Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
J Oral Implantol ; 50(1): 39-44, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38579111

RESUMEN

Ingestion or aspiration of dental implant screwdrivers or implant components is potentially life-threatening. There are no reports on the frequency at which dentists drop these devices within the mouth or which components are most problematic. There are few reports on what protective measures clinicians take, where risks exist, and how this problem is managed. A 9-part questionnaire was provided to dentists. Data collected included clinicians' roles, implant surgeons, restorative clinicians, or both-the frequency of dropping implant screwdrivers or components, items considered most problematic. Patient protection and management were also requested. Finally, questions related to how much of a problem clinicians considered this to be and if further solutions and a standardized management protocol should be developed. One hundred twelve dentists voluntarily completed the survey. Of the dentists, 54% restored, 37% restored and surgically placed, and 9% solely placed implants. Twenty-nine percent claimed never to drop components, with 56% dropping an instrument less than 10% of the time. Less than half would suggest patients seek medical advice if a screwdriver or component was accidentally dropped intraorally and was not recovered. Thirty percent never tied floss tethers to screwdrivers, and a similar percentage reported they only sometimes did so. Throat pack protection was reported 51% of the time. Ninety percent considered dropping components an issue, with screwdrivers most problematic. Aspiration or ingestion of implant screwdrivers and components is problematic, with dentists varying their use of protection devices. There is a need to standardize and implement patient protection procedures and management and develop methods to reduce the risk of these potentially life-threatening issues.


Asunto(s)
Implantes Dentales , Humanos , Encuestas y Cuestionarios , Odontólogos
2.
J Prosthet Dent ; 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38519327

RESUMEN

STATEMENT OF PROBLEM: The esthetic assessment of smile lines by laypersons is a subject of ongoing debate. However, smile lines often appear with different types of upper lip curvature, which further complicates the esthetic assessment process, and studies on this combination are lacking. PURPOSE: The purpose of this clinical study was to investigate a layperson's esthetic perception of smile lines and upper lip combined images. MATERIAL AND METHODS: Twenty-six smile images resulting from combinations of 3 upper lip types, 4 anterior smile line types, and 3 posterior smile line types were generated by an image editing software program. Eighty-three laypersons (39 men and 44 women; 18 to 35 years of age) completed rating images using a visual analog scale. Unattractive smiles were designated to be those with scores <50 and attractive ones with scores ≥50. Data were analyzed using 1-way analysis of variance and Bonferroni post hoc tests (α=.05). RESULTS: High anterior smile line with gingival display >4 mm obtained significantly lower scores of <50 when combined with all upper lip curvatures (upward: 28.29 ±22.79, straight: 38.74 ±23.00, downward: 30.67 ±22.25, P<.01). High anterior smile lines with gingival display ≤4 mm combined with upward and straight upper lip curvature images obtained significantly higher scores, and all were ≥50 (upward: 63.24 ±22.22, straight: 61.40 ±21.58, P<.01). CONCLUSIONS: From a layperson's perspective, high anterior smile lines with gingival display >4 mm combined with any lip type were determined to be unattractive. If gingival display was ≤4 mm combined with both upward and straight lip types, the smile was assessed as attractive.

3.
J Oral Implantol ; 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38312057

RESUMEN

STATEMENT OF THE PROBLEM: Ingestion or aspiration of dental implant screwdrivers or implant components is potentially life-threatening. There are no reports on the frequency at which dentists drop these devices within the mouth or which components are most problematic. There are few reports on what protective measures clinicians take, where risks exist, and how this problem is managed. MATERIALS AND METHODS: A nine-part questionnaire was provided to dentists. Data collected included Clinicians' roles, implant surgeons, restorative clinicians, or both-frequency of dropping implant screwdrivers or components, items considered most problematic. Patient protection and management were also requested. Finally, questions related to how much of a problem clinicians considered this to be and if further solutions and a standardized management protocol should be developed. RESULTS: One hundred twelve dentists voluntarily completed the survey.54% restored, 37% restored and replaced, and 9% solely placed implants. 29% claimed never to drop components, with 56% dropping an instrument less than 10% of the time. Less than half would suggest patients seek medical advice if a screwdriver or component was accidentally dropped intraorally and was not recovered. 30% never tie floss tethers to screwdrivers, and a similar percentage reported only sometimes. Throat pack protection was reported 51% of the time. 90% considered dropping components an issue, with screwdrivers most problematic. CONCLUSIONS.: Aspiration or ingestion of implant screwdrivers and components is problematic with dentists varying with their use of protection devices. There is a need to standardize and implement patient protection procedures and management and develop methods to reduce the risk of these potentially life-threatening issues.

4.
J Prosthodont ; 33(4): 340-347, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37203989

RESUMEN

PURPOSE: The aim of this in vitro study was to assess the effects of using different cements and titanium copings designs on the retention of implant-supported fixed dental prostheses (IFDPs) using a pull-out test. MATERIALS AND METHODS: Fifty zirconia (ZirCAD; Ivoclar Vivadent) and 20 prepolymerized denture acrylic resin (AvaDent) rectangular (36 mm × 12 mm × 8 mm) specimens were milled to mimic the lower left segmental portion of the All-on-Four IFDPs. Cylindrical titanium copings (Variobase; Straumann) (V) were used in 2 prepolymerized denture acrylic resin groups (n = 10) while conical titanium copings (Straumann) (C) were used as a control group for zirconia with 4 groups using cylindrical titanium copings. Before cementation, the outer surfaces of all titanium copings and the intaglio bonding surface of prosthetic specimens were airborne-particle abraded. All specimens were cemented following the manufacturer's recommendations and instructions according to the experimental design. After artificial aging (5000 cycles of 5°C 55°C, dwelling time 20 s; 150 N, 1.5 Hz in a 37°C water bath), all specimens were subjected to retention force testing using a pull-out test using a universal testing machine and a custom fixture with a crosshead speed 5 mm/min. Modes of failure were classified as Type 1, 2, or 3. Retention force values were analyzed by the t-test for the prepolymerized denture acrylic resin specimen groups, and 1-way ANOVA and the Tukey test for the zirconia groups at α = 0.05. RESULTS: Mean and standard deviation retention force values varied from 101.1 ± 67.1 to 509.0 ± 65.2 N for the prepolymerized denture acrylic resin specimen groups. The zirconia groups ranged from 572.8 ± 274.7 to 1416.1 ± 258.0 N. There is no statistically significant difference in retention force values between V and C specimens cementing to zirconia with Panavia SA cement (Kuraray Noritake) (p = 0.587). The retention forces and failure modes were influenced by the cement used (p < 0.05). Modes of failure were predominantly Type 2 (mixed failure) and Type 1 (adhesive fracture from prosthetic materials) except for the quick-set resin group (Type 3, adhesive failure from coping). CONCLUSIONS: When bonding IFDPs onto titanium copings, quick-set resin provided significantly higher retention force for prepolymerized denture acrylic resin prostheses. Conical and cylindrical titanium copings performed similarly when cemented to zirconia with Panavia SA cement under the same protocol. The stability of the bonded interface and retention forces between zirconia prostheses and titanium copings varied from the cement used.


Asunto(s)
Silicatos de Aluminio , Implantes Dentales , Titanio , Cementos Dentales , Cementos de Resina , Circonio , Cementos de Ionómero Vítreo , Resinas Acrílicas , Adaptación Psicológica , Ensayo de Materiales , Análisis del Estrés Dental , Retención de Prótesis Dentales , Propiedades de Superficie
5.
J Prosthet Dent ; 130(6): 866-876, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35153064

RESUMEN

STATEMENT OF PROBLEM: A novel zirconia-alumina composite (ZAC) particle has yet to be studied for airborne-particle abrasion in a bonding protocol for the zirconia surface. PURPOSE: The purpose of this in vitro study was to evaluate the shear bond force of resin cement to yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) when using spherical ZAC particles to conduct airborne-particle abrasion and modify the topography of Y-TZP. MATERIAL AND METHODS: Spherical 30- to 70-µm ZAC particles were fabricated by using a hybrid gel technique. A total of 160 Ø6.6×4.0-mm zirconia disks were fabricated from 4 commercially available zirconia blanks, e.max ZirCAD zirconia (EM), NexxZr T zirconia (NE), Lava Plus High Translucency zirconia (LP), and Imagine High Translucency Zirconia (IM), by using computer-aided manufacturing technology. As-sintered specimens without further surface treatment were used as controls (ZR0). Surface treatment groups included sharp-edged alumina airborne-particle abrasion (ABC), 50 µm, 0.2 MPa; airborne-particle abrasion with ZAC particle at 0.2 MPa (2ZA); and airborne-particle abrasion with spherical ZAC particle at 0.4 MPa (4ZA). All surface treatment groups were airborne-particle abraded at the specified pressures for 10 seconds at a standardized distance of 10 mm. The surface roughness (Ra) and area roughness (Sa) of specimens from each group were measured. Following the application of an adhesive (Scotchbond Universal), Ø6.6×4.0-mm resin cement (RelyX Ultimate) buttons were fabricated for shear bond testing by using a universal testing machine at a 5-mm/min crosshead speed (n=10). The data were analyzed by using a 2-way ANOVA, Tukey HSD test, and regression analysis (α=0.05). Scanning electron microscopy (SEM) was performed to observe changes of the zirconia surface and the failure modes of each group before and after shear bond testing. RESULTS: The mean ±standard deviation shear bond force values ranged from 272.6 ±41.4 N to 686.7 ±152.8 N. Statistically significant higher force values than those of the controls (P<.05) were obtained by using airborne-particle abrasion. No significant differences were found among any of the airborne-particle abrasion treatment groups (P>.05). The mean of Ra values ranged from 0.27 µm to 0.74 µm, and the mean of Sa values, from 0.48 µm to 1.48 µm. SEM observation revealed that the zirconia surface was made jagged by abrasion with sharp-edged alumina particles. The spherical ZAC particles create microcraters on the zirconia surface. Fractographic observation disclosed that failures were adhesive-cohesive failure modes with residual resin cement attached on the zirconia surface. CONCLUSIONS: The surface treatment of zirconia with sharp-edged alumina or the spherical ZAC abrasives improved the bonding force between the zirconia and resin cement. No statistically significant differences in shear bond force values were found between airborne-particle abrasion surface treatment groups.


Asunto(s)
Recubrimiento Dental Adhesivo , Materiales Dentales , Materiales Dentales/química , Cementos de Resina/química , Propiedades de Superficie , Cerámica/química , Circonio/química , Óxido de Aluminio/química , Ensayo de Materiales , Resistencia al Corte , Análisis del Estrés Dental
6.
J Prosthet Dent ; 129(5): 763-768, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-34482966

RESUMEN

STATEMENT OF PROBLEM: The output torque delivered by a dental implant toggle-style torque wrench is known to be affected by activation rate. The International Organization for Standardization (ISO) established the ISO 6789-1 standard to provide guidance on activation rates relative to desired output torque in the Nm torque range. Whether the ISO 6789-1 standard applies at the relatively lower dental torque ranges is not known, and little information is available on the activation rates that clinicians use and how this may affect output torque. PURPOSE: The purpose of this in vitro study was to determine how output torque values vary with the activation rates used by clinicians at dental implant-relevant target torque values. MATERIAL AND METHODS: To determine clinically relevant activation rates, a new adjustable dental implant toggle-style torque wrench was activated from 0 to 25 Ncm target torque by 5 prosthodontists by using a custom mandibular and maxillary typodont model containing implants and abutments with screws. This provided a baseline of activation rates (mm/sec). Data were transferred to a computerized numerical control model incorporating a variable speed linear motor, which was used to drive a dental implant toggle-style torque wrench attached to an electronic torque measuring device. Constant speed and a regulated dual-speed-assigned 80/20 rate group, where 80% of target torque value was delivered first, then a pause, and the final 20% at different speeds as suggested by the ISO 6789-1 standard, were evaluated. Fast, medium, and slow rates were categorized and applied with target torque values of 10, 25, and 35 Ncm, respectively, for n=12 activations. The output torque values were recorded for both constant and 80/20 groups and compared with the desired target torque values. Data were statistically analyzed with 1-way ANOVA and the Scheffé post hoc paired t test (α=.05). RESULTS: The clinicians' activation rates from 0 to 25 Ncm on the typodont model converted into linear speeds resulted in fast =24.19 mm/sec, medium =14.5 mm/sec, and slow =7.25 mm/sec. When actioned at a constant rate, the mean output torque values were generally in the order of slow > medium > fast in activation rates. Generally, precision output torque decreased as target torque increased, especially when slow and medium rates, either constant or regulated 80/20 were used. All mean output torque for slow, medium, and their 80/20 variants were greater than target torque. Fast and 80/20 fast produced the lowest mean output torque values for all torque settings, and at the 35 Ncm setting, the dental implant toggle-style torque wrench output torque mean values were lower than target torque. Statistically significant differences (P<.05) were found among groups, most notably in the 80/20 dual-speed groups, especially in comparisons with the 80/20 fast rate group. When the target torque value was 10 Ncm with the 80/20 fast rate, the output torque value deviated from the maximum ISO limit by more than 6%. CONCLUSIONS: The rate of actioning a dental implant toggle-style torque wrench influenced the delivered torque value, with fast rate actioning producing lower and less precise output torque values.


Asunto(s)
Implantes Dentales , Torque , Pilares Dentales , Análisis del Estrés Dental
7.
J Prosthodont ; 32(2): 139-146, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35315177

RESUMEN

PURPOSE: The aim of this in vitro study was to assess the efficacy of fiber reinforcement to enhance flexural strength of the transitional implant-supported fixed dental prosthesis (TISFDP). MATERIALS AND METHODS: One hundred and forty denture acrylic resin plates (64 mm × 12 mm × 5 mm) with two 7 mm diameter holes were fabricated using heat-polymerized type (Lucitone 199) and CAD-CAM prepolymerized type (AvaDent) materials to simulate a chair-side reconstruction of the TISFDP. Specimens were divided into 7 groups (n = 10) according to the airborne-particle abrasion of titanium cylinder (Straumann) surface and locations of fiber reinforcement ribbons (Ribbond-ULTRA). No cylinder surface abrasion and no fiber added acrylate specimens were used as the controls. The prosthetic screws were hand-tightened on a custom fixture with analogs. Specimen hole and cylinder were joined using a 50:50 mixture of chemically polymerized resin (QYK-SET; Holmes Dental) and repair resin (Dentsply Sirona). Ten acrylate specimens with no holes were fabricated from each tested material and assigned as positive controls. A modified four-point bending test (ASTM standard-D6272) was conducted using a universal testing machine and a custom fixture with a crosshead speed 1 mm/min. The maximum failure loads were recorded. Data were statistically analyzed using 2-way ANOVA and the Tukey tests at α = 0.05. RESULTS: The flexural strength values ranged from 55.4 ±8.3 to 140.9 ±15.4 MPa. The flexural strength decreased significantly when fiber was attached on the titanium cylinder surface (p < 0.05). There were no statistically significant differences in flexural strength values between specimens with and without titanium cylinder surface abrasion (p > 0.05). Statistically significant improvement in flexural strength was observed in specimens with fibers attached around the specimen holes (p < 0.05) buccally and lingually. The obtained values were not statistically significantly different from the positive controls (p > 0.05). Some fixation screw fractures were observed before catastrophic failure of specimens during testing. CONCLUSIONS: Fiber reinforcement significantly improved the flexural strength of denture acrylic resins only if placed around the specimen holes on the tension side at the site of initiation of crack propagation. Even when the specimens underwent catastrophic failure, the segments remained attached to each other with the attached fibers.


Asunto(s)
Implantes Dentales , Resistencia Flexional , Titanio , Ensayo de Materiales , Docilidad , Propiedades de Superficie , Acrilatos , Análisis del Estrés Dental , Bases para Dentadura , Materiales Dentales
9.
J Prosthet Dent ; 130(4): 597-601, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34996611

RESUMEN

STATEMENT OF PROBLEM: Implant cantilever beam torque-limiting devices are affected by parallax, which may result in measurement read error. The overread or underread of the true target torque value could lead to premature failure of the screw joint of a dental implant. PURPOSE: The purpose of this in vitro study was to determine the effect of the operator's viewing angle relative to the cantilever beam and measurement reading scale when the torque-limiting device is actioned toward or away from the operator. MATERIAL AND METHODS: A beam torque wrench (Nobel Biocare USA) was used with the cantilever beam position fixed by using a wedge to read 32 Ncm on the marker arm. It was suspended in a vertical position relative to a digital single-lens reflex camera set at a fixed distance of 48 cm from the marker reading. The camera was rotated in 10-degree increments clockwise and counterclockwise relative to the cantilever beam reading, starting perpendicular to the marker. Photographs were recorded at each angle. Percentage measurement read error was calculated from dimensions of the cantilever beam torque device, including the beam diameter, distance from the marker arm, and the incremental marks on the measurement scale. Data were analyzed descriptively to determine the differences after comparison with the International Organization for Standardization (ISO) 6789-1:2017 recommendations. RESULTS: Photographs compared beam position relative to the 32-Ncm marker. The beam diameter was recorded as 1.5 mm, corresponding to approximately 5 Ncm. The distance between the marker arm and center of the beam was 0.08 mm. Percentage errors were greatest at lower torque values and increased relative to the viewing angle. Photographs showed that instrument overread was most likely to occur as the beam was moved away from the operator, which would result in potential undertightening unless compensated for. Underread was noted when the beam was pulled toward the operator. CONCLUSIONS: To prevent measurement read error when using an implant cantilever beam torque-limiting device, the operator should be positioned as close to a perpendicular viewing angle to the cantilever beam as possible. Viewing from an angle greater than 10 degrees from the perpendicular should be avoided for torque values less than 15 Ncm. For screws tightened between 25 Ncm and 35 Ncm, the viewing angle should be less than 30 degrees so that the applied torque is within the maximum deviation of the target torque value set by the ISO 6789-1:2017 recommendations.

10.
BMC Oral Health ; 22(1): 562, 2022 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-36463135

RESUMEN

OBJECTIVE: To investigate the spatial changes of unopposed molars within the period between the antagonist extraction and the final implant restoration using data from cone beam computed tomography. METHODS: A total of 59 patients with 68 unopposed molars were included in this study. Three-dimensional models reconstructed from cone beam computed tomography data before and after loss of the antagonist were superimposed to measure the spatial changes. The overeruption and tipping of target teeth were calculated by coordinate values. RESULTS: The result of overeruption over the study period (9.2 ± 4.3 months) was expressed by two values: the mean overeruption of molar cups (0.432 mm) and the maximum overeruption of cusps (0.753 mm), which were statistically significant compared to the baseline level (p < 0.001). The average tipping was 1.717 degrees in the buccal direction. CONCLUSIONS: Unopposed molars displayed overeruption throughout the study period (9.2 ± 4.3 months), which indicates that the clinicians should pay attention to the possibilities of overeruption and make appropriate interventions in their clinical practice. The establishment of three-dimensional measuring methods using cone beam computed tomography data helps analyze spatial changes.


Asunto(s)
Implantes Dentales , Humanos , Estudios Retrospectivos , Diente Molar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico
11.
BMC Oral Health ; 22(1): 630, 2022 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-36550438

RESUMEN

BACKGROUND: Assessment of the keratinized mucosa width (KMW) at edentulous sites is important for the subsequent implant treatment design. This pilot study aimed to evaluate the characteristics of the KMW at edentulous molar sites and explore the associated factors. METHODS: A total of 150 patients with 222 edentulous molar sites were included. The buccal KMW of the edentulous molar sites was measured during implant treatment planning. Potentially associated factors, including age, sex, smoking status, location, reasons for tooth loss/extraction, gingival phenotype (GP) and keratinized gingival width (KGW) of the adjacent teeth, were collected and analyzed. The Shapiro‒Wilk test, Student's t test, one-way ANOVA, generalized estimation equations (GEEs) and linear regression analysis were used for data analysis at α = 0.05. RESULTS: The buccal KMW at edentulous molar sites was 3.97 ± 2.06 mm, and 41.9% of sites presented with KMW < 4 mm. The mean KMWs of the maxillary sites were significantly higher than that those of the mandibular sites (4.96 ± 2.05 mm vs. 3.41 ± 1.85 mm, respectively). In total, 54.7%, 46.5%, 29.8%, and 0.0% of mandibular first and second molar sites and maxillary first and second molar sites, respectively, displayed a KMW of < 4 mm. Statistically significant linear correlations were found between KMW and GP (r = 0.161, p = 0.025) and between KMW and KGW of the adjacent teeth (r = 0.161, p = 0.023), while other factors were found to have no significant association. CONCLUSION: Within the limitations of the present study, the KMW at edentulous molar site was related to the location of molar tooth loss/extraction. The GP and KGW of the adjacent teeth of edentulous molar sites were also associated with their KMW, which was probably attributed to the continuity of the adjacent soft tissue.


Asunto(s)
Implantes Dentales , Boca Edéntula , Pérdida de Diente , Humanos , Proyectos Piloto , Mucosa Bucal , Diente Molar
12.
BMC Oral Health ; 22(1): 511, 2022 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-36397049

RESUMEN

BACKGROUND: Changes in alveolar bone dimension after tooth extraction may affect placement of the subsequent implant, resulting in ridge deficiency that can adversely impact long-term implant stability or aesthetics. Alveolar ridge preservation (ARP) was effective in reducing the amount of ridge resorption following tooth extraction. There is sparse evidence regarding the benefit of ARP at periodontally compromised molar extraction sockets. This study will be a randomized trial to assess the soft tissue contour, radiographical, and histological changes of ARP at molar extraction sites in order to compare severe periodontitis cases with natural healing results and determine the most beneficial and least traumatic clinical treatment for such patients. METHODS: This research is designed as a two-group parallel randomized controlled trial. The total number of tooth extraction sites will be 70 after calculation with power analysis. Teeth will be randomly assigned to two groups with the test group conducting ridge preservation and the control group healing naturally. Periodontal examination, cone beam-computed tomography (CBCT) data, and stereolithographic (STL) files obtained by intraoral scanning will be collected through the follow-up period, and bone biopsy samples would be obtained during implant surgery. The primary outcomes are the vertical and horizontal change of alveolar ridge measured on CBCT images, soft tissue contour changes evaluated by superimposing the digital impressions, alterations of mucosa thickness (as measured by superimposing the CBCT data and STL files), histological features of implant sites and periodontal parameter changes. The secondary outcomes are patient-reported post-operative reaction and conditions of simultaneous bone graft or sinus lifting procedures during implantation. DISCUSSION: This study will provide information about hard and soft tissue dimension changes and histomorphology evaluation following ARP and natural healing in periodontally compromised molar sites, which may contribute to complement the missing information of ARP at periodontally compromised molar extraction sockets. TRIAL REGISTRATION: Chinese Clinical Trial Register (ChiCTR) ChiCTR2200056335. Registered on February 4, 2022, Version 1.0.


Asunto(s)
Pérdida de Hueso Alveolar , Aumento de la Cresta Alveolar , Periodontitis , Extracción Dental , Humanos , Pérdida de Hueso Alveolar/diagnóstico por imagen , Pérdida de Hueso Alveolar/prevención & control , Pérdida de Hueso Alveolar/patología , Aumento de la Cresta Alveolar/métodos , Diente Molar/cirugía , Periodontitis/cirugía , Periodontitis/patología , Alveolo Dental/diagnóstico por imagen , Alveolo Dental/cirugía
13.
Biomed Opt Express ; 13(8): 4247-4260, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-36032575

RESUMEN

Due to rod-like hydroxyapatite crystal organizations, dental enamel is optically anisotropic, i.e., birefringent. Healthy enamel is known to be intrinsically negatively birefringent. However, when demineralization of enamel occurs, a considerable number of inter-crystallite spaces would be created between the crystallites in the enamel, which could lead to a sign reversion in birefringence of the enamel structure. We propose that this sign reversion can be leveraged in polarization sensitive OCT (PSOCT) imaging to differentiate early caries lesions from healthy enamel. In this study using PSOCT, we first confirm that the change in birefringence sign (negative to positive) can lead to a 90-degree alteration in the local axis orientation because of the switch between the fast and slow optic axes. We then demonstrate, for the first time, that the local axis orientation can be utilized to map and visualize the WSLs from the healthy enamel with a unique contrast. Moreover, the sharp alteration in local axis orientation gives a clear boundary between the WSLs and the healthy enamel, providing an opportunity to automatically segment the three-dimensional WSLs from the healthy enamel, enabling the characterization of their size and depth information in an intuitive way, which may aid clinical decision making and treatment planning.

14.
Biomed Opt Express ; 13(6): 3629-3646, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35781964

RESUMEN

There remains a clinical need for an accurate and non-invasive imaging tool for intraoral evaluation of dental conditions. Optical coherence tomography (OCT) is a potential candidate to meet this need, but the design of current OCT systems limits their utility in the intraoral examinations. The inclusion of light-induced autofluorescence (LIAF) can expedite the image collection process and provides a large field of view for viewing the condition of oral tissues. This study describes a novel LIAF-OCT system equipped with a handheld probe designed for intraoral examination of microstructural (via OCT) and microvascular information (via OCT angiography, OCTA). The handheld probe is optimized for use in clinical studies, maintaining the ability to detect and image changes in the condition of oral tissue (e.g., hard tissue damage, presence of dental restorations, plaque, and tooth stains). The real-time LIAF provides guidance for OCT imaging to achieve a field of view of approximately 6.9 mm × 7.8 mm, and a penetration depth of 1.5 mm to 3 mm depending on the scattering property of the target oral tissue. We demonstrate that the proposed system is successful in capturing reliable depth-resolved images from occlusal and palatal surfaces and offers added design features that can enhance its usability in clinical settings.

15.
PeerJ ; 10: e13421, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35669955

RESUMEN

Background: Information regarding using a pig cadaver model for teaching purposes in dentistry is limited, especially for periodontal surgery procedures. The aim of this study was to assess the feasibility and efficacy of teaching crown lengthening surgical procedures using a prepared pig cadaver model. Methods: Mandibles of slaughtered pigs with subgingival crown fracture defects on two premolars and two molars on each side were prepared as periodontal surgery teaching cases. A resident group (n = 20) and an instructor group (n = 18) participated in assessing the efficacy of the model by completing questionnaires before and after training sessions. Data was either assessed descriptively or analyzed statistically with Wilcoxon signed-rank test with the significance level at α = 0.05. Results: Results revealed that all the knowledge points showed statistically significant improvements (p < 0.05) except for the procedure to determine the quantity of bone removal during osteotomy procedures. Most residents rated the efficacy of the model obtained with 9.0 out of 10 scale. The data of effectiveness of the pig cadaver model from the instructor group ranged from 7.4 ± 1.4 to 9.0 ± 1.0. Conclusion: Results of this study support feasibility in using prepared pig cadaver models to teach crown lengthening surgical procedures to postgraduates.


Asunto(s)
Alargamiento de Corona , Coronas , Porcinos , Animales , Alargamiento de Corona/métodos , Cadáver
16.
Clin Oral Implants Res ; 33(7): 735-744, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35524437

RESUMEN

OBJECTIVE: To investigate the 3-year implant-related outcomes following alveolar ridge preservation in periodontally compromised molar sockets. MATERIAL AND METHODS: Thirty implants were placed in 26 patients following either ridge preservation (test, n = 16) or natural healing (control, n = 14) at deficient molar extraction sites after a 6-month healing period. The need for additional augmentation procedures at implant placement was recorded. Patients were assessed for 3 years following a definitive restoration. Patient information being collected included modified plaque index, the modified sulcus bleeding index, the peri-implant probing depth clinically, and alterations of marginal bone level (MBL) radiographically. RESULTS: There was a 100% survival rate of implants in both groups after 3-year follow-up. During implant placement operation, 35.7% in the control group and 6.3% in the test group required additional augmentation procedures. No statistically significant differences were determined for peri-implant parameters and marginal bone levels between the two groups. The overall mean difference of MBL was 0.072 mm (95% CI [-0.279, 0.423]) during the 3 years of follow-up. The success rate was 81.2% in the test and 78.6% in the control group. CONCLUSIONS: Implants placed into periodontally compromised molar-extracted sites after ridge augmentation resulted in comparable outcomes to implant placement at naturally healed sites after 3-year functional loading. (Chinese Clinical Trial Registry ChiCTR-ONN-16009433).


Asunto(s)
Aumento de la Cresta Alveolar , Implantes Dentales de Diente Único , Implantes Dentales , Aumento de la Cresta Alveolar/métodos , Estudios de Cohortes , Implantación Dental Endoósea/métodos , Estudios de Seguimiento , Humanos , Diente Molar/cirugía , Estudios Prospectivos , Extracción Dental/métodos , Alveolo Dental/cirugía , Resultado del Tratamiento
17.
Int Dent J ; 72(5): 659-666, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35341599

RESUMEN

OBJECTIVES: The aim of this research was to establish standard norms for posterior smile-related characteristics including posterior smile line (PSL), the most posterior teeth displayed, buccal corridor ratio (BCR), and buccal corridor symmetry (BCS) and investigate its aesthetic contributions to smile attractiveness in a Chinese population. MATERIALS AND METHODS: From digitally recorded dynamic smile videos of young Chinese participants, 188 standardised full-smile images were captured and then aesthetically evaluated by 22 laypersons using a visual analog scale (VAS). Four smile-related variables in the posterior region were analysed. VAS data were compared between subgroups to test the influence of these variables on smile aesthetics with significance level of P < .05. RESULTS: The VAS scores of participants with high PSL were significantly lower than those with average or low PSL (P < .01), especially when they display average or low anterior smile line (P < .05). Smiles with the second premolar displayed obtained the highest VAS amongst the 3 subgroups (P < .05). No significant differences were found between the VAS scores of BCR and BCS (P > .05). CONCLUSIONS: Maxillary posterior gingiva and teeth displayed influence smile attractiveness evaluated by laypersons, which should be given attention when treating patients with compromised aesthetics, especially those displaying average or low anterior smile lines.


Asunto(s)
Estética Dental , Diente , China , Humanos , Maxilar , Sonrisa
18.
BMC Oral Health ; 22(1): 99, 2022 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-35354462

RESUMEN

BACKGROUND: Whether to preserve a structurally compromised tooth or remove it is a dilemma often encountered by clinicians. The aim of this study was to assess the long-term success rate of fractured teeth preserved by modified crown lengthening surgery and restorations. METHODS: Thirty-nine patients with a total of 45 fractured teeth who had received modified crown lengthening surgery were recruited and examined. Numbers of teeth lost were recorded, and the criteria for successful teeth were defined. Kaplan-Meier estimator was used to determine the success rate. Possible risk factors were compared between successful and unsuccessful groups by a Cox regression analysis to explore the potential predictors of failure with a significant level at α = 0.05. RESULTS: The mean ± SD of success time without considering variants was 6.2 ± 0.6 years (95% CI 5.1-7.7). The mean survival rates ± SD at 1.0-, 2.0-, 3.0-, 5.0-, 7.0-, and 9.0-year intervals was 97.8 ± 2.2%, 92.2 ± 4.4%, 72.8 ± 7.9%, 68.2 ± 8.6%, 60.7 ± 10.5%, and 40.4 ± 13.6%, respectively. Failure cases in teeth with poor plaque control and step-shaped fracture margin were significantly more than those with good plaque control and knife-shaped fracture margin (HR = 7.237, p = 0.011; HR = 15.399, p = 0.006; respectively). CONCLUSIONS: Fractured teeth treated with modified crown lengthening surgery are anticipated to have a high clinical success rate for 6.2 ± 0.6 years. Plaque control and fracture morphology appeared to be significantly associated with the success of the multidisciplinary treatment approach.


Asunto(s)
Alargamiento de Corona , Fracturas de los Dientes , Alargamiento de Corona/efectos adversos , Coronas , Humanos , Corona del Diente/cirugía , Fracturas de los Dientes/etiología , Fracturas de los Dientes/cirugía
19.
Clin Oral Investig ; 26(3): 2391-2399, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34622309

RESUMEN

OBJECTIVES: To assess alveolar bone changes and treatment modality alterations after ridge preservation on maxillary molar extraction sockets with severe periodontitis, compared to natural healing. MATERIAL AND METHODS: Thirty-six maxillary infected-molar teeth either receiving ridge preservation (RG group) or undergoing natural healing (NT group) were investigated. Cone-beam computed tomography (CBCT) scanning was performed immediately after surgery (the baseline) and repeated 6 months later to measure the linear and volumetric changes of the sockets. RESULTS: Based on radiographic measurements, alveolar bone width decreased by 1.58 ± 4.61 mm in the NT group but increased by 3.74 ± 4.17 mm in the RG group (p < 0.05). Significant increases in ridge height at the center of both the NT (7.54 ± 4.54 mm) and RG (9.20 ± 3.26 mm) groups were observed. Mean sinus pneumatization was 0.19 ± 0.45 mm in the RG group and 0.59 ± 0.63 mm in the NT group (p < 0.05). The relative increase in total ridge volume was 8.0% and 35.5% in the NT and RG group, respectively (p < 0.05). Implant placement with additional sinus augmentation procedure was performed in 16.7% of the RG group cases, whereas 50% in the NT group cases. CONCLUSIONS: Ridge preservation in the maxillary molar extraction sockets with severe periodontitis can improve alveolar ridge dimensions and decrease the necessity of advanced regenerative procedures at implant placement compared to natural healing. CLINICAL RELEVANCE: Ridge preservation on maxillary molar extraction sockets with severe periodontitis maintained the vertical bone height more efficiently and resulted in less need for sinus augmentation procedures at 6 months compared to natural healing.


Asunto(s)
Pérdida de Hueso Alveolar , Aumento de la Cresta Alveolar , Periodontitis , Pérdida de Hueso Alveolar/diagnóstico por imagen , Pérdida de Hueso Alveolar/cirugía , Humanos , Diente Molar/cirugía , Periodontitis/cirugía , Extracción Dental , Alveolo Dental/cirugía
20.
Int J Oral Maxillofac Implants ; 36(3): 538-545, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34115069

RESUMEN

PURPOSE: The purpose of this study was to survey practicing clinicians and determine if differences existed concerning their use of torque-limiting devices (TLDs) and screw-tightening protocols, comparing this with existing universal industry standards. MATERIALS AND METHODS: A nine-question survey was administered with 428 dentists providing data for three specific areas: (1) demographic information-TLD ownership, device age, frequency of use, and observations of screw loosening; (2) recognition information-calibration, reading measurements of the TLD, and the meaning of preload; (3) usage information-screw-tightening protocols and effect of speed during actioning of the TLD. Data collection was compared with industry standards for use of hand torque tools including ISO-6789 1,2:2017 and related texts pertaining to screw fastener protocols. RESULTS: The beam-type TLD was the most popular; however, 33% surveyed used it incorrectly. Most TLDs being used were older than 1 year, with only 6% calibrated. Forty-eight percent observed screw loosening less than once per year, while 44% reported three or more occurrences per year. A similar number used the TLD for implant placement and abutment screw tightening. Screw-tightening protocols varied. Preload was not understood by the majority of those surveyed. CONCLUSION: Dentistry does not appear to adhere to the protocols and standards recommended by other industries that also rely on screw-fastening mechanisms and TLDs. Further education and training appears to be warranted in this area of implant dentistry to reduce the risks of screw-associated complications.


Asunto(s)
Pilares Dentales , Implantes Dentales , Tornillos Óseos , Análisis del Estrés Dental , Torque
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...