Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Opt Express ; 31(21): 33787-33798, 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37859151

RESUMEN

Excess micromotion is detrimental to accurate qubit control of trapped ions, thus measuring and minimizing it is crucial. In this paper, we present a simple approach for measuring and suppressing excess micromotion of trapped ions by leveraging the existing laser-driven qubit transition scheme combined with direct scanning of dc voltages. The compensation voltage is deduced by analyzing the Bessel expansion of a scanned qubit transition rate. The method provides a fair level of sensitivity for practical quantum computing applications, while demanding minimal deviation of trap condition. By accomplishing compensation of excess micromotion in the qubit momentum-excitation direction, the scheme offers an additional avenue for excess micromotion compensation, complementing existing compensation schemes.

2.
Bioinspir Biomim ; 18(1)2022 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-36270321

RESUMEN

This paper presents a three-axis biomimetic gyroscope, mimicking the haltere of Diptera. Diptera use a club-shaped mechanosensory organ called the haltere to get the three-axis angular velocity information, namely roll, pitch and yaw axes, for flight control. One pair of halteres is physically connected to the wings of Diptera that vibrate in antiphase to the flapping wings in ambient air. They sense the Coriolis force and relay angular velocity information to the Diptera. As an alternative to the conventional micro-electro-mechanical system gyroscopes which are widely used in robotics, many research groups have attempted to mimic the haltere. However, no previous study succeeded in measuring all three-axis components of angular velocity, due to various shortcomings. In this paper, we developed the first three-axis haltere-mimicking gyroscope. Two perpendicularly positioned haltere-mimicking structures that can vibrate at a 180° amplitude were mechanically integrated into a robot actuator. Two accelerometers, placed at the tip of each structure, were employed to measure the Coriolis force. The performance of the novel biomimetic gyroscope was measured in all rotational directions, using a motion capture system as the ground truth. One-axis input experiments were performed 240 times at different input magnitudes and directions, and the measured orientation error was less than ±2.0% in all experiments. In 80 three-axis input experiments, the orientation error was less than ±3.5%.


Asunto(s)
Dípteros , Animales , Movimiento (Física)
3.
Sensors (Basel) ; 21(4)2021 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-33562053

RESUMEN

A new method is proposed to measure unknown amplitudes of radio frequency (RF) voltages applied to ion traps, using a pre-calibrated voltage divider with RF shielding. In contrast to previous approaches that estimate the applied voltage by comparing the measured secular frequencies with a numerical simulation, we propose using a pre-calibrated voltage divider to determine the absolute amplitude of large RF voltages amplified by a helical resonator. The proposed method does not require measurement of secular frequencies and completely removes uncertainty caused by limitations of numerical simulations. To experimentally demonstrate our method, we first obtained a functional relation between measured secular frequencies and large amplitudes of RF voltages using the calibrated voltage divider. A comparison of measured relations and simulation results without any fitting parameters confirmed the validity of the proposed method. Our method can be applied to most ion trap experiments. In particular, it will be an essential tool for surface ion traps which are extremely vulnerable to unknown large RF voltages and for improving the accuracy of numerical simulations for ion trap experiments.

4.
Opt Express ; 28(26): 39727-39738, 2020 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-33379516

RESUMEN

We present a compact optical design for a scalable trapped ion quantum processor employing a single high numerical aperture lens for the excitation of ions and collection of photons, both of which are essential for remote entanglement generation. We verified the design by performing a quantum interference experiment between two photons generated by two sets of the proposed design and observed a 82(3) % suppression of coincidence within 8.13 ns time window when the two photons became indistinguishable. This design can be extended for the simultaneous generation of multiple pairs of entangled qubits with existing fiber-array devices.

5.
Micromachines (Basel) ; 9(12)2018 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-30572645

RESUMEN

Over the past decade, synthesized nanomaterials, such as carbon nanotube, nanoparticle, quantum dot, and nanowire, have already made breakthroughs in various fields, including biomedical sensors. Enormous surface area-to-volume ratio of the nanomaterials increases sensitivity dramatically compared with macro-sized material. Herein we present a comprehensive review about the working principle and fabrication process of nanowire sensor. Moreover, its applications for the detection of biomarker, virus, and DNA, as well as for drug discovery, are reviewed. Recent advances including self-powering, reusability, sensitivity in high ionic strength solvent, and long-term stability are surveyed and highlighted as well. Nanowire is expected to lead significant improvement of biomedical sensor in the near future.

6.
Sensors (Basel) ; 18(10)2018 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-30275417

RESUMEN

Silicon nanowires (SiNWs) have received attention in recent years due to their anomalous piezoresistive (PZR) effects. Although the PZR effects of SiNWs have been extensively researched, they are still not fully understood. Herein, we develop a new model of the PZR effects of SiNWs to characterize the PZR effects. First, the resistance of SiNW is modeled based on the surface charge density. The characteristics of SiNW, such as surface charge and effective conducting area, can be estimated by using this resistance model. Then, PZR effects are modeled based on stress concentration and piezopinch effects. Stress concentration as a function of the physical geometry of SiNWs can amplify PZR effects by an order of magnitude. The piezopinch effects can also result in increased PZR effects that are at least two times greater than that of bulk silicon. Experimental results show that the proposed model can predict the PZR effects of SiNWs accurately.

7.
Sensors (Basel) ; 18(7)2018 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-29932163

RESUMEN

In nature, arthropods have evolved to utilize a multiaperture vision system with a micro-optical structure which has advantages, such as compact size and wide-angle view, compared to that of a single-aperture vision system. In this paper, we present a multiaperture imaging system using a microlens array fabricated by a patterned-layer integrating soft lithography (PLISL) process which is based on a molding technique that can transfer three-dimensional structures and a gold screening layer simultaneously. The imaging system consists of a microlens array, a lens-adjusting jig, and a conventional (charge-coupled device) CCD image sensor. The microlens array has a light screening layer patterned among all the microlenses by the PLISL process to prevent light interference. The three-dimensionally printed jig adjusts the microlens array on the conventional CCD sensor for the focused image. The manufactured imaging system has a thin optic system and a large field-of-view of 100 degrees. The developed imaging system takes multiple images at once. To show its possible applications, multiple depth plane images were reconstructed based on the taken subimages with a single shot.

8.
Sensors (Basel) ; 18(1)2018 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-29320414

RESUMEN

In this paper, a new localization system utilizing afocal optical flow sensor (AOFS) based sensor fusion for indoor service robots in low luminance and slippery environment is proposed, where conventional localization systems do not perform well. To accurately estimate the moving distance of a robot in a slippery environment, the robot was equipped with an AOFS along with two conventional wheel encoders. To estimate the orientation of the robot, we adopted a forward-viewing mono-camera and a gyroscope. In a very low luminance environment, it is hard to conduct conventional feature extraction and matching for localization. Instead, the interior space structure from an image and robot orientation was assessed. To enhance the appearance of image boundary, rolling guidance filter was applied after the histogram equalization. The proposed system was developed to be operable on a low-cost processor and implemented on a consumer robot. Experiments were conducted in low illumination condition of 0.1 lx and carpeted environment. The robot moved for 20 times in a 1.5 × 2.0 m square trajectory. When only wheel encoders and a gyroscope were used for robot localization, the maximum position error was 10.3 m and the maximum orientation error was 15.4°. Using the proposed system, the maximum position error and orientation error were found as 0.8 m and within 1.0°, respectively.

9.
J Vis Exp ; (126)2017 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-28872137

RESUMEN

Ions trapped in a quadrupole Paul trap have been considered one of the strong physical candidates to implement quantum information processing. This is due to their long coherence time and their capability to manipulate and detect individual quantum bits (qubits). In more recent years, microfabricated surface ion traps have received more attention for large-scale integrated qubit platforms. This paper presents a microfabrication methodology for ion traps using micro-electro-mechanical system (MEMS) technology, including the fabrication method for a 14 µm-thick dielectric layer and metal overhang structures atop the dielectric layer. In addition, an experimental procedure for trapping ytterbium (Yb) ions of isotope 174 (174Yb+) using 369.5 nm, 399 nm, and 935 nm diode lasers is described. These methodologies and procedures involve many scientific and engineering disciplines, and this paper first presents the detailed experimental procedures. The methods discussed in this paper can easily be extended to the trapping of Yb ions of isotope 171 (171Yb+) and to the manipulation of qubits.


Asunto(s)
Iones/química , Microtecnología/métodos
10.
Korean J Physiol Pharmacol ; 21(5): 555-563, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28883759

RESUMEN

Electrical stimulation through retinal prosthesis elicits both short and long-latency retinal ganglion cell (RGC) spikes. Because the short-latency RGC spike is usually obscured by electrical stimulus artifact, it is very important to isolate spike from stimulus artifact. Previously, we showed that topographic prominence (TP) discriminator based algorithm is valid and useful for artifact subtraction. In this study, we compared the performance of forward backward (FB) filter only vs. TP-adopted FB filter for artifact subtraction. From the extracted retinae of rd1 mice, we recorded RGC spikes with 8×8 multielectrode array (MEA). The recorded signals were classified into four groups by distances between the stimulation and recording electrodes on MEA (200-400, 400-600, 600-800, 800-1000 µm). Fifty cathodic phase-1st biphasic current pulses (duration 500 µs, intensity 5, 10, 20, 30, 40, 50, 60 µA) were applied at every 1 sec. We compared false positive error and false negative error in FB filter and TP-adopted FB filter. By implementing TP-adopted FB filter, short-latency spike can be detected better regarding sensitivity and specificity for detecting spikes regardless of the strength of stimulus and the distance between stimulus and recording electrodes.

11.
J Neural Eng ; 14(1): 016017, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-28045002

RESUMEN

OBJECTIVE: Direct stimulation of retinal ganglion cells in degenerate retinas by implanting epi-retinal prostheses is a recognized strategy for restoration of visual perception in patients with retinitis pigmentosa or age-related macular degeneration. Elucidating the best stimulus-response paradigms in the laboratory using multielectrode arrays (MEA) is complicated by the fact that the short-latency spikes (within 10 ms) elicited by direct retinal ganglion cell (RGC) stimulation are obscured by the stimulus artifact which is generated by the electrical stimulator. APPROACH: We developed an artifact subtraction algorithm based on topographic prominence discrimination, wherein the duration of prominences within the stimulus artifact is used as a strategy for identifying the artifact for subtraction and clarifying the obfuscated spikes which are then quantified using standard thresholding. MAIN RESULTS: We found that the prominence discrimination based filters perform creditably in simulation conditions by successfully isolating randomly inserted spikes in the presence of simple and even complex residual artifacts. We also show that the algorithm successfully isolated short-latency spikes in an MEA-based recording from degenerate mouse retinas, where the amplitude and frequency characteristics of the stimulus artifact vary according to the distance of the recording electrode from the stimulating electrode. By ROC analysis of false positive and false negative first spike detection rates in a dataset of one hundred and eight RGCs from four retinal patches, we found that the performance of our algorithm is comparable to that of a generally-used artifact subtraction filter algorithm which uses a strategy of local polynomial approximation (SALPA). SIGNIFICANCE: We conclude that the application of topographic prominence discrimination is a valid and useful method for subtraction of stimulation artifacts with variable amplitudes and shapes. We propose that our algorithm may be used as stand-alone or supplementary to other artifact subtraction algorithms like SALPA.


Asunto(s)
Potenciales de Acción/fisiología , Algoritmos , Artefactos , Estimulación Eléctrica/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Tiempo de Reacción/fisiología , Células Ganglionares de la Retina/fisiología , Animales , Análisis Discriminante , Ratones , Ratones Endogámicos C3H , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Análisis Espacio-Temporal
12.
Sensors (Basel) ; 16(12)2016 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-27916963

RESUMEN

This paper proposes a neural stimulation device integrated with a silicon nanowire (SiNW)-based photodetection circuit for the activation of neurons with light. The proposed device is comprised of a voltage divider and a current driver in which SiNWs are used as photodetector and field-effect transistors; it has the functions of detecting light, generating a stimulation signal in proportion to the light intensity, and transmitting the signal to a micro electrode. To show the applicability of the proposed neural stimulation device as a high-resolution retinal prosthesis system, a high-density neural stimulation device with a unit cell size of 110 × 110 µ m and a resolution of 32 × 32 was fabricated on a flexible film with a thickness of approximately 50 µm. Its effectiveness as a retinal stimulation device was then evaluated using a unit cell in an in vitro animal experiment involving the retinal tissue of retinal Degeneration 1 (rd1) mice. Experiments wherein stimulation pulses were applied to the retinal tissues successfully demonstrate that the number of spikes in neural response signals increases in proportion to light intensity.


Asunto(s)
Nanocables/química , Silicio/química , Animales , Electrodos , Ratones , Nanotecnología/métodos , Neuronas/fisiología , Retina/fisiología , Degeneración Retiniana/terapia , Transistores Electrónicos , Prótesis Visuales
13.
Sensors (Basel) ; 16(5)2016 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-27136559

RESUMEN

Ion traps can provide both physical implementation of quantum information processing and direct observation of quantum systems. Recently, surface ion traps have been developed using microfabrication technologies and are considered to be a promising platform for scalable quantum devices. This paper presents detailed guidelines for designing the electrodes of surface ion traps. First, we define and explain the key specifications including trap depth, q-parameter, secular frequency, and ion height. Then, we present a numerical-simulation-based design procedure, which involves determining the basic assumptions, determining the shape and size of the chip, designing the dimensions of the radio frequency (RF) electrode, and analyzing the direct current (DC) control voltages. As an example of this design procedure, we present a case study with tutorial-like explanations. The proposed design procedure can provide a practical guideline for designing the electrodes of surface ion traps.

14.
Sensors (Basel) ; 16(3)2016 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-26938540

RESUMEN

This paper presents a monocular vision sensor-based obstacle detection algorithm for autonomous robots. Each individual image pixel at the bottom region of interest is labeled as belonging either to an obstacle or the floor. While conventional methods depend on point tracking for geometric cues for obstacle detection, the proposed algorithm uses the inverse perspective mapping (IPM) method. This method is much more advantageous when the camera is not high off the floor, which makes point tracking near the floor difficult. Markov random field-based obstacle segmentation is then performed using the IPM results and a floor appearance model. Next, the shortest distance between the robot and the obstacle is calculated. The algorithm is tested by applying it to 70 datasets, 20 of which include nonobstacle images where considerable changes in floor appearance occur. The obstacle segmentation accuracies and the distance estimation error are quantitatively analyzed. For obstacle datasets, the segmentation precision and the average distance estimation error of the proposed method are 81.4% and 1.6 cm, respectively, whereas those for a conventional method are 57.5% and 9.9 cm, respectively. For nonobstacle datasets, the proposed method gives 0.0% false positive rates, while the conventional method gives 17.6%.

15.
Sensors (Basel) ; 15(10): 26009-17, 2015 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-26473877

RESUMEN

Capacitive sensing schemes are widely used for various microsensors; however, such microsensors suffer from severe parasitic capacitance problems. This paper presents a fully integrated low-noise readout circuit with automatic offset cancellation loop (AOCL) for capacitive microsensors. The output offsets of the capacitive sensing chain due to the parasitic capacitances and process variations are automatically removed using AOCL. The AOCL generates electrically equivalent offset capacitance and enables charge-domain fine calibration using a 10-bit R-2R digital-to-analog converter, charge-transfer switches, and a charge-storing capacitor. The AOCL cancels the unwanted offset by binary-search algorithm based on 10-bit successive approximation register (SAR) logic. The chip is implemented using 0.18 µm complementary metal-oxide-semiconductor (CMOS) process with an active area of 1.76 mm². The power consumption is 220 µW with 3.3 V supply. The input parasitic capacitances within the range of -250 fF to 250 fF can be cancelled out automatically, and the required calibration time is lower than 10 ms.

16.
Biomed Mater Eng ; 26 Suppl 1: S935-41, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26406095

RESUMEN

This paper presents an analog front-end (AFE) IC design for recording biopotential signals. The AFE employs a capacitively coupled instrumentation amplifier to achieve a low-noise and high-common mode rejection ratio (CMRR) system. A ripple reduction loop is proposed to reduce the ripple generated by the up-modulating chopper. The low frequency noise is attenuated by an input AC coupling capacitor, and is attenuated again by a DC servo loop. The proposed AFE features a differential gain of 71 dB, and a CMRR of 89 dB, at 50 Hz. Furthermore, the proposed AFE can robustly acquire biopotential signals even in the presence of an input offset and ripples.


Asunto(s)
Electrocardiografía/instrumentación , Algoritmos , Amplificadores Electrónicos , Electrocardiografía/métodos , Fenómenos Electrofisiológicos , Diseño de Equipo , Humanos
17.
Sensors (Basel) ; 15(6): 14345-55, 2015 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-26091397

RESUMEN

In order to provide high-quality visual information to patients who have implanted retinal prosthetic devices, the number of microelectrodes should be large. As the number of microelectrodes is increased, the dimensions of each microelectrode must be decreased, which in turn results in an increased microelectrode interface impedance and decreased injection current dynamic range. In order to improve the trade-off envelope between the number of microelectrodes and the current injection characteristics, a 3D microelectrode structure can be used as an alternative. In this paper, the electrical characteristics of 2D and 3D Au microelectrodes were investigated. In order to examine the effects of the structural difference, 2D and 3D Au microelectrodes with different base areas but similar effective surface areas were fabricated and evaluated. Interface impedances were measured and similar dynamic ranges were obtained for both 2D and 3D Au microelectrodes. These results indicate that more electrodes can be implemented in the same area if 3D designs are used. Furthermore, the 3D Au microelectrodes showed substantially enhanced electrical durability characteristics against over-injected stimulation currents, withstanding electrical currents that are much larger than the limit measured for 2D microelectrodes of similar area. This enhanced electrical durability property of 3D Au microelectrodes is a new finding in microelectrode research, and makes 3D microelectrodes very desirable devices.


Asunto(s)
Oro/química , Microtecnología/instrumentación , Prótesis Visuales , Impedancia Eléctrica , Microelectrodos , Diseño de Prótesis
18.
Sensors (Basel) ; 15(5): 11208-21, 2015 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-25985164

RESUMEN

This paper introduces a novel afocal optical flow sensor (OFS) system for odometry estimation in indoor robotic navigation. The OFS used in computer optical mouse has been adopted for mobile robots because it is not affected by wheel slippage. Vertical height variance is thought to be a dominant factor in systematic error when estimating moving distances in mobile robots driving on uneven surfaces. We propose an approach to mitigate this error by using an afocal (infinite effective focal length) system. We conducted experiments in a linear guide on carpet and three other materials with varying sensor heights from 30 to 50 mm and a moving distance of 80 cm. The same experiments were repeated 10 times. For the proposed afocal OFS module, a 1 mm change in sensor height induces a 0.1% systematic error; for comparison, the error for a conventional fixed-focal-length OFS module is 14.7%. Finally, the proposed afocal OFS module was installed on a mobile robot and tested 10 times on a carpet for distances of 1 m. The average distance estimation error and standard deviation are 0.02% and 17.6%, respectively, whereas those for a conventional OFS module are 4.09% and 25.7%, respectively.

19.
Materials (Basel) ; 8(2): 519-534, 2015 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-28787954

RESUMEN

An oral medication of a molecular targeted drug, lapatinib, is taken regularly to maintain the drug concentration within the desired therapeutic levels. To alleviate the need for such cumbersome administration schedules in several drugs, advanced drug delivery systems (DDSs), which can provide time-controlled and sustained drug release, have recently received significant attention. A biodegradable synthetic polymer, such as polycaprolactone (PCL), is usually used as a carrier material for DDSs. In this paper, lapatinib powder-entrapped, PCL microstructures were fabricated with a precise X-ray lithography-based method. In vitro experiments on HER2 positive-human gastric cancer derived NCI-N87 cells were performed to appraise the drug release characteristics of the fabricated DDSs. The in vitro results indicate that after the X-ray lithography process, the lapatinib powder is still working well and show time- and dose- dependent drug release efficiencies. The cell growth inhibition characteristics of one hundred 40-µm sized microstructures were similar to those of a 1 µM lapatinib solution for over 144 h. In conclusion, the developed lapatinib-entrapped PCL microstructures can be used in molecular targeted delivery and sustained release as effective cancer-targeted DDSs.

20.
IEEE Trans Biomed Eng ; 62(1): 70-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25020014

RESUMEN

Retinal prosthetic devices stimulate retinal nerve cells with electrical signals proportional to the incident light intensities. For a high-resolution retinal prosthesis, it is necessary to reduce the size of the stimulator pixels as much as possible, because the retinal nerve cells are concentrated in a small area of approximately 5 mm × 5 mm. In this paper, a miniaturized biphasic current stimulator integrated circuit is developed for subretinal stimulation and tested in vitro. The stimulator pixel is miniaturized by using a complementary metal-oxide-semiconductor (CMOS) image sensor composed of three transistors. Compared to a pixel that uses a four-transistor CMOS image sensor, this new design reduces the pixel size by 8.3%. The pixel size is further reduced by simplifying the stimulation-current generating circuit, which provides a 43.9% size reduction when compared to the design reported to be the most advanced version to date for subretinal stimulation. The proposed design is fabricated using a 0.35 µm bipolar-CMOS-DMOS process. Each pixel is designed to fit in a 50 µ m × 55 µm area, which theoretically allows implementing more than 5000 pixels in the 5 mm × 5 mm area. Experimental results show that a biphasic current in the range of 0 to 300 µA at 12 V can be generated as a function of incident light intensities. Results from in vitro experiments with rd1 mice indicate that the proposed method can be effectively used for retinal prosthesis with a high resolution.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Fotometría/instrumentación , Degeneración Retiniana/fisiopatología , Procesamiento de Señales Asistido por Computador/instrumentación , Prótesis Visuales , Animales , Fosfodiesterasas de Nucleótidos Cíclicos Tipo 6/genética , Diseño de Equipo , Análisis de Falla de Equipo , Ratones , Ratones Transgénicos , Degeneración Retiniana/rehabilitación , Transistores Electrónicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...