Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
J Am Coll Cardiol ; 84(10): 889-900, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39197978

RESUMEN

BACKGROUND: The prevalence of and outcomes associated with different antithrombotic strategies after left atrial appendage occlusion (LAAO) are not well described. OBJECTIVES: This study sought to evaluate patterns of antithrombotic medication strategies at discharge following LAAO with the Watchman FLX device in real-world practice and to compare the risk of adverse events among the different antithrombotic regimens. METHODS: The authors evaluated patients in the NCDR (National Cardiovascular Data Registry) LAAO Registry who underwent LAAO with the second-generation LAA closure device between 2020 and 2022. They grouped patients by mutually exclusive discharge antithrombotic strategies and compared the rates of adverse events at 45 days and 6 months using multivariable Cox proportional hazards regression. RESULTS: Among 53,878 patients undergoing successful LAAO with the second-generation LAA closure device, the most common antithrombotic discharge regimens were direct oral anticoagulant (DOAC) plus aspirin (48.3%), DOAC alone (22.6%), dual antiplatelet therapy (8.1%), warfarin plus aspirin (7.7%), and DOAC plus P2Y12 inhibitor (4.9%). In multivariate analysis, DOAC alone had a lower rate of major adverse events and major bleeding at 45 days of follow-up compared with DOAC plus aspirin (major adverse events: HR: 0.78; 95% CI: 0.68-0.91; major bleeding: HR: 0.69; 95% CI: 0.60-0.80). These differences persisted at 6 months. Warfarin without aspirin also showed lower rates of major bleeding at both time points. No differences were seen in stroke/transient ischemic attack or device-related thrombus. CONCLUSIONS: In real-world U.S. practice, discharge on DOAC alone or warfarin alone was associated with a lower rate of adverse events compared with DOAC plus aspirin.


Asunto(s)
Anticoagulantes , Aspirina , Apéndice Atrial , Fibrilación Atrial , Inhibidores de Agregación Plaquetaria , Humanos , Apéndice Atrial/cirugía , Masculino , Femenino , Aspirina/administración & dosificación , Aspirina/efectos adversos , Aspirina/uso terapéutico , Anciano , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/complicaciones , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Sistema de Registros , Anciano de 80 o más Años , Terapia Antiplaquetaria Doble/métodos , Quimioterapia Combinada , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/epidemiología , Persona de Mediana Edad
2.
Circ Cardiovasc Interv ; : e013750, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39056187

RESUMEN

BACKGROUND: PINNACLE FLX (Protection Against Embolism for Nonvalvular AF Patients: Investigational Device Evaluation of the WATCHMAN FLX LAA Closure Technology) demonstrated improved outcomes and low incidence of adverse events with the WATCHMAN FLX device in a controlled setting. The National Cardiovascular Disease Registry's Left Atrial Appendage Occlusion Registry was utilized to assess the safety and effectiveness of WATCHMAN FLX in contemporary clinical practice in the United States. METHODS: The WATCHMAN FLX Device Surveillance Post Approval Analysis Plan used data from the Left Atrial Appendage Occlusion registry to identify patients undergoing WATCHMAN FLX implantation between August 2020 and September 2022. The key safety end point was defined as all-cause death, ischemic stroke, systemic embolism, or device or procedure-related events requiring open cardiac surgery or major endovascular intervention between device implantation and hospital discharge. Major adverse events were reported at hospital discharge, 45 days, and 1 year. RESULTS: Among 97 185 patients in the Left Atrial Appendage Occlusion registry undergoing WATCHMAN FLX, successful implantation occurred in 97.5% (n=94 784) of patients. The key safety end point occurred in 0.45% of patients. At 45 days post-procedure, all-cause death occurred in 0.81% patients, ischemic stroke in 0.23%, major bleeding in 3.1%, pericardial effusion requiring intervention in 0.50%, device-related thrombus in 0.44%, and device embolism in 0.04% patients. No peri-device leak was observed in 83.1% of patients at 45 days. At 1 year, the rate of all-cause death was 8.2%, the rate of any stroke was 1.5% (ischemic stroke, 1.2%), and major bleeding occurred in 6.4% of patients. CONCLUSIONS: In a large contemporary cohort of patients with the WATCHMAN FLX device, the rates of implant success and clinical outcomes through 1 year were comparable with the PINNACLE FLX study, demonstrating that favorable outcomes achieved in the pivotal approval study can be replicated in routine clinical practice.

3.
Am Heart J ; 264: 123-132, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37279840

RESUMEN

BACKGROUND: Percutaneous left atrial appendage (LAA) closure (LAAC) was developed as a nonpharmacologic alternative to oral anticoagulants (OACs) in patients with atrial fibrillation (AF) who are at an increased risk for stroke or systemic embolism. The Watchman device permanently seals off the LAA to prevent thrombi from escaping into the circulation. Previous randomized trials have established the safety and efficacy of LAAC compared to warfarin. However, direct OACs (DOACs) have become the preferred pharmacologic strategy for stroke prevention in patients with AF, and there is limited data comparing Watchman FLX to DOACs in a broad AF patient population. CHAMPION-AF is designed to prospectively determine whether LAAC with Watchman FLX is a reasonable first-line alternative to DOACs in patients with AF who are indicated for OAC therapy. STUDY DESIGN: A total of 3,000 patients with a CHA2DS2-VASc score ≥2 (men) or ≥3 (women) were randomized to Watchman FLX or DOAC in a 1:1 allocation at 142 global clinical sites. Patients in the device arm were to be treated with DOAC and aspirin, DOAC alone, or DAPT for at least 3 months postimplant followed by aspirin or P2Y12 inhibitor for 1-year. Control patients were required to take an approved DOAC for the duration of the trial. Clinical follow-up visits are scheduled at 3- and 12-months, and then annually through 5 years; LAA imaging is required at 4 months in the device group. Two primary end points will be evaluated at 3 years: (1) composite of stroke (ischemic/hemorrhagic), cardiovascular death, and systemic embolism compared for noninferiority, and (2) nonprocedural bleeding (International Society on Thrombosis and Haemostasis [ISTH] major and clinically relevant nonmajor bleeding) tested for superiority in the device arm against DOACs. The third primary noninferiority end point is the composite of ischemic stroke and systemic embolism at 5 years. Secondary end points include 3- and 5-year rates of (1) ISTH-defined major bleeding and (2) the composite of cardiovascular death, all stroke, systemic embolism, and nonprocedural ISTH bleeding. CONCLUSIONS: This study will prospectively evaluate whether LAAC with the Watchman FLX device is a reasonable alternative to DOACs in patients with AF. CLINICAL TRIAL REGISTRATION: NCT04394546.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Accidente Cerebrovascular , Masculino , Humanos , Femenino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Resultado del Tratamiento , Estudios de Seguimiento , Apéndice Atrial/cirugía , Anticoagulantes/uso terapéutico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/epidemiología , Hemorragia/inducido químicamente , Hemorragia/complicaciones , Aspirina/uso terapéutico , Embolia/prevención & control
4.
Med Image Anal ; 88: 102799, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37245434

RESUMEN

ImUnity is an original 2.5D deep-learning model designed for efficient and flexible MR image harmonization. A VAE-GAN network, coupled with a confusion module and an optional biological preservation module, uses multiple 2D slices taken from different anatomical locations in each subject of the training database, as well as image contrast transformations for its training. It eventually generates 'corrected' MR images that can be used for various multi-center population studies. Using 3 open source databases (ABIDE, OASIS and SRPBS), which contain MR images from multiple acquisition scanner types or vendors and a large range of subjects ages, we show that ImUnity: (1) outperforms state-of-the-art methods in terms of quality of images generated using traveling subjects; (2) removes sites or scanner biases while improving patients classification; (3) harmonizes data coming from new sites or scanners without the need for an additional fine-tuning and (4) allows the selection of multiple MR reconstructed images according to the desired applications. Tested here on T1-weighted images, ImUnity could be used to harmonize other types of medical images.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Humanos , Bases de Datos Factuales , Estudios Multicéntricos como Asunto
5.
Europace ; 25(3): 914-921, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36734247

RESUMEN

AIMS: The FLXibility Post-Approval Study collected data on unselected patients implanted with a WATCHMAN FLX in a commercial clinical setting. METHODS AND RESULTS: Patients were implanted with a WATCHMAN FLX per local standard of care, with a subsequent first follow-up visit from 45 to 120 days post-implant and a final follow-up at 1-year post-procedure. A Clinical Event Committee adjudicated all major adverse events and TEE/CT imaging results were adjudicated by a core laboratory. Among 300 patients enrolled at 17 centres in Europe, the mean age was 74.6 ± 8.0 years, mean CHA2DS2-VASc score was 4.3 ± 1.6, and 62.1% were male. The device was successfully implanted in 99.0% (297/300) of patients. The post-implant medication regimen was DAPT for 87.3% (262/300). At first follow-up, core-lab adjudicated complete seal was 88.2% (149/169), 9.5% (16/169) had leak <3 mm, 2.4 (4/169) had leak ≥3 mm to ≤5 mm, and 0% had >5 mm leak. At 1 year, 93.3% (280/300) had final follow-up; 60.5% of patients were on a single antiplatelet medication, 21.4% were on DAPT, 5.6% were on direct oral anticoagulation, and 12.1% were not taking any antiplatelet/anticoagulation medication. Adverse event rates through 1 year were: all-cause death 10.8% (32/295); CV/unexplained death 5.1% (15/295); disabling and non-disabling stroke each 1.0% (3/295, all non-fatal); pericardial effusion requiring surgery or pericardiocentesis 1.0% (3/295); and device-related thrombus 2.4% (7/295). CONCLUSION: The WATCHMAN FLX device had excellent procedural success rates, high LAA seal rates, and low rates of thromboembolic events in everyday clinical practice.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Inhibidores de Agregación Plaquetaria/uso terapéutico , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Resultado del Tratamiento , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Anticoagulantes/efectos adversos , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Transesofágica
6.
JACC Cardiovasc Interv ; 16(6): 643-651, 2023 03 27.
Artículo en Inglés | MEDLINE | ID: mdl-36764917

RESUMEN

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used to guide left atrial appendage closure (LAAC). OBJECTIVES: The aim of this study was to investigate the efficacy and safety of ICE-guided LAAC with the Watchman FLX device. METHODS: The ICE LAA (I Can See Left Atrial Appendage) study was a prospective, multicenter study with independent adjudication of echocardiographic data by a core laboratory and clinical events by a clinical events committee. Patients with atrial fibrillation with CHA2DS2-VASc scores ≥2 and clinical indications for LAAC were eligible. Preplanning with either cardiac computed tomography or transesophageal echocardiography (TEE) within 7 days prior to LAAC was mandatory. Intraprocedural ICE was carried out from the left atrium. The primary outcome was the rate of significant peridevice leaks (>5 mm) at 45-day TEE. RESULTS: A total of 100 patients were enrolled. The mean age was 76 ± 8 years, the mean CHA2DS2-VASc score was 4.0 ± 1.5, and the mean HAS-BLED score was 2.5 ± 0.9. The incidence of the primary outcome of significant peridevice leak (>5 mm) was 0%; all patients evaluated by TEE at 45 days had effective LAAC. All patients received Watchman FLX devices, and technical success was 100%. The number of devices per case was 1.0 ± 0.1. ICE successfully guided the assessment of device release criteria, including device compression (19.2% ± 7.1%; recommended range: 10%-30%). No subject required conversion to TEE. Procedural complications were 4 access-site bleeds. There was no stroke, transient ischemic attack, systemic embolization, pericardial effusion, device embolization, or device-related thrombus during the procedure or 45-day follow-up. CONCLUSIONS: ICE can be used to successfully guide LAAC with the Watchman FLX, with excellent procedural success, a high rate of effective LAAC, and minimal periprocedural complications. (I Can See Left Atrial Appendage [ICELAA] Clinical Study; NCT04196335).


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Anciano , Anciano de 80 o más Años , Estudios Prospectivos , Resultado del Tratamiento , Apéndice Atrial/diagnóstico por imagen , Ecocardiografía , Ecocardiografía Transesofágica , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Cateterismo Cardíaco
7.
J Am Heart Assoc ; 12(4): e026295, 2023 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-36789852

RESUMEN

Background The PINNACLE FLX (Protection Against Embolism for Non-valvular AF [Atrial Fibrillation] Patients: Investigational Device Evaluation of the Watchman FLX LAA [Left Atrial Appendage] Closure Technology) trial evaluated the safety and efficacy of a next-generation left atrial appendage closure device (WATCHMAN FLX; Boston Scientific, Marlborough, MA). At 1 year, the study met the primary end points of safety and anatomical efficacy/appendage closure. This final report of the PINNACLE FLX trial includes the prespecified secondary end point of ischemic stroke or systemic embolism at 2 years, also making it the first report of 2-year outcomes with this next-generation left atrial appendage closure device. Methods and Results Patients with nonvalvular atrial fibrillation with CHA2DS2-VASc score ≥2 (men) or ≥3 (women), with an appropriate rationale for left atrial appendage closure, were enrolled to receive the left atrial appendage closure device at 29 US centers. Adverse events were assessed by an independent clinical events committee, and imaging was assessed by independent core laboratories. Among 395 implanted patients (36% women; mean age, 74 years; CHA2DS2-VASc, 4.2±1.5), the secondary efficacy end point of 2-year ischemic stroke or systemic embolism was met, with an absolute rate of 3.4% (annualized rate, 1.7%) and an upper 1-sided 95% confidence bound of 5.3%, which was superior to the 8.7% performance goal. Two-year rates of adverse events were as follows: 9.3% all-cause mortality, 5.5% cardiovascular death, 3.4% all stroke, and 10.1% major bleeding (Bleeding Academic Research Consortium 3 or 5). There were no additional systemic embolisms, device embolizations, pericardial effusions, or symptomatic device-related thrombi after 1 year. Conclusions The secondary end point of 2-year stroke or systemic embolism was met at 3.4%. In these final results of the PINNACLE FLX trial, the next-generation WATCHMAN FLX device demonstrated favorable safety and efficacy outcomes.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Masculino , Humanos , Femenino , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Resultado del Tratamiento , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Embolia/prevención & control , Embolia/complicaciones , Hemorragia/etiología , Accidente Cerebrovascular Isquémico/etiología , Cateterismo Cardíaco/efectos adversos
8.
J Interv Cardiol ; 2022: 9138403, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35832535

RESUMEN

Objectives: The PROGRESS PVL registry evaluated transcatheter aortic valve implantation (TAVI) in patients treated with ACURATE neo, a supra-annular self-expanding bioprosthetic aortic valve. Background: While clinical outcomes with TAVI are comparable with those achieved with surgery, residual aortic regurgitation (AR) and paravalvular leak (PVL) are common complications. The ACURATE neo valve has a pericardial sealing skirt designed to minimize PVL. Methods: The primary endpoint was the rate of total AR over time, as assessed by a core echocardiographic laboratory. The study enrolled 500 patients (mean age: 81.8 ± 5.1 years; 61% female; mean baseline STS score: 6.0 ± 4.5%) from 22 centers in Europe and Canada; 498 patients were treated with ACURATE neo. Results: The rate of ≥ moderate AR was 4.6% at discharge and 3.1% at 12 months; the rate of ≥ moderate PVL was 4.6% at discharge and 2.6% at 12 months. Paired analyses showed significant improvement in overall PVL between discharge and 12 months (P < 0.001); 64.6% of patients had no change in PVL grade, 24.9% improved, and 10.5% worsened. Patients also exhibited significant improvement in transvalvular gradient (P < 0.001) and effective orifice area (P=0.01). The mortality rate was 2.2% at 30 days and 11.3% at 12 months. The permanent pacemaker implantation (PPI) rate was 10.2% at 30 days and 12.2% at 12 months. Conclusions: Results from PROGRESS PVL support the sustained safety and performance of TAVI with the ACURATE neo valve, showing excellent valve hemodynamics, good clinical outcomes, and significant interindividual improvement in PVL from discharge to 12-month follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
9.
Front Cardiovasc Med ; 9: 861913, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35355966

RESUMEN

The ischemic penumbra is defined as the severely hypoperfused, functionally impaired, at-risk but not yet infarcted tissue that will be progressively recruited into the infarct core. Early reperfusion aims to save the ischemic penumbra by preventing infarct core expansion and is the mainstay of acute ischemic stroke therapy. Intravenous thrombolysis and mechanical thrombectomy for selected patients with large vessel occlusion has been shown to improve functional outcome. Given the varying speed of infarct core progression among individuals, a therapeutic window tailored to each patient has recently been proposed. Recent studies have demonstrated that reperfusion therapies are beneficial in patients with a persistent ischemic penumbra, beyond conventional time windows. As a result, mapping the penumbra has become crucial in emergency settings for guiding personalized therapy. The penumbra was first characterized as an area with a reduced cerebral blood flow, increased oxygen extraction fraction and preserved cerebral metabolic rate of oxygen using positron emission tomography (PET) with radiolabeled O2. Because this imaging method is not feasible in an acute clinical setting, the magnetic resonance imaging (MRI) mismatch between perfusion-weighted imaging and diffusion-weighted imaging, as well as computed tomography perfusion have been proposed as surrogate markers to identify the penumbra in acute ischemic stroke patients. Transversal studies comparing PET and MRI or using longitudinal assessment of a limited sample of patients have been used to define perfusion thresholds. However, in the era of mechanical thrombectomy, these thresholds are debatable. Using various MRI methods, the original penumbra definition has recently gained a significant interest. The aim of this review is to provide an overview of the evolution of the ischemic penumbra imaging methods, including their respective strengths and limitations, as well as to map the current intellectual structure of the field using bibliometric analysis and explore future directions.

10.
Clin Res Cardiol ; 110(12): 1912-1920, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34148125

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become standard treatment for elderly patients with symptomatic severe aortic valve stenosis. The ACURATE neo AS study evaluates 30-day and 1-year clinical and hemodynamic outcomes in patients treated with the ACURATE neo2 valve. METHODS: The primary endpoint of this single-arm multicenter study is 30-day all-cause mortality. Other key endpoints include device performance, echocardiographic measures assessed by an independent core laboratory, and VARC-2 clinical efficacy and safety endpoints through 12 months. RESULTS: The study enrolled 120 patients (mean age 82.1 ± 4.0 years; 67.5% female, mean baseline STS score 4.8 ± 3.8%). The VARC-2 composite safety endpoint at 30 days occurred in 13.3% of patients. All-cause mortality was 3.3% at 30 days and 11.9% at 1 year. The 30-day stroke rate was 2.5% (disabling stroke 1.7%); there were no new strokes between 30 days and 12 months. The rate of permanent pacemaker implantation was 15.0% (18/120) at 30 days and 17.8% (21/120) at 1 year. No patients required re-intervention for valve-related dysfunction and there were no cases of valve thrombosis or endocarditis. Patients demonstrated significant improvement in mean aortic valve gradient (baseline 38.9 ± 13.1 mmHg, 1 year 7.8 ± 3.5 mmHg; P < 0.001 in a paired analysis). In the overall population, paravalvular leak was evaluated at 1 year as none/trace in 60.5%, mild in 37.0%, and moderate in 2.5%; no patients had severe PVL. CONCLUSIONS: One-year outcomes from the ACURATE neo AS study support the safety and performance of TAVI with the ACURATE neo2 valve.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Recuperación de la Función/fisiología , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Diseño de Equipo , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Prótesis Valvulares Cardíacas , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
11.
Neuroimage ; 238: 118237, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34091035

RESUMEN

Magnetic resonance fingerprinting (MRF) is a quantitative MRI (qMRI) framework that provides simultaneous estimates of multiple relaxation parameters as well as metrics of field inhomogeneity in a single acquisition. However, current challenges exist in the forms of (1) scan time; (2) need for custom image reconstruction; (3) large dictionary sizes; (4) long dictionary-matching time. This study aims to introduce a novel streamlined magnetic-resonance fingerprinting (sMRF) framework based on a single-shot echo-planar imaging (EPI) sequence to simultaneously estimate tissue T1, T2, and T2* with integrated B1+ correction. Encouraged by recent work on EPI-based MRF, we developed a method that combines spin-echo EPI with gradient-echo EPI to achieve T2 in addition to T1 and T2* quantification. To this design, we add simultaneous multi-slice (SMS) acceleration to enable full-brain coverage in a few minutes. Moreover, in the parameter-estimation step, we use deep learning to train a deep neural network (DNN) to accelerate the estimation process by orders of magnitude. Notably, due to the high image quality of the EPI scans, the training process can rely simply on Bloch-simulated data. The DNN also removes the need for storing large dictionaries. Phantom scans along with in-vivo multi-slice scans from seven healthy volunteers were acquired with resolutions of 1.1×1.1×3 mm3 and 1.7×1.7×3 mm3, and the results were validated against ground truth measurements. Excellent correspondence was found between our T1, T2, and T2* estimates and results obtained from standard approaches. In the phantom scan, a strong linear relationship (R = 1-1.04, R2>0.96) was found for all parameter estimates, with a particularly high agreement for T2 estimation (R2>0.99). Similar findings are reported for the in-vivo human data for all of our parameter estimates. Incorporation of DNN results in a reduction of parameter estimation time on the order of 1000 x and a reduction in storage requirements on the order of 2500 x while achieving highly similar results as conventional dictionary matching (%differences of 7.4 ± 0.4%, 3.6 ± 0.3% and 6.0 ± 0.4% error in T1, T2, and T2* estimation). Thus, sMRF has the potential to be the method of choice for future MRF studies by providing ease of implementation, fast whole-brain coverage, and ultra-fast T1/T2/T2* estimation.


Asunto(s)
Aprendizaje Profundo , Imagen Eco-Planar/métodos , Neuroimagen/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Método de Montecarlo , Redes Neurales de la Computación , Fantasmas de Imagen
12.
Front Neuroinform ; 14: 594799, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33304261

RESUMEN

This article presents an open source software able to convert, display, and process medical images. It differentiates itself from the existing software by its ability to design complex processing pipelines and to wisely execute them on a large databases. An MP3 pipeline can contain unlimited homemade or ready-made processes and can be carried out with a parallel execution system. As a viewer, MP3 allows display of up to four images together and to draw Regions Of Interest (ROI). Two applications showing the strengths of the software are presented as examples: a preclinical study involving Magnetic Resonance Imaging (MRI) data and a clinical one involving Computed Tomography (CT) images. MP3 is downloadable at https://github.com/nifm-gin/MP3.

13.
Cardiovasc Digit Health J ; 1(2): 89-96, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-35265879

RESUMEN

Background: High blood pressure (BP) is a major risk factor for cardiovascular disease (CVD). Consumption of dark chocolate, which is high in flavonoids that may reduce CVD risk, is an attractive intervention to reduce to BP. Additionally, the use of mobile health (mHealth) technologies (eg, telehealth, smartphones, and wearable devices) can improve outcomes in patients with CVD. Objective: The purpose of this study was to investigate the impact of dark chocolate intake on BP, subject use of mHealth, and integration of mHealth into a clinical trial. Methods: The COCOA-BP (ChOcolate COnsumption And Blood Pressure) study was a prospective, single-center, pre-/postintervention study that enrolled 62 healthy volunteers. The study consisted of 3 phases: smartwatch/smart BP monitor familiarization and washout from chocolate (week 1); control (week 2); and intervention (weeks 3 and 4). During the intervention phase, subjects consumed 50 g of dark chocolate per day. The primary endpoint was change in resting systolic BP between the intervention and control phases. Additional endpoints included device accuracy and correlation with physical activity. Results: Mean resting systolic BP was 116.4 mm Hg before chocolate intake among 62 participants (mean age 37 years; 61% female). After chocolate intake, mean resting systolic BP was 116.0 mm Hg (difference -0.4; P = .69). These findings suggest that 2 weeks of dark chocolate intake did not reduce resting systolic BP. There was poor agreement between mHealth device and standard (nurse-performed) measurements. Conclusion: In this study, short-term dark chocolate intake did not seem to reduce BP. mHealth technology shows great potential for use in clinical studies, but challenges related to device accuracy and compliance need to be addressed.

14.
J Neurosci Methods ; 311: 122-132, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30300699

RESUMEN

BACKGROUND: Recent advancements in simultaneous multi-slice (SMS) imaging techniques have enabled whole-brain resting-state fMRI (rs-fMRI) scanning at sub-second temporal resolution, providing spectral ranges much wider than the typically used range of 0.01-0.1 Hz. However, the advantages of this accelerated acquisition for rs-fMRI have not been evaluated. NEW METHOD: In this study, we used SMS Echo Planar Imaging (EPI) to probe whole-brain functional connectivity with a short repetition time (TR = 350 ms) and compared it with standard EPI with a longer TR of 2000 ms. We determined the effect of scan length and investigated the temporal filtration strategies that optimize results based on metrics of signal-noise separation and test-retest reliability using both seed-based and independent component analysis (ICA). RESULTS: We found that use of either the entire frequency range of 0.01-1.4 Hz or the entire frequency range with the exclusion of typical cardiac and respiratory frequency values tended to provide the best functional connectivity maps. COMPARISON WITH EXISTING METHODS: We found that the SMS-acquired rs-fMRI scans had improved the signal-noise separation, while preserving the same level of test-retest reliability compared to conventional EPI, and enabled the detection of reliable functional connectivity networks with scan times as short as 3 min. CONCLUSIONS: Our findings suggest that whole-brain rs-fMRI studies may benefit from the increased temporal resolution enabled by the SMS-EPI acquisition, leading to drastic scan time reductions, which in turn should enable the more widespread use of rs-fMRI in clinical research protocols.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/diagnóstico por imagen , Imagen Eco-Planar , Imagen por Resonancia Magnética , Adulto , Encéfalo/anatomía & histología , Encéfalo/fisiología , Mapeo Encefálico/instrumentación , Humanos , Procesamiento de Imagen Asistido por Computador , Persona de Mediana Edad , Reproducibilidad de los Resultados , Relación Señal-Ruido
15.
Catheter Cardiovasc Interv ; 93(3): 398-403, 2019 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-30341836

RESUMEN

OBJECTIVES: The goal of this analysis was to evaluate the final 5-year safety and effectiveness of the PROMUS Element platinum-chromium everolimus-eluting stent in unselected patients treated in routine clinical practice. BACKGROUND: The prospective, open-label PROMUS Element™ European Post-Approval Surveillance Study (PE-PROVE) enrolled 1,010 "real-world" patients who received the PROMUS Element stent. Adverse event rates were low at 1-year, and the incidence of stent thrombosis was 0.6%. METHODS: The primary endpoint was target vessel failure (TVF; overall and PE stent-related), a composite of cardiac death, myocardial infarction (MI) related to the target vessel, or target vessel revascularization (TVR) at 1-year post-implantation. Five-year clinical outcomes were evaluated in overall as well as high-risk patient subgroups. RESULTS: The overall 5-year TVF rate was 14.9%, with 7.0% being related to the study stent. Cardiac death, MI and TVR related to the study stent occurred in 0.5%, 3.2%, and 5.7%, respectively. Stent thrombosis through 5-year follow-up was 1.0%. The rates of overall and study stent related TVF were numerically higher in patients with medically treated diabetes, long lesions (≥28 mm), and small diameter vessels (≤2.5 mm) compared to the overall study population. Additionally, favorable stent thrombosis rates through 5 years were reported for the PROMUS Element stent in these high-risk subgroups. CONCLUSIONS: The final 5-year data from the PE-PROVE study demonstrate favorable outcomes and low rates of adverse events with the PE stent when used in "real-world" patients with coronary artery disease.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Cromo , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Platino (Metal) , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/mortalidad , Europa (Continente) , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
16.
Am Heart J ; 205: 110-117, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30218844

RESUMEN

BACKGROUND: While extended dual antiplatelet therapy (DAPT) with aspirin and a platelet (P2Y12) inhibitor after percutaneous coronary intervention (PCI) reduces the risk of stent thrombosis (ST) and myocardial infarction (MI), it also increases bleeding. Newer generation drug-eluting stents with bioabsorbable polymer coatings may reduce thrombotic events and allow abbreviated DAPT in selected patients. The EVOLVE Short DAPT study is designed to evaluate the safety of 3-month DAPT in high bleeding risk subjects treated with the SYNERGY bioabsorbable polymer everolimus-eluting stent. TRIAL DESIGN: EVOLVE Short DAPT is a prospective, single-arm, international study that enrolled 2009 high risk bleeding subjects (defined as age ≥75 years, chronic anticoagulation, major bleeding within 12 months, history of stroke, renal insufficiency/failure, or thrombocytopenia) who underwent PCI with the SYNERGY stent. Subjects presenting with acute MI or complex lesions were excluded. After 3 months treatment with DAPT (except those on anticoagulant in whom aspirin is optional), subjects free from stroke, MI, revascularization or ST will be eligible to discontinue P2Y12 inhibitor, but continue aspirin. Co-primary endpoints assessed between 3-15 months are: i) death/MI compared for non-inferiority with propensity-adjusted historical group receiving 12-month DAPT, and ii) definite/probable ST compared to a performance goal. The secondary endpoint is the rate of bleeding in subjects not receiving chronic anticoagulation compared for superiority against a propensity-adjusted historical control. CONCLUSION: The EVOLVE Short DAPT study will prospectively define the safety of DAPT discontinuation at 3 months in high bleeding risk patients treated with the SYNERGY stent.


Asunto(s)
Aspirina/administración & dosificación , Clopidogrel/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Hemorragia/epidemiología , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Anciano , Brasil/epidemiología , Enfermedad de la Arteria Coronaria/complicaciones , Relación Dosis-Respuesta a Droga , Quimioterapia Combinada , Europa (Continente)/epidemiología , Femenino , Hemorragia/complicaciones , Humanos , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento , Estados Unidos/epidemiología
17.
Brain Connect ; 8(6): 362-370, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29886781

RESUMEN

In resting-state functional MRI (rs-fMRI), functional networks are assessed utilizing the temporal correlation between spontaneous blood oxygen level-dependent signal fluctuations of spatially remote brain regions. Recently, several groups have shown that temporal shifts are present in rs-fMRI maps in patients with cerebrovascular disease due to spatial differences in arterial arrival times, and that this can be exploited to map arrival times in the brain. This suggests that rs-fMRI connectivity mapping may be similarly sensitive to such temporal shifts, and that standard rs-fMRI analysis methods may fail to identify functional connectivity networks. To investigate this, we studied the default mode network (DMN) in Moyamoya disease patients and compared it with normal healthy volunteers. Our results show that using standard independent component analysis (ICA) and seed-based approaches, arterial arrival delays lead to inaccurate incomplete characterization of functional connectivity within the DMN in Moyamoya disease patients. Furthermore, we propose two techniques to correct these errors, for seed-based and ICA methods, respectively. Using these methods, we demonstrate that it is possible to mitigate the deleterious effects of arterial arrival time on the assessment of functional connectivity of the DMN. As these corrections have not been applied to the vast majority of >200 prior rs-fMRI studies in patients with cerebrovascular disease, we suggest that they be interpreted with great caution. Correction methods should be applied in any rs-fMRI connectivity study of subjects expected to have abnormally delayed arterial arrival times.


Asunto(s)
Mapeo Encefálico , Imagen por Resonancia Magnética , Enfermedad de Moyamoya/diagnóstico por imagen , Descanso , Adulto , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Modelos Neurológicos , Oxígeno/sangre , Análisis de Componente Principal , Factores de Tiempo
18.
EuroIntervention ; 13(17): 2047-2050, 2018 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-28923786

RESUMEN

AIMS: Long-term data on bioabsorbable polymer-coated everolimus-eluting stents (BP-EES) are limited. The EVOLVE trial compared the safety and efficacy of two dose formulations of the SYNERGY BP-EES with the permanent polymer-coated PROMUS Element EES (PE). METHODS AND RESULTS: The EVOLVE study was a prospective, multicentre, non-inferiority trial that randomised 291 patients with de novo coronary lesions (length: ≤28 mm; diameter: ≥2.25 to ≤3.5 mm) to receive PE (n=98), SYNERGY (n=94), or SYNERGY half-dose (n=99). At five years, there were no significant differences in the rates of TLF or individual components between groups. TLR rates trended lower in both SYNERGY arms than in the PE arm (TLR: 1.1% SYNERGY and 1.0% SYNERGY half-dose vs. 6.1% PE; p=0.07 and p=0.06, respectively). TVR was numerically lower in the SYNERGY arms compared to the PE arm (TVR: 3.3% SYNERGY and 4.2% SYNERGY half-dose vs. 10.2% PE; p=0.06 and p=0.11, respectively). No incidence of stent thrombosis was reported in any arm up to five years. CONCLUSIONS: The EVOLVE trial represents the longest-term follow-up of the SYNERGY stent available to date, demonstrating its continued safety and efficacy for the treatment of selected de novo atherosclerotic lesions up to five years.


Asunto(s)
Implantes Absorbibles/efectos adversos , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Everolimus/farmacología , Efectos Adversos a Largo Plazo , Intervención Coronaria Percutánea , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/etiología , Stents Liberadores de Fármacos , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/farmacología , Efectos Adversos a Largo Plazo/diagnóstico , Efectos Adversos a Largo Plazo/epidemiología , Efectos Adversos a Largo Plazo/etiología , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Polímeros/farmacología , Diseño de Prótesis , Resultado del Tratamiento
19.
Am Heart J ; 190: 76-85, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28760216

RESUMEN

This white paper provides a summary of presentations, discussions and conclusions of a Thinktank entitled "The Role of Endpoint Adjudication in Medical Device Clinical Trials". The think tank was cosponsored by the Cardiac Safety Research Committee, MDEpiNet and the US Food and Drug Administration (FDA) and was convened at the FDA's White Oak headquarters on March 11, 2016. Attention was focused on tailoring best practices for evaluation of endpoints in medical device clinical trials, practical issues in endpoint adjudication of therapeutic, diagnostic, biomarker and drug-device combinations, and the role of adjudication in regulatory and reimbursement issues throughout the device lifecycle. Attendees included representatives from medical device companies, the FDA, Centers for Medicare and Medicaid Services (CMS), end point adjudication specialist groups, clinical research organizations, and active, academically based adjudicators. The manuscript presents recommendations from the think tank regarding (1) rationale for when adjudication is appropriate, (2) best practices establishment and operation of a medical device adjudication committee and (3) the role of endpoint adjudication for post market evaluation in the emerging era of real world evidence.


Asunto(s)
Investigación Biomédica , Enfermedades Cardiovasculares/terapia , Determinación de Punto Final/normas , Equipos y Suministros , Vigilancia de Productos Comercializados/métodos , Humanos , Estados Unidos , United States Food and Drug Administration
20.
J Magn Reson Imaging ; 46(3): 704-714, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28306210

RESUMEN

PURPOSE: To simultaneously assess reproducibility of three MRI transverse relaxation parameters ( R2', R2*, and R2 ) for brain tissue oxygenation mapping and to assess changes in these parameters with inhalation of gases that increase and decrease oxygenation, to identify the most sensitive parameter for imaging brain oxygenation. MATERIALS AND METHODS: Forty-eight healthy subjects (25 male, ages 35 ± 8 years) were scanned at 3.0 Tesla, each with one of four gases (mildly and strongly hypercapnic and hypoxic) administered in a challenge paradigm, using a gas delivery setup designed for patient use. Cerebral blood flow mapping with arterial spin labeling, and simultaneous R2', R2*, and R2 mapping with gradient-echo sampling of free induction decay and echo (GESFIDE) were performed. Reproducibility in air and gas-induced changes were evaluated using nonparametric analysis with correction for multiple comparisons. RESULTS: Our gas delivery setup achieved stable gas challenges as shown by physiological monitoring. Test-retest variability of R2', R2*, and R2 were found to be 0.24 s-1 (8.6% of mean), 0.24 s-1 (1.3% of mean), and 0.15 s-1 (1.0% of mean), respectively. Strong hypoxia produced the most conclusive oxygenation-driven relaxation change, inducing increases in R2' (25 ± 13%, P = 0.03), R2* (5 ± 2%, P = 0.02), and R2 (2 ± 2%, NS). CONCLUSION: We benchmarked the intra-scan test-retest variability in GESFIDE-based transverse relaxation rate mapping. Using a reliable framework for gas challenge paradigms, we recommend strong hypoxia for validating oxygenation mapping methods, and the use of tissue R2' change, instead of R2* or R2 , as a metric for studying brain tissue oxygenation using transverse relaxation methods. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:704-714.


Asunto(s)
Encéfalo/metabolismo , Hipercapnia/metabolismo , Hipoxia/metabolismo , Imagen por Resonancia Magnética/métodos , Oxígeno/metabolismo , Adulto , Benchmarking , Encéfalo/diagnóstico por imagen , Mapeo Encefálico/métodos , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Procesamiento de Imagen Asistido por Computador , Masculino , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA