Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur J Appl Physiol ; 123(10): 2157-2165, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37221340

RESUMEN

PURPOSE: Exercise is a critical element for the management of body weight and improvement of quality of life of individuals with obesity. Due to its convenience and accessibility, running is a commonly used exercise modality to meet exercise guidelines. However, the weight-bearing component during high impacts of this exercise modality might limit the participation in exercise and reduce the effectiveness of running-based exercise interventions in individuals with obesity. The hip flexion feedback system (HFFS) assists participants in meeting specific exercise intensities by giving the participant specific increased hip flexion targets while walking on a treadmill. The resulting activity involves walking with increased hip flexion which removes the high impacts of running. The purpose of this study was to compare physiological and biomechanical parameters during an HFFS session and an independent treadmill walking/running session (IND). METHODS: Heart rate, oxygen consumption (VO2), heart rate error, and tibia peak positive accelerations (PPA) were investigated for each condition at 40% and 60% of heart rate reserve exercise intensities. RESULTS: VO2 was higher for IND despite no differences in heart rate. Tibia PPAs were reduced during the HFFS session. Heart rate error was reduced for HFFS during non-steady state exercise. CONCLUSION: While demanding lower energy consumption compared to running, HFFS exercise results in lower tibia PPAs and more accurate monitoring of exercise intensity. HFFS might be a valid exercise alternative for individuals with obesity or individuals that require low-impact forces at the lower limbs.


Asunto(s)
Marcha , Calidad de Vida , Humanos , Marcha/fisiología , Ejercicio Físico/fisiología , Caminata/fisiología , Obesidad/terapia , Prueba de Esfuerzo , Consumo de Oxígeno/fisiología
2.
Obes Sci Pract ; 9(2): 103-111, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37034570

RESUMEN

Objective: Body volumes (BV) are used for calculating body composition to perform obesity assessments. Conventional BV estimation techniques, such as underwater weighing, can be difficult to apply. Advanced machine learning techniques enable multiple obesity-related body measurements to be obtained using a single-camera image; however, the accuracy of BV calculated using these techniques is unknown. This study aims to adapt and evaluate a machine learning technique, synthetic training for real accurate pose and shape (STRAPS), to estimate BV. Methods: The machine learning technique, STRAPS, was applied to generate three-dimensional (3D) models from simulated two-dimensional (2D) images; these 3D models were then scaled with body stature and BV were estimated using regression models corrected for body mass. A commercial 3D scan dataset with a wide range of participants (n = 4318) was used to compare reference and estimated BV data. Results: The developed methods estimated BV with small relative standard errors of estimation (<7%) although performance varied when applied to different groups. The BV estimated for people with body mass index (BMI) < 30 kg/m2 (1.9% for males and 1.8% for females) were more accurate than for people with BMI ≥ 30 kg/m2 (6.9% for males and 2.4% for females). Conclusions: The developed method can be used for females and males with BMI < 30 kg/m2 in BV estimation and could be used for obesity assessments at home or clinic settings.

3.
Eur J Sport Sci ; 22(8): 1204-1210, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33944686

RESUMEN

Somatotype is an approach to quantify body physique (shape and body composition). Somatotyping by manual measurement (the anthropometric method) or visual rating (the photoscopic method) needs technical expertize to minimize intra- and inter-observer errors. This study aims to develop machine learning models which enable automatic estimation of Heath-Carter somatotypes using a single-camera 3D scanning system. Single-camera 3D scanning was used to obtain 3D imaging data and computer vision techniques to extract features of body shape. Machine learning models were developed to predict participants' somatotypes from the extracted shape features. These predicted somatotypes were compared against manual measurement procedures. Data were collected from 46 participants and used as the training/validation set for model developing, whilst data collected from 17 participants were used as the test set for model evaluation. Evaluation tests showed that the 3D scanning methods enable accurate (mean error < 0.5; intraclass correlation coefficients >0.8) and precise (test-retest root mean square error < 0.5; intraclass correlation coefficients >0.8) somatotype predictions. This study shows that the 3D scanning methods could be used as an alternative to traditional somatotyping approaches after the current models improve with the large datasets.


Asunto(s)
Composición Corporal , Somatotipos , Antropometría/métodos , Humanos , Imagenología Tridimensional
4.
Sci Rep ; 10(1): 12125, 2020 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-32699270

RESUMEN

Manual anthropometrics are used extensively in medical practice and epidemiological studies to assess an individual's health. However, traditional techniques reduce the complicated shape of human bodies to a series of simple size measurements and derived health indices, such as the body mass index (BMI), the waist-hip-ratio (WHR) and waist-by-height0.5 ratio (WHT.5R). Three-dimensional (3D) imaging systems capture detailed and accurate measures of external human form and have the potential to surpass traditional measures in health applications. The aim of this study was to investigate how shape measurement can complement existing anthropometric techniques in the assessment of human form. Geometric morphometric methods and principal components analysis were used to extract independent, scale-invariant features of torso shape from 3D scans of 43 male participants. Linear regression analyses were conducted to determine whether novel shape measures can complement anthropometric indices when estimating waist skinfold thickness measures. Anthropometric indices currently used in practice explained up to 52.2% of variance in waist skinfold thickness, while a combined regression model using WHT.5R and shape measures explained 76.5% of variation. Measures of body shape provide additional information regarding external human form and can complement traditional measures currently used in anthropometric practice to estimate central adiposity.

5.
Proc Inst Mech Eng H ; 233(9): 938-947, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31250706

RESUMEN

KinectFusion is a typical three-dimensional reconstruction technique which enables generation of individual three-dimensional human models from consumer depth cameras for understanding body shapes. The aim of this study was to compare three-dimensional reconstruction results obtained using KinectFusion from data collected with two different types of depth camera (time-of-flight and stereoscopic cameras) and compare these results with those of a commercial three-dimensional scanning system to determine which type of depth camera gives improved reconstruction. Torso mannequins and machined aluminium cylinders were used as the test objects for this study. Two depth cameras, Microsoft Kinect V2 and Intel Realsense D435, were selected as the representatives of time-of-flight and stereoscopic cameras, respectively, to capture scan data for the reconstruction of three-dimensional point clouds by KinectFusion techniques. The results showed that both time-of-flight and stereoscopic cameras, using the developed rotating camera rig, provided repeatable body scanning data with minimal operator-induced error. However, the time-of-flight camera generated more accurate three-dimensional point clouds than the stereoscopic sensor. Thus, this suggests that applications requiring the generation of accurate three-dimensional human models by KinectFusion techniques should consider using a time-of-flight camera, such as the Microsoft Kinect V2, as the image capturing sensor.


Asunto(s)
Imagenología Tridimensional/métodos , Tamaño Corporal , Humanos , Modelos Anatómicos , Programas Informáticos , Factores de Tiempo
6.
Comput Biol Med ; 101: 112-119, 2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-30125785

RESUMEN

Whole-body volumes and segmental volumes are highly related to the health and medical condition of individuals. However, the traditional manual post-processing of raw 3D scanned data is time-consuming and needs technical expertise. The purpose of this study was to develop bespoke software for obtaining whole-body volumes and segmental volumes from raw 3D scanned data automatically and to establish its accuracy and reliability. The bespoke software applied Stitched Puppet model fitting techniques to deform template models to fit the 3D raw scanned data to identify the segmental endpoints and determine their locations. Finally, the bespoke software used the location information of segmental endpoints to set segmental boundaries on the reconstructed meshes and to calculate body volume. The whole-body volumes and segmental volumes (head & neck, torso, arms, and legs) of 29 participants processed by the traditional manual operation were regarded as the references and compared to the measurements obtained with the bespoke software using the intra-method and inter-method relative technical errors of measurement. The results showed that the errors in whole-body volumes and most segmental volumes acquired from the bespoke software were less than 5%. Overall, the bespoke software developed in this study can complete the post-processing tasks without any technical expertise, and the obtained whole-body volumes and segmental volumes can achieve good accuracy for some applications in health and medicine.


Asunto(s)
Algoritmos , Pesos y Medidas Corporales/métodos , Imagenología Tridimensional/métodos , Programas Informáticos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad
7.
Ergonomics ; 59(12): 1673-1678, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27004589

RESUMEN

Three-dimensional (3D) photonic scanning is an emerging technique to acquire accurate body segment parameter data. This study established the repeated reliability of segmental centres of mass when using 3D photonic scanning (3DPS). Seventeen male participants were scanned twice by a 3D whole-body laser scanner. The same operators conducted the reconstruction and segmentation processes to obtain segmental meshes for calculating the segmental centres of mass. The segmental centres of mass obtained from repeated 3DPS were compared by relative technical error of measurement (TEM). Hypothesis tests were conducted to determine the size of change required for each segment to be determined a true variation. The relative TEMs for all segments were less than 5%. The relative changes in centres of mass at ±1.5% for most segments can be detected (p < 0.05). The arm segments which are difficult to keep in the same scanning pose generated more error than other segments. Practitioner Summary: Three-dimensional photonic scanning is an emerging technique to acquire body segment parameter data. This study established the repeated reliability of segmental centres of mass when using 3D photonic scanning and emphasised that the error for arm segments need to be considered while using this technique to acquire centres of mass.


Asunto(s)
Antropometría/métodos , Imagenología Tridimensional/métodos , Adulto , Fenómenos Biomecánicos , Humanos , Rayos Láser , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
8.
J Sports Sci Med ; 14(1): 215-24, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25729310

RESUMEN

Due to the difficulty of measuring forces and torques acting on a swimmer during mid-pool swimming, an inverse dynamics approach is required. Personalised body segment parameter (BSP) data enabling calculation of net forces and torques can be obtained using the elliptical zone method. The purpose of this study was to establish the reliability of estimating BSP data of swimmers by the elliptical zone method with segment outlines being traced manually on a personal computer screen. Five assessors digitised the segment landmarks and traced the body segments from front and side view digital photographs of 11 single arm amputee swimmers. Each swimmer was assessed five times by each of the five assessors. The order was fully randomised. Within assessor variability was less than 5% for the segment centre of mass position of all segments, for segment length except the neck (5.2%), and for segment mass except neck (11.9%), hands (Left: 8.1%; Right: 5.8%) and feet (Left: 7.3%; Right: 7.3%). Analysis of mean variability within and between assessors indicated that between assessor variability was generally as large or larger than within assessor variability. Consequently it is recommended that when seeking personalised BSP data to maximise the accuracy of derived kinetics and sensitivity for longitudinal and bilateral within-subject comparisons the individual should be assessed by the same assessor with mean values obtained from five repeat digitisations. This study established that using the elliptical zone method using E-Zone software is a reliable and convenient way of obtaining personalised BSP data for use in analysis of swimming. Key pointsA unique (not been attempted previously) study of reliability of calculating personalised Body Segment Parameter (BSP) data using the elliptical zone methodEstablishes benchmark data regarding the reliability of BSP data for comparison with emerging technologies for obtaining personalised BSP data non-invasively.Provides a description and guidelines for good practice for maximising the accuracy of derived kinematics and kinetics in swimming.The method of body modelling described can also be applied to studies in other sports and in assessing change in health status related to body shape characteristics for sport and non-sport populations.

9.
J Sports Sci ; 33(16): 1675-81, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25599265

RESUMEN

The purpose of this study was to determine the kinematic patterns that maximized the vertical force produced during the water polo eggbeater kick. Twelve water polo players were tested executing the eggbeater kick with the trunk aligned vertically and with the upper limbs above water while trying to maintain as high a position as possible out of the water for nine eggbeater kick cycles. Lower limb joint angular kinematics, pitch angles and speed of the feet were calculated. The vertical force produced during the eggbeater kick cycle was calculated using inverse dynamics for the independent lower body segments and combined upper body segments, and a participant-specific second-degree regression equation for the weight and buoyancy contributions. Vertical force normalized to body weight was associated with hip flexion (average, r = 0.691; maximum, r = 0.791; range of motion, r = 0.710), hip abduction (maximum, r = 0.654), knee flexion (average, r = 0.716; minimum, r = 0.653) and knee flexion-extension angular velocity (r = 0.758). Effective orientation of the hips resulted in fast horizontal motion of the feet with positive pitch angles. Vertical motion of the feet was negatively associated with vertical force. A multiple regression model comprising the non-collinear variables of maximum hip abduction, hip flexion range of motion and knee flexion angular velocity accounted for 81% of the variance in normalized vertical force. For high performance in the water polo, eggbeater kick players should execute fast horizontal motion with the feet by having large abduction and flexion of the hips, and fast extension and flexion of the knees.


Asunto(s)
Extremidad Inferior/fisiología , Deportes/fisiología , Fenómenos Biomecánicos , Pie/fisiología , Cadera/fisiología , Humanos , Rodilla/fisiología , Masculino , Rango del Movimiento Articular , Natación/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA