Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 95(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38573050

RESUMEN

A study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer to be 630 ± 110 nm. The relative light outputs from the decay of 241Am and Compton scattering of electrons were used to extract Birks' law coefficient, yielding a kB value of 0.087 ± 0.003 mm/MeV, consistent with some previous reports for other polystyrene-based scintillators. The results from these measurements are incorporated into the simulation to show that an energy threshold of (∼9 keV) can be achieved for the UCNProBe experiment. This low threshold enables high beta particle detection efficiency and the indirect measurement of UCN. The ability to make the scintillator deuterated, accompanied by its relatively thin dead layer, gives rise to unique applications in a wide range of UCN experiments, where it can be used to trap UCN and detect charged particles in situ.

2.
AJNR Am J Neuroradiol ; 44(8): 951-958, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37414455

RESUMEN

BACKGROUND AND PURPOSE: Traumatic brachial plexus injuries are uncommon but can be debilitating. Early diagnosis is critical. Most patients undergo CT after trauma. We sought to identify correlative CT findings of supraclavicular brachial plexus injuries to discern who may require further evaluation with MR imaging and to measure multireviewer performance for their interpretations. MATERIALS AND METHODS: We identified all MR imaging examinations of the brachial plexus from our institution from January 2010 to January 2021 and included those performed for trauma. We excluded patients with penetrating or infraclavicular injuries and without preceding CTA of the neck or CT of the cervical spine. The cohort of 36 cases and 50 controls remained for analysis and were assessed for 6 findings: scalene muscle edema/enlargement, interscalene fat pad effacement, first rib fracture, cervical spine lateral mass/transverse process fracture, extra-axial cervical spinal hemorrhage, and cervical spinal cord eccentricity, forming a reference key. A resident physician and 2 neuroradiologists (blinded to the MR imaging) independently reviewed each CT scan for these findings. We measured agreement (Cohen κ) between observers and against the reference key. RESULTS: Interscalene fat pad effacement (sensitivity, specificity, 94.44%, 90.00%; OR = 130.33; P < .001) and scalene muscle edema/enlargement (sensitivity, specificity, 94.44%, 88.00%; OR = 153.00; P < .001) correlated significantly with brachial plexus injury. Agreement between observers and the key was almost perfect for those findings and fractures (pooled κ ≥ 0.84; P < .001). Agreement between observers was variable (κ = 0.48-0.97; P < .001). CONCLUSIONS: CT can accurately predict brachial plexus injuries, potentially enabling earlier definitive evaluation. High interobserver agreement suggests that findings are consistently learned and applied.


Asunto(s)
Plexo Braquial , Heridas no Penetrantes , Humanos , Estudios Retrospectivos , Plexo Braquial/diagnóstico por imagen , Heridas no Penetrantes/complicaciones , Heridas no Penetrantes/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Vértebras Cervicales/lesiones
3.
Phys Rev Lett ; 127(16): 162501, 2021 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-34723594

RESUMEN

We report an improved measurement of the free neutron lifetime τ_{n} using the UCNτ apparatus at the Los Alamos Neutron Science Center. We count a total of approximately 38×10^{6} surviving ultracold neutrons (UCNs) after storing in UCNτ's magnetogravitational trap over two data acquisition campaigns in 2017 and 2018. We extract τ_{n} from three blinded, independent analyses by both pairing long and short storage time runs to find a set of replicate τ_{n} measurements and by performing a global likelihood fit to all data while self-consistently incorporating the ß-decay lifetime. Both techniques achieve consistent results and find a value τ_{n}=877.75±0.28_{stat}+0.22/-0.16_{syst} s. With this sensitivity, neutron lifetime experiments now directly address the impact of recent refinements in our understanding of the standard model for neutron decay.

4.
Rev Sci Instrum ; 92(2): 023305, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33648127

RESUMEN

In this paper, we report studies of the Fermi potential and loss per bounce of ultracold neutrons (UCNs) on a deuterated scintillator (Eljen-299-02D). These UCN properties of the scintillator enable its use in a wide variety of applications in fundamental neutron research.

5.
Phys Rev Lett ; 121(2): 022505, 2018 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-30085691

RESUMEN

Fornal and Grinstein recently proposed that the discrepancy between two different methods of neutron lifetime measurements, the beam and bottle methods, can be explained by a previously unobserved dark matter decay mode, n→X+γ. We perform a search for this decay mode over the allowed range of energies of the monoenergetic γ ray for X to be dark matter. A Compton-suppressed high-purity germanium detector is used to identify γ rays from neutron decay in a nickel-phosphorous-coated stainless-steel bottle. A combination of Monte Carlo and radioactive source calibrations is used to determine the absolute efficiency for detecting γ rays arising from the dark matter decay mode. We exclude the possibility of a sufficiently strong branch to explain the lifetime discrepancy with 97% confidence.

6.
Science ; 360(6389): 627-632, 2018 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-29731449

RESUMEN

The precise value of the mean neutron lifetime, τn, plays an important role in nuclear and particle physics and cosmology. It is used to predict the ratio of protons to helium atoms in the primordial universe and to search for physics beyond the Standard Model of particle physics. We eliminated loss mechanisms present in previous trap experiments by levitating polarized ultracold neutrons above the surface of an asymmetric storage trap using a repulsive magnetic field gradient so that the stored neutrons do not interact with material trap walls. As a result of this approach and the use of an in situ neutron detector, the lifetime reported here [877.7 ± 0.7 (stat) +0.4/-0.2 (sys) seconds] does not require corrections larger than the quoted uncertainties.

7.
Rev Sci Instrum ; 88(5): 053508, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28571423

RESUMEN

In this paper, we describe a new method for measuring surviving neutrons in neutron lifetime measurements using bottled ultracold neutrons (UCN), which provides better characterization of systematic uncertainties and enables higher precision than previous measurement techniques. An active detector that can be lowered into the trap has been used to measure the neutron distribution as a function of height and measure the influence of marginally trapped UCN on the neutron lifetime measurement. In addition, measurements have demonstrated phase-space evolution and its effect on the lifetime measurement.

8.
Rev Sci Instrum ; 87(4): 045113, 2016 04.
Artículo en Inglés | MEDLINE | ID: mdl-27131713

RESUMEN

We have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and ∼600 Torr. The apparatus can house a set of electrodes that are 12 cm in diameter with a gap of 1-2 cm between them, and a potential up to ±50 kV can be applied to each electrode. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes 12 cm in diameter for a wide range of pressures at 0.4 K. We also measured the current between two electrodes. Our initial results, I < 1 pA at 45 kV, correspond to a lower bound on the effective volume resistivity of liquid helium of ρV > 5 × 10(18) Ω cm. This lower bound is 5 times larger than the bound previously measured. We report the design, construction, and operational experience of the apparatus, as well as initial results.

9.
Phys Rev Lett ; 110(1): 012504, 2013 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-23383785

RESUMEN

The MuCap experiment at the Paul Scherrer Institute has measured the rate Λ(S) of muon capture from the singlet state of the muonic hydrogen atom to a precision of 1%. A muon beam was stopped in a time projection chamber filled with 10-bar, ultrapure hydrogen gas. Cylindrical wire chambers and a segmented scintillator barrel detected electrons from muon decay. Λ(S) is determined from the difference between the µ(-) disappearance rate in hydrogen and the free muon decay rate. The result is based on the analysis of 1.2 × 10(10) µ(-) decays, from which we extract the capture rate Λ(S) = (714.9 ± 5.4(stat) ± 5.1(syst)) s(-1) and derive the proton's pseudoscalar coupling g(P)(q(0)(2) = -0.88 m(µ)(2)) = 8.06 ± 0.55.

10.
Phys Rev Lett ; 99(3): 032001, 2007 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-17678280

RESUMEN

The mean life of the positive muon has been measured to a precision of 11 ppm using a low-energy, pulsed muon beam stopped in a ferromagnetic target, which was surrounded by a scintillator detector array. The result, tau(micro)=2.197 013(24) micros, is in excellent agreement with the previous world average. The new world average tau(micro)=2.197 019(21) micros determines the Fermi constant G(F)=1.166 371(6)x10(-5) GeV-2 (5 ppm). Additionally, the precision measurement of the positive-muon lifetime is needed to determine the nucleon pseudoscalar coupling g(P).

11.
Phys Rev Lett ; 99(3): 032002, 2007 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-17678281

RESUMEN

The rate of nuclear muon capture by the proton has been measured using a new technique based on a time projection chamber operating in ultraclean, deuterium-depleted hydrogen gas, which is key to avoiding uncertainties from muonic molecule formation. The capture rate from the hyperfine singlet ground state of the microp atom was obtained from the difference between the micro(-) disappearance rate in hydrogen and the world average for the micro(+) decay rate, yielding Lambda(S)=725.0+/-17.4 s(-1), from which the induced pseudoscalar coupling of the nucleon, g(P)(q(2)=-0.88m(2)(micro))=7.3+/-1.1, is extracted.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...