Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
PDA J Pharm Sci Technol ; 73(3): 235-246, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30651335

RESUMEN

Sensitivity of drugs to one or more elements of the primary packaging is a serious concern for the pharmaceutical industry. Biologics in particular are highly sensitive, leading to a higher risk of incompatibility and stability test failure as worst-case scenario.This potential incompatibility-and the consequent formulation instability due to the interactions between the drug and the primary container surface-may have multiple causes: the intrinsic nature of the container surface, leachables coming from the materials used, substances coming from the production process, or silicone oil droplets or other particles.The Alba primary packaging platform was designed to have the same interface between the drug and the glass container surface on the different primary packaging containers in order to minimize the emergence of instabilities at later stages of formulation development. Alba containers are internally treated with an innovative cross-linked coating based on silicone oil lubricant, and the additional rubber components have been selected to minimize the possible differences between the container typologies.This paper shows in great detail the reduction of the inorganic extractables released and the comparability of the performances of the different containers obtained using Alba technology.The improvement has been demonstrated by stressing the containers with different extract solutions; Alba-coated containers show a strong reduction of inorganic extractables and of corrosion degree compared to spray-on siliconized and bulk products. The containers included in the Alba platform present comparable results, and this represents a strong advantage during the drug formulation development by facilitating the transition from one container to another.LAY ABSTRACT: The sensitivity of drugs to one or more elements of the primary packaging is a serious concern for the pharmaceutical industry. Biologics in particular are highly sensitive, leading to a higher risk of incompatibility and stability test failure worst-case scenario.This potential incompatibility-and the consequent formulation instability due to the interactions between the drug and the primary container surface-may have multiple causes: the intrinsic nature of the container surface, leachables coming from the materials used, substances coming from the production process, or silicone oil droplets or other particles.The Alba primary packaging platform was designed to minimize these problems associated with the interaction between the drug and its primary packaging. This paper shows in great detail and with robust data the inorganic extractables release reduction and the delamination risk mitigation obtained using the Alba technology.


Asunto(s)
Contaminación de Medicamentos/prevención & control , Embalaje de Medicamentos/normas , Preparaciones Farmacéuticas/normas , Óxido de Aluminio/análisis , Compuestos de Boro/análisis , Vidrio/química , Vidrio/normas , Infusiones Parenterales , Óxidos/análisis , Preparaciones Farmacéuticas/administración & dosificación , Plásticos/química , Plásticos/normas , Dióxido de Silicio/análisis , Compuestos de Sodio/análisis , Propiedades de Superficie , Jeringas
2.
PDA J Pharm Sci Technol ; 72(4): 382-392, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29853611

RESUMEN

The sensitivity of drugs to one or more elements of the primary packaging is a serious concern for the pharmaceutical industry. Biologics in particular are highly sensitive, leading to a higher risk of incompatibility and stability test failures as worst-case scenarios. This potential incompatibility-and the consequent formulation instability due to the interactions between the drug and the primary container surface-may have multiple causes: the intrinsic nature of the container surface, leachables coming from the materials used, substances coming from the production process, silicone oil droplets, or other particles. The Alba primary packaging platform was designed in order to have the same interface between the drug and the glass container surface on the different primary packaging containers to minimize the emergence of instabilities at later stages during the formulation development. The Alba containers are internally treated with an innovative cross-linked coating based on silicone oil lubricant, and the additional rubber components have been selected to minimize the possible differences between the container typologies. This paper shows in deep detail the subvisible particle release reduction and the comparability of the performances of different containers, obtained using such technology. To demonstrate this improvement, different analytical methods for particle measurement were used on bulk containers, Alba-treated ones and containers from a standard production (spray-on siliconization). Considering that Alba containers are conform to the standard compendial testing and the amount of particles released from Alba-coated syringes was comparable to the bulk syringes for the first two mildly stressful methods, it was decided to develop and apply a more challenging method, such as an autoclave treatment for 1 h at 121°C, to better highlight the performances of this innovative technology. The data obtained, under the most stressful conditions, show a substantial reduction in the released particle concentrations compared to a spray-on siliconized container, with comparable performances for all the containers included in the Alba platform. The latter could heavily reduce drug formulation development timing, facilitating the transition from one container to another.LAY ABSTRACT: The sensitivity of drugs to one or more elements of the primary packaging is a serious concern for the pharmaceutical industry. Biologics in particular are highly sensitive, leading to a higher risk of incompatibility and stability test failures as worst-case scenarios. This potential incompatibility-and the consequent formulation instability due to the interactions between the drug and the primary container surface-may have multiple causes: the intrinsic nature of the container surface, leachables coming from the materials used, or substances coming from the production process, silicone oil droplets, or other particles. The Alba primary packaging platform was designed to solve these problems associated with the interaction between the drug and its primary packaging. This paper shows in deep detail and with robust data the subvisible particle release reduction obtained using such technology.


Asunto(s)
Productos Biológicos/química , Química Farmacéutica/métodos , Embalaje de Medicamentos , Tecnología Farmacéutica/métodos , Industria Farmacéutica/métodos , Vidrio/química , Aceites de Silicona/química , Siliconas/química , Jeringas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA