Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int J Obstet Anesth ; 24(4): 383-7, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26431780

RESUMEN

Morquio syndrome, a congenital mucopolysaccharidosis, presents several challenges for the provision of effective labor analgesia. We report the case of a woman admitted for induction of labor who received an early epidural and subsequently required cesarean delivery. Optimal bilateral labor analgesia was not achieved despite multiple adjustments, and systemic analgesia was needed for cesarean delivery.


Asunto(s)
Analgesia Epidural/métodos , Analgesia Obstétrica/métodos , Cesárea , Trabajo de Parto , Mucopolisacaridosis IV/complicaciones , Complicaciones del Embarazo/cirugía , Adulto , Femenino , Humanos , Mucopolisacaridosis IV/cirugía , Embarazo
2.
Int J Obstet Anesth ; 11(3): 211-5, 2002 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15321550

RESUMEN

We present two cases of neurovascular disease in pregnancy in which transcranial Doppler was used to assess the status of the cerebral circulation during cesarean section under regional anesthesia. One woman had been found to have moyamoya disease, following a series of transient ischemic attacks during her first pregnancy, which ended in spontaneous abortion. On this occasion she was delivered by cesarean section under slowly-induced epidural anesthesia, using ephedrine to maintain the blood pressure, and transcranial Doppler revealed no change in signal in her left middle cerebral artery. Both mother and baby had an uneventful post natal course. The second case involved a primiparous woman with a large arteriovenous malformation that had been detected following generalized seizures, which were treated with valproic acid. Her cesarean section was conducted under spinal anesthesia, and her blood pressure maintained with ephedrine. Again transcranial Doppler revealed no change in signal in her middle cerebral artery during the procedure. We believe this is a potentially useful technique to monitor the cerebral circulation intraoperatively in the presence of cerebrovascular disease.

3.
Int J Obstet Anesth ; 10(3): 168-71, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15321605

RESUMEN

Needle size and shape may influence the incidence of paresthesias, post-dural puncture headache and other complications during combined spinal-epidural (CSE) procedures. We have noted a relatively high incidence of transient paresthesias during placement of the spinal needle during CSE for labor analgesia. The purpose of this study was to compare the occurrence of paresthesia and post-dural puncture headache in parturients who received CSE analgesia with either a 25-gauge or 27-gauge Whitacre needle. In a prospective observational study, data were gathered from 478 consecutive women receiving labor analgesia. Incidence, duration, and character of any paresthesias upon spinal needle placement and the incidence and treatment of headache were recorded. The incidence of paresthesia with the two needles was similar (16% with 25-gauge vs 15.4% with 27 gauge) but the incidence of post-dural puncture headache was higher with the 25-gauge needle (4% vs 0.7% with 27 gauge, P < 0.05). Our data suggest that with Whitacre needles, 27-gauge might be preferable to 25-gauge needles to reduce the rate of post-dural puncture headache in parturients but that they do not alter the incidence of transient paresthesias.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA