Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Am Heart Assoc ; 13(5): e031305, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38420763

RESUMEN

BACKGROUND: Preoperative kidney dysfunction is a risk factor for right heart failure (RHF) after implantation of a left ventricular assist device (LVAD). However, characteristic kidney function trajectories before and after post-LVAD RHF are uncertain, so we investigated this. METHODS AND RESULTS: We identified individuals who received primary continuous-flow LVAD implantation from July 1, 2014 to December 31, 2017 in the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) data set. Incident RHF was ascertained using the INTERMACS definition at 1 and 3 months and classified as transient or persistent. Kidney function trajectories before and after RHF onset, and relationships of baseline kidney function with RHF risk at the different time points, were assessed. We identified 8076 LVAD recipients who met inclusion criteria. Incident RHF was present at 1 month in 26.4%. There were 4850 individuals with follow-up at 3 months, with incident RHF in 4.2%. Kidney function trajectories differed from pre-LVAD implantation to 1-month follow-up by RHF category, with those developing persistent RHF having no improvement in baseline kidney function. For trajectories before the 3-month RHF ascertainment time, the shape was similar for those with and without RHF, with lower estimated glomerular filtration rate levels among those who developed RHF. Baseline estimated glomerular filtration rate levels below the normal range were associated with higher risk of RHF at 1 and 3 months. CONCLUSIONS: In LVAD recipients, preimplantation kidney function and subsequent kidney function trajectories differed substantially by RHF at 1 and 3 months postimplantation, even after adjustment for several confounders. This may demonstrate bidirectional associations between kidney function and right ventricular function in LVAD recipients.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Estudios Retrospectivos , Factores de Riesgo , Corazón Auxiliar/efectos adversos , Riñón
2.
ASAIO J ; 2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38181411

RESUMEN

We explored whether women undergo continuous-flow left ventricular assist device (CF-LVAD) implantation in later stages of heart failure (HF) than men, evidenced by worse preoperative right HF (RHF). We also compared two propensity models with and without preoperative RHF to assess its effect on outcomes. INTERMACS was queried from July 2008 to December 2017. Propensity model 1 matched men and women on age ≥50 years, HF etiology, body surface area, INTERMACS class, comorbidities, device strategy, temporary mechanical circulatory support, and device type. Model 2 included these variables plus LV end-diastolic diameter, right atrial pressure/pulmonary capillary wedge pressure, pulmonary artery pulsatility index, and right ventricular ejection fraction. The primary outcome was all-cause mortality. Secondary outcomes comprise RHF, rehospitalization, renal dysfunction, stroke, and device malfunction. In model 1, characteristics were comparable between 3,195 women and 3,195 men, except women more often had preoperative RHF and postoperative right VAD support and had worse 1 year and overall survival. In model 2, after propensity matching for additional risk factors for preoperative RHF, 1,119 women and 1,119 men had comparable post-LVAD implant RVAD use and survival. These findings suggest that women present more often with biventricular failure and after implantation have higher RHF and mortality rates.

3.
Tex Heart Inst J ; 50(4)2023 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-37624675

RESUMEN

BACKGROUND: Postoperative respiratory failure is a major complication that affects up to 10% of patients who undergo cardiac surgery and has a high in-hospital mortality rate. Few studies have investigated whether patients who require tracheostomy for postoperative respiratory failure after continuous-flow left ventricular assist device (CF-LVAD) implantation have worse survival outcomes than patients who do not. OBJECTIVE: To identify risk factors for respiratory failure necessitating tracheostomy in CF-LVAD recipients and to compare survival outcomes between those who did and did not require tracheostomy. METHODS: Consecutive patients who underwent primary CF-LVAD placement at a single institution between August 1, 2002, and December 31, 2019, were retrospectively reviewed. Propensity score matching accounted for baseline differences between the tracheostomy and nontracheostomy groups. Multivariate logistic regression was used to identify tracheostomy risk factors and 90-day survival; Kaplan-Meier analysis was used to assess midterm survival. RESULTS: During the study period, 664 patients received a CF-LVAD; 106 (16.0%) underwent tracheostomy for respiratory failure. Propensity score matching produced 103 matched tracheostomy-nontracheostomy pairs. Patients who underwent tracheostomy were older (mean [SD] age, 57.9 [12.3] vs 54.6 [13.9] years; P = .02) and more likely to need preoperative mechanical circulatory support (61.3% vs 47.8%; P = .01) and preoperative intubation (27.4% vs 8.8%; P < .001); serum creatinine was higher in the tracheostomy group (mean [SD], 1.7 [1.0] vs 1.4 [0.6] mg/dL; P < .001), correlating with tracheostomy need (odds ratio, 1.76; 95% CI, 1.21-2.56; P = .003). Both before and after propensity matching, 30-day, 60-day, 90-day, and 1-year survival were worse in patients who underwent tracheostomy. Median follow-up was 0.8 years (range, 0.0-11.2 years). Three-year Kaplan-Meier survival was significantly worse for the tracheostomy group before (22.0% vs 61.0%; P < .001) and after (22.4% vs 48.3%; P < .001) matching. CONCLUSION: Given the substantially increased probability of death in patients who develop respiratory failure and need tracheostomy, those at high risk for respiratory failure should be carefully considered for CF-LVAD implantation. Comprehensive management to decrease respiratory failure before and after surgery is critical.


Asunto(s)
Corazón Auxiliar , Procedimientos Quirúrgicos Torácicos , Humanos , Persona de Mediana Edad , Traqueostomía/efectos adversos , Estudios Retrospectivos , Mortalidad Hospitalaria
4.
JACC Heart Fail ; 11(5): 491-503, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36892486

RESUMEN

In 2018, the United Network for Organ Sharing implemented a 6-tier allocation policy to replace the prior 3-tier system. Given increasing listings of critically ill candidates for heart transplantation and lengthening waitlist times, the new policy aimed to better stratify candidates by waitlist mortality, shorten waiting times for high priority candidates, add objective criteria for common cardiac conditions, and further broaden sharing of donor hearts. There have been significant shifts in cardiac transplantation practices and patient outcomes following the implementation of the new policy, including changes in listing practices, waitlist time and mortality, transplant donor characteristics, post-transplantation outcomes, and mechanical circulatory support use. This review aims to highlight emerging trends in United States heart transplantation practice and outcomes following the implementation of the 2018 United Network for Organ Sharing heart allocation policy and to address areas for future modification.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Obtención de Tejidos y Órganos , Humanos , Estados Unidos , Insuficiencia Cardíaca/cirugía , Donantes de Tejidos , Políticas , Listas de Espera , Estudios Retrospectivos
5.
ASAIO J ; 69(5): 429-437, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36730653

RESUMEN

Heart failure (HF) is common in adult congenital heart disease (ACHD) patients; however, use of continuous-flow ventricular assist devices (CF-VADs) remains rare. We reviewed outcomes of patients with congenital heart disease greater than or equal to 18 years of age at the time of CF-VAD implant at the affiliated pediatric and adult institutions between 2006 and 2020. In total, 18 ACHD patients (15 with great anatomical complexity) received 21 CF-VADs. Six patients (median age 34 years) received seven percutaneous CF-VADs with a median duration of support of 20 days (3-44 days) with all patients survived to hospital discharge and two patients were bridged to durable CF-VADs. Fourteen patients (median age 38 years) received durable CF-VADs. Thirteen patients (93%) survived to hospital discharge and the median duration of support was 25.8 months (6.4-52.1 months). Estimated survival on durable CF-VAD at 1, 3, and 5 years was 84%, 72%, and 36%, respectively. Three patients were successfully bridged to transplantation. Device-related complications include cerebrovascular accident (n = 5), driveline infection (n = 3), device infection requiring chronic antibiotic therapy (n = 4), gastrointestinal bleeding (n = 6), and presumed pump thrombosis (n = 5). These results show percutaneous and durable CF-VADs can support ACHD patients with advanced HF.


Asunto(s)
Cardiopatías Congénitas , Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Niño , Humanos , Adulto , Resultado del Tratamiento , Estudios Retrospectivos , Estudios Multicéntricos como Asunto
7.
J Artif Organs ; 26(4): 275-286, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36208373

RESUMEN

Patients with left ventricular assist devices (LVADs) receive anticoagulation to decrease the risk of thrombosis. Various circumstances require discontinuing anticoagulation in LVAD patients, but the risks entailed are not well defined. In a retrospective review of LVAD implantation procedures, we examined the effect of time off anticoagulation on thrombosis and mortality rates after implantation. An international normalized ratio ≤ 1.5 was used to screen for patients taken off anticoagulation. Patients were divided into three groups by the cumulative number of days off anticoagulation: no discontinuation, short-term discontinuation (< 30 days), and long-term discontinuation (≥ 30 days). Rates of ischemic stroke, pump thrombosis, and mortality were compared among groups. Of 245 patients who underwent LVAD implantation during the study, 70 (28.6%) were off anticoagulation during follow-up: 37 (15.1%) had short-term discontinuation (median, 11 days), and 33 (13.5%) had long-term discontinuation (median, 124 days). Patients with long-term discontinuation had a higher rate of ischemic stroke (adjusted hazard ratio 8.5, p = 0.001) and death (adjusted hazard ratio 3.9, p = 0.001). The three groups did not differ in pump thrombosis rate. We conclude that after LVAD implantation, discontinuing anticoagulation for ≥ 30 days is independently associated with an increased risk of ischemic stroke and death.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular Isquémico , Trombosis , Humanos , Corazón Auxiliar/efectos adversos , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/complicaciones , Trombosis/etiología , Trombosis/prevención & control , Estudios Retrospectivos , Anticoagulantes/uso terapéutico , Accidente Cerebrovascular Isquémico/inducido químicamente , Accidente Cerebrovascular Isquémico/complicaciones , Resultado del Tratamiento
8.
J Heart Lung Transplant ; 41(12): 1798-1807, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36182652

RESUMEN

BACKGROUND: The aim of this study was to assess for distinct kidney function trajectories following left ventricular assist device (LVAD) placement. Cohort studies of LVAD recipients demonstrate that kidney function tends to increase early after LVAD placement, followed by decline and limited sustained improvement. Inter-individual differences in kidney function response may be obscured. METHODS: We identified continuous flow LVAD implantations in US adults (2016-2017) from INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support). Primary outcomes were estimated glomerular filtration rate (eGFR) trajectories pre-implantation to ∼12 months. Latent class mixed models were applied to primary and validation samples. Clinical differences among trajectory groups were investigated. RESULTS: Among 4,615 LVAD implantations, 5 eGFR trajectory groups were identified. The 2 largest groups (Groups 1 and 2) made up >80% of the cohort, and were similar to group average trajectories previously reported, with early eGFR rise followed by decline and stabilization. Three novel trajectory groups were found: worsening followed by sustained low kidney function (Group 3, 10.1%), sustained improvement (Group 4, 3.3%), and worsening followed by variation (Group 5, 1.7%). These groups differed in baseline characteristics and outcomes. Group 4 was younger and had more cardiogenic shock and pre-implantation dialysis; Group 3 had higher rates of pre-existing chronic kidney disease, along with older age. CONCLUSIONS: Novel eGFR trajectories were identified in a national cohort, possibly representing distinct cardiorenal processes. Type 1 cardiorenal syndrome may have been predominant in Group 4, and parenchymal kidney disease may have been predominant in Group 3.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Adulto , Humanos , Insuficiencia Cardíaca/cirugía , Resultado del Tratamiento , Sistema de Registros , Riñón , Estudios Retrospectivos
9.
Artif Organs ; 46(9): 1923-1931, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35524483

RESUMEN

BACKGROUND: Hyponatremia is associated with adverse outcomes in heart failure and after cardiac surgery. We hypothesized that hyponatremia is associated with poorer short-term and longer term survival in patients after continuous-flow left ventricular assist device (CF-LVAD) placement. METHODS: We reviewed a single-center database of patients who received a CF-LVAD during 2012-2017. Sodium (Na) values obtained within 14 days before CF-LVAD insertion were averaged; patients (n = 332) were divided into hyponatremia (mean Na <135 mEq/L; n = 160; 48.2%) and normonatremia groups (mean Na 135-145 mEq/L; n = 172; 51.8%). Patients requiring preoperative dialysis or pump exchange were excluded. We compared outcomes between preoperative hyponatremia and normonatremia groups. RESULTS: The two groups' baseline characteristics were similar, although hyponatremia patients more often had preoperative mechanical circulatory support (44.4% vs. 31.4%, p = 0.002). Although hyponatremic and normonatremic patients did not differ in 30-day mortality (7.5% vs. 6.5%, p = 0.7), preoperative hyponatremia was associated with greater 5-year mortality (61% vs. 44%, p = 0.03). On binary logistic regression analysis, the strongest independent predictors of late mortality were hyponatremia (odds ratio [OR] 1.88, 95% CI [1.07-3.31], p = 0.02), older age (OR 1.03, 95% CI [1.01-1.05], p = 0.01), and elevated mean right atrial pressure/pulmonary capillary wedge pressure ratio (OR 4.69, 95% CI [1.76-12.47], p = 0.002). CONCLUSIONS: Hyponatremia was not associated with greater early mortality but was associated with poorer late survival. The optimal timing of LVAD implantation in relation to hyponatremia, and whether correcting hyponatremia perioperatively improves long-term survival, should be investigated.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Corazón Auxiliar , Hiponatremia , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Corazón Auxiliar/efectos adversos , Humanos , Hiponatremia/epidemiología , Análisis de Supervivencia , Resultado del Tratamiento
10.
Kidney360 ; 3(3): 569-579, 2022 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-35582171

RESUMEN

Durable and temporary mechanical circulatory support (MCS) use is growing for a range of cardiovascular indications. Kidney dysfunction is common in people evaluated for or receiving durable or temporary MCS and portends worse outcomes. This kidney dysfunction can be due to preexisting kidney chronic kidney disease (CKD), acute kidney injury (AKI) related to acute cardiovascular disease necessitating MCS, AKI due to cardiac procedures, and acute and chronic MCS effects and complications. Durable MCS, with implantable continuous flow pumps, is used for long-term support in advanced heart failure refractory to guideline-directed medical and device therapy, either permanently or as a bridge to heart transplantation. Temporary MCS-encompassing in this review intra-aortic balloon pumps (IABP), axial flow pumps, centrifugal flow pumps, and venoarterial ECMO-is used for diverse situations: high-risk percutaneous coronary interventions (PCI), acute decompensated heart failure, cardiogenic shock, and resuscitation after cardiac arrest. The wide adoption of MCS makes it imperative to improve understanding of the effects of MCS on kidney health/function and of kidney health/function on MCS outcomes. The complex structure and functions of the kidney, and the complex health states of individuals receiving MCS, makes investigations in this area challenging, and current knowledge is limited. Fortunately, the increasing nephrology toolbox of noninvasive kidney health/function assessments may enable development and testing of individualized management strategies and therapeutics in the future. We review technology, epidemiology, pathophysiology, clinical considerations, and future directions in MCS and nephrology.


Asunto(s)
Lesión Renal Aguda , Insuficiencia Cardíaca , Nefrología , Intervención Coronaria Percutánea , Lesión Renal Aguda/terapia , Insuficiencia Cardíaca/terapia , Humanos , Contrapulsador Intraaórtico
11.
J Artif Organs ; 25(1): 16-23, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33982206

RESUMEN

Left ventricular assist devices (LVADs) are increasingly used as destination therapy or as a bridge to future cardiac transplant in patients with end-stage heart failure. Extracorporeal membrane oxygenation (ECMO) can be used to bridge patients in cardiogenic shock or with decompensated heart failure to durable mechanical circulatory support. We assessed outcomes in patients in critical cardiogenic shock (Interagency Registry for Mechanically Assisted Circulatory Support [INTERMACS] profile 1) who underwent implantation of a continuous-flow (CF)-LVAD, with or without preoperative ECMO bridging. For this retrospective study, we selected INTERMACS profile 1 patients who underwent CF-LVAD implantation at our institution between Sep 1, 2004 and Nov 30, 2018. Of 768 patients identified, 133 (17.3%) were INTERMACS profile 1; 26 (19.5%) received preoperative ECMO support, and 107 (80.5%) did not. Postimplantation outcomes were compared between the ECMO and no-ECMO groups. No significant differences were found in 30-day mortality (15.4 vs. 15.9%, P = 0.95) or survival at 1 year (53.8 vs. 60.9%, P = 0.51). Three patients who received ECMO before CF-LVAD implantation subsequently underwent cardiac transplant. In the ECMO group, the lactate level 1 day after ECMO initiation was lower in survivors than nonsurvivors (2.7 ± 2.2 vs. 7.4 ± 4.2 mmol/L, P = 0.02; area under the curve = 0.85, P = 0.01) after CF-LVAD implantation. Bridging with ECMO to CF-LVAD implantation in carefully selected INTERMACS profile 1 patients (those who are at the highest risk for critical cardiogenic shock and for whom palliation may be the only other option) produced acceptable postoperative outcomes.Field of research: Artificial lung/ECMO.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/cirugía , Humanos , Sistema de Registros , Estudios Retrospectivos , Choque Cardiogénico/cirugía , Resultado del Tratamiento
12.
Interact Cardiovasc Thorac Surg ; 34(3): 470-477, 2022 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-34966937

RESUMEN

OBJECTIVES: Dialysis is considered a contraindication to continuous-flow left ventricular assist device (CF-LVAD) implantation. We evaluated clinical outcomes and survival in carefully selected, low-risk patients with renal failure who required dialysis before CF-LVAD implantation. METHODS: We extracted medical record data of patients who underwent CF-LVAD placement at our centre between 1 January 2006 and 31 August 2017, with 2 clinical scenarios: those who required long-term (>14 days) dialysis and those who required short-term (≤14 days) dialysis immediately before implantation. Demographic, clinical and intraoperative characteristics and survival outcomes were assessed. RESULTS: Of 621 patients who underwent CF-LVAD implantation during the study period, 31 underwent dialysis beforehand. Of these, 17 required long-term dialysis (13 haemodialysis, 4 peritoneal dialysis), and 14 underwent short-term haemodialysis. Compared with the long-term dialysis patients, the short-term dialysis patients were more likely to be Interagency Registry for Mechanically Assisted Circulatory Support profile 1-2 (92.9% vs 70.6%; P < 0.001), to have needed preoperative mechanical circulatory support (78.6% vs 70.6%; P < 0.01) and to have higher in-hospital mortality (85.7% vs 29.4%; P = 0.01). Patients stable on long-term dialysis had acceptable overall survival and markedly better 6-month and 1-year survival than those with short-term dialysis before implantation (64.7% vs 14.3% and 58.8% vs 7.1%, respectively; P < 0.001). CONCLUSIONS: Carefully selected patients who are stable on long-term dialysis have acceptable survival rates after CF-LVAD implantation. Patients with acute renal failure had much poorer outcomes than those with chronic end-stage renal disease.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Humanos , Diálisis Renal/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
Tex Heart Inst J ; 48(4)2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34468765

RESUMEN

To determine whether the cause of cardiomyopathy affects outcomes in patients who undergo continuous-flow left ventricular assist device support, we compared postimplant adverse events and survival between patients with ischemic and nonischemic cardiomyopathy. The inclusion criteria for the ischemic group were a history of myocardial infarction or revascularization (coronary artery bypass grafting or percutaneous coronary intervention), ≥75% stenosis of the left main or proximal left anterior descending coronary artery, or ≥75% stenosis of ≥2 epicardial vessels. From November 2003 through March 2016, 526 patients underwent device support: 256 (48.7%) in the ischemic group and 270 (51.3%) in the nonischemic group. The ischemic group was older (60.0 vs 50.0 yr), included more men than women (84.0% vs 72.6%), and had more comorbidities. More patients in the nonischemic group were able to have their devices explanted after left ventricular recovery (5.9% vs 2.0%; P=0.02). More patients in the ischemic group had gastrointestinal bleeding (31.2% vs 22.6%; P=0.03), particularly from arteriovenous malformations (20.7% vs 11.9%; P=0.006) and ulcers (16.4% vs 9.3%; P=0.01). Kaplan-Meier analysis revealed no difference in overall survival between groups (P=0.24). Older age, previous sternotomy, higher total bilirubin level, and concomitant procedures during device implantation independently predicted death (P ≤0.03), whereas cause of heart failure did not (P=0.08). Despite the similarity in overall survival between groups, ischemic cardiomyopathy was associated with more frequent gastrointestinal bleeding. This information may help guide the care of patients with ischemic cardiomyopathy who receive continuous-flow left ventricular assist device support.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Corazón Auxiliar , Isquemia Miocárdica , Anciano , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Cardiomiopatías/terapia , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Humanos , Masculino , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/terapia , Estudios Retrospectivos , Resultado del Tratamiento
14.
Genet Med ; 23(12): 2404-2414, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34363016

RESUMEN

PURPOSE: Cardiovascular disease (CVD) is the leading cause of death in adults in the United States, yet the benefits of genetic testing are not universally accepted. METHODS: We developed the "HeartCare" panel of genes associated with CVD, evaluating high-penetrance Mendelian conditions, coronary artery disease (CAD) polygenic risk, LPA gene polymorphisms, and specific pharmacogenetic (PGx) variants. We enrolled 709 individuals from cardiology clinics at Baylor College of Medicine, and samples were analyzed in a CAP/CLIA-certified laboratory. Results were returned to the ordering physician and uploaded to the electronic medical record. RESULTS: Notably, 32% of patients had a genetic finding with clinical management implications, even after excluding PGx results, including 9% who were molecularly diagnosed with a Mendelian condition. Among surveyed physicians, 84% reported medical management changes based on these results, including specialist referrals, cardiac tests, and medication changes. LPA polymorphisms and high polygenic risk of CAD were found in 20% and 9% of patients, respectively, leading to diet, lifestyle, and other changes. Warfarin and simvastatin pharmacogenetic variants were present in roughly half of the cohort. CONCLUSION: Our results support the use of genetic information in routine cardiovascular health management and provide a roadmap for accompanying research.


Asunto(s)
Cardiología , Enfermedades Cardiovasculares , Adulto , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/genética , Enfermedades Cardiovasculares/terapia , Pruebas Genéticas , Humanos , Farmacogenética/métodos , Pruebas de Farmacogenómica , Estados Unidos
15.
Tex Heart Inst J ; 48(2)2021 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-34111275

RESUMEN

Continuous-flow left ventricular assist devices have proved to be effective, durable, life-saving tools in patients with end-stage heart failure. However, because of the risks associated with mechanical circulatory support (including stroke, infection, gastrointestinal bleeding, and device malfunction), the optimal goal of device therapy is myocardial recovery and device removal. Ventricular reconditioning and pump explantation after continuous-flow support have been reported; however, little is known about variables that govern the pace and degree of myocardial response in patients who experience such recovery. We describe our long-term pump-weaning strategy for a 25-year-old man who had a continuous-flow device implanted and then needed more than 5 years of support from it before developing cardiac reserve sufficient to enable pump explantation. To our knowledge, this is the longest period of uninterrupted continuous-flow device support to end in successful pump deactivation and a return to medical therapy. This case highlights the importance of actively and persistently pursuing a device-weaning strategy in all patients who need left ventricular assist device therapy.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Adulto , Remoción de Dispositivos , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Resultado del Tratamiento
16.
Ann Thorac Cardiovasc Surg ; 27(1): 64-67, 2021 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-30101823

RESUMEN

An increasing number of children with congenital heart disease are surviving into adulthood and subsequently developing end-stage heart failure. Two example populations are adults who have been previously operated on for congenitally corrected transposition of the great arteries (CCTGA) and transposition of the great arteries (TGA). Implantation of a continuous flow left ventricular assist device (CF-LVAD) in these patients can present unusual anatomical and physiologic challenges. In this report, we describe outcomes of CF-LVAD implantation in three such patients. These cases demonstrate the feasibility of implanting a CF-LVAD in patients who have undergone surgery for CCTGA and/or TGA.


Asunto(s)
Operación de Switch Arterial , Transposición Congénitamente Corregida de las Grandes Arterias/cirugía , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Implantación de Prótesis/instrumentación , Función Ventricular Izquierda , Adulto , Operación de Switch Arterial/efectos adversos , Transposición Congénitamente Corregida de las Grandes Arterias/complicaciones , Transposición Congénitamente Corregida de las Grandes Arterias/diagnóstico por imagen , Transposición Congénitamente Corregida de las Grandes Arterias/fisiopatología , Resultado Fatal , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Trasplante de Corazón , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Derecha
17.
Ann Thorac Cardiovasc Surg ; 27(3): 211-214, 2021 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-30158391

RESUMEN

Mechanical circulatory support may result in sufficient myocardial recovery to allow for explantation of the left ventricular assist device (LVAD). The duration of support associated with left ventricular recovery has generally been 6-12 months. In this report, we present a patient in whom the left ventricle recovered after 5 years of support with a LVAD. Our report demonstrates that long-term monitoring for left ventricular recovery is prudent and may allow for late device explantation.


Asunto(s)
Remoción de Dispositivos , Corazón Auxiliar , Miocarditis/terapia , Implantación de Prótesis/instrumentación , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Adulto , Humanos , Masculino , Miocarditis/diagnóstico , Miocarditis/fisiopatología , Miocarditis/virología , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología
18.
Interact Cardiovasc Thorac Surg ; 30(1): 47-53, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31535130

RESUMEN

OBJECTIVES: Some patients who undergo continuous-flow left ventricular assist device (CF-LVAD) implantation require concomitant procedures that can be performed with or without cardiac arrest under aortic cross-clamping (AXC). Procedures normally performed with cardiac arrest are sometimes avoided or performed without cardiac arrest because it may be detrimental to right heart function. However, the effects of cardiac arrest on patients with advanced heart failure necessitating CF-LVAD support have not been thoroughly studied. We examined our single-centre experience to determine whether cardiac arrest during CF-LVAD implantation was associated with worse patient outcomes. METHODS: From November 2003 to March 2016, a total of 526 patients with chronic end-stage heart failure underwent primary CF-LVAD implantation. Preoperative demographics, postoperative complications and mortality rates were compared between patients who required cardiac arrest with AXC (n = 50) and those who did not (n = 476). RESULTS: The most frequently performed procedure requiring AXC was aortic valve closure (n = 23, 26.1%). Although the AXC group had longer cardiopulmonary bypass times (P < 0.01), long-term (5-year) survival was similar in AXC and non-AXC patients (P = 0.13). Also, postoperative right heart failure (P = 0.15) and neurological dysfunction (P = 0.89) rates were not significantly different between the 2 groups. Cox proportional hazards analysis showed that cardiac arrest with AXC was not an independent predictor of mortality (hazard ratio, 0.89; P = 0.73). CONCLUSIONS: Cardiac arrest with AXC during CF-LVAD implantation did not negatively affect long-term survival or the incidence of right ventricular failure or stroke. These findings should be considered in deciding surgical strategies. Additional investigation may be warranted to further understand the effects of cardiac arrest during LVAD implantation.


Asunto(s)
Aorta/cirugía , Paro Cardíaco Inducido , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Complicaciones Posoperatorias/epidemiología , Adulto , Anciano , Aorta/fisiopatología , Constricción , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
19.
ASAIO J ; 66(3): 283-290, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-30973400

RESUMEN

The number of patients on destination therapy is increasing as long-term survival on continuous-flow left ventricular assist device (CF-LVAD) therapy has improved. Gastrointestinal bleeding (GIB) is a common complication after CF-LVAD implantation, and its risk correlates with longer support time, emphasizing the importance of GIB management. The lower pulsatility of CF-LVADs may promote arteriovenous malformations, which amplify the bleeding risk. Here, we retrospectively analyzed the location, incidence, and survival effect of GIB events in HeartMate II (HM-II) and HeartWare Ventricular Assist Device (HVAD) recipients to provide specific details regarding these complications. From November 2003 to March 2016, 526 patients with chronic heart failure underwent primary implantation of an HM-II (n = 403) or HVAD (n = 123) CF-LVAD at our center. Of the 526 patients, 140 (26.6%) had a GIB event (HM-II: n = 100; HVAD: n = 40), 92 (17.5%) had a single GIB event, and 48 (9.1%) had multiple GIB events (range: 2-9 events). HVAD recipients had a higher incidence of both upper and lower GIB events (p < 0.001 and P = 0.002, respectively) than HM-II recipients. Arteriovenous malformation was the most common etiology for GIB (50 patients/72 events); for this group, the average time-to-event was 300.4 days, the recurrence rate was 34%, and the 90-day and 1-year survival rates were 88.3% and 66.7%, respectively. Age at implantation was the only predictor of GIB. In conclusion, our study provides detailed information about GIB events associated with current CF-LVADs. Additional studies are required to evaluate strategies to reduce the incidence of GIB morbidity.


Asunto(s)
Hemorragia Gastrointestinal/etiología , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Adulto , Anciano , Malformaciones Arteriovenosas/complicaciones , Femenino , Hemorragia Gastrointestinal/epidemiología , Insuficiencia Cardíaca/mortalidad , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
20.
ASAIO J ; 66(1): 64-68, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-30507849

RESUMEN

Implantable continuous-flow left ventricular assist devices (CF-LVADs) are used for long-term LV support in bridging patients to heart transplantation or as destination therapy. With prolonged support times, some patients will have repeat complications necessitating multiple device exchanges. To elucidate the safety and efficacy of repeat device exchange, we retrospectively reviewed data from 25 patients who underwent two or more CF-LVAD implantations between July 2005 and August 2017. Indications for exchange were thrombus/hemolysis (n = 8, 32%), electromechanical device malfunction (n = 14, 56%), and infection (n = 3, 12%). The implanted devices were the HeartMate II (n = 13, 52%), the HeartWare HVAD (n = 11, 44%), and the Jarvik 2000 (n = 1, 4%). Average hospital length of stay was 44 days (range 4-221 days), and 17 patients (68%) survived to discharge. Average duration of support after the most recent LVAD implantation was 802 days (range 1-3,229 days). Overall survival was 72% at 1 year and 60% at 2 years. Postoperative complications included respiratory failure in five patients (20%), device infection in five (20%), bleeding requiring reoperation in four (16%), neurologic dysfunction in four (16%), and acute renal failure in two (8%). Overall, our data suggest that repeat LVAD exchange is a feasible option for patients with recurrent device-related complications.


Asunto(s)
Corazón Auxiliar , Reoperación/mortalidad , Adolescente , Adulto , Anciano , Femenino , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Reoperación/efectos adversos , Reoperación/métodos , Estudios Retrospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...