Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38950655

RESUMEN

BACKGROUND: Catheter ablation is a first-line treatment for symptomatic, recurrent supraventricular tachycardia (SVT). This study aims to demonstrate if 3D-electroanatomic mapping (EAM) during SVT ablation reduces fluoroscopy time (FT) and determine if further reductions in FT are observed longitudinally. METHODS: All cases of SVT ablation between May 2011-May 2022 at a single tertiary centre were prospectively recruited. FT between the cohorts with and without EAM were compared. Within the EAM subset, the trend of FT across the years was analysed. RESULTS: There were 1758 cases included, 563 without EAM, 1195 with EAM. EAM was associated with a longer procedure time (mean + 8.8 min, p = 0.001), but with mean reductions in FT and dose area product (DAP) by 19.6 min and 18 621 mGy*cm2 respectively (p < 0.001). There was comparable efficacy without any increase in complication rates. Over time (2011-2022), further reduction in FT of 0.9 min year on year was observed (p = 0.001). Between 2011 and 2017, there was a significant reduction in FT of 1.1 min year on year (p = 0.019), which was not observed from 2017 onwards (p = 0.061). The greatest reduction in FT was after the first year of adoption. CONCLUSION: EAM in SVT ablation reduces fluoroscopy use. FT was initially observed to reduce further over time before plateauing, likely due to increased operator experience. While there is increased interest in zero fluoroscopy SVT ablation, complementary use of fluoroscopy may still be necessary in complex cases.

2.
Environ Sci Pollut Res Int ; 31(13): 19085-19104, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38376778

RESUMEN

Biogas plant operators often face huge challenges in the monitoring, controlling and optimisation of the anaerobic digestion (AD) process, as it is very sensitive to surrounding changes, which often leads to process failure and adversely affects biogas production. Conventional implemented methods and mechanistic models are impractical and find it difficult to model the nonlinear and intricate interactions of the AD process. Thus, the development of machine learning (ML) algorithms has attracted considerable interest in the areas of process optimization, real-time monitoring, perturbation detection and parameter prediction. This paper provides a comprehensive and up-to-date overview of different machine learning algorithms, including artificial neural network (ANN), fuzzy logic (FL), adaptive network-based fuzzy inference system (ANFIS), support vector machine (SVM), genetic algorithm (GA) and particle swarm optimization (PSO) in terms of working mechanism, structure, advantages and disadvantages, as well as their prediction performances in modelling the biogas production. A few recent case studies of their applications and limitations are also critically reviewed and compared, providing useful information and recommendation in the selection and application of different ML algorithms. This review shows that the prediction efficiency of different ML algorithms is greatly impacted by variations in the reactor configurations, operating conditions, influent characteristics, selection of input parameters and network architectures. It is recommended to incorporate mixed liquor volatile suspended solids (MLVSS) concentration of the anaerobic digester (ranging from 16,500 to 46,700 mg/L) as one of the input parameters to improve the prediction efficiency of ML modelling. This review also shows that the combination of different ML algorithms (i.e. hybrid GA-ANN model) could yield better accuracy with higher R2 (0.9986) than conventional algorithms and could improve the optimization model of AD. Besides, future works could be focused on the incorporation of an integrated digital twin system coupled with ML techniques into the existing Supervisory Control and Data Acquisition (SCADA) system of any biogas plant to detect any operational abnormalities and prevent digester upsets.


Asunto(s)
Biocombustibles , Redes Neurales de la Computación , Anaerobiosis , Algoritmos , Lógica Difusa , Aprendizaje Automático
3.
J Electrocardiol ; 81: 230-236, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37844372

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is a cause of serious morbidity such as stroke. Early detection and treatment of AF is important. Current guidelines recommend screening via opportunistic pulse taking or 12­lead electrocardiogram. Mid-term ECG patch monitors increases the sensitivity of AF detection. METHODS: The Singapore Atrial Fibrillation Study is a prospective multi-centre study aiming to study the incidence of AF in patients with no prior AF and a CHA2DS2-VASc score of at least 1, with the use of a mid-term continuous ECG monitoring device (Spyder ECG). Consecutive patients from both inpatient and outpatient settings were recruited from 3 major hospitals from May 2016 to December 2019. RESULTS: Three hundred and fifty-five patients were monitored. 6 patients (1.7%) were diagnosed with AF. There were no significant differences in total duration of monitoring between the AF and non-AF group (6.39 ± 3.19 vs 5.42 ± 2.46 days, p = 0.340). Patients with newly detected AF were more likely to have palpitations (50.0% vs 11.8%, p = 0.027). Half of the patients (n = 3, 50.0%) were diagnosed on the first day of monitoring and the rest were diagnosed after 24 h. On univariate analysis, only hyperlipidemia was associated with reduced odds of being diagnosed with AF (OR HR 0.08 CI 0.01-0.74, p = 0.025). In a group of 128 patients who underwent coronary artery bypass grafting and had post-operative ECG monitoring, 9 patients (7.0%) were diagnosed with post-operative AF. CONCLUSIONS: The use of non-invasive mid-term patch-based ECG monitoring is an effective modality for AF screening.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Electrocardiografía , Estudios Prospectivos , Tamizaje Masivo
4.
Opt Express ; 31(9): 13798-13805, 2023 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-37157258

RESUMEN

This paper presents a single-photon avalanche diode (SPAD) in 55 nm bipolar-CMOS-DMOS (BCD) technology. In order to realize a SPAD having sub-20 V breakdown voltage for mobile applications while preventing high tunneling noise, a high-voltage N-well available in BCD is utilized to implement the avalanche multiplication region. The resulting SPAD has a breakdown voltage of 18.4 V while achieving an excellent dark count rate of 4.4 cps/µm2 at the excess bias voltage of 7 V in spite of the advanced technology node. At the same time, the device achieves a high peak photon detection probability (PDP) of 70.1% at 450 nm thanks to the high and uniform E-field. Its PDP values at 850 and 940 nm, wavelengths of interest for 3D ranging applications reach 7.2 and 3.1%, respectively, with the use of deep N-well. The timing jitter of the SPAD, full width at half maximum (FWHM), is 91 ps at 850 nm. It is expected that the presented SPAD enables cost-effective time-of-flight and LiDAR sensors with the advanced standard technology for many mobile applications.

5.
Org Lett ; 25(11): 1989-1993, 2023 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-36912487

RESUMEN

Unprotected sugars are selectively acetylated simply by stirring in aqueous solution in the presence of acetic anhydride and a weak base such as sodium carbonate. The reaction is selective for acetylation of the anomeric hydroxyl group of mannose, 2-acetamido, and 2-deoxy sugars and can be performed on a large scale. Competitive intramolecular migration of the 1-O-acetate to the 2-hydroxyl group when these two substituents are cis causes over-reaction and the formation of product mixtures.

6.
J Am Heart Assoc ; 12(7): e026975, 2023 04 04.
Artículo en Inglés | MEDLINE | ID: mdl-36942750

RESUMEN

BACKGROUND Electrocardiography (ECG) may be performed as part of preparticipation sports screening. Recommendations on screening of athletes to identify individuals with previously unrecognized cardiac disease are robust; however, data guiding the preparticipation screening of unselected populations are scarce. T wave inversion (TWI) on ECG may suggest an undiagnosed cardiomyopathy. This study aims to describe the prevalence of abnormal TWI in an unselected young male cohort and the outcomes of an echocardiography-guided approach to investigating these individuals for structural heart diseases, focusing on the yield for cardiomyopathies. METHODS AND RESULTS Consecutive young male individuals undergoing a national preparticipation cardiac screening program for 39 months were studied. All underwent resting supine 12-lead ECG. Those manifesting abnormal TWI, defined as negatively deflected T waves of at least 0.1 mV amplitude in any 2 contiguous leads, underwent echocardiography. A total of 69 714 male individuals with a mean age of 17.9±1.1 years were studied. Of the individuals, 562 (0.8%) displayed abnormal TWI. This was most frequently observed in the anterior territory and least so in the lateral territory. A total of 12 individuals (2.1%) were diagnosed with a cardiomyopathy. Cardiomyopathy diagnoses were significantly associated with deeper maximum TWI depth and the presence of abnormal TWI in the lateral territory, but not with abnormal TWI in the anterior and inferior territories. No individual presenting with TWI restricted to solely leads V1 to V2, 2 inferior leads or both was diagnosed with a cardiomyopathy. CONCLUSIONS Cardiomyopathy diagnoses were more strongly associated with certain patterns of abnormal TWI. Our findings may support decisions to prioritize echocardiography in these individuals.


Asunto(s)
Cardiomiopatías , Ecocardiografía , Cardiopatías , Adolescente , Adulto , Humanos , Masculino , Adulto Joven , Arritmias Cardíacas/diagnóstico , Cardiomiopatías/diagnóstico , Electrocardiografía/métodos , Corazón
7.
Nat Commun ; 14(1): 882, 2023 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-36797286

RESUMEN

A nanoscale on-chip light source with high intensity is desired for various applications in integrated photonics systems. However, it is challenging to realize such an emitter using materials and fabrication processes compatible with the standard integrated circuit technology. In this letter, we report an electrically driven Si light-emitting diode with sub-wavelength emission area fabricated in an open-foundry microelectronics complementary metal-oxide-semiconductor platform. The light-emitting diode emission spectrum is centered around 1100 nm and the emission area is smaller than 0.14 µm2 (~[Formula: see text] nm). This light-emitting diode has high spatial intensity of >50 mW/cm2 which is comparable with state-of-the-art Si-based emitters with much larger emission areas. Due to sub-wavelength confinement, the emission exhibits a high degree of spatial coherence, which is demonstrated by incorporating the light-emitting diode into a compact lensless in-line holographic microscope. This centimeter-scale, all-silicon microscope utilizes a single emitter to simultaneously illuminate ~9.5 million pixels of a complementary metal-oxide-semiconductor imager.

8.
Front Pharmacol ; 14: 1328950, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38273820

RESUMEN

Snakebite envenoming results in ∼100,000 deaths per year, with close to four times as many victims left with life-long sequelae. Current antivenom therapies have several limitations including high cost, variable cross-snake species efficacy and a requirement for intravenous administration in a clinical setting. Next-generation snakebite therapies are being widely investigated with the aim to improve cost, efficacy, and safety. In recent years several small molecule drugs have shown considerable promise for snakebite indication, with oral bioavailability particularly promising for community delivery rapidly after a snakebite. However, only two such drugs have entered clinical development for snakebite. To offset the risk of attrition during clinical trials and to better explore the chemical space for small molecule venom toxin inhibitors, here we describe the first high throughput drug screen against snake venom metalloproteinases (SVMPs)-a pathogenic toxin family responsible for causing haemorrhage and coagulopathy. Following validation of a 384-well fluorescent enzymatic assay, we screened a repurposed drug library of 3,547 compounds against five geographically distinct and toxin variable snake venoms. Our drug screen resulted in the identification of 14 compounds with pan-species inhibitory activity. Following secondary potency testing, four SVMP inhibitors were identified with nanomolar EC50s comparable to the previously identified matrix metalloproteinase inhibitor marimastat and superior to the metal chelator dimercaprol, doubling the current global portfolio of SVMP inhibitors. Following analysis of their chemical structure and ADME properties, two hit-to-lead compounds were identified. These clear starting points for the initiation of medicinal chemistry campaigns provide the basis for the first ever designer snakebite specific small molecules.

10.
J Arrhythm ; 38(5): 827-830, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36226093

RESUMEN

Palpitations is one of the most common side effects experienced post-messenger-RNA COVID-19 vaccines. However, some patients experience significant symptoms and further workup needs to be considered. We present an interesting case of inappropriate sinus tachycardia in a fit gentleman who presented with worsening palpitations and elevated heart rate post-first and -second dose of the Pfizer/BioNTech vaccine.

11.
RSC Adv ; 12(25): 15631-15642, 2022 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-35685699

RESUMEN

Bioorthogonal chemistry can facilitate the development of fluorescent probes that can be used to sensitively and specifically detect the presence of biological targets. In this study, such an assay was developed to evaluate the uptake and delivery of antimicrobials into Escherichia coli, building on and extending previous work which utilised more resource intensive LCMS detection. The bacteria were genetically engineered to express streptavidin in the periplasmic or cytoplasmic compartments, which was used to localise a bioorthogonal probe (BCN-biotin). Azido-compounds which are delivered to these compartments react with the localised BCN-biotin-streptavidin in a concentration-dependent manner via a strain-promoted alkyne-azide cycloaddition. The amount of azido-compound taken up by bacteria was determined by quantifying unreacted BCN-biotin-streptavidin via an inverse electron demand Diels-Alder reaction between remaining BCN-biotin and a tetrazine-containing fluorescent dye. Following optimisation and validation, the assay was used to assess uptake of liposome-formulated azide-functionalised luciferin and cefoxitin. The results demonstrated that formulation into cationic liposomes improved the uptake of azide-functionalised compounds into the periplasm of E. coli, providing insight on the uptake mechanism of liposomes in the bacteria. This newly developed bioorthogonal fluorescence plate-reader based assay provides a bioactivity-independent, medium-to-high throughput tool for screening compound uptake/delivery.

12.
Pacing Clin Electrophysiol ; 45(5): 666-673, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35417608

RESUMEN

AIMS: Conduction system pacing has gained steady interest over recent years. While the majority of tools and delivery techniques were developed for His bundle pacing (HBP), the feasibility and reproducibility of using these similar tools for left bundle branch pacing (LBBP) has yet to be determined. We describe our technique for performing LBBP using the Abbott Agilis HisPro™ Steerable Catheter. METHODS AND RESULTS: A series of 22 patients with a mean age of 71.7 years (16 males, 72.7%), underwent LBBP procedure with this catheter between May and October 2021. Nineteen patients (86%) had successful LBBP lead implantation. There were no major complications or mortality. CONCLUSION: The Agilis HisPro™ catheter along with the stylet driven Tendril STS Model 2088TC lead is a safe and feasible delivery system for LBBP.


Asunto(s)
Fascículo Atrioventricular , Terapia de Resincronización Cardíaca , Anciano , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca/métodos , Catéteres , Electrocardiografía , Sistema de Conducción Cardíaco , Humanos , Masculino , Reproducibilidad de los Resultados
13.
Pacing Clin Electrophysiol ; 45(1): 50-58, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34792208

RESUMEN

BACKGROUND: The Singapore Cardiac Databank was designed to monitor the performance and outcomes of catheter ablation. We investigated the outcomes of paroxysmal supraventricular tachycardia (PSVT)-ablation in a prospective, nationwide, cohort study. METHODS: Atrioventricular nodal re-entrant tachycardia (AVNRT), atrioventricular re-entry tachycardia (AVRT), or atrial tachycardia (AT)-ablations in Singapore from 2010 to 2018 were studied. Outcomes include acute success, periprocedural-complications, postoperative pacing requirement, arrhythmic recurrence and 1-year all-cause mortality. RESULTS: Among 2260 patients (mean age 45 ± 18 years, 50% female, 57% AVNRT, 37% AVRT, 6% AT), overall acute success rates of PSVT-ablation was 98.4% and increased in order of AT, AVRT, and AVNRT (p < .001). Periprocedural cardiac tamponade occurred in two AVRT patients. A total of 15 pacemakers (6 within first 30-days, 9 after 30-days) were implanted (seven AV block, eight sinus node dysfunction [SND]), with the highest incidence of pacemaker implantation after AT-ablation (5% vs. 0.6% AVNRT vs. 0.1% AVRT, p < .001). Repeat ablations (0.9% AVNRT, 7% AVRT, 4% AT, p < .001) were performed in 78 (3.5%) patients and 13 (0.6%) patients died within a year of ablation. Among outcomes considered adjusting for age, sex, PSVT-type and procedure-time, AT was independently associated with 6-fold increased odds of total (adjusted odds ratio [AOR] 6.32, 95% confidence interval [CI] 1.95-20.53) and late (AOR 6.38, 95% CI 1.39-29.29) pacemaker implantation, while AVRT was associated with higher arrhythmic recurrence with repeat ablations (AOR 4.72, 95% CI 2.36-9.44) compared to AVNRT. CONCLUSIONS: Contemporary PSVT ablation is safe with high acute success rates. Long-term outcomes differed by nature of the PSVT.


Asunto(s)
Ablación por Catéter/métodos , Taquicardia Supraventricular/cirugía , Estimulación Cardíaca Artificial/estadística & datos numéricos , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Recurrencia , Sistema de Registros , Singapur/epidemiología , Taquicardia Supraventricular/epidemiología , Taquicardia Supraventricular/mortalidad
14.
Eur Cardiol ; 16: e23, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34135993

RESUMEN

The disease burden of AF is greater in Asia-Pacific than other areas of the world. Direct oral anticoagulants (DOACs) have emerged as effective alternatives to vitamin K antagonists (VKA) for preventing thromboembolic events in patients with AF. The Asian Pacific Society of Cardiology developed this consensus statement to guide physicians in the management of AF in Asian populations. Statements were developed by an expert consensus panel who reviewed the available data from patients in Asia-Pacific. Consensus statements were developed then put to an online vote. The resulting 17 statements provide guidance on the assessment of stroke risk of AF patients in the region, the appropriate use of DOACs in these patients, as well as the concomitant use of DOACs and antiplatelets, and the transition to DOACs from VKAs and vice versa. The periprocedural management of patients on DOAC therapy and the management of patients with bleeding while on DOACs are also discussed.

15.
J Med Chem ; 64(12): 8161-8178, 2021 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-34120444

RESUMEN

Adenosine receptors are attractive therapeutic targets for multiple conditions, including ischemia-reperfusion injury and neuropathic pain. Adenosine receptor drug discovery efforts would be facilitated by the development of appropriate tools to assist in target validation and direct receptor visualization in different native environments. We report the development of the first bifunctional (chemoreactive and clickable) ligands for the adenosine A1 receptor (A1R) and adenosine A3 receptor (A3R) based on an orthosteric antagonist xanthine-based scaffold and on an existing structure-activity relationship. Bifunctional ligands were functional antagonists with nanomolar affinity and irreversible binding at the A1R and A3R. In-depth pharmacological profiling of these bifunctional ligands showed moderate selectivity over A2A and A2B adenosine receptors. Once bound to the receptor, ligands were successfully "clicked" with a cyanine-5 fluorophore containing the complementary "click" partner, enabling receptor detection. These bifunctional ligands are expected to aid in the understanding of A1R and A3R localization and trafficking in native cells and living systems.


Asunto(s)
Antagonistas del Receptor de Adenosina A1/farmacología , Antagonistas del Receptor de Adenosina A3/farmacología , Sondas Moleculares/farmacología , Receptor de Adenosina A1/metabolismo , Receptor de Adenosina A3/metabolismo , Xantinas/farmacología , Antagonistas del Receptor de Adenosina A1/síntesis química , Antagonistas del Receptor de Adenosina A3/síntesis química , Alquinos/química , Animales , Azidas/química , Células CHO , Química Clic , Cricetulus , Diseño de Fármacos , Colorantes Fluorescentes/química , Humanos , Ligandos , Sondas Moleculares/síntesis química , Receptor de Adenosina A1/química , Receptor de Adenosina A3/química , Xantinas/síntesis química
16.
Kardiol Pol ; 79(6): 654-661, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33885269

RESUMEN

BACKGROUND: Classical electrocardiographic (ECG) criteria for left ventricular hypertrophy (LVH) are well studied in older populations and patients with hypertension. Their utility in young pre-participation cohorts is unclear. AIMS: We aimed to develop machine learning models for detection of echocardiogram-diagnosed LVH from ECG, and compare these models with classical criteria. METHODS: Between November 2009 and December 2014, pre-participation screening ECG and subsequent echocardiographic data was collected from 17 310 males aged 16 to 23, who reported for medical screening prior to military conscription. A final diagnosis of LVH was made during echocardiography, defined by a left ventricular mass index >115 g/m2. The continuous and threshold forms of classical ECG criteria (Sokolow-Lyon, Romhilt-Estes, Modified Cornell, Cornell Product, and Cornell) were compared against machine learning models (Logistic Regression, GLMNet, Random Forests, Gradient Boosting Machines) using receiver-operating characteristics curve analysis. We also compared the important variables identified by machine learning models with the input variables of classical criteria. RESULTS: Prevalence of echocardiographic LVH in this population was 0.82% (143/17310). Classical ECG criteria had poor performance in predicting LVH. Machine learning methods achieved superior performance: Logistic Regression (area under the curve [AUC], 0.811; 95% confidence interval [CI], 0.738-0.884), GLMNet (AUC, 0.873; 95% CI, 0.817-0.929), Random Forest (AUC, 0.824; 95% CI, 0.749-0.898), Gradient Boosting Machines (AUC, 0.800; 95% CI, 0.738-0.862). CONCLUSIONS: Machine learning methods are superior to classical ECG criteria in diagnosing echocardiographic LVH in the context of pre-participation screening.


Asunto(s)
Hipertensión , Hipertrofia Ventricular Izquierda , Anciano , Ecocardiografía , Electrocardiografía , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Aprendizaje Automático , Masculino
17.
Singapore Med J ; 62(8): 390-403, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-35001112

RESUMEN

Advanced cardiac life support (ACLS) emphasises the use of advanced airway management and ventilation, circulatory support and the appropriate use of drugs in resuscitation, as well as the identification of reversible causes of cardiac arrest. Extracorporeal cardiopulmonary resuscitation and organ donation, as well as special circumstances including drowning, pulmonary embolism and pregnancy are addressed. Resuscitation does not end with ACLS but must continue in post-resuscitation care. ACLS also covers the recognition and management of unstable pre-arrest tachy- and bradydysrhythmias that may deteriorate further.


Asunto(s)
Apoyo Vital Cardíaco Avanzado , Reanimación Cardiopulmonar , Paro Cardíaco , Apoyo Vital Cardíaco Avanzado/métodos , Manejo de la Vía Aérea , Paro Cardíaco/terapia , Humanos , Guías de Práctica Clínica como Asunto , Singapur
18.
Addiction ; 116(3): 506-513, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32621553

RESUMEN

AIM: To describe the assignment of International Classification of Disease (ICD)-10 alcohol codes as underlying or contributory causes of death by the Australian Bureau of Statistics during mortality coding for suicides according to the blood alcohol concentration (BAC) detected at autopsy. DESIGN: Population-based case-series descriptive analysis. SETTING AND PARTICIPANTS: Data for all alcohol-related (Alc+) suicide deaths (aged 15+) in Australia from 2010-2015 (n = 3132) from the National Coronial Information System. MEASUREMENTS: Alc+ suicides were categorised as those with a post-mortem BAC ≥0.05 g/100 mL. The outcome variable was whether the case was assigned an ICD-10 alcohol code (F10.0-F10.9, R78.0, T51, X45 and/or X65). We estimated OR for the assignment of codes in Alc+ suicides using BAC as the key predictor. We also examined several covariates that have been implicated in the risk of Alc+ suicides. FINDINGS: An ICD-10 alcohol code was assigned during the mortality coding process in 47.6% (n = 1491) of Alc+ suicides. Higher BAC was associated with higher odds of having a code assigned; cases with a BAC over 0.20 g/100 mL over were twice as likely to have an alcohol code assigned (adjusted OR [AOR] = 2.06, 95% CI = 1.59, 2.67) compared with cases with a BAC of 0.050-0.075 g/100 mL. Compared with New South Wales, higher likelihood of code assignment was found in Northern Territory (AOR = 3.85, 95% CI = 2.32, 6.63) and Western Australia (AOR = 2.89, 95% CI = 2.27, 3.68). Compared with 15-24 year olds, 25-44 (AOR = 0.79, 95% CI = 0.63, 0.99) and 65-84 year olds (AOR = 0.63, 95% CI = 0.43, 0.93) were less likely to have a code assigned. CONCLUSIONS: An ICD-10 alcohol code was not assigned as an underlying or contributory cause of death in over half of suicides in Australia (2010-2015) with a BAC ≥0.05 g/100 mL. The higher the BAC detected at autopsy, the more likely cases were to be assigned an alcohol code during the mortality coding process.


Asunto(s)
Nivel de Alcohol en Sangre , Suicidio , Australia/epidemiología , Autopsia , Causas de Muerte , Etanol , Humanos
19.
NMR Biomed ; 33(9): e4328, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32542861

RESUMEN

Macromolecular signals are crucial constituents of short echo-time 1 H MR spectra with potential clinical implications in themselves as well as essential ramifications for the quantification of the usually targeted metabolites. Their parameterization, needed for general fitting models, is difficult because of their unknown composition. Here, a macromolecular signal parameterization together with metabolite signal quantification including relaxation properties is investigated by multidimensional modeling of interrelated 2DJ inversion-recovery (2DJ-IR) datasets. Simultaneous and iterative procedures for defining the macromolecular background (MMBG) as mono-exponentially or generally decaying signals over TE are evaluated. Varying prior knowledge and restrictions in the metabolite evaluation are tested to examine their impact on results and fitting stability for two sets of three-dimensional spectra acquired with metabolite-cycled PRESS from cerebral gray and white matter locations. One dataset was used for model optimization, and also examining the influence of prior knowledge on estimated parameters. The most promising model was applied to a second dataset. It turned out that the mono-exponential decay model appears to be inadequate to represent TE-dependent signal features of the MMBG. TE-adapted MMBG spectra were therefore determined. For a reliable overall quantification of implicated metabolite concentrations and relaxation times, a general fitting model had to be constrained in terms of the number of fitting variables and the allowed parameter space. With such a model in place, fitting precision for metabolite contents and relaxation times was excellent, while fitting accuracy is difficult to judge and bias was likely influenced by the type of fitting constraints enforced. In summary, the parameterization of metabolite and macromolecule contributions in interrelated MR spectra has been examined by using multidimensional modeling on complex 2DJ-IR datasets. A tightly restricted model allows fitting of individual subject data with high fitting precision documented in small Cramér-Rao lower bounds, good repeatability values and a relatively small spread of estimated concentration and relaxation values for a healthy subject cohort.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Sustancias Macromoleculares/metabolismo , Espectroscopía de Resonancia Magnética , Metaboloma , Modelos Biológicos , Adulto , Bases de Datos como Asunto , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA