1.
Sci Total Environ ; 924: 171516, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38458451

RESUMEN

The hygroscopicity of PM2.5 particles plays an important role in PM2.5 haze in Northeast Asian countries by influencing particle growth and chemical composition. New particle formation (NPF) and atmospheric volatile organic compounds (VOCs) are factors that influence particle hygroscopicity. However, the lack of real-time hygroscopicity measurements has deterred the understanding of their effects on particle hygroscopicity. In this study, two intensive monitoring campaigns were conducted during the summer of 2021 and spring of 2022 using real-time aerosol instruments, including a humidified tandem differential mobility analyzer (HTDMA), in Seosan, Republic of Korea. The hygroscopicity parameter κ was calculated from the real-time HTDMA measurement data (κGf). The diurnal variations in κGf exhibited strong inverse linear correlations with the total concentration of VOCs (CTVOC) during the two campaigns. The higher atmospheric CTVOC in summer increased the growth rate of the particle diameter from 10 to 40 nm (6 nm/h) compared with that in spring (2.7 nm/h), resulting in a faster change in κGf for 40-nm particles in summer than in spring because of the increase in organic matter in the chemical compositions of particles. In addition, NPF events introduced additional tiny fresh particles into the atmosphere, which reduced the κGf of 40-nm particles and increased the intensity of the less hygroscopic peaks (κGf < 0.1) of κ-probability density functions (κ-PDF) in NPF days. However, 100-nm particles exhibited fewer changes in κGf than 40-nm particles, resulting in additional dominant hygroscopic peaks (κ âˆ¼ 0.2) of κ-PDFs in both NPF and non-NPF days. When κGf values measured in Seosan were compared with those in other Northeast Asian countries in the literature, the κ values for 40-nm particles were lower than those (κ > 0.2) measured in Beijing and Guangzhou, but those for 100-nm particles were close to those measured in the two cities.

2.
Nanomaterials (Basel) ; 13(2)2023 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-36678034

RESUMEN

Magnesium oxide (MgO) has been investigated as a wet mineral carbonation adsorbent due to its relatively low adsorption and regeneration temperatures. The carbon dioxide (CO2) capture efficiency can be enhanced by applying external force on the MgO slurry during wet carbonation. In this study, two aerosol-processed MgO nanoparticles were tested with a commercial MgO one to investigate the external force effect on the wet carbonation performance at room temperature. The MgO nano-adsorbents were carbonated and sampled every 2 h up to 12 h through forced and non-forced wet carbonations. Hydrated magnesium carbonates (nesquehonite, artinite and hydromagnesite) were formed with magnesite through both wet carbonations. The analyzed results for the time-dependent chemical compositions and physical shapes of the carbonation products consistently showed the enhancement of wet carbonation by the external force, which was at least 4 h faster than the non-forced carbonation. In addition, the CO2 adsorption was enhanced by the forced carbonation, resulting in a higher amount of CO2 being adsorbed by MgO nanoparticles than the non-forced carbonation, unless the carbonation processes were completed. The adsorbed amount of CO2 was between the maximum theoretical amounts of CO2 adsorbed by nesquehonite and hydromagnesite.

3.
Environ Res ; 212(Pt D): 113487, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35594957

RESUMEN

Condensable particulate matter (CPM) corresponds to primary particulate matter ≤2.5 µm (PM2.5) obtained through the condensation of gaseous air pollutants caused by temperature drops in the atmosphere. The internal combustion of vehicle engines can produce CPM because of the condensable compounds in the exhaust gas. Conventional CPM measurement methods have been developed for coal-fired power plants with stable emissions through sampling and off-site analyses. They are therefore unsuitable for detecting the rapidly changing vehicle-originated CPM. In addition, the current system for evaluating PM2.5 from vehicles, based on the particle measurement program (PMP) protocol, provides only the emission factors of total PM2.5 (and not CPM separately) at a fixed temperature (∼25 °C) and dilution ratio (∼ × 35). This study reports, for the first time, the development of a real-time detection method for vehicle-originated CPM through a thermodenuder (TD) integrated with real-time aerosol instruments. This method was designed to reduce the loss of CPM due to condensation and diffusion while sampling the exhaust gas. It permits the investigation of the effects of dilution gas temperature (5-45 °C) and dilution ratio (up to × 30) on the formation of CPM. During the feasibility test of this method using a diesel vehicle (Euro-4), the real-time total particle number concentrations (PNs) matched well with those obtained by a PMP protocol-based evaluation system. Moreover, this method detected PNs concentrations ten times higher than the detection limit (4 × 106 particles/cm3) of the PMP-based system. The emission factors of the total PM2.5 with a bulk density (1 g/cm3) measured by this method also showed consistency with the results of the PMP protocol. The mass emission factor of CPM determined by deploying the TD was ∼14.57 mg/km (∼63% contribution to the total PM2.5).


Asunto(s)
Contaminantes Atmosféricos , Material Particulado , Aerosoles/análisis , Contaminantes Atmosféricos/análisis , Carbón Mineral/análisis , Monitoreo del Ambiente , Gases/análisis , Material Particulado/análisis , Centrales Eléctricas , Emisiones de Vehículos/análisis
4.
World Neurosurg ; 115: 14-23, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29602010

RESUMEN

OBJECTIVE: Susceptibility artifacts from metal clips in magnetic resonance (MR) imaging present an obstacle to evaluating the status of clipped aneurysms, parent arteries, and adjacent brain parenchyma. We aimed to develop MR-compatible aneurysm clips. METHODS: Considering the mechanical and biologic properties, as well as MR compatibility of candidate materials, a prototype clip with a zirconia body and a polyurethane head spring (zirconia clip [ZC], straight, 9-mm long) was developed. The closing forces, opening width of blades, and in vitro and in vivo artifact volumes in 3 tesla MR imaging were compared among the prototype and commercial metal clips such as a Yasargil clip (YC, curved type, 8.3-mm long) and a Sugita clip (SC, straight type, 10-mm long). An in vivo animal study was performed with a canine venous pouch aneurysm model. RESULTS: The closing forces (N) at 1 mm and 8 mm from the blade tip were 2.09 and 3.77 in YC, 1.85 and 3.04 in SC, and 2.05 and 4.60 in ZC. The maximum opening widths (mm) was 6.8, 9.0, and 3.0 in YC, SC, and ZC, respectively. The in vitro artifact volumes of YC, SC, and ZC in time-of-flight MR imaging were 26.9, 29.7, and 1.9 times larger than the respective real volumes. The in vivo artifact volumes of YC, SC, and ZC were respectively 21.4, 29.4, and 2.6 times larger than real ones. CONCLUSIONS: ZC showed the smallest susceptibility artifacts and satisfactory closing forces. However, the narrow opening width of the blades was a weak point.


Asunto(s)
Artefactos , Aneurisma Intracraneal/tratamiento farmacológico , Poliuretanos/farmacología , Circonio/farmacología , Animales , Perros , Diseño de Equipo/métodos , Imagen por Resonancia Magnética/métodos , Instrumentos Quirúrgicos , Titanio
5.
IEEE Trans Biomed Circuits Syst ; 8(6): 799-809, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25532209

RESUMEN

To reduce the memory area, a two-stage RX beamformer (BF) chip with 64 channels is proposed for the ultrasound medical imaging with a 2D CMUT array. The chip retrieved successfully two B-mode phantom images with a steering angle from -45 (°) to +45 (°), the maximum delay range of 8 µs, and the delay resolution of 6.25 ns. An analog-digital hybrid BF (HBF) is chosen for the proposed chip to utilize the easy beamforming operation in the digital domain and also to reduce chip area by minimizing the number of ADCs. The chip consists of eight analog beamformers (ABF) for the 1st-stage and a digital beamformer (DBF) for the 2nd-stage. The two-stage architecture reduces the memory area of both ABF and DBF by around four times. The DBF circuit is divided into three steps to further reduce the digital FIFO memory area by around twice. Coupled with the non-uniform sampling scheme, the proposed two-stage HBF chip reduces the total memory area by around 40 times compared to the uniform-sampling single-stage BF chip. The chip fabricated in a 0.13- µm CMOS process occupies the area of 19.4 mm(2), and dissipates 1.14 W with the analog supply of 3.3 V and the digital supply of 1.2 V.


Asunto(s)
Ultrasonografía/instrumentación , Ultrasonografía/métodos , Humanos , Fantasmas de Imagen
6.
J Korean Neurosurg Soc ; 47(4): 295-7, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20461172

RESUMEN

Candida is a relatively rare cause of spinal infections that commonly affects immunocompromised patients. A 70-year-old woman, who underwent a lumbar discectomy on L5-S1 two months earlier, was admitted to our department complaining of persistent back and leg pain. Magnetic resonance imaging showed irregular enhancing mass lesion in L5-S1 intervertebral space, suggest of pyogenic discitis with epidural abscess. The surgery was performed via retroperitoneal approach and the infected material at L5-S1 intervertebral space was removed. The histological examination of the specimen revealed chronic inflammation involving the bone and soft tissue, and a culture of the excised material was positive for Candida parapsilosis. The patient received intravenous fluconazole for 4 weeks after surgery and oral fluconazole 400 mg/day for 3 months after surgery. The patient made a full recovery with no symptoms 6 months after surgery. We present a rare case of spondylodiscitis after a lumbar discectomy due to Candida parapsilosis and discuss treatment option with a review of the literatures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...