Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Radiol Phys Technol ; 17(1): 93-102, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37897684

RESUMEN

The aim of this study is to develop a novel phantom for the evaluation of clinical CEST imaging settings, e.g., B0 and B1 field inhomogeneities, CEST contrast, and post-processing. We made a phantom composed of two slice sections: a grid section for local offset frequency evaluation and a sample section for CEST effect evaluation using different concentrations of an egg white albumin solution. On a 3 Tesla MR scanner, a phantom study was performed using CEST imaging; the mean B1 amplitudes were set at 1.2 and 1.9 µT, and CEST images with and without B0 corrections were acquired. Next, region of interest (ROI) analysis was performed for each slice. Then, CEST images with and without B0 corrections were compared at each B1 amplitude. The B0 corrected Z-spectrums at each local region in the grid section showed a shifting of the curve bottom to 0 ppm. Z-spectrum at B1 = 1.9 µT showed a broader curve shape than that at 1.2 µT. Moreover, MTRasym values at 3.5 ppm for each albumin sample at B1 = 1.9 µT were about two times higher than those at 1.2 µT. Our phantom enabled us to evaluate and optimize B0 inhomogeneity and the CEST effect at the B1 amplitude.


Asunto(s)
Albúminas , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
2.
Sens Actuators A Phys ; 349: 114052, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36447950

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been garnered increasing for its rapid worldwide spread. Each country had implemented city-wide lockdowns and immigration regulations to prevent the spread of the infection, resulting in severe economic consequences. Materials and technologies that monitor environmental conditions and wirelessly communicate such information to people are thus gaining considerable attention as a countermeasure. This study investigated the dynamic characteristics of batteryless magnetostrictive alloys for energy harvesting to detect human coronavirus 229E (HCoV-229E). Light and thin magnetostrictive Fe-Co/Ni clad plate with rectification, direct current (DC) voltage storage capacitor, and wireless information transmission circuits were developed for this purpose. The power consumption was reduced by improving the energy storage circuit, and the magnetostrictive clad plate under bending vibration stored a DC voltage of 1.9 V and wirelessly transmitted a signal to a personal computer once every 5 min and 10 s under bias magnetic fields of 0 and 10 mT, respectively. Then, on the clad plate surface, a novel CD13 biorecognition layer was immobilized using a self-assembled monolayer of -COOH groups, thus forming an amide bond with -NH2 groups for the detection of HCoV-229E. A bending vibration test demonstrated the resonance frequency changes because of HCoV-229E binding. The fluorescence signal demonstrated that HCoV-229E could be successfully detected. Thus, because HCoV-229E changed the dynamic characteristics of this plate, the CD13-modified magnetostrictive clad plate could detect HCoV-229E from the interval of wireless communication time. Therefore, a monitoring system that transmits/detects the presence of human coronavirus without batteries will be realized soon.

3.
Materials (Basel) ; 14(16)2021 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-34443009

RESUMEN

The severe acute respiratory syndrome coronavirus (SARS-CoV-2) has spread rapidly around the world. In order to prevent the spread of infection, city blockades and immigration restrictions have been introduced in each country, but these measures have a severe serious impact on the economy. This paper examines the possibility of both harvesting vibration energy and detecting mass by using a magnetostrictive alloy. Few efforts have been made to develop new magnetostrictive biosensor materials. Therefore, we propose magnetostrictive Fe-Co/Ni clad steel vibration energy harvesters with mass detection, and we numerically and experimentally discuss the effect of the proof mass weight on the frequency shift and output voltage induced by bending vibration. The results reveal that the frequency and output voltage decrease significantly as the mass increases, indicating that the energy harvesting device is capable of mass detection. In the future, device miniaturization and the possibility of virus detection will be considered.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...