1.
Medicina (Kaunas) ; 60(3)2024 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-38541184

RESUMEN

Background and objectives: wear and corrosion can lead to the gross failure of the Morse taper junction with the consequent fracture of the true neck of the prosthetic stem in hip arthroplasty. Materials and Methods: 58-year-old male patient, with a BMI of 38 kg/m2. Because of avascular necrosis, in 2007, a metal-on-metal total hip arthroplasty was implanted in him, with a TMZF stem and a Co-Cr head. In December 2020, he complained of acute left hip pain associated with the deterioration of his left leg and total functional impairment, preceded by the crunching of the hip. X-rays and CT scan showed a fracture of the prosthetic neck that necessitated prosthetic revision surgery. A Scanning Electron Microscope (SEM) analysis of the retrieved prosthetic components was conducted. Results: Macroscopically, the trunnion showed a typical bird beak appearance, due to a massive material loss of about half of its volume. The gross material loss apparently due to abrasion extended beyond the trunnion to the point of failure on the true neck about half a centimeter distal from the taper. SEM analysis demonstrated fatigue rupture modes, and the crack began close to the neck's surface. On the lateral surface, several scratches were found, suggesting an intense wear that could be due to abrasion. Conclusions: The analysis we conducted on the explanted THA showed a ductile rupture, began close to the upper surface of the prosthetic neck where the presence of many scratches had concentrated stresses and led to a fatigue fracture.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas Óseas , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Microscopía Electrónica de Rastreo , Falla de Prótesis , Diseño de Prótesis
2.
Int J Surg Case Rep ; 116: 109374, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38401324

RESUMEN

INTRODUCTION AND IMPORTANCE: Total hip arthroplasty is one of the most performed surgical interventions in the world. Adverse local tissue reactions and pseudotumors are infrequent but dangerous eventualities, which are often related with metal-on-metal or metal-on-polyethylene implants. This study wants to highlight how adverse local tissue reactions and pseudotumors must be taken into consideration during the diagnostic process. CASE PRESENTATION: We report the case of a patient with ceramic-on-ceramic modular total hip arthroplasty with titanium neck. 12 years after surgery, he complained of pain and swelling on the hip. Diagnostic tests revealed the presence of a bulky pseudotumor. During the revision surgery biopsy samples were taken and microscopical analysis revealed the presence of fibrous tissue, fibrin hemorrhagic collections, histiocytes and chronic inflammation due to foreign body, with dark refractive material of an exogenous nature. CLINICAL DISCUSSION: The possible formation of pseudotumor and metallosis reactions in hip prostheses with metal-on-metal coupling or in couplings with polyethylene is known. Many cases of pseudotumor are reported after revision of prostheses due to the breakage of ceramic components, but we did not observe any damage or corrosion of the prosthetic elements; on the other hand, we noticed an excessive retroversion of the femoral neck. It may be possible that an accurate microscopic analysis could clarify the failure of this implant. CONCLUSION: To date ceramic-ceramic coupling remains the gold standard in terms of resistance and durability for hip arthroplasty but there is still a gap of knowledge in the field of tribology and individual immune response mechanisms.

3.
Life (Basel) ; 14(1)2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38255700

RESUMEN

BACKGROUND: The aim of our study is to emphasizes the significance of prompt diagnosis and intervention in younger patients affected by osteochondral detachment after patellar dislocation, where the first objective is to minimize in the shortest possible time complications and ingravescence. The method involves a clinical patient assessment and MRI follow-up in subjects who underwent to an immediate surgical intervention for osteochondral damage. METHODS: From January 2020 to December 2022, 22 patellar dislocation cases were assessed; osteochondral lesions were identified in 12 (54%) patients; nine of these patients were treated immediately with knee arthroscopy, while in seven instances the osteochondral fragment was reattached using bioabsorbable pins. Post-operative clinical evaluations were conducted at one-, three-, and six-month intervals; finally, a six-month post-operative MRI was performed for all surgically treated patients. RESULTS: The MRI evaluations, conducted six months post-operation for all seven patients, indicated successful integration of the reattached osteochondral fragment. Every patient returned to their pre-injury activities after surgery. However, two of them reported mild pain in the anterior region of the knee post-surgery. CONCLUSIONS: in young patients, swift diagnosis and immediate surgical intervention for osteochondral detachment resulting from patellar dislocation are crucial. This approach has been identified as the best practice, since it substantially minimizes immediate functional restrictions and significantly lowers the long-term risk of femoral-patellar osteoarthritis.

4.
Acta Biomed ; 94(S2): e2023171, 2023 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-38193531

RESUMEN

Intraoperative femoral fracture is a rare but growing complication of primary total hip arthroplasty. We aimed to present an uncommon related case, assessing also the role of malnutrition and osteoporosis. We discuss the case of a 49 years old male patient, malnourished and osteoporotic, with an intertrochanteric, multifragmentary, inveterate fracture, that happened three months before. During the prosthetic surgery, a supracondylar fracture occurred. We synthesized it with a 13 holes LISS plate, 7 distal screws and 3 proximal cerclage wires. The leg was immobilized to 0° for 3 weeks and the load forbidden for 3 months. Calcium, Albumine, Total Proteins, Osteocalcin and Vitamin-D levels were below the normal range. Teriparatide was administered for 6 months. Global investigation of the patient's nutritional status is recommended before joint replacement and preoperative planning is mandatory to choose the adequate implant. Osteoanabolic therapy could be advisable to favor fracture healing.