advent of custom-made scalloped stent grafts widens the endovascular options for patients with challenging anatomy. The objective of this study was to present our early and midterm results of custom-made scalloped thoracic stent grafts. METHODS: Prospectively acquired data relating to patient demographics, procedure details, clinical outcome, and complications were analyzed. In addition, we analyzed preoperative and postoperative computed tomography scans to evaluate aneurysm morphology, graft placement, side-vessel patency, and endoleaks. RESULTS: Twenty-one patients with a median age of 71 years (range, 35-81 years) underwent custom-made scalloped TEVAR, eight of whom had a concomitant hybrid repair. Procedural success was achieved in all cases. Proximal seal was achieved in all cases, with no type I endoleaks. There were no cases of retrograde dissection and no conversions to open repair. The median follow-up period was 36 weeks (range, 3-183 weeks). Two patients died in the hospital. Three patients suffered a stroke. Three patients had a type II endoleak, one of whom had significant sac enlargement requiring reintervention. One patient had a type III endoleak requiring reintervention. There were no cases of graft migration. CONCLUSIONS: Our midterm results show that custom-made scalloped TEVAR is an acceptable treatment of thoracic aortic aneurysms with a short proximal landing zone. Longer term outcome data are required to establish wider use of scalloped thoracic endografts.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Torácica/diagnóstico , Aneurisma de la Aorta Torácica/mortalidad , Aneurisma de la Aorta Torácica/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Accidente Cerebrovascular/etiología , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Grado de Desobstrucción Vascular
19.
J Vasc Surg ; 60(2): 330-6, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24767711

RESUMEN

OBJECTIVE: Late thoracic aneurysms develop in 5% to 12% of patients having undergone open repair for coarctation of the aorta (CoA). We report our early results for thoracic endovascular aortic repair for pseudoaneurysms after CoA repair. METHODS: From 2008 to 2013, data regarding demographics, aneurysm morphology, procedure, and follow-up were collected prospectively on all patients treated for pseudoaneurysms after CoA repair. Retrospective analysis of identified patients was then performed. RESULTS: Thirteen patients (six men, seven women) were treated. Patients were a median age, 45 years (interquartile range (IQR), 39-56; range, 27-66 years, and the median time after CoA repair to aneurysm treatment was 34 years (IQR, 24-40 years). All patients had saccular pseudoaneurysms of the aortic arch, with a median aneurysm size of 4.1 cm (IQR, 3.4-5.1 cm). The left subclavian artery (LSCA) was involved in 10 patients and was occluded at presentation in three. Four patients had concurrent LSCA revascularization with carotid-subclavian bypass, one had aortic arch hybrid repair, and the LSCA was intentionally covered in two patients. Patients underwent thoracic endovascular aortic repair using the conformable TAG (6 of 13; W. L. Gore & Associates, Flagstaff, Ariz), Valiant device (4 of 13; Medtronic, Minneapolis, Minn), and a custom-made Relay endograft with LSCA scallop (4 of 13; Bolton Medical, Barcelona, Spain). Technical success was 100%, with satisfactory deployment of the stent grafts in all patients. There was no 30-day mortality, stroke, or paraplegia. Median follow-up was 15 months (IQR, 9-19 months; range, 1-67 months). Two type II endoleaks from an intercostal artery were managed conservatively, and one type Ib endoleak was treated successfully with distal stent extension. CONCLUSIONS: In this cohort, new-generation stent grafts have good early clinical and radiologic outcomes, avoiding the need for redo open surgery. Management of the LSCA can be tailored to individual patients with new stent graft technology. Long-term follow-up of these patients is crucial to understanding whether endovascular management of this cohort is acceptable.


Asunto(s)
Aneurisma Falso/cirugía , Aneurisma de la Aorta Torácica/cirugía , Coartación Aórtica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Adulto , Aneurisma Falso/diagnóstico , Aneurisma Falso/etiología , Aneurisma de la Aorta Torácica/diagnóstico , Aneurisma de la Aorta Torácica/etiología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Endofuga/terapia , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
20.
Cardiovasc Intervent Radiol ; 37(4): 920-7, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24196270

RESUMEN

PURPOSE: This study evaluates a fully immersive simulated angiosuite for training and assessment of technical endovascular and human factor skills during a crisis scenario. MATERIALS AND METHODS: Virtual reality (VIST-C, Mentice) simulators were integrated into a simulated angiosuite (ORCAMP, Orzone). Teams, lead by experienced (N = 5) or trainee (N = 5) endovascular specialists, performed simulated endovascular ruptured aortic aneurysm repair (rEVAR). Timed performance metrics were recorded as surrogate measures of performance. Participants (N = 22) completed postprocedure questionnaires evaluating face validity, as well as technical and human factor aspects, of the simulation on a Likert scale from 1 (not at all) to 5 (very much). RESULTS: Experienced team leaders were significantly faster than trainees in obtaining proximal control with an intra-aortic occlusion balloon (352 vs. 501 s, p = 0.047) and all completed the procedure within the allotted time, whilst no trainee was able to do so. Total fluoroscopy times were significantly lower in the experienced group (782 vs. 1,086 s, p = 0.016). Realism of the simulated angiosuite was scored highly by experienced team leaders (median 4/5, IQR 4-5). Participants found the simulation useful for acquiring technical (4/5, IQR 4-5) and communication skills (4/5, IQR 4-5) and particularly valuable for enhancing teamwork (5/5, IQR 4-5) and patient safety (5/5, IQR 4-5). CONCLUSION: This study shows feasibility of creation of a crisis scenario in a fully immersive angiosuite simulation and team performance of a simulated rEVAR. Performance metrics differentiated between experienced specialists and trainees, and the realism of the simulation exercise and environment were rated highly by experienced endovascular specialists. This simulation has potential as a powerful training and assessment tool with opportunities to improve team performance in rEVAR through both technical and human factor skills training.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Competencia Clínica , Procedimientos Endovasculares , Capacitación en Servicio , Grupo de Atención al Paciente/organización & administración , Interfaz Usuario-Computador , Procedimientos Quirúrgicos Vasculares/métodos , Adulto , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Encuestas y Cuestionarios , Análisis y Desempeño de Tareas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...