ESC Heart Fail ; 5(6): 1173-1175, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30295431

RESUMEN

The aim of this case report is to assess the potential role of intrarenal Doppler ultrasonography as a non-invasive method to evaluate intrarenal venous flow (IRVF) in acute heart failure (AHF) and concomitant renal dysfunction. We report a case of an 81-year-old woman with valvular heart disease (previous mitral valve replacement) that presented with acutely decompensated heart failure and concomitant worsening renal function (WRF). In addition to complete physical examination, laboratory analysis, and echocardiography, IRVF was assessed at baseline and 48 h after the administration of diuretic treatment. At admission, physical examination and echocardiography revealed signs of intravascular congestion (jugular venous distension and severely dilated inferior vena cava). In addition, a significant increase in serum creatinine from 1.23 to 1.81 mg/dL was noted without signs of hypoperfusion at clinical evaluation. At baseline, intrarenal Doppler ultrasonography showed a monophasic IRVF pattern indicating a severely elevated interstitial renal pressure. After aggressive decongestion, a dynamic behaviour was found in IRVF changing from monophasic to biphasic pattern in parallel with an improvement in clinical parameters and renal function (serum creatinine changed from 1.81 to 1.44 mg/dL). In this case of a patient with AHF and WRF, IRVF changed after aggressive decongestion in agreement with clinical evolution. According to these findings, this technique could provide valuable information for identifying patients with a 'congestion kidney failure' phenotype. Further studies are needed confirming this observation and evaluating the potential role of this technique for guiding decongestive therapy in patients with AHF and WRF.


Asunto(s)
Síndrome Cardiorrenal/fisiopatología , Riñón/irrigación sanguínea , Flujo Sanguíneo Regional/fisiología , Circulación Renal/fisiología , Venas Renales/fisiopatología , Anciano de 80 o más Años , Síndrome Cardiorrenal/diagnóstico , Femenino , Humanos , Riñón/diagnóstico por imagen , Riñón/fisiopatología , Venas Renales/diagnóstico por imagen , Ultrasonografía Doppler
2.
Circ Arrhythm Electrophysiol ; 8(4): 882-9, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26056239

RESUMEN

BACKGROUND: Epicardial ablation has shown improvement in clinical outcomes of patients with ischemic heart disease (IHD) after ventricular tachycardia (VT) ablation. However, usually epicardial access is only performed when endocardial ablation has failed. Our aim was to compare the efficacy of endocardial+epicardial ablation versus only endocardial ablation in the first procedure in patients with IHD. METHODS AND RESULTS: Fifty-three patients with IHD, referred for a first VT ablation to our institution, from 2012 to 2014, were included. They were divided in 2 groups according to enrollment time: from May 2013, we started to systematically perform endo-epicardial access (Epi-Group) as first-line approach in consecutive patients with IHD (n=15). Patients who underwent only an endocardial VT ablation in their first procedure (Endo-Group) included patients with previous cardiac surgery and the historical (before May 2013; n=35). All late-potentials in the scar zone were eliminated, and if VT was tolerated, critical isthmuses were also approached. The end point was the noninducibility of any VT. During a median follow-up of 15±10 months, the combined end point (hospital or emergency admission because of a ventricular tachycardia or reablation) occurred in 14 patients of the Endo-group and in one patient in the Epi-group (event-free survival curves by Grey-test, P=0.03). Ventricular arrhythmia recurrences occurred in 16 and in 3 patients in the Endo and Epi-Group, respectively (Grey-test, P=0.2). CONCLUSIONS: A combined endocardial-epicardial ablation approach for initial VT ablation was associated with fewer readmissions for VT and repeat ablations. Further studies are warranted.


Asunto(s)
Ablación por Catéter/métodos , Electrocardiografía , Endocardio/cirugía , Sistema de Conducción Cardíaco/cirugía , Isquemia Miocárdica/complicaciones , Guías de Práctica Clínica como Asunto , Taquicardia Ventricular/cirugía , Anciano , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/fisiopatología , Recurrencia , Estudios Retrospectivos , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
3.
Arch Cardiol Mex ; 84(1): 4-9, 2014.
Artículo en Español | MEDLINE | ID: mdl-24636049

RESUMEN

OBJECTIVE: The recommendations for complete lead extraction because of local complications at the site of implantable devices have changed in the last 10 years. We analyze the outcome of patients who required an intervention because of a local complication between 2002 and 2010, in our Hospital. METHODS: We retrospectively studied 83 patients with a local complication that was classified according to skin integrity: 1. Integrity, and 2. Open skin. We analyzed the type of intervention: 1. Conservative approach, 2. Incomplete extraction, 3. Complete extraction. The endpoints were the needing a later intervention and a complete removal during follow up. RESULTS: The group of patients with complete system extraction showed a lower rate of re-intervention during an average follow up of 1000 days, when compared to other two groups (6.7% vs. 57.7 and 43.8%, P<.01). Incomplete extraction and conservative approach had a similar outcome, needing a complete extraction 25% and 37.5%, respectively. The skin integrity did not seem to be relevant for outcome in these two groups. An 8.4% incidence of endocarditis was observed; all of them had a previous history of incomplete extraction or conservative approach. CONCLUSIONS: Local complications treated with either a conservative approach or incomplete extraction are associated with a high rate of re-interventions, regardless of skin integrity, frequently needing final complete extraction and are associated to endocarditis.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Humanos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos
4.
Arch. cardiol. Méx ; 84(1): 4-9, ene.-mar. 2014. ilus, tab
Artículo en Español | LILACS | ID: lil-712904

RESUMEN

Objetivo: Las recomendaciones para la extracción completa de la bolsa de dispositivos implantables por problemas locales han cambiado. Analizamos la evolución entre 2002 y 2010 de los pacientes que requirieron una intervención por una complicación local en nuestro centro. Métodos: Ochenta y tres pacientes tuvieron un problema local de la bolsa que se clasificó según integridad de la piel: 1. Íntegra y 2. Abierta, y el tipo de intervención realizada: 1. Conservadora, 2. Extracción parcial y 3. Extracción completa. El objetivo primario fue la necesidad de reintervención posterior y la de extracción total durante el seguimiento. Resultados: El grupo de pacientes con extracción completa presentó una menor tasa de reintervención durante el seguimiento medio de 1,000 días comparado con los otros 2 grupos (6.7 vs. 57.7 y 43.8%, p < 0.01). La extracción parcial y la actitud conservadora mostraron una evolución parecida con una tasa de extracción completa final del 25% y del 37.5%. Se observó una incidencia de endocarditis del 8.4%; todos con antecedente de extracción parcial o actitud conservadora. Conclusiones: Las complicaciones de la bolsa, independientemente de la integridad de la piel, tratadas conservadoramente o con extracción parcial se asocian a alta tasa de reintervenciones, necesidad de extracción completa y evolución a endocarditis.


Objective: The recommendations for complete lead extraction because of local complications at the site of implantable devices have changed in the last 10 years. We analyze the outcome of patients who required an intervention because of a local complication between 2002 and 2010, in our Hospital. Methods: We retrospectively studied 83 patients with a local complication that was classified according to skin integrity: 1. Integrity, and 2. Open skin. We analyzed the type of intervention: 1. Conservative approach, 2. Incomplete extraction, 3. Complete extraction. The endpoints were the needing a later intervention and a complete removal during follow up. Results: The group of patients with complete system extraction showed a lower rate of reintervention during an average follow up of 1000 days, when compared to other two groups (6.7% vs. 57.7 and 43.8%, P<.01). Incomplete extraction and conservative approach had a similar outcome, needing a complete extraction 25% and 37.5%, respectively. The skin integrity did not seem to be relevant for outcome in these two groups. An 8.4% incidence of endocarditis was observed; all of them had a previous history of incomplete extraction or conservative approach. Conclusions: Local complications treated with either a conservative approach or incomplete extraction are associated with a high rate of re-interventions, regardless of skin integrity, frequently needing final complete extraction and are associated to endocarditis.


Asunto(s)
Humanos , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos
5.
IEEE Trans Biomed Eng ; 58(1): 43-53, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20851784

RESUMEN

Dofetilide is a class-III drug that inhibits the rapid component of the delayed potassium current ( I(Kr)). Experimental studies have shown that the different layers of ventricular muscle present differences in action potential duration (APD) and different responses to class III agents. It has been suggested that it contributes to APD heterogeneity in the ventricles. However, in vivo studies suggest that the strong cellular coupling reduces APD dispersion in intact heart. The aim of this paper is to study the effect of dofetilide on the action potentials (APs) in isolated ventricular cells and on APD dispersion in a strand of ventricular tissue. A mathematical model of dofetilide effects on I(Kr) has been developed and incorporated into the Luo--Rudy dynamic model of ventricular AP. Our results show that dofetilide induces in midmyocardium cells a faster time-course inhibition of I(Kr) than in endocardial or epicardial cells, and periods of instability with beat-to-beat APs variability. This behavior could favor temporal dispersion of repolarization between the different cells. The results also indicate that although dofetilide increases, the transmural gradient of APD in the ventricular wall, early afterdepolarizations (EADs) did not appear even under strong uncoupling conditions. However, reduced repolarization reserve favors the induction of EADs, even under normal coupling conditions.


Asunto(s)
Antiarrítmicos/farmacología , Corazón/efectos de los fármacos , Modelos Cardiovasculares , Fenetilaminas/farmacología , Sulfonamidas/farmacología , Potenciales de Acción/efectos de los fármacos , Algoritmos , Animales , Células Cultivadas , Simulación por Computador , Cobayas , Ventrículos Cardíacos/citología , Ventrículos Cardíacos/efectos de los fármacos , Miocardio/citología , Técnicas de Placa-Clamp
SELECCIÓN DE REFERENCIAS