Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Analyst ; 149(5): 1447-1454, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38197456

RESUMEN

Ventilator-associated pneumonia (VAP) is a prevalent disease caused by microbial infection, resulting in significant morbidity and mortality within the intensive care unit (ICU). The rapid and accurate identification of pathogenic bacteria causing VAP can assist clinicians in formulating timely treatment plans. In this study, we attempted to differentiate bacterial species in VAP by utilizing the volatile organic compounds (VOCs) released by pathogens. We cultured 6 common bacteria in VAP in vitro, including Acinetobacter baumannii, Enterobacter cloacae, Escherichia coli, Pseudomonas aeruginosa, Stenotrophomonas maltophilia, and Staphylococcus aureus, which covered most cases of VAP infection in clinic. After the VOCs released by bacteria were collected in sampling bags, they were quantitatively detected by a proton transfer reaction-mass spectrometry (PTR-MS), and the characteristic ions were qualitatively analyzed through a fast gas chromatography-proton transfer reaction-mass spectrometry (FGC-PTR-MS). After conducting principal component analysis (PCA) and analysis of similarities (ANOSIM), we discovered that the VOCs released by 6 bacteria exhibited differentiation following 3 h of quantitative cultivation in vitro. Additionally, we further investigated the variations in the types and concentrations of bacterial VOCs. The results showed that by utilizing the differences in types of VOCs, 6 bacteria could be classified into 5 sets, except for A. baumannii and E. cloacae which were indistinguishable. Furthermore, we observed significant variations in the concentration ratio of acetaldehyde and methyl mercaptan released by A. baumannii and E. cloacae. In conclusion, the VOCs released by bacteria could effectively differentiate the 6 pathogens commonly associated with VAP, which was expected to assist doctors in formulating treatment plans in time and improve the survival rate of patients.


Asunto(s)
Neumonía Asociada al Ventilador , Compuestos Orgánicos Volátiles , Humanos , Compuestos Orgánicos Volátiles/análisis , Protones , Neumonía Asociada al Ventilador/diagnóstico , Neumonía Asociada al Ventilador/microbiología , Espectrometría de Masas/métodos , Bacterias
2.
Anal Chem ; 95(30): 11375-11382, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37392185

RESUMEN

The investigation of volatile organic compounds (VOCs) in human metabolites has been a topic of interest as it holds the potential for the development of non-invasive technologies to screen for organ lesions in vivo. However, it remains unclear whether VOCs differ among healthy organs. Consequently, a study was conducted to analyze VOCs in ex vivo organ tissues obtained from 16 Wistar rats, comprising 12 different organs. The VOCs released from each organ tissue were detected by the headspace-solid phase microextraction-gas chromatography-mass spectrometry technique. In the untargeted analysis of 147 chromatographic peaks, the differential volatiles of rat organs were explored based on the Mann-Whitney U test and fold change (FC > 2.0) compared with other organs. It was found that there were differential VOCs in seven organs. A discussion on the possible metabolic pathways and related biomarkers of organ differential VOCs was conducted. Based on the orthogonal partial least squares discriminant analysis and receiver operating characteristic curve, we found that differential VOCs in the liver, cecum, spleen, and kidney can be used as the unique identification of the corresponding organ. In this study, differential VOCs of organs in rats were systematically reported for the first time. Profiles of VOCs produced by healthy organs can serve as a reference or baseline that may indicate the presence of disease or abnormalities in the organ's function. Differential VOCs can be used as the fingerprint of organs, and future integration with metabolic research may contribute to the development of healthcare.

3.
Talanta ; 256: 124265, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36669369

RESUMEN

Urinary acetone in urine is produced from fat metabolism in human body, which can be accelerated in diabetic patients because of insufficient utilization and storage of glucose. In this study, we tried to develop a novel diagnosis method of type 2 diabetes (T2D) through sniffing urinary acetone by a proton transfer reaction mass spectrometry (PTR-MS). A total of 180 T2D patients and 180 healthy volunteers were recruited from three hospitals for multicenter study. Urine samples were collected in the morning when donators were fasting and stored in glass bottles. Acetone in the headspace of these bottles was qualitatively and quantitatively detected by the PTR-MS in 8 h. Using a threshold of 690.1 ppbv, a diagnostic model was established using urinary acetone with an accuracy of 81.3% (sensitivity: 73.3%, specificity: 89.3%) in hospital Ⅰ. In the verification studies, the accuracies were 92.5% (sensitivity: 88.7%, specificity: 96.2%) in hospital Ⅱ and 83.7% (sensitivity: 76.9%, specificity: 90.4%) in hospital Ⅲ, respectively. The accuracy is comparable to that of clinically used diagnosis methods, fasting plasma glucose (FPG), oral glucose tolerance test (OGTT), and glycosylated hemoglobin A1c (HbA1c) test. The sensitivity for 35 newly diagnosed patients was 85.7%. The newly developed technology is completely non-invasive and much more rapid than clinical FPG, OGTT, and HbA1c tests. It has a promising prospect in clinical use. But the applicability in different human races still need more validations.


Asunto(s)
Acetona , Diabetes Mellitus Tipo 2 , Humanos , Acetona/análisis , Acetona/orina , Glucemia/análisis , Diabetes Mellitus Tipo 2/diagnóstico , Hemoglobina Glucada , Espectrometría de Masas , Protones , Sensibilidad y Especificidad
4.
Open Life Sci ; 18(1): 20220613, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38162391

RESUMEN

Apple (Malus domestica, Borkh.) is one of the four largest fruits in the world. Freezing damage during the flowering period of apples is one of the main factors leading to the reduction or even extinction of apple production. Molecular breeding of hardy apples is a good solution to these problems. However, the current screening of cold tolerance genes still needs to be resolved. Therefore, in this article, the transcriptome detection and cold tolerance gene screening during the cold adaptation process of apple were studied in order to obtain potential cold-resistant genes. Herein, two high-quality apple tree species (Malus robusta Rehd and M. domestica) were used for cold adaptation experiments and studied under different low-temperature stress conditions (0, -2 and -4°C). The antioxidant levels of two apple flower tissues were tested, and the transcriptome of the flowers after cold culture was tested by next-generation sequencing technology. Antioxidant test results show that the elimination of peroxides in M. robusta Rehd and the adjustment of the expression of antioxidant enzymes promote the cold resistance of this variety of apples. Functional enrichment found that the expression of enzyme activity, cell wall and cell membrane structure, glucose metabolism/gluconeogenesis, and signal transmission are the main biological processes that affect the differences in the cold resistance characteristics of the two apples. In addition, three potential cold-resistant genes AtERF4, RuBisCO activase 1, and an unknown gene (ID: MD09G1075000) were screened. In this study, three potential cold-resistant genes (AtERF4, RuBisCO activase 1, and an unknown gene [ID: MD09G1075000]) and three cold-repressed differential genes (AtDTX29, XTH1, and TLP) were screened.

5.
Anal Chem ; 94(39): 13368-13376, 2022 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-36150177

RESUMEN

Sensitivity enhancement in proton transfer reaction mass spectrometry (PTR-MS) is an important development direction. We developed a novel drift tube called a focusing quadrupole ion funnel (FQ-IF) for use in PTR-MS to improve the sensitivity. The FQ-IF consists of 20 layers of stainless steel electrodes, and each layer has 4 quarter rings. The first 6 layers have a constant inner hole diameter of 22 mm; the latter 14 layers taper the inner diameter down to 8 mm. The FQ-IF drift tube can also operate in the direct current (DC) mode (similar to a conventional drift tube) and ion funnel (IF) mode (similar to a conventional ion funnel drift tube) by changing the voltage loading method. The simulation results show that the transmission efficiency of the FQ-IF is significantly improved compared to that of the other two modes. Further experiments show that the product ions of limonene tend to convert into smaller m/z fragment ions at higher voltages for the DC and IF modes. However, unlike the DC and IF modes, the distribution of product ions is stable at higher voltages for the FQ-IF. In other words, a higher RF voltage for the FQ-IF will not increase the collision energy of ions. In addition, the improvements in sensitivity for the FQ-IF range from 13.8 to 87.9 times compared to the DC mode and from 1.7 to 4.8 times compared to the IF mode for the 12 test compounds. The improvements in the limit of detection (LOD) for the FQ-IF range from 2.7 to 35.7 times compared to the DC mode. The FQ-IF provides a valuable reference for improving the sensitivity of PTR-MS and other mass spectrometers.


Asunto(s)
Protones , Acero Inoxidable , Iones , Limoneno , Espectrometría de Masas/métodos
6.
Anal Bioanal Chem ; 414(26): 7647-7658, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36018334

RESUMEN

Exhaled volatile organic compounds (VOCs) have been widely applied for the study of disease biomarkers. Oral exhalation and nasal exhalation are two of the most common sampling methods. However, VOCs released from food residues and bacteria in the mouth or upper respiratory tract were also sampled and usually mistaken as that produced from body metabolism. In this study, exhalation from deep airway was first directly collected through intubation sampling and analyzed. The exhalation samples of 35 subjects were collected through a catheter, which was inserted into the trachea or bronchus through the mouth and upper respiratory tract. Then, the VOCs in these samples were detected by proton transfer reaction mass spectrometry (PTR-MS). In addition, fast gas chromatography proton transfer reaction mass spectrometry (FGC-PTR-MS) was used to further determine the VOCs with the same mass-to-charge ratios. The results showed that there was methanol, acetonitrile, ethanol, methyl mercaptan, acetone, isoprene, and phenol in the deep airway. Compared with that in oral exhalation, ethanol, methyl mercaptan, and phenol had lower concentrations. In detail, the median concentrations of ethanol, methyl mercaptan, and phenol were 7.3, 0.6, and 23.9 ppbv, while those in the oral exhalation were 80.0, 5.1, and 71.3 ppbv, respectively, which meant the three VOCs mainly originated from the food residues and bacteria in the mouth or upper respiratory tract, rather than body metabolism. The research results in our study can provide references for expiratory VOC research based on oral and nasal exhalation samplings, which are more feasible in clinical practice.


Asunto(s)
Compuestos Orgánicos Volátiles , Humanos , Compuestos Orgánicos Volátiles/análisis , Pruebas Respiratorias/métodos , Acetona , Protones , Metanol/análisis , Espiración , Pulmón/química , Biomarcadores/análisis , Etanol/análisis , Acetonitrilos , Compuestos de Sulfhidrilo/análisis , Fenoles/análisis , Intubación Intratraqueal
7.
Front Microbiol ; 13: 956840, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36003931

RESUMEN

Intercropping is an important soil management practice for increasing orchard productivity and land-use efficiency because it has beneficial effects on soil microbial communities and soil properties. However, there is relatively little information available regarding the effects of different crops/grasses on soil microbial communities and soil metabolic products in apple orchards in arid and semi-arid regions. In this study, we showed the microbial communities of apple, intercropping plants, and sandy waste soil, using the third-generation PacBio SMRT long-read sequencing technology. Our results also revealed that the microbial communities and soil metabolic properties differed significantly between apple and the sandy waste soil and the intercropping plants. Intercropping could significantly enrich diverse microbial species, microbial nitrogen, and microbial carbon of soil. Moreover, intercropping with licorice showed better effects in recruiting beneficial microbes, compared to grass and pepper, significantly enriching species belonging to some well-known taxa with beneficial effects, including Bacillus, Ensifer, Paenibacillus, Rhizobium, and Sphingomonas. Thus, intercropping with licorice may improve apple tree growth and disease resistance. Furthermore, Bradyrhizobium and Rubrobacter were included among the keystone taxa of apple, whereas Bacillus, Chitinophaga, Stenotrophobacter, Rubrobacter, and Luteimonas were the keystone taxa of the intercropping plants. The results of our study suggest that intercropping with licorice is a viable option for increasing apple orchard productivity.

8.
J Chromatogr A ; 1676: 463210, 2022 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-35700573

RESUMEN

Butanol is a common organic solvent used in latex paint, and one of its isomers, tert-butanol, is toxic and can cause potential harm to the human body. Therefore, it is of great significance to develop a qualitative and quantitative detection method for butanol isomers. In this study, we combined the advantages of rapid detection of proton transfer reaction mass spectrometry (PTR-MS) with the separation and qualitative capabilities of gas chromatography-mass spectrometry (GC-MS) to achieve the detection of isomers, building a fast gas chromatography proton transfer reaction mass spectrometry (FastGC-PTR-MS) equipment. Firstly, the developed technology was optimized using standard samples of several common volatile organic compounds. The retention times of acetonitrile, acetone, and alcohols were less than 50 s, and the retention times of the benzene series were less than 110 s, on the premise that these isomers could be basically separated (resolution R > 1.0). Compared with a commercial GC-MS equipment, the detection times were shortened by 5-6 times and 2-4 times, respectively. Then the FastGC-PTR-MS was applied to detect the isomers of butanol in latex paint. The results showed that the headspace of brand D latex paint mainly contained five substances: tert-butanol, n-butanol, acetaldehyde, methanol, and acetone. Tert-butanol and n-butanol could be completely separated (R > 1.5). The concentration of tert-butanol was 4.41 ppmv, far below the 100 ppmv maximum allowable workplace concentration. The developed FastGC-PTR-MS can be used for rapid qualitative and quantitative detection of butanol isomers in latex paint. The new equipment has the potential to play an important role in indoor environmental safety applications.


Asunto(s)
Butanoles , Látex , Pintura , Butanoles/análisis , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Látex/química , Pintura/análisis
9.
Anal Chem ; 94(20): 7174-7180, 2022 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-35536750

RESUMEN

We have developed and characterized a novel drift tube called the direct current-ion funnel (DC-ion funnel) drift tube, consisting of 20 traditional ring electrodes and 5 new DC-focusing electrodes (DC-FEs) for use in proton transfer reaction mass spectrometry (PTR-MS). Ion trajectory simulations demonstrate the ion focusing effect of the DC-FE and DC-ion funnel drift tube. Further comparative experiments show that the PTR-MS with the novel DC-ion funnel drift tube has a higher sensitivity (3.8-7.3 times for the volatile organic compounds considered in this work) than the PTR-MS with a traditional drift tube. Different from conventional radiofrequency (rf) focusing methods, the DC-ion funnel drift tube can realize ion focusing with only a DC electric field and no additional rf power supply, which makes it especially suitable for instruments requiring miniaturization and low power consumption to improve detection sensitivity. In addition, the DC-ion funnel drift tube can easily be coupled to other types of mass spectrometers to increase their detection sensitivity.


Asunto(s)
Protones , Compuestos Orgánicos Volátiles , Electricidad , Electrodos , Espectrometría de Masas/métodos , Compuestos Orgánicos Volátiles/análisis
10.
J Zhejiang Univ Sci B ; 23(2): 153-157, 2022 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-35187888

RESUMEN

Radiotherapy uses high-energy X-rays or other particles to destroy cancer cells and medical practitioners have used this approach extensively for cancer treatment (Hachadorian et al., 2020). However, it is accompanied by risks because it seriously harms normal cells while killing cancer cells. The side effects can lower cancer patients' quality of life and are very unpredictable due to individual differences (Bentzen, 2006). Therefore, it is essential to assess a patient's body damage after radiotherapy to formulate an individualized recovery treatment plan. Exhaled volatile organic compounds (VOCs) can be changed by radiotherapy and thus used for medical diagnosis (Vaks et al., 2012). During treatment, high-energy X-rays can induce apoptosis; meanwhile, cell membranes are damaged due to lipid peroxidation, converting unsaturated fatty acids into volatile metabolites (Losada-Barreiro and Bravo-Díaz, 2017). At the same time, radiotherapy oxidizes water, resulting in reactive oxygen species (ROS) that can increase the epithelial permeability of pulmonary alveoli, enabling the respiratory system to exhale volatile metabolites (Davidovich et al., 2013; Popa et al., 2020). These exhaled VOCs can be used to monitor body damage caused by radiotherapy.


Asunto(s)
Compuestos Orgánicos Volátiles , Pruebas Respiratorias/métodos , Espiración , Humanos , Calidad de Vida , Sistema Respiratorio/química , Compuestos Orgánicos Volátiles/análisis
11.
Anal Bioanal Chem ; 414(6): 2275-2284, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34982180

RESUMEN

By means of glass bottle sampling followed by solid-phase microextraction gas chromatography-mass spectrometry (SPME-GC-MS) technique, the change characteristics of volatile organic compounds (VOCs) in breaths, between before gargling and after gargling, were investigated, respectively, in 41 healthy subjects and 50 esophageal cancer patients. Using an untargeted strategy, 143 VOC chromatographic peaks were enrolled in the statistical analysis. Based on the orthogonal partial least squares discriminant analysis (OPLS-DA), the VOC variations after gargling for each breath test group were obtained according to the combined criteria of variable importance in projection (VIP > 1.5), Wilcoxon signed-rank test (P < 0.05), and fold change (FC > 2.0). When gargled, the levels of indole, phenol, 1-propanol, and p-cresol in the breath of healthy people decreased; meanwhile, for esophageal cancer patients, the declined VOCs in breath were indole, phenol, dimethyl disulfide, and p-cresol. Particularly, these substances were previously reported as breath biomarkers in some diseases such as esophageal, gastric, thyroid, breast, oral, and lung cancers, as well as certain non-cancer disorders. The present work indicates that expiratory VOCs involve the prominent oral cavity source, and in the breath biomarkers study, the potential impact that originates from oral volatiles should be considered. In view of the present results, it is also proposed that gargle pretreatment could eliminate possible interference from the oral cavity VOCs that might benefit breath biomarker investigation. Gargle pretreatment helps to distinguish oral-source VOCs and control their potential impact on breath biomarkers.


Asunto(s)
Compuestos Orgánicos Volátiles , Biomarcadores/análisis , Pruebas Respiratorias/métodos , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Microextracción en Fase Sólida/métodos , Compuestos Orgánicos Volátiles/análisis
12.
Anal Bioanal Chem ; 413(16): 4237-4246, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33948704

RESUMEN

Methamphetamine (MA) is a highly addictive and illegal psychostimulant drug and is currently one of the most commonly abused illicit drugs in the world. The on-site rapid detection of trace amounts of MA and screening illicit drugs in clandestine laboratories is important for drug enforcement agencies and the forensic community in general. However, detecting methamphetamine in the presence of nicotine and cigarette smoke by ion mobility spectrometry faces difficulty due to the overlapped spectral peaks of methamphetamine and nicotine. In this work, a new method was developed to detect MA using pyridine as a dopant in the presence of nicotine by a homemade ion mobility spectrometry. The reduced mobilities of MA and nicotine were measured under the temperatures of the drift tube from 40 to 120 °C and doping with pyridine. The result shows that the temperature of 100 °C is beneficial to resolve the two substances. The concentration of doped pyridine is optimized to be 18 ppm. In this doped experiment, the reaction rate of nicotine is higher than that of MA by measuring the instrumental responses of MA and nicotine. No matter how high the nicotine content is, the interference of nicotine can be eliminated in the detection of MA doped with pyridine. This method is also successfully applied for the determination of MA and nicotine simultaneously in real saliva samples. The limit of detection of MA was measured to be about 0.5 ng/µL. The promising results in this work provide an effective method for on-site detection of MA.


Asunto(s)
Estimulantes del Sistema Nervioso Central/análisis , Metanfetamina/análisis , Nicotina/análisis , Saliva/química , Humanos , Drogas Ilícitas/análisis , Espectrometría de Movilidad Iónica/métodos , Límite de Detección , Piridinas/química , Detección de Abuso de Sustancias/métodos
13.
Environ Pollut ; 265(Pt B): 114628, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32806440

RESUMEN

Volatile organic compounds (VOCs) are important precursors of ozone (O3) and secondary organic aerosols (SOAs). Tracing VOC pollution sources is important for controlling VOC emissions and reducing O3 and SOAs. We built a novel mobile proton transfer reaction mass spectrometry (M-PTR-MS) instrument to image the distribution of VOCs and trace their emission sources in cities and industrial parks. The M-PTR-MS is composed of a vibration-resistant proton transfer reaction mass spectrometry (PTR-MS) with a global positioning system receiver, modified box vehicle, and geographic information system (GIS) software. The PTR-MS, mounted on a vehicle, sends VOC data and vehicle position information to the GIS software. These data are used to image the space distribution of VOCs in real time while the vehicle platform is in motion and the VOC sources are precisely traced using the GIS. The spatial data resolution of the M-PTR-MS is typically 0.8 m. The limits of detection, sensitivity, and repeatability of the M-PTR-MS are 43.5 ppt, 347 counts ppb-1, and 2.4% (RSD, n = 5), respectively. The intensity of reagent ions is stable over 8 h (RSD = 0.45%). Compared with commercial PTR-MS equipment, the M-PTR-MS demonstrated high consistency, with a correlation coefficient of 92.665%. Several field experiments were conducted in China using the M-PTR-MS. In one field experiment, the VOC distribution along three different routes was surveyed; the navigation monitoring lasted 1.8 h over a distance of 26.7 km at an average speed of 15 km h-1. The VOC sources in an industrial park were identified by analyzing the components near different factories. The main species from a VOC source in an underground garage was related to paint. The M-PTR-MS instrument can be used by environmental protection agencies to trace VOC pollution sources in real time, and by researchers to survey VOC emissions in regions of concern.


Asunto(s)
Compuestos Orgánicos Volátiles , China , Ciudades , Espectrometría de Masas , Protones
14.
Anal Bioanal Chem ; 412(22): 5397-5408, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32564118

RESUMEN

In order to find out cancer markers in human breath, in vitro cell culture is often used to study the characteristic volatile organic compounds (VOCs). In the cell culture process, disposable vessels are frequently adopted. However, these vessels are normally made of plastic, and they have the possibility to release some VOCs, which may interfere with the cell-specific volatiles and even can result in an incorrect conclusion. In this study, by using glass cell culture flasks as control, the headspace solid-phase microextraction gas chromatography mass spectrometry (HS-SPME-GC-MS) analyses of the VOCs in plastic cell culture flasks were systematically carried out for the first time. A total of 35 VOCs were detected in five brands of flasks. In each flask, there were between 13 and 25 volatile compounds. Furthermore, the components and packaging bag of each flask were also sampled and analyzed by HS-SPME-GC-MS. The results show that the flask cap, septum, flask body, and packaging bag exhibit respectively different volatile behaviors. The former two parts release the most volatiles which have obvious contributions to the headspace gases in the flasks, while the flask body mainly liberates styrene. For different flasks packed within the same bag, the headspace analyses show that their residual VOCs are inconsistent with each other. Moreover, the residual VOCs in the same flask are variable in three consecutive days. These results indicate that the multiple flasks in parallel cell culture experiments, or the same flask with different cell culture durations, will produce an indelible disturbance to the cell-specific VOCs. In addition, among the 35 VOCs detectable in five brands of empty plastic flasks, 15 VOCs were previously reported as characteristic VOCs from lung cancer, melanoma, cervical cancer cells, or normal cells. This is an alert that, when using plastic flasks, it must be careful to treat the possible interference from the background VOCs in the flasks. This study demonstrates that the cell culture tool needs to be standardized, and the clean glass or metal vessels are strongly recommended for usage when studying cell volatile biomarkers. Graphical abstract.


Asunto(s)
Biomarcadores de Tumor/análisis , Plásticos , Compuestos Orgánicos Volátiles/análisis , Pruebas Respiratorias , Técnicas de Cultivo de Célula , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Neoplasias/diagnóstico , Microextracción en Fase Sólida/métodos
15.
Anal Bioanal Chem ; 412(15): 3663-3671, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32333078

RESUMEN

Breath analysis is a promising method for metabolomics studies and clinical diagnosis, as it enables the observation of metabolites in a convenient and noninvasive way. In this work, an atmospheric pressure photoionization (APPI) source was modified for online analysis of exhaled breath by coupling with quadrupole time-of-flight mass spectrometry (QTOFMS). Three parameters, namely, the capillary voltage, the sampling flow and the curtain gas flow of the APPI source, were optimized. Five healthy volunteers, three males and two females, were enrolled to test the performance of modified APPI-QTOFMS by analyzing their exhaled breath. A total of 21 compounds were tentatively identified, and four metabolites, namely, dimethyl selenoxide, δ-valerolactam, hydroxymandelic acid and palmitic amide were detected in the exhaled breath for the first time. The result shows that modified APPI-QTOFMS can be used for the online study of exhaled breath. Graphical abstract.


Asunto(s)
Pruebas Respiratorias/instrumentación , Espectrometría de Masas/instrumentación , Presión Atmosférica , Diseño de Equipo , Espiración , Femenino , Humanos , Lactamas/análisis , Masculino , Metabolómica/instrumentación , Compuestos de Organoselenio/análisis , Óxidos/análisis
16.
RSC Adv ; 10(49): 29441-29449, 2020 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-35521110

RESUMEN

Electron adsorption ionization ion mobility spectrometry can be used to detect halogen-containing volatile organic compounds with high sensitivity. However, this traditional electron attachment detection method cannot distinguish between volatile organic compounds containing the same halogen. For different organic compounds containing the same halogen, the product ions formed by the dissociation electron attachment process are the same. In this article, we propose a novel negative corona discharge ion mobility spectrometry method to distinguish between and detect halogenated alkanes containing the same halogen according to the different electron attachment rates and reaction kinetic parameters of the different halogenated alkanes. Although these halogenated alkanes, which contain the same halogen, produce the same type of ions through the electron attachment process, their electron attachment rates are different from each other. In this work, the kinetic information is used as the fingerprint information for the tested samples to distinguish different halogenated alkanes. Five halogenated alkanes were successfully detected using this method. The results show that the method based on the electron attachment rate constant is feasible for the determination of halogenated alkanes containing the same halogen.

17.
J Anal Methods Chem ; 2019: 1417035, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31772814

RESUMEN

Direct analysis and identification of biological tissue is significant for clinical applications. In this study, porcine liver and kidney have been analyzed using laser ablation electrospray ionization time-of-flight mass spectrometry (LAESI-TOFMS). This method showed good reproducibility for the same types of tissue and is capable of distinguishing different tissue species. The margin assessment was also performed using porcine renal tissue, and the response time was less than 6 s. Furthermore, human hepatocarcinoma tissue and normal tissue were identified using this method. Our results indicate that LAESI-TOFMS is a feasible approach for direct identification of tumor tissue and potential for assessment of the resection margin.

18.
Anal Sci ; 35(10): 1155-1159, 2019 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-31178549

RESUMEN

Nitrogen-containing compounds are important components in human breath. However, their origins have not yet been clearly understood. In this study, a modified electrospray ionization (ESI) source coupling with quadrupole time-of-flight mass spectrometry has been used for breath analysis. Fourteen nitrogen-containing compounds were identified in mouth-exhaled breath, and 10 of them were from the oral cavity and oropharynx. Moreover, 8 of these nitrogen-containing compounds were recognized as endogenous metabolites. This result provides important clues for exploring the biological origins of these nitrogen-containing compounds. Observation of the ion suppression phenomenon also indicates that breath analysis should be carried out after clearing of the oral cavity and oropharynx, or directly through nose-breathing to eliminate the influence of those nitrogen-containing compounds from the oral cavity.


Asunto(s)
Pruebas Respiratorias/métodos , Espiración , Boca , Compuestos de Nitrógeno/análisis , Espectrometría de Masa por Ionización de Electrospray , Humanos , Compuestos de Nitrógeno/química
19.
Anal Biochem ; 581: 113344, 2019 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-31233710

RESUMEN

Breath testing is a noninvasive method with potential for diagnosing cancers and has been regarded as one of the research hotspots in metabolomics. In the conventional breath sampling process, however, degradation of exhaled metabolites and introduction of impurities from sampling bags or tubes limit the development of breath research. To solve this problem, we previously developed an on-line breath sampling system, which can directly deliver exhaled gases from the mouth to the proton transfer reaction mass spectrometry (PTR-MS) breath analysis instrument. To establish a standard expiratory method for this system, four parameters that may affect the concentrations of exhaled volatile organic compounds (VOCs) were studied. We found inhaled gas volume, breath holding time, mouth rinsing, and ambient air all affected the exhaled VOCs. In particular, the breath holding time and mouth rinsing significantly affected the VOCs which originate from the oral cavity. Therefore, these four parameters should be taken into account in future on-line breath testing.


Asunto(s)
Espectrometría de Masas , Protones , Compuestos Orgánicos Volátiles/análisis , Pruebas Respiratorias , Femenino , Humanos , Masculino
20.
J Environ Radioact ; 203: 117-124, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30897483

RESUMEN

This study evaluated U(VI) biosorption properties by the resistant bacterium, Bacillus amyloliquefaciens, which was isolated from the soils with residual radionuclides. The effect of biosorption factors (uptake time, pH, ionic concentration, biosorbent dosage and temperature) on U(VI) removal was determined by batch experiments. The uptake processes were characterized by using SEM, FTIR, and XPS. The experimental data of U(VI) biosorption were fitted by the pseudo-second-order. The maximum uptake capacity was 179.5 mg/g at pH 6.0 by Langmuir model. The thermodynamic results: ΔGо, ΔHо and ΔSо for uptake processes were calculated as -6.359 kJ/mol, 14.20 kJ/mol and 67.19 J/mol/K, respectively. The results showed that the biosorption of Bacillus amyloliquefaciens will be an ideal method to remove radionuclides.


Asunto(s)
Bacillus amyloliquefaciens/metabolismo , Biodegradación Ambiental , Uranio/metabolismo , Contaminantes Radiactivos del Agua/metabolismo , Adsorción , Cinética , Termodinámica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...