1.
Med Phys ; 51(3): 2119-2127, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37727132

RESUMEN

BACKGROUND: The concept of volumetric modulated arc therapy-computed tomography (VMAT-CT) was proposed more than a decade ago. However, its application has been very limited mainly due to the poor image quality. More specifically, the blurred areas in electronic portal imaging device (EPID) images collected during VMAT heavily degrade the image quality of VMAT-CT. PURPOSE: The goal of this study was to propose systematic methods to preprocess EPID images and improve the image quality of VMAT-CT. METHODS: Online region-based active contour method was introduced to binarize portal images. Multi-leaf collimator (MLC) motion modeling was developed to remove the MLC motion blur. Outlier filtering was then applied to replace the remaining artifacts with plausible data. To assess the impact of these preprocessing methods on the image quality of VMAT-CT, 44 clinical VMAT plans for several treatment sites (lung, esophagus, and head & neck) were delivered to a Rando phantom, and several real-patient cases were also acquired. VMAT-CT reconstruction was attempted for all the cases, and image quality was evaluated. RESULTS: All three preprocessing methods could effectively remove the blurred edges of EPID images. The combined preprocessing methods not only saved VMAT-CT from distortions and artifacts, but also increased the percentage of VMAT plans that can be reconstructed. CONCLUSIONS: The systematic preprocessing of portal images improves the image quality of VMAT-CT significantly, and facilitates the application of VMAT-CT as an effective image guidance tool.


Asunto(s)
Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X , Pulmón
2.
J Mass Spectrom ; 51(12): 1180-1186, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27677117

RESUMEN

Electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mainly generate protonated ions from peptides and proteins but sodiated (or potassiated) ions from carbohydrates. The ion intensities of sodiated (or potassiated) carbohydrates generated by ESI and MALDI are generally lower than those of protonated peptides and proteins. Ab initio calculations and transition state theory were used to investigate the reasons for the low detection sensitivity for underivatized carbohydrates. We used glucose and cellobiose as examples and showed that the low detection sensitivity is partly attributable to the following factors. First, glucose exhibits a low proton affinity. Most protons generated by ESI or MALDI attach to water clusters and matrix molecules. Second, protonated glucose and cellobiose can easily undergo dehydration reactions. Third, the sodiation affinities of glucose and cellobiose are small. Some sodiated glucose and cellobiose dissociate into the sodium cations and neutral carbohydrates during ESI or MALDI process. The increase of detection sensitivity of carbohydrates in mass spectrometry by various methods can be rationalized according to these factors. Copyright © 2016 John Wiley & Sons, Ltd.


Asunto(s)
Carbohidratos/análisis , Carbohidratos/química , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Cationes , Límite de Detección