Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Circulation ; 104(16): 1917-22, 2001 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-11602494

RESUMEN

BACKGROUND: Determination of fractional flow reserve (FFR) has been proposed as a means to assess stent deployment. In this prospective, multicenter trial, we evaluate the use of FFR to optimize stenting by comparing it with standard intravascular ultrasound (IVUS) criteria. METHODS AND RESULTS: Eighty-four stable patients with isolated coronary lesions underwent coronary stent deployment starting at 10 atm and increased serially by 2 atm until the FFR was >/=0.94 or 16 atm was achieved. IVUS was then performed. FFR was measured with a coronary pressure wire with intracoronary adenosine to induce hyperemia. The diagnostic characteristics of an FFR <0.94 to predict suboptimal stent expansion by IVUS, defined in both absolute and relative terms, were calculated. Over a range of IVUS criteria, the highest sensitivity, specificity, and predictive accuracy of FFR were 80%, 30%, and 42%, respectively. Receiver operator characteristic analysis defined an optimal FFR cut point at >/=0.96; at this threshold, the sensitivity, specificity, and predictive accuracy of FFR were 75%, 58%, and 62%, respectively (P=0.03 for comparison of predictive accuracy, P=0.01 for concordance between FFR and IVUS). The negative predictive value was 88%. Significantly better diagnostic performance was achieved in a subgroup that received higher doses (>30 microgram) of intracoronary adenosine during pressure measurements, suggesting that FFR might be overestimated in the other group. CONCLUSIONS: A fractional flow reserve <0.96, measured after stent deployment, predicts a suboptimal result based on validated intravascular ultrasound criteria; however, an FFR >/=0.96 does not reliably predict an optimal stent result. Higher doses of intracoronary adenosine than previously used to measure FFR improve these results.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Implantación de Prótesis Vascular/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Ultrasonografía Intervencional , Adenosina , Velocidad del Flujo Sanguíneo , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Vasos Coronarios/cirugía , Femenino , Humanos , Funciones de Verosimilitud , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad , Stents , Resultado del Tratamiento
2.
Am Heart J ; 141(4): 684-90, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11275938

RESUMEN

BACKGROUND: Although activation of the complement system in myocardial infarction and cardiopulmonary bypass has been shown to contribute to myocardial injury, its role in congestive heart failure (CHF) is unknown. The purpose of this study was to determine the presence of terminal complement activation and its relation to clinical outcomes in patients with CHF. METHODS: We measured serum levels of the terminal complement complex C5b-9 in 36 patients with symptomatic heart failure and left ventricular ejection fraction <40%. We compared the serum C5b-9 levels of these patients with CHF with a group of 12 age-matched control patients. Combined clinical outcomes (death, urgent heart transplantation, or hospitalization with worsening heart failure) at 6 months were determined. RESULTS: The serum C5b-9 [median (25th to 75th percentiles)] levels in 36 patients with CHF [101.5 ng/mL (40 to 164)] were significantly (P =.003) higher than in the 12 control patients [36.5 ng/mL (22 to 50)]. Significantly more of the patients with CHF with the highest levels of C5b-9 (highest 50th percentile) had New York Heart Association class IV symptoms (67% vs 33%; P =.04) and adverse clinical outcomes by 6 months (56% vs 17%; P =.02) compared with the patients with CHF with lower levels (lowest 50th percentile). CONCLUSIONS: We have described a significant elevation in circulating C5b-9, the terminal complement complex, in patients with symptomatic heart failure and have observed an association between high levels of C5b-9 and near-term adverse events.


Asunto(s)
Activación de Complemento , Complejo de Ataque a Membrana del Sistema Complemento/análisis , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/fisiopatología , Anciano , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Factor de Necrosis Tumoral alfa/análisis
3.
Circulation ; 102(5): 523-30, 2000 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-10920064

RESUMEN

BACKGROUND: Intravascular ultrasound (IVUS) can assess stent geometry more accurately than angiography. Several studies have demonstrated that the degree of stent expansion as measured by IVUS directly correlated to clinical outcome. However, it is unclear if routine ultrasound guidance of stent implantation improves clinical outcome as compared with angiographic guidance alone. METHODS AND RESULTS: The CRUISE (Can Routine Ultrasound Influence Stent Expansion) study, a multicenter study IVUS substudy of the Stent Anti-thrombotic Regimen Study, was designed to assess the impact of IVUS on stent deployment in the high-pressure era. Nine centers were prospectively assigned to stent deployment with the use of ultrasound guidance and 7 centers to angiographic guidance alone with documentary (blinded) IVUS at the conclusion of the procedure. A total of 525 patients were enrolled with completed quantitative coronary angiography, quantitative coronary ultrasound, and clinical events adjudicated at 9 months for 499 patients. The IVUS-guided group had a larger minimal lumen diameter (2.9+/-0.4 versus 2.7+/-0. 5 mm, P<0.001) by quantitative coronary angiography and a larger minimal stent area (7.78+/-1.72 versus 7.06+/-2.13 mm(2), P<0.001) by quantitative coronary ultrasound. Target vessel revascularization, defined as clinically driven repeat interventional or surgical therapy of the index vessel at 9 month-follow-up, occurred significantly less frequently in the IVUS-guided group (8.5% versus 15.3%, P<0.05; relative reduction of 44%). CONCLUSIONS: These data suggest that ultrasound guidance of stent implantation may result in more effective stent expansion compared with angiographic guidance alone.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents , Ultrasonografía Intervencional , Aspirina , Angiografía Coronaria , Enfermedad Coronaria/mortalidad , Cumarinas/uso terapéutico , Femenino , Fibrinolíticos/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Ticlopidina/uso terapéutico , Resultado del Tratamiento
4.
J Am Coll Cardiol ; 31(7): 1555-60, 1998 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-9626834

RESUMEN

OBJECTIVES: The present study examined the association of estrogen (E2) and the inflammatory response of endothelium in coronary artery disease (CAD) by measuring circulating cellular adhesion molecules (cCAMs) in subjects with atherosclerosis. BACKGROUND: Atherosclerotic plaque demonstrates features similar to inflammation. Endothelial cell activation by inflammatory cytokines induces expression of cellular adhesion molecules (CAMs), thereby perhaps augmenting leukocyte adhesion and recruitment and subsequent development of atherosclerosis. The incidence of CAD is lower in women; this may be due to the cardioprotective effects of E2. METHODS: Consecutive eligible subjects with CAD admitted for cardiac catheterization were studied. The groups evaluated were men, postmenopausal women receiving E2 replacement therapy (ERT), postmenopausal women not receiving ERT and premenopausal women. Control groups included men and women without CAD. Preprocedural blood samples were drawn from all groups. Measurements of cCAMs, E-selectin, vascular cell adhesion molecule-1 (VCAM-1) and intercellular adhesion molecule-1 were performed by enzyme-linked immunoabsorbant assay. E2 levels were assessed by radioimmunoassay. RESULTS: We observed a statistically significant increase in all cCAMs in men with CAD and postmenopausal women with CAD not receiving ERT compared with postmenopausal women with CAD receiving ERT. Premenopausal women with CAD and postmenopausal women with CAD receiving ERT had a significant increase in VCAM-1 alone compared with the female control group. CONCLUSIONS: A possible mechanism by which E2 exerts one of its cardioprotective effects is by limiting the inflammatory response to injury by modulating the expression of CAMs from the endothelium.


Asunto(s)
Moléculas de Adhesión Celular/sangre , Enfermedad de la Arteria Coronaria/sangre , Endotelio Vascular/inmunología , Terapia de Reemplazo de Estrógeno , Estrógenos/farmacología , Adulto , Enfermedad de la Arteria Coronaria/fisiopatología , Endotelio Vascular/efectos de los fármacos , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Masculino , Persona de Mediana Edad , Posmenopausia/fisiología , Radioinmunoensayo
5.
Am J Cardiol ; 80(10A): 60K-67K, 1997 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-9409693

RESUMEN

High-speed rotational atherectomy (RA) is a new percutaneous procedure for treatment of coronary stenoses that operates by the unique mechanism of plaque abrasion. This article reports acute (in-hospital) outcomes and 1-year follow-up in a large cohort of patients treated with this device by NACI investigators. A total of 525 patients with 670 lesions treated with RA form the substrate of this report. Patients tended to be older (mean age 64.8 years) than those in previously reported series of percutaneous transluminal coronary angioplasty (PTCA), with more extensive disease and more complex lesions. Calcification was present in 54% of lesions, and eccentricity in 41%. Balloon angioplasty postdilation was performed after RA in 88% of cases. Angiographic and procedural success (angiographic success without death, Q-wave myocardial infarction [MI] or emergency coronary artery bypass graft [CABG] surgery) rates were 89% and 88%, respectively. Acute in-hospital events included 4 deaths (1%) and 1 emergency CABG surgery (0.4%). MI occurred in 6% of patients, consisting predominantly of non-Q-wave MI (5%). After RA, angiographic complications included coronary dissection (12%), abrupt closure (5%), side branch occlusion (3%), and distal embolization (3%). Most of these were resolved after postdilation except for coronary dissection, which was present in 15% of lesions treated. Mean length of stay was 3 days. At 1-year follow-up, 27% of patients required target lesion revascularization and 30% had experienced death, Q-wave MI, or target lesion revascularization. Preprocedural characteristics that independently predicted 1-year death, Q-wave MI, or target lesion revascularization were male gender, high risk for surgery, target lesions that were proximal to or in bifurcations, eccentric, long, or highly stenosed. RA, even when applied to lesions of traditionally unfavorable morphology, appears to provide reasonable procedural and angiographic success rates. Restenosis and progression of disease contribute to subsequent clinical and procedural events.


Asunto(s)
Aterectomía Coronaria/métodos , Enfermedad Coronaria/terapia , Sistema de Registros , Anciano , Aterectomía Coronaria/instrumentación , Aterectomía Coronaria/estadística & datos numéricos , Angiografía Coronaria , Enfermedad Coronaria/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Valor Predictivo de las Pruebas
6.
Am J Cardiol ; 80(10A): 78K-88K, 1997 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-9409695

RESUMEN

The randomized Stent Restenosis Study (STRESS) and Belgium Netherlands Stent (Benestent) trials established that elective use of Palmaz-Schatz stents (PSSs) in native coronary arteries with de novo lesions is associated with increased procedural success and reduced restenosis. However there are other clinical indications for which stents are commonly used (unplanned use, vein grafts, restenosis lesions) that are not addressed in these studies. From 1990-1992, 688 lesions in 628 patients were treated with PSSs in the New Approaches to Coronary Intervention (NACI) registry. Angiographic core laboratory readings were available for 543 patients (595 lesions, of which 106 were stented for unplanned indications, 239 were in saphenous vein bypass grafts, and 296 were previously treated). The cohort of patients in whom stents were placed for unplanned indications had more women, current smokers, and had a higher incidence of recent myocardial infarction (MI). Patients who underwent stenting of saphenous vein grafts were older, had a higher incidence of diabetes mellitus, unstable angina, prior MI, and congestive heart failure. Lesion success was similar in all cohorts (98%), but procedural success was significantly higher for planned stenting (96% vs 87%; p < 0.01). Predictors of adverse events in-hospital were presence of a significant left main stenosis and stenting for unplanned indication. The incidence of target lesion revascularization by 30 days was significantly higher for patients undergoing unplanned stenting due to a higher risk for stent thrombosis. Recent MI, stenting in native lesion, and small postprocedural minimum lumen diameter independently predicted target lesion revascularization at 30 days. Independent predictors of death, Q-wave myocardial infarction, or target lesion revascularization at 1 year included severe concomitant disease, high risk for surgery, left main disease, stenting in the left main coronary artery, and low postprocedure minimum lumen diameter.


Asunto(s)
Enfermedad Coronaria/terapia , Sistema de Registros , Stents/estadística & datos numéricos , Anciano , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/mortalidad , Diseño de Equipo , Estudios de Evaluación como Asunto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Revascularización Miocárdica/estadística & datos numéricos , Factores de Riesgo , Resultado del Tratamiento
7.
Circulation ; 94(4): 629-35, 1996 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-8772681

RESUMEN

BACKGROUND: In the EPIC trial, c7E3 Fab, an antiplatelet IIb/ IIIa receptor antibody, reduced 30-day ischemic end points after high-risk coronary angioplasty by 35% and 6-month ischemic events by 23% but increased in-hospital bleeding episodes. METHODS AND RESULTS: Of the 2099 patients randomized in EPIC, data were collected on 2038 (97%) for prospective hospital cost and major resources. Physician fees were estimated from the Medicare Fee Schedule. Regression analysis was used to examine the economic tradeoff between reduced ischemic events and increased major bleeding during the initial hospitalization. A potential cost savings of $622 per patient during the initial hospitalization from reduced acute ischemic events with c7E3 Fab was offset by an equivalent rise ($521) in costs as the result of an increase in bleeding episodes. Baseline medical costs for the bolus and infusion c7E3 Fab arm averaged $13,577 (exclusive of drug cost) compared with $13,434 for placebo (P = .42). During the 6-month follow-up, c7E3 Fab decreased repeat hospitalization rates by 23% (P = .004) and repeat revascularization by 22% (P = .04), producing a mean $1270 savings per patient (exclusive of drug cost) (P = .018). With a cost of $1407 for the bolus and infusion c7E3 Fab regimen, the cumulative net 6-month cost to switch from standard care to routine c7E3 Fab averaged $293 per patient. CONCLUSIONS: In high-risk coronary angioplasty, aggressive platelet inhibition with c7E3 Fab, by significantly reducing ischemic events and repeat revascularization, recoups most of the cost of therapy and has the potential to pay for itself.


Asunto(s)
Angioplastia/efectos adversos , Anticuerpos Monoclonales/uso terapéutico , Fragmentos Fab de Inmunoglobulinas/uso terapéutico , Isquemia Miocárdica/terapia , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores , Abciximab , Anciano , Angioplastia/economía , Anticuerpos Monoclonales/administración & dosificación , Anticoagulantes/uso terapéutico , Aspirina/uso terapéutico , Transfusión Sanguínea , Costos y Análisis de Costo , Método Doble Ciego , Femenino , Heparina/uso terapéutico , Humanos , Fragmentos Fab de Inmunoglobulinas/administración & dosificación , Infusiones Intravenosas , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/inmunología , Recurrencia , Stents , Resultado del Tratamiento , Estados Unidos
8.
J Am Coll Cardiol ; 26(3): 704-12, 1995 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-7642863

RESUMEN

OBJECTIVES: This study reports the multicenter registry experience evaluating the safety and efficacy of the Palmaz-Schatz stent in the treatment of saphenous vein graft disease. BACKGROUND: Saphenous vein graft angioplasty is associated with frequent periprocedural complications and a high frequency of restenosis. Stent implantation has been shown to reduce restenosis, with improved long-term outcomes in the treatment of native coronary artery disease. Preliminary experience with stent placement in the treatment of saphenous vein graft lesions has been favorable. METHODS: Twenty U.S. investigator sites enrolled a total of 589 symptomatic patients (624 lesions) for treatment of focal vein graft stenoses between January 1990 and April 1992. Follow-up angiography was performed at 6 months, and the clinical course of all study patients was prospectively collected at regular intervals for up to 12 months. RESULTS: Stent delivery was successful in 98.8% of cases, and the procedural success rate was 97.1%. The lesion diameter stenosis decreased from 82 +/- 12% (mean +/- SD) before to 6.6 +/- 10.2% after treatment. Major in-hospital complications occurred in 17 patients (2.9%); stent thrombosis was found in 8 (1.4%); and major vascular or bleeding complications were noted in 83 (14.3%). Six-month angiographic follow-up revealed an overall restenosis rate (> or = 50% diameter stenosis) of 29.7%. Multivariate logistic regression analysis indicated that 1) restenotic lesions, 2) smaller reference vessel size, 3) history of diabetes mellitus, and 4) higher percent poststent diameter stenosis were independent predictors of restenosis. The 12-month actuarial event-free survival was 76.3%. CONCLUSIONS: Stent implantation in patients with focal saphenous vein graft lesions can be achieved with a high rate of procedural success, acceptable major complications, reduced angiographic restenosis and favorable late clinical outcome compared with historical balloon angioplasty control series. The rigorous anticoagulation regimen after stent placement results in more frequent vascular and other bleeding complications. Future randomized studies comparing standard balloon angioplasty with stent implantation are warranted to properly assess the full impact of stent placement in the treatment of saphenous vein graft lesions.


Asunto(s)
Oclusión de Injerto Vascular/terapia , Vena Safena/trasplante , Stents , Anciano , Anticoagulantes/administración & dosificación , Terapia Combinada , Angiografía Coronaria , Enfermedad Coronaria/complicaciones , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/cirugía , Femenino , Estudios de Seguimiento , Oclusión de Injerto Vascular/complicaciones , Oclusión de Injerto Vascular/diagnóstico por imagen , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Vena Safena/diagnóstico por imagen , Stents/efectos adversos , Stents/estadística & datos numéricos , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
9.
J Am Coll Cardiol ; 24(5): 1207-12, 1994 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-7930240

RESUMEN

OBJECTIVES: The purpose of this study was to examine the long-term clinical and angiographic outcome after coronary stent implantation. BACKGROUND: Previous reports have shown a discordance between the excellent initial angiographic results and subsequent adverse clinical events after coronary artery stenting. METHODS: Single Palmaz-Schatz stents were electively implanted in the native coronary arteries of 300 consecutive patients. Angiograms were obtained at baseline, after balloon angioplasty, after stent implantation and at 6 months after implantation. Films were analyzed by a panel of angiographers utilizing an automated edge detection program. Clinical events, including death, myocardial infarction, coronary bypass surgery and repeat angioplasty, were recorded for 1 year. RESULTS: Although there were no acute in laboratory vessel closures, stent thrombosis occurred in 14 patients (4.7%) at a mean +/- SD of 5 +/- 3 days after implantation. Two hundred fifty-eight (90%) of 286 eligible patients had follow-up angiography at 6.1 +/- 2.2 months after stent implantation. Minimal lumen diameter increased from 0.80 +/- 0.39 mm at baseline to 1.65 +/- 0.51 mm after angioplasty and further increased to 2.55 +/- 0.49 mm after stent placement (p = 0.0001). At follow-up there was a 0.85-mm late loss in lumen diameter, with a final minimal lumen diameter at 6 months of 1.70 +/- 0.71 mm. Restenosis, defined as > or = 50% diameter stenosis at follow-up, occurred in 14% of patients with previously untreated lesions and in 39% of patients with previous angioplasty (p < 0.001). Clinical events after 1 year for the entire group of 300 patients included death in 0.7%, myocardial infarction in 3.7%, bypass grafting in 8% and repeat angioplasty in 13%. Freedom from any adverse clinical event was 80% for all treated patients and 87% for those with previously untreated lesions. CONCLUSIONS: Elective use of this balloon-expandable stent in the native coronary circulation is associated with a low restenosis rate by quantitative angiography in previously untreated lesions and a favorable clinical outcome with an excellent event-free survival rate at 1 year.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/terapia , Stents , Angioplastia Coronaria con Balón , Angiografía Coronaria/métodos , Enfermedad Coronaria/epidemiología , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Recurrencia , Acero Inoxidable , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
10.
Cathet Cardiovasc Diagn ; 32(1): 53-7, 1994 May.
Artículo en Inglés | MEDLINE | ID: mdl-8039221

RESUMEN

Intravascular Doppler assessment of coronary flow velocity has demonstrated the physiologic significance of intermediate stenoses and the success of coronary interventions. We describe a patient where Doppler evaluation confirmed the significance of an intermediate left circumflex ostial stenosis. We also describe the Doppler flow velocity characteristics after successful rotational atherectomy facilitated angioplasty.


Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía Coronaria/métodos , Circulación Coronaria , Enfermedad Coronaria/fisiopatología , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Femenino , Humanos , Ultrasonografía
11.
J Am Coll Cardiol ; 22(6): 1641-6, 1993 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-8227832

RESUMEN

OBJECTIVES: The aim of this study was to assess the immediate and long-term patency of lesion-associated side branches after coronary artery stenting. BACKGROUND: The possible adverse effects related to implantation of coronary stents are not completely known. An important potential complication of stenting is side branch occlusion due to mechanical obstruction or thrombosis. METHODS: Serial coronary angiography was performed in 153 patients (167 lesions) at baseline, after conventional balloon angioplasty, immediately after Palmaz-Schatz stent placement and at 6 months. The patency of side branches, where present, was analyzed at each of these points. RESULTS: Of 167 lesions stented, 57 stent placements spanned 66 side branches with a diameter > or = 1 mm. Twenty-seven (41%) of these side branches had > or = 50% ostial stenosis before standard balloon angioplasty. Six side branches became occluded after standard balloon angioplasty and remained occluded after stenting. Of the 60 side branches patent after conventional angioplasty, 57 (95%) remained patent immediately after stenting. All three side branches that became occluded after stenting had > or = 50% ostial stenosis at baseline. All 60 side branches, including the 3 initially occluded after stenting, were patent at 6-month follow-up. CONCLUSIONS: These findings demonstrate that 1) acute side branch occlusion due to coronary stenting occurs infrequently; 2) when side branch occlusion occurs, it is associated with intrinsic ostial disease; and 3) the patency of side branch ostia is well maintained at long-term follow-up.


Asunto(s)
Circulación Colateral/fisiología , Circulación Coronaria/fisiología , Enfermedad Coronaria/fisiopatología , Enfermedad Coronaria/terapia , Stents , Adulto , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Cineangiografía , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Stents/efectos adversos , Factores de Tiempo
12.
J Am Coll Cardiol ; 22(4): 1033-43, 1993 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-8409038

RESUMEN

OBJECTIVES: The purpose of this study was to compare the assessment of myocardial area at risk in patients with coronary artery stenosis by coronary angiography and quantitative myocardial perfusion imaging with technetium-99m sestamibi. BACKGROUND: Decisions concerning patient management frequently rely on semiquantitative angiographic estimation of the myocardial area at risk, although this approach has not been well validated. Technetium-99m sestamibi is a perfusion imaging agent with little redistribution after initial myocardial uptake. This characteristic allows for injection during angioplasty and later imaging for visualization and quantitation of the nonperfused area at risk. METHODS: Thirty-nine patients referred for coronary angioplasty were studied. Technetium-99m sestamibi was injected intravenously during angioplasty balloon inflation. Planar (33 patients) or tomographic (6 patients) imaging was performed after completion of angioplasty. Imaging was repeated 24 to 48 h later. Myocardial risk area (perfusion defect on angioplasty image) was quantified as an integral using circumferential count distribution profiles and normal reference. Angiographic risk area was assessed using five scoring methods. RESULTS: The scintigraphic risk area was 14 +/- 15 on planar images and 39 +/- 16 on tomography. Scintigraphic risk area of patients with infarction was larger than in patients without (22 +/- 17 versus 7 +/- 8, p = 0.003). The left anterior descending coronary artery had a larger mean risk area than other vessels (22 +/- 15 versus 7 +/- 11, p = 0.002). The presence of angiographic collateral channels was associated with smaller risk areas. Angiographic risk scores correlated only moderately with the technetium-99m sestamibi risk area (r = 0.54 to 0.65), with considerable spread of data. CONCLUSIONS: Area at risk estimated from coronary angiography does not correlate well with that from quantitative myocardial perfusion imaging with technetium-99m sestamibi. These findings emphasize that the functional significance of coronary artery disease is not predicted by coronary anatomy alone.


Asunto(s)
Angioplastia Coronaria con Balón , Angiografía Coronaria , Enfermedad Coronaria/complicaciones , Enfermedad Coronaria/diagnóstico , Infarto del Miocardio/etiología , Índice de Severidad de la Enfermedad , Tecnecio Tc 99m Sestamibi , Adulto , Anciano , Anciano de 80 o más Años , Protocolos Clínicos , Circulación Colateral , Enfermedad Coronaria/clasificación , Enfermedad Coronaria/patología , Enfermedad Coronaria/terapia , Estudios de Evaluación como Asunto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Infarto del Miocardio/patología , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Factores de Riesgo , Tomografía Computarizada de Emisión de Fotón Único
13.
Circulation ; 86(6): 1836-44, 1992 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-1451256

RESUMEN

BACKGROUND: Several metallic intracoronary stents are currently undergoing preliminary evaluation to ascertain potential benefit as means to reduce the 30-40% incidence of restenosis after balloon angioplasty. METHODS AND RESULTS: To determine the incidence and correlates of restenosis after placement of Palmaz-Schatz stents in native coronary arteries in the first group of patients selected for this procedure, clinical and quantitative angiographic data from 206 consecutive patients (221 stenoses) with successful stent placement (diameter stenosis < 50%) were analyzed. Six patients (2.9%) had thrombosis-mediated stent closure within 1 month after stent placement and were excluded from long-term angiographic follow-up. One hundred eighty-one (91%) of the remaining 200 patients had angiography at 5.8 +/- 2.1 months. Patients with and without follow-up did not differ in any baseline characteristic; in particular, history of restenosis at the site stented (73% versus 65%), placement of multiple overlapping stents (17% versus 20%), and mean poststent diameter stenosis (16 +/- 12% versus 14 +/- 12%). The overall incidence of restenosis (diameter stenosis > or = 50% at follow-up) in this group at high risk for restenosis was 36% (95% confidence interval, 29-43%) on a per-stenosis basis. The incidence of restenosis when a single stent was placed was 30% (95% confidence interval, 23-37%). Risk was dependent upon a history of restenosis (present versus absent 36% versus 16%, p = 0.02) and upon whether or not a poststent stenosis < or = 0% was achieved (6% versus 33%, p = 0.02). When multiple overlapping stents were placed, restenosis occurred at 64% of sites, and placement of multiple stents was discouraged during the later phases of this study as these results became apparent. CONCLUSIONS: Although multiple stents appear to yield a poor long-term result, placement of single stents may offer a benefit compared with standard coronary angioplasty, particularly if an excellent angiographic result can be obtained in patients without prior restenosis. Further randomized trials in such patients are needed.


Asunto(s)
Enfermedad Coronaria/terapia , Vasos Coronarios , Stents , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento
14.
Cardiol Clin ; 10(1): 165-83, 1992 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-1739957

RESUMEN

The right ventricle is frequently affected by pulmonary arterial hypertension of postcapillary obstructive origin. The disorders that cause states of pulmonary venous hypertension arise in the left ventricle, left atrium, or pulmonary veins. Biochemical factors, the pericardium, interventricular septum, and pulmonary arterial system combine to communicate the effects of these disorders to the right ventricle. Although not ideally suited to pressure loading, the right ventricle undergoes a series of structural and hemodynamic adaptations that allow for chronic compensation until failure supervenes, with characteristic clinical findings. Exercise may serve to magnify the abnormalities of right ventricular function. Correction of left-sided heart lesions with improvement in pulmonary venous hypertension is associated with favorable effects on the right ventricle. In states of left-sided heart failure, the level of right ventricular function may provide important prognostic information.


Asunto(s)
Cardiopatías/fisiopatología , Hipertensión Pulmonar/fisiopatología , Función Ventricular Derecha/fisiología , Cardiopatías/complicaciones , Insuficiencia Cardíaca/fisiopatología , Hemodinámica/fisiología , Humanos , Hipertensión Pulmonar/etiología , Función Ventricular Izquierda/fisiología
15.
J Am Coll Cardiol ; 18(6): 1445-51, 1991 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-1939944

RESUMEN

The effect of the Palmaz-Schatz stent on the angiographic appearance and residual luminal stenosis in patients with intimal dissection after balloon angioplasty was evaluated in 84 consecutive patients (90 lesions). Coronary angiography was performed before angioplasty, after conventional angioplasty and after stent implantation. The degree of intimal disruption was assessed as follows: grade 0, no dissection; grade 1, simple dissection (intraluminal linear defect or extraluminal cap extravasation); or grade 2, complex dissection (nonlinear spiral defect or luminal defect with multiple irregular borders). Quantitative coronary analysis of digitized cineangiograms was performed with use of a computerized automatic edge detection algorithm. After balloon angioplasty, 31 (34%) of 90 lesions demonstrated intimal dissection (18 simple, 13 complex). After stent implantation, intimal dissection improved by greater than or equal to 1 grade in 29 (94%) of the 31 lesions with 27 (87%) reduced to grade 0 (that is, no dissection). Dissection grade improved after stenting in 16 (89%) of 18 simple dissections and in all 13 complex dissections. Mean diameter stenosis was 77 +/- 17% before angioplasty, 47 +/- 17% after angioplasty and 14 +/- 10% after stenting (before angioplasty vs. after angioplasty and after angioplasty vs. after stenting, p less than 0.0001). In conclusion, intracoronary stenting is effective in reducing the residual luminal stenosis and in improving the angiographic appearance of intimal dissections after conventional balloon angioplasty.


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Vasos Coronarios/lesiones , Stents , Adulto , Anciano , Anciano de 80 o más Años , Cineangiografía , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/terapia , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/terapia , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica
16.
Am J Cardiol ; 67(16): 1339-43, 1991 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-2042565

RESUMEN

Silent myocardial ischemia has been inferred from transient ST-segment depression during continuous electrocardiographic monitoring. Recently, continuous ambulatory monitoring of left ventricular (LV) function using a radionuclide technique (VEST) has demonstrated episodes of significant silent LV dysfunction in the absence of electrocardiographic changes. To validate the demonstration of silent LV dysfunction with this technique, 12 men were studied during percutaneous transluminal coronary angioplasty. A total of 18 left anterior descending coronary artery balloon inflations were performed. Balloon inflations at 8 +/- 2 atm (4 to 10 atm) lasted 70 +/- 16 seconds. Seventeen of 18 inflations were associated with a decrease in LV ejection fraction greater than 0.10. Mean LV ejection fraction decreased from 0.53 +/- 0.08 to 0.28 +/- 0.11 (p less than 0.0001). In contrast, there was pain in only 10 inflations and ST-segment changes in 7. LV dysfunction was associated with a minimal increase in end-diastolic volume (4 +/- 3%, p less than 0.003), and a major increase in relative end-systolic volume (69 +/- 43%, p less than 0.001). These data suggest that continuous monitoring of LV function with the VEST can sensitively detect silent ischemic decreases in LV function occurring during angioplasty, and provide further validation of the use of this technique for detecting silent myocardial ischemia.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad Coronaria/diagnóstico por imagen , Ventriculografía con Radionúclidos/métodos , Función Ventricular Izquierda/fisiología , Anciano , Enfermedad Coronaria/fisiopatología , Enfermedad Coronaria/terapia , Electrocardiografía Ambulatoria , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico/fisiología
17.
Circulation ; 83(1): 148-61, 1991 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-1984878

RESUMEN

Stenting of native coronary arteries with a balloon-expandable stent was attempted in 226 patients after elective angioplasty. Delivery of the device was successful in 213 (94%) of the patients. Of these, 39 received aspirin and dipyridamole only (group 1) and 174 received aspirin, dipyridamole, and warfarin for 1-3 months (group 2). There was no abrupt closure (less than or equal to 1 day) or perioperative death in either group. In-hospital or perioperative complications in group 1 compared with group 2 were as follows: subacute closure (1-14 days), seven (18%) patients versus one (0.6%) patient, respectively, p less than 0.0001; myocardial infarction, five (13%) patients versus one (0.6%) patient, respectively; condition requiring urgent bypass surgery, one (2.5%) patient versus no patients, respectively. Thus, the incidence of major complications such as death, myocardial infarction, or a condition requiring urgent bypass surgery was 15% in group 1 and 0.6% in group 2. Clinical follow-up revealed that 92% of the patients were asymptomatic at 3 months after stenting compared with 6% before stenting (p less than 0.0001). Of the 13 patients who were symptomatic, nine underwent cardiac catheterization and, ultimately, successful elective coronary angioplasty or bypass surgery. We conclude that a high delivery success rate can be expected with this device and that clinical thrombosis is less frequent in anticoagulated patients than in nonanticoagulated patients. Furthermore, in this selected patient population, coronary stenting results in a low incidence of in-hospital and perioperative complications. Clinical success, defined by absence of symptoms, appears to be sustained at 3 months.


Asunto(s)
Enfermedad Coronaria/terapia , Stents , Angioplastia Coronaria con Balón , Aspirina/uso terapéutico , Dipiridamol/uso terapéutico , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Factores de Tiempo , Warfarina/uso terapéutico
19.
Am J Cardiol ; 66(3): 279-84, 1990 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-2195864

RESUMEN

The effects of perfusion of an oxygen-carrying perfluorochemical emulsion (Fluosol) in alleviating symptoms of myocardial ischemia during balloon occlusion were examined in a multicenter trial of 245 patients. Severe anginal pain occurred less frequently in patients receiving Fluosol perfusion (21%) than in those receiving routine angioplasty (34%) (p less than 0.05). ST-segment changes at balloon deflation in routine angioplasty patients were significantly greater than in patients who received oxygenated Fluosol perfusion (2.2 +/- 1.2 vs 1.7 +/- 0.9 mm; p less than 0.03). Profound regional wall dysfunction (-561 +/- 224 U) was observed in routine angioplasty patients by 2-dimensional echocardiography. Patients receiving oxygenated Fluosol perfusion, however, maintained near baseline levels of ventricular function (-61 +/- 335 U) during occlusion (p less than 0.0001). Mean global left ventricular ejection fraction was preserved at baseline levels during balloon inflation in patients perfused with oxygenated Fluosol but decreased significantly (p less than 0.001) during occlusion in routine angioplasty patients. A total of 26 complications (19 routine group; 7 perfusion group) was reported. Adverse responses to the perfusate were infrequent, occurring in 1.6 and 2.0% of patients after the test dose and during perfusion, respectively. Thus, transcatheter perfusion with an oxygen-carrying perfluorochemical emulsion is effective in alleviating myocardial ischemia during angioplasty and can be safely administered in this patient population.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Sustitutos Sanguíneos/uso terapéutico , Circulación Coronaria/efectos de los fármacos , Enfermedad Coronaria/tratamiento farmacológico , Fluorocarburos/uso terapéutico , Anciano , Angina de Pecho/diagnóstico , Angina de Pecho/tratamiento farmacológico , Terapia Combinada , Enfermedad Coronaria/fisiopatología , Enfermedad Coronaria/terapia , Ecocardiografía , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto
20.
Am J Cardiol ; 64(19): 1264-9, 1989 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-2589190

RESUMEN

Earlier studies have indicated that percutaneous transluminal coronary angioplasty (PTCA) of chronic total occlusions has a low success rate. To determine success rate and assess clinical and angiographic variables associated with success and complications, 57 total occlusions in 56 patients undergoing PTCA were analyzed. The clinical duration of occlusion was 51 +/- 86 days. Success (less than 50% residual stenosis) was achieved at 40 of 57 (70%) dilatation sites. Of these 57 total occlusions, 5 were attempted within 24 hours of acute myocardial infarction, 35 between 1 day and 8 weeks of clinical occlusion, 13 greater than 8 weeks and 4 were of unknown duration. Success rates were 4 of 5, 25 of 35, 9 of 13 and 2 of 4, respectively, in each group (difference not significant, comparison of all time groups). Of the 9 narrowings with a successful PTCA for an occlusion greater than 8 weeks, the mean duration of occlusion was 93 +/- 41 days (range 60 to 180). None of the attempted dilatations of occlusions with a clinical duration of greater than 180 days (n = 3) was successful. None of the clinical or angiographic variables (including tortuosity, length of occlusion gap, distance of the occlusion from the vessel origin, thrombus, lesion calcium, collaterals, prior myocardial infarction, vessel dilated or diffuse disease) impacted on success rate (difference not significant for all). No patient died, had a Q-wave infarction, required emergency coronary artery bypass grafting or underwent repeat PTCA within 7 days of the procedure. Non-Q-wave infarction occurred in 2 of 56 patients (4%).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad Coronaria/terapia , Adulto , Anciano , Angiografía , Enfermedad Crónica , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/fisiopatología , Electrocardiografía , Embolia/etiología , Femenino , Predicción , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/fisiopatología , Complicaciones Posoperatorias , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA