Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PDA J Pharm Sci Technol ; 72(1): 73-80, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29030528

RESUMEN

A real-time polymerase chain reaction (RT-PCR) assay was developed to detect Burkholderia cepacia in pharmaceutical products contaminated with low levels of bacteria. Different pharmaceutical suspensions were artificially contaminated with B. cepacia, Escherichia coli, Staphylococcus aureus, and Bacillus megaterium After a 24 h incubation in trypticase soy broth with Tween 20, samples were streaked on mannitol salt, phenyl ethyl alcohol, eosin methylene blue, MacConkey, and pseudomonas isolation agar. Microbial DNA was extracted from each sample by using a Tris-EDTA, proteinase K, Tween 20 buffer. Regular PCR targeting the 1.5 kilobases 16S rRNA eubacterial gene and cloning showed the predominant DNA in the extracted mix belonged to E. coli Selective media isolation of bacterial contamination showed B. cepacia only detected on pseudomonas isolation while eosin methylene blue and MacConkey detected only E. coli RT-PCR using primers PSL1 and PSR1 amplified a 209 bp 16S rRNA fragment using a Roche LightCycler 96® system with SYBR green I, a common double-stranded binding dye. The cycle at which fluorescence from amplification exceeds the background fluorescence was referred to as quantification cycle. All samples were found to be positive by standard microbiological testing and RT-PCR. B. cepacia was detected within 30 h in all contaminated samples using RT-PCR. Based upon standard curve analysis of B. cepacia DNA, the minimum DNA concentration that could be detected was 10 fg/uL with a correlation value of 0.98. RT-PCR detection of B. cepacia allowed faster quality control analysis, corrective actions, and process optimization.LAY ABSTRACT: A real-time polymerase chain reaction (RT-PCR) assay was developed to detect Burkholderia cepacia in pharmaceutical products contaminated with low levels of bacteria. B. cepacia is the number one reason for microbial contamination recalls of non-sterile drug products in the USA. RT-PCR using primers PSL1 and PSR1 amplified a 209 bp 16S rRNA fragment using a Roche LightCycler 96® system with SYBR green I, a common double-stranded binding dye. All samples were found to be positive by standard microbiological testing and RT-PCR. B. cepacia was detected within 30 h in all contaminated samples using RT-PCR. RT-PCR detection of B. cepacia allowed faster quality control analysis, corrective actions, and process optimization.


Asunto(s)
Burkholderia cepacia/química , Contaminación de Medicamentos , Bacterias , Benzotiazoles , Diaminas , Compuestos Orgánicos , Quinolinas , ARN Ribosómico 16S/química , Reacción en Cadena en Tiempo Real de la Polimerasa
2.
Photochem Photobiol Sci ; 5(5): 449-51, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16685320

RESUMEN

While 1,6-biradicals produced by photodecarbonylation of dimethyl 11-oxodibenzo[c,h]bicyclo[4.4.1]undeca-3,8-diene-1,6-dicarboxylate (1) react exclusively by disproportionation in benzene solution, reactions in crystals lead to radical-radical combination reactions in almost quantitative yield.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...