Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Isr Med Assoc J ; 20(5): 269-276, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29761670

RESUMEN

BACKGROUND: Limited information exists about detailed clinical characteristics and management of the small subset of Brugada syndrome (BrS) patients who had an arrhythmic event (AE). OBJECTIVES: To conduct the first nationwide survey focused on BrS patients with documented AE. METHODS: Israeli electrophysiology units participated if they had treated BrS patients who had cardiac arrest (CA) (lethal/aborted; group 1) or experienced appropriate therapy for tachyarrhythmias after prophylactic implantable cardioverter defibrillator (ICD) implantation (group 2). RESULTS: The cohort comprised 31 patients: 25 in group 1, 6 in group 2. Group 1: 96% male, mean CA age 38 years (range 13-84). Nine patients (36%) presented with arrhythmic storm and three had a lethal outcome; 17 (68%) had spontaneous type 1 Brugada electrocardiography (ECG). An electrophysiology study (EPS) was performed on 11 patients with inducible ventricular fibrillation (VF) in 10, which was prevented by quinidine in 9/10 patients. During follow-up (143 ± 119 months) eight patients experienced appropriate shocks, none while on quinidine. Group 2: all male, age 30-53 years; 4/6 patients had familial history of sudden death age < 50 years. Five patients had spontaneous type 1 Brugada ECG and four were asymptomatic at ICD implantation. EPS was performed in four patients with inducible VF in three. During long-term follow-up, five patients received ≥ 1 appropriate shocks, one had ATP for sustained VT (none taking quinidine). No AE recurred in patients subsequently treated with quinidine. CONCLUSIONS: CA from BrS is apparently a rare occurrence on a national scale and no AE occurred in any patient treated with quinidine.


Asunto(s)
Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/fisiopatología , Síndrome de Brugada/epidemiología , Síndrome de Brugada/fisiopatología , Desfibriladores Implantables , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antiarrítmicos/uso terapéutico , Arritmias Cardíacas/terapia , Síndrome de Brugada/terapia , Estudios de Cohortes , Comorbilidad , Electrocardiografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Israel/epidemiología , Masculino , Persona de Mediana Edad , Quinidina/uso terapéutico , Adulto Joven
2.
Europace ; 16(8): 1175-80, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24554524

RESUMEN

AIMS: Implantable cardioverter-defibrillators (ICDs) improve survival in certain high arrhythmic risk populations. However, there are sex differences regarding both the utilization and the benefit of these devices. Using a prospective national ICD registry, we aim to compare the indications for ICD implantation as well as outcomes in implanted women vs. men. METHODS AND RESULTS: All subjects implanted with an ICD or cardiac resynchronization therapy with a defibrillator (CRTD) in Israel between July 2010 and February 2013 were included. A total of 3544 subjects constructed the baseline cohort, of whom 615 (17%) were women. Women had the same age (64 years) and rate of secondary prevention indication (26%) as men. However, women were more likely than men to have significant heart failure symptoms (52 vs. 45%), QRS > 120 ms (41 vs. 36%), and a higher rate of non-ischaemic cardiomyopathy (54 vs. 21%, all P values <0.05). Using multivariate analysis, women were more likely to undergo CRTD implantation (odds ratio = 1.8, P < 0.01). Follow-up data were available for 1518 subjects with a mean follow-up of 12 months. During follow-up, there were no significant differences among genders in the rate of any single or the combined outcomes of appropriate device therapies, heart failure admissions, or death. First-year re-intervention rate was double among women (5.6 vs. 3.0%, P < 0.01). CONCLUSION: In real-world setting, women implanted with an ICD differ significantly from men in their baseline characteristics and in the use of CRTD devices. These, however, did not translate into outcome differences.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Disparidades en el Estado de Salud , Disparidades en Atención de Salud , Prevención Primaria/instrumentación , Prevención Secundaria/instrumentación , Anciano , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Distribución de Chi-Cuadrado , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Hospitalización , Humanos , Israel , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Sistema de Registros , Retratamiento , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...