Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38703172

RESUMEN

Patients with normal-flow low-gradient (NFLG) severe aortic stenosis present both diagnostic and management challenges, with debate about the whether this represents true severe stenosis and the need for valve replacement. Studies exploring the natural history without intervention have shown similar outcomes of patients with NFLG severe aortic stenosis to those with moderate aortic stenosis and better outcomes after valve replacement than those with low-flow low-gradient severe aortic stenosis. Most studies (all observational) have shown that aortic valve replacement was associated with a survival benefit vs surveillance. Based on available data, the European Society of Cardiology/European Association for Cardio-Thoracic Surgery guidelines and European Association of Cardiovascular Imaging/American Society of Echocardiography suggest that these patients are more likely to have moderate aortic stenosis. This clinical entity is not mentioned in the American Heart Association/American College of Cardiology guidelines. Here we review the definition of NFLG severe aortic stenosis, potential diagnostic algorithms and points of error, the data supporting different management strategies, and the differing guidelines and outline the unanswered questions in the diagnosis and management of these challenging patients.

3.
JACC Cardiovasc Interv ; 17(4): 505-515, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38340102

RESUMEN

BACKGROUND: A single, multitiered valve center designation has been proposed to publicly identify centers with expertise for all valve therapies. The correlation between transcatheter aortic valve replacement (TAVR) and mitral transcatheter edge-to-edge repair (MTEER) procedures is unknown. OBJECTIVES: The authors sought to examine the relationship between site-level volumes and outcomes for TAVR and MTEER. We further explored variability between sites for MTEER outcomes. METHODS: Using the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) national registry, TAVR and MTEER procedures at sites offering both therapies from 2013 to 2022 were examined. Sites were ranked into deciles of adjusted in-hospital and 30-day outcomes separately for TAVR and MTEER and compared. Stepwise, hierarchical multivariable models were constructed for MTEER outcomes, and the median OR was calculated. RESULTS: Between 2013 and 2022, 384,394 TAVRs and 53,274 MTEERs (median annualized volumes: 93.6 and 18.8, respectively) were performed across 453 U.S. sites. Annualized TAVR and MTEER volumes were moderately correlated (r = 0.48; P < 0.001). After adjustment, 14.3% of sites had the same decile rank for TAVR and MTEER 30-day composite outcome, 50.6% were within 2 decile ranks; 35% had more discordant outcomes for the 2 procedures (P = 0.0005). For MTEER procedures, the median OR for the 30-day composite outcome was 1.57 (95% CI: 1.51-1.64), indicating a 57% variability in outcome by site. CONCLUSIONS: There is modest correlation between hospital-level volumes for TAVR and MTEER but low interprocedural correlation of outcomes. For similar patients, site-level variability for mortality/morbidity following MTEER was high. Factors influencing outcomes and "centers of excellence" as a whole may differ for TAVR and MTEER.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estados Unidos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Sistema de Registros , Hospitales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
5.
Struct Heart ; 8(1): 100225, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38283566

RESUMEN

Background: Baseline left ventricular diastolic dysfunction (LVDD) is associated with poor health status in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR), but health status improvement after TAVR appears similar across all grades of LVDD. Here, we aim to examine the relationship between changes in LVDD severity and health status outcomes following TAVR. Methods: Patients who underwent TAVR and had evaluable LVDD at both baseline and 1 year in the PARTNER (Placement of Aortic Transcatheter Valves) 2 SAPIEN 3 registries and PARTNER 3 trial were analyzed. LVDD grade was evaluated using echocardiography core lab data and an adapted definition of American Society of Echocardiography guidelines. Health status was assessed using the Kansas City Cardiomyopathy Questionnaire Overall Summary (KCCQ-OS) score. The association between ΔLVDD severity and ΔKCCQ-OS was examined using linear regression models adjusted for baseline KCCQ-OS. Results: Of 1100 patients, 724 (65.8%), 283 (25.7%), and 93 (8.5%) had grade 0/1, 2, and 3 LVDD at baseline, respectively. At 1 year, LVDD severity was unchanged in 790 (71.8%) patients, improved in 189 (17.2%), and worsened in 121 (11.0%). Among 376 patients with baseline grade 2 or 3 LVDD, 50.3% had improvement in LVDD. In the overall cohort, KCCQ-OS score improved by 21.9 points at 1 year. There was a statistically significant association between change in LVDD severity (improved, unchanged, and worsened) and ΔKCCQ-OS at 1 year (p = 0.007). Conclusions: Change in LVDD grade was associated with change in health status 1 year following TAVR.

6.
J Am Coll Cardiol ; 83(4): 488-499, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38267110

RESUMEN

BACKGROUND: Mitral valve transcatheter edge-to-edge repair (MTEER) was approved in the United States for treatment of functional mitral regurgitation (FMR) based on results from the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) trial. OBJECTIVES: The authors sought to analyze outcomes of MTEER in FMR patients who would have been excluded from COAPT. METHODS: MTEER procedures performed for FMR in the TVT (Transcatheter Valve Therapy) Registry between January 1, 2013, and April 30, 2020, were categorized as "trial-ineligible" if any of the following were present: cardiogenic shock, inotropic support, left ventricular ejection fraction <20%, left ventricular end-systolic dimension >7 cm, home oxygen use, or severe tricuspid regurgitation. Trial-ineligible and trial-eligible groups were compared through 1 year using multivariable models. The primary endpoint was 1-year death or heart failure hospitalization (HFH). RESULTS: Of 6,675 patients who underwent MTEER for FMR, 3,721 (55.7%) were trial-eligible and 2,954 (44.3%) were trial-ineligible. Trial-ineligible patients had lower rates of technical procedural success (86.9% vs 92.6%; P < 0.001) and more frequent in-hospital complications (11.8% vs 5.7%; P < 0.001) compared with trial-eligible patients. A clinically meaningful improvement in health status at 30 days was observed in 78.9% and 77.0% of patients in the trial-ineligible and trial-eligible groups, respectively. There was a higher risk of 1-year death or HFH (HR: 1.73; 95% CI: 1.57-1.91; P < 0.001) in trial-ineligible patients. CONCLUSIONS: Among patients who underwent MTEER for FMR in the TVT Registry, nearly one-half would have been ineligible for the COAPT trial. Health status improvement at 30 days was similar in COAPT-ineligible and COAPT-eligible patients, but trial-ineligible patients had higher 1-year rates of death or HFH.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Volumen Sistólico , Función Ventricular Izquierda , Insuficiencia Cardíaca/cirugía , Choque Cardiogénico
7.
Struct Heart ; 7(6): 100202, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38046858

RESUMEN

Background: The effectiveness of cerebral embolic protection devices (CEPD) in mitigating stroke after transcatheter aortic valve implantation (TAVI) remains uncertain, and therefore CEPD may be utilized differently across US hospitals. This study aims to characterize the hospital-level pattern of CEPD use during TAVI in the US and its association with outcomes. Methods: Patients treated with nontransapical TAVI in the 2019 Nationwide Readmissions Database were included. Hospitals were categorized as CEPD non-users and CEPD users. The following outcomes were compared: the composite of in-hospital stroke or transient ischemic attack (TIA), in-hospital ischemic stroke, death, and cost of hospitalization. Logistic regression models were used for risk adjustment of clinical outcomes. Results: Of 41,822 TAVI encounters, CEPD was used in 10.6% (n = 4422). Out of 392 hospitals, 65.8% were CEPD non-user hospitals and 34.2% were CEPD users. No difference was observed between CEPD non-users and CEPD users in the risk of in-hospital stroke or TIA (adjusted odds ratio (OR) = 0.99 [0.86-1.15]), ischemic stroke (adjusted OR = 1.00 [0.85-1.18]), or in-hospital death (adjusted OR = 0.86 [0.71-1.03]). The cost of hospitalization was lower in CEPD non-users. Conclusions: Two-thirds of hospitals in the US do not use CEPD for TAVI, and no significant difference was observed in neurologic outcomes among patients treated at CEPD non-user and CEPD user hospitals.

8.
J Interv Cardiol ; 2023: 6617035, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38149109

RESUMEN

Background: Despite an association between operator volumes and procedural success, there remains an incomplete understanding of the contemporary utilization and procedural volumes for mitral valve transcatheter edge-to-edge repair (MTEER). We aimed to identify annual operator procedural volumes, temporal trends, and geographic variability for MTEER among Medicare patients in the United States (US). Methods: We queried the National Medicare Provider Utilization and Payment Database for a CPT code (33418) specific for MitraClip device from 2015 through 2019. We analyzed annual operator procedural volumes and incidence and identified longitudinal and geographic trends in MTEER utilization. Results: From 2015 through 2019, a total of 27,034 MTEER procedures were performed among Medicare patients in the US. The nationwide incidence increased from 6.2 per 100,000 patients in 2015 to 23.8 per 100,000 patients in 2019, a 283% increase over the study period (Ptrend < 0.001). The incidence of MTEER by state varied by nearly 900% (range 5.5 to 54.9 per 100,000 person-years). In 2019, the mean annual MTEER operator annual volume was 9.1 MTEER procedures and had grown from 6.2 per year in 2015. Conclusions: In this nationwide study of Medicare beneficiaries in the United States, we identified a significant and sustained increase in the utilization of MTEER devices and operators and growth in annual procedural volumes from 2015 through 2019 with considerable variability in utilization by state. Further studies are needed to understand the clinical impact of variability in utilization and the optimal procedural volumes to ensure high efficacy outcomes and maintain critical access to MTEER therapies.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Humanos , Estados Unidos/epidemiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Medicare , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco
9.
Circ Cardiovasc Interv ; 16(11): e013238, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37988439

RESUMEN

BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Resultado del Tratamiento , Tomografía Computarizada por Rayos X , Diseño de Prótesis
10.
JTCVS Tech ; 21: 45-55, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37854813

RESUMEN

Transaxillary access has been the most frequently used nonfemoral access route for transcatheter aortic valve replacement (TAVR) with a self-expanding valve. Use of transcarotid TAVR is increasing; however, comparative data on these methods are limited. We compared outcomes following transcarotid or transaxillary TAVR with a self-expanding, supra-annular valve. Methods: The Transcatheter Valve Therapy Registry was queried for TAVR procedures using transaxillary and transcarotid access between July 2015 and June 2021. Patients received a self-expanding Evolut R, PRO, or PRO + valve (Medtronic) and had 1-year follow-up. Thirty-day and 1-year outcomes were compared in transcarotid and transaxillary groups after 1:2 propensity score-matching. Multivariable regression models were fitted to identify predictors of key end points. Results: The propensity score-matched cohort included 576 patients receiving transcarotid and 1142 receiving transaxillary access. Median procedure time (99 vs 118 minutes; P < .001) and hospital stay (2 vs 3 days; P < .001) were shorter with transcarotid versus transaxillary access. At 30 days, patients with transcarotid access had similar mortality (Kaplan-Meier estimates 3.7% vs 4.3%, P = .57) but significantly lower stroke (3.1% vs 5.9%; P = .017) and mortality or stroke (6.0% vs 8.9%; P = .033) compared with patients receiving transaxillary access. Similar differences were observed at 1 year. Transaxillary access was associated with increased risk of 30-day stroke (hazard ratio, 2.14; 95% confidence interval, 1.27-3.58) by multivariable regression analysis. Conclusions: Transcarotid versus transaxillary access for TAVR using a self-expanding valve is associated with procedural benefits and significantly lower stroke and mortality or stroke at 30 days. In patients with unsuitable femoral anatomy, transcarotid access may be the preferred delivery route for self-expanding valves.

11.
JACC Cardiovasc Interv ; 16(21): 2631-2641, 2023 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-37737793

RESUMEN

BACKGROUND: Little is known about the outcomes of transcatheter aortic valve replacement (TAVR) in minimally symptomatic patients. OBJECTIVES: The authors aimed to evaluate the outcomes of patients with minimally symptomatic severe aortic stenosis treated with TAVR in the STS/ACC TVT registry. METHODS: Minimally symptomatic status was defined as a baseline Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OS) ≥75. Clinical and health status outcomes of TAVR in patients with severe aortic stenosis and normal left ventricular ejection fraction were compared between minimally symptomatic patients and those with moderate or severe symptoms. RESULTS: Among 231,285 patients who underwent TAVR between 2015 and 2021 (median age 80.0 years [IQR: 74.0-86.0 years], 47.5% female), 20.0% were minimally symptomatic before TAVR. Survival at 1 year was higher in minimally symptomatic patients vs those with moderate or severe symptoms (adjusted HR for death: 0.70 [95% CI: 0.66-0.75]). Mean KCCQ-OS increased by 2.7 points (95% CI: 2.6-2.9 points) at 30 days and 3.8 points (95% CI: 3.6-4.0 points) at 1 year in minimally symptomatic patients compared with increases of 32.2 points (95% CI: 32.0-32.3 points) at 30 days and 34.9 points (95% CI: 34.7-35.0 points) at 1 year in more symptomatic patients. Minimally symptomatic patients had higher odds of being alive and well at 1 year (OR: 1.19 [95% CI: 1.16-1.23]). CONCLUSIONS: Although minimally symptomatic patients treated with TAVR experience only small improvements in health status, their overall outcomes are favorable with a higher likelihood of survival with good health status at 1 year compared with more symptomatic patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Volumen Sistólico , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Función Ventricular Izquierda , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo , Índice de Severidad de la Enfermedad
12.
Catheter Cardiovasc Interv ; 102(3): 521-527, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37493443

RESUMEN

BACKGROUND: There is a paucity of data regarding the comparative efficacy and safety of Mitral valve transcatheter edge-to-edge repair (MTEER) using the PASCAL or MitraClip systems for patients with mitral regurgitation (MR). METHODS: An electronic search was conducted for MEDLINE, COCHRANE, and EMBASE, through February 2023, for studies comparing the clinical outcomes of MTEER using PASCAL versus MitraClip systems among patients with severe MR. The primary study outcome was residual MR ≤ 2 at discharge. Data were pooled using a random-effects model. RESULTS: The final analysis included six studies with a total of 1581 patients, with a weighted follow-up period of 3.5 months. Two studies only included patients with degenerative MR, while the remaining studies included both degenerative and functional MR. There was no significant difference in procedure duration between MTEER with the PASCAL or MitraClip systems. There was no difference in residual MR ≤ 2 at discharge (94.7% vs. 91.9%; odds ratio [OR]: 1.44; 95% confidence interval [CI]: 0.92-2.27) or residual MR ≤ 2 at the mid-term follow-up (94.6% vs. 91.0%, p = 0.05) among the PASCAL versus MitraClip systems. There was no difference between both groups in residual MR ≤ 1 at discharge (73.1% vs. 63.8%, p = 0.12), while there was greater incidence of residual MR ≤ 1 at midterm follow-up with the PASCAL system (71.3% vs. 56.2%, p < 0.001). There was no difference between the PASCAL and MitraClip MTEER systems in technical success (97.0% vs. 97.9%, p = 0.15), procedural success (89.1% vs. 87.1%, p = 0.78), single leaflet detachment (1.8% vs. 1.4%, p = 0.55), or all-cause mortality (3.6% vs. 4.6%, p = 0.71). CONCLUSION: In this meta-analysis, we demonstrated comparable efficacy and safety between the PASCAL and MitraClip MTEER systems at short- and mid-term assessments. Randomized trials are warranted to evaluate the comparative long-term outcomes between both MTEER systems.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos
14.
JACC Cardiovasc Interv ; 16(13): 1594-1608, 2023 07 10.
Artículo en Inglés | MEDLINE | ID: mdl-37294230

RESUMEN

BACKGROUND: There are limited data on the effect of bioprosthetic valve remodeling (BVR) on transcatheter heart valve (THV) expansion and function following valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) in a nonfracturable surgical heart valve (SHV). OBJECTIVES: This study sought to assess the impact of BVR of nonfracturable SHVs on THVs after VIV implantation. METHODS: VIV TAVR was performed using 23-mm SAPIEN3 (S3, Edwards Lifesciences) or 23/26-mm Evolut Pro (Medtronic) THVs implanted in 21/23-mm Trifecta (Abbott Structural Heart) and 21/23-mm Hancock (Medtronic) SHVs with BVR performed with a noncompliant TRUE balloon (Bard Peripheral Vascular Inc). Hydrodynamic assessment was performed, and multimodality imaging including micro-computed tomography was performed before and after BVR to assess THV and SHV expansion. RESULTS: BVR resulted in limited improvement of THV expansion. The largest gain in expansion was observed for the S3 in the 21-mm Trifecta with up to a 12.7% increase in expansion at the outflow of the valve. Minimal change was observed at the level of the sewing ring. The Hancock was less amenable to BVR with lower final expansion dimensions than the Trifecta. BVR also resulted in notable surgical post flaring of up to 17.6°, which was generally more marked with the S3 than with the Evolut Pro. Finally, BVR resulted in very limited improvement in hydrodynamic function. Severe pinwheeling was observed with the S3, which improved slightly but persisted despite BVR. CONCLUSIONS: When performing VIV TAVR inside a Trifecta and Hancock SHV, BVR had a limited impact on THV expansion and resulted in SHV post flaring with unknown consequences on coronary obstruction risk and long-term THV function.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Hidrodinámica , Microtomografía por Rayos X , Diseño de Prótesis , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Instrumentos Quirúrgicos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía
15.
Expert Rev Cardiovasc Ther ; 21(6): 409-422, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37222483

RESUMEN

INTRODUCTION: Valve-in-valve (VIV) transcatheter valve replacement has emerged as a feasible and potentially safer treatment option for failed bioprosthetic surgical valves (BSVs). However, the VIV procedure carries an inherent risk of prosthesis-patient mismatch (PPM). Bioprosthetic valve fracture (BVF) and bioprosthetic valve remodeling (BVR) by either fracturing or stretching the surgical valve ring allows for a more optimal expansion of the transcatheter heart valve (THV) and beneficial effects on post-implant valve hemodynamics and perhaps long-term valve durability. AREAS COVERED: This is an expanded overview of BVF and BVR to facilitate VIV transcatheter aortic valve replacement (TAVR), with detailed discussion on lessons learned from bench testing studies and translation to procedural technique and clinical experience incorporating up-to-date evidence and experience with BVF in non-aortic positions. EXPERT OPINION: BVF and BVR improve valve hemodynamics following VIV-TAVR, with timing of BVF being an important determinant of procedure safety and efficacy; however, longer-term data are needed to determine long-term clinical outcomes including mortality, valve hemodynamics, and valve reintervention. In addition, further research will be needed to understand the safety and efficacy of these procedures in any new generation BSV or THV and to better define the role of these techniques in the pulmonic, mitral, and tricuspid positions.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Falla de Prótesis , Diseño de Prótesis , Bioprótesis/efectos adversos , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/métodos
16.
JACC Cardiovasc Interv ; 16(5): 530-539, 2023 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-36922038

RESUMEN

BACKGROUND: Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) is increasingly used to treat degenerated surgical bioprostheses. Bioprosthetic valve fracture (BVF) has been shown to improve hemodynamic status in VIV TAVR in case series. However, the safety and efficacy of BVF are unknown. OBJECTIVES: The primary objective of this study was to assess the safety and efficacy of VIV TAVR using SAPIEN 3 and SAPIEN 3 Ultra valves with or without BVF using data from the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry. METHODS: The primary outcome was in-hospital mortality. Secondary outcomes included echocardiography-derived valve gradient and aortic valve area. Inverse probability of treatment weighting was used to adjust for baseline characteristics. RESULTS: A total of 2,975 patients underwent VIV TAVR from December 15, 2020, to March 31, 2022. BVF was attempted in 619 patients (21%). In adjusted analyses, attempted BVF was associated with higher in-hospital mortality (OR: 2.51; 95% CI: 1.30-4.84) and life-threatening bleeding (OR: 2.55; 95% CI: 1.44-4.50). At discharge, VIV TAVR with attempted BVF was associated with larger aortic valve area (1.6 cm2 vs 1.4 cm2; P < 0.01) and lower mean gradient (16.3 mm Hg vs 19.2 mm Hg; P < 0.01). When BVF was compared with no BVF according to timing (before vs after transcatheter heart valve implantation), BVF after transcatheter heart valve implantation was associated with improved hemodynamic status and similar mortality. CONCLUSIONS: BVF as an adjunct to VIV TAVR with the SAPIEN 3 and SAPIEN 3 Ultra valves is associated with a higher risk for in-hospital mortality and significant bleeding and modest improvements in echocardiography-derived hemodynamic status. The timing of BVF is an important determinant of safety and efficacy.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Falla de Prótesis , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Factores de Riesgo
17.
EuroIntervention ; 18(14): 1165-1177, 2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-36534495

RESUMEN

BACKGROUND: Bioprosthetic valve fracture (BVF) can be used to improve transcatheter heart valve (THV) haemodynamics following a valve-in-valve (ViV) intervention. However, whether BVF should be performed before or after THV deployment and the implications on durability are unknown.  Aims: We sought to assess the impact of BVF timing on long-term THV durability. METHODS: The impact of BVF timing was assessed using small ACURATE neo (ACn) or 23 mm SAPIEN 3 (S3) THV deployed in 21 mm Mitroflow valves compared to no-BVF controls. Valves underwent accelerated wear testing up to 200 million (M) cycles (equivalent to 5 years). At 200M cycles, THV were evaluated by hydrodynamic testing, second-harmonic generation (SHG) microscopy, scanning electron microscopy (SEM) and histology. RESULTS: At 200M cycles, the regurgitant fraction (RF) and effective orifice area (EOA) for the ACn were 8.03±0.30%/1.74±0.01 cm2 (no BVF), 12.48±0.70%/1.97±0.02 cm2 (BVF before ViV) and 9.29±0.38%/2.21±0.0 cm2 (BVF after ViV), respectively. For the S3 these values were 2.63±0.51%/1.26±0.01 cm2, 2.03±0.42%/1.65±0.01 cm2, and 1.62±0.38%/2.22±0.01 cm2, respectively. Further, SHG and SEM revealed a higher degree of superficial leaflet damage when BVF was performed after ViV for the ACn and S3. However, the histological analysis revealed significantly less damage, as determined by matrix density analysis, through the entire leaflet thickness when BVF was performed after ViV with the S3 and a similar but non-significant trend with the ACn.  Conclusions: BVF performed after ViV appears to offer superior long-term EOA without increased RF. Ultrastructure leaflet analysis reveals that the timing of BVF can differentially impact leaflets, with more superficial damage but greater preservation of overall leaflet structure when BVF is performed after ViV.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Diseño de Prótesis , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
18.
Circ Cardiovasc Interv ; 15(12): e012195, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36538580

RESUMEN

BACKGROUND: Rehospitalization is a common end point in clinical trials of structural heart interventions, but whether rehospitalization is clinically and prognostically relevant in these patients is uncertain. The aim of this study was to evaluate the risk of rehospitalization events after aortic valve replacement (AVR) and their association with mortality and health status. METHODS: The study population included patients who underwent transcatheter or surgical AVR in the PARTNER I' II' and III trials (Placement of Aortic Transcatheter Valves). Health status was assessed with the Kansas City Cardiomyopathy Questionnaire-overall summary score. The primary analysis focused on heart failure hospitalization within 1 year after AVR and its association with mortality, poor outcome (death, Kansas City Cardiomyopathy Questionnaire-overall summary score <60 or decrease by ≥10), and health status at 1 year using adjusted models. Secondary analyses examined the prognostic associations of rehospitalization due to a composite of heart failure, valve-related, or procedure-related causes. RESULTS: Among 3403 patients treated with AVR (2008 transcatheter AVR, 1395 surgical AVR), the 1-year incidence was 6.7% for heart failure hospitalization and 9.7% for rehospitalization due to a composite of heart failure, valve-related, or procedure-related causes. Heart failure hospitalization after AVR was associated with increased risk of 1-year mortality (hazard ratio, 3.97 [2.48 to 6.36]; P<0.001), poor outcome (OR, 2.76 [1.73 to 4.40]; P<0.001), and worse health status (Kansas City Cardiomyopathy Questionnaire-overall summary mean difference -9.8 points [-13.8 to -5.8]; P<0.001). Rehospitalization due to a composite of heart failure, valve-related, or procedure-related causes was similarly associated with increased 1-year mortality (hazard ratio, 4.64 [3.11 to 6.92]; P<0.001), poor outcome (OR, 2.06 [1.38 to 3.07]; P=0.0004), and worse health status (Kansas City Cardiomyopathy Questionnaire-overall summary mean difference -8.8 points [-11.8 to -5.7]; P<0.001). There was no effect modification by treatment type (transcatheter AVR versus surgical AVR) for these associations. CONCLUSIONS: Heart failure hospitalization and rehospitalization after AVR are associated with increased risk of mortality and worse 1-year health status. These findings confirm the clinical and prognostic relevance of rehospitalization end points for trials of AVR. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT00530894.


Asunto(s)
Estenosis de la Válvula Aórtica , Cardiomiopatías , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Cardiomiopatías/complicaciones , Cardiomiopatías/cirugía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Readmisión del Paciente , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...