Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Transplant Proc ; 35(5): 1940-1, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12962856

RESUMEN

UNLABELLED: The mortality of cardiogenic shock (CS) after an acute myocardial infarction (AMI) still remains high. Thrombolysis, PTCA or CABG, when possible, can improve the results, but when all the treatments fail death is almost certain. OBJECTIVE: We investigate the use of the mechanical circulatory assistance (MCA) and heart transplantation (HT) to improve the adverse results in this irreversible situation. METHODS: Among 11 patients with irreversible CS after an AMI we used a MCA (Abiomed BVS-5000). After improvement and hemodynamic stabilization, we performed heart transplantation in 7 patients of mean age 52 years (35-60) including two women. The MCA was univentricular in 7 patients and biventricular in 4. Mean duration of the MCA was 5 days (1-12). RESULTS: Three patients died during the MCA: two due to cerebrovascular accidents and one multiorgan failure. Weaning was possible in one patient. Among Seven transplanted patients one died due to sepsis. Seven (64%) patients are long-term survivors. CONCLUSION: When all the treatments have failed for CS after an AMI, MCA may be used as a bridge to heart transplantation in a select group of patients where the procedure is not contraindicated. The long-term results of 64% survivors in our experience is satisfactory.


Asunto(s)
Trasplante de Corazón/fisiología , Corazón Auxiliar , Infarto del Miocardio/complicaciones , Choque Cardiogénico/terapia , Adulto , Femenino , Trasplante de Corazón/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Choque Cardiogénico/cirugía , Análisis de Supervivencia
2.
Ann Thorac Surg ; 72(6): 2130-2, 2001 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11789815

RESUMEN

We present the case of a patient with vegetations on a pacing lead from a pacemaker implanted 13 years previously. A new surgical technique for removal of infected leads was developed to avoid the increased risk of septic pulmonary embolism. The electrode with vegetations was removed without cardiopulmonary bypass using the direct surgical approach described.


Asunto(s)
Electrodos Implantados/efectos adversos , Endocarditis Bacteriana/cirugía , Marcapaso Artificial/efectos adversos , Infecciones Estafilocócicas/cirugía , Staphylococcus epidermidis , Anciano , Remoción de Dispositivos , Ecocardiografía Transesofágica , Endocarditis Bacteriana/diagnóstico por imagen , Humanos , Masculino , Infecciones Estafilocócicas/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...