Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Animals (Basel) ; 12(17)2022 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-36077882

RESUMEN

The athletic performance and safety of racehorses is influenced by hoof−surface interactions. This intervention study assessed the effect of eight horseshoe−surface combinations on hoof acceleration patterns at impact and foot-off in 13 galloping Thoroughbred racehorses retired from racing. Aluminium, barefoot, GluShu (aluminium−rubber composite) and steel shoeing conditions were trialled on turf and artificial (Martin Collins Activ-Track) surfaces. Shod conditions were applied across all four hooves. Tri-axial accelerometers (SlamStickX, range ±500 g, sampling rate 5000 Hz) were attached to the dorsal hoof wall (x: medio-lateral, medial = positive; y: along dorsal hoof wall, proximal = positive; and z: perpendicular to hoof wall, dorsal = positive). Linear mixed models assessed whether surface, shoeing condition or stride time influenced maximum (most positive) or minimum (most negative) accelerations in x, y and z directions, using ≥40,691 strides (significance at p < 0.05). Day and horse−rider pair were included as random factors, and stride time was included as a covariate. Collective mean accelerations across x, y and z axes were 22−98 g at impact and 17−89 g at foot-off. The mean stride time was 0.48 ± 0.07 s (mean ±2 SD). Impact accelerations were larger on turf in all directions for forelimbs and hindlimbs (p ≤ 0.015), with the exception of the forelimb z-minimum, and in absolute terms, maximum values were typically double the minimum values. The surface type affected all foot-off accelerations (p ≤ 0.022), with the exception of the hindlimb x-maximum; for example, there was an average increase of 17% in z-maximum across limbs on the artificial track. The shoeing condition influenced all impact and foot-off accelerations in the forelimb and hindlimb datasets (p ≤ 0.024), with the exception of the hindlimb impact y-maximum. Barefoot hooves generally experienced the lowest accelerations. The stride time affected all impact and foot-off accelerations (p < 0.001). Identifying factors influencing hoof vibrations upon landing and hoof motion during propulsion bears implication for injury risk and racing outcomes.

2.
3D Print Med ; 8(1): 18, 2022 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-35748984

RESUMEN

BACKGROUND: 3D printing (3DP) has enabled medical professionals to create patient-specific medical devices to assist in surgical planning. Anatomical models can be generated from patient scans using a wide array of software, but there are limited studies on the geometric variance that is introduced during the digital conversion of images to models. The final accuracy of the 3D printed model is a function of manufacturing hardware quality control and the variability introduced during the multiple digital steps that convert patient scans to a printable format. This study provides a brief summary of common algorithms used for segmentation and refinement. Parameters for each that can introduce geometric variability are also identified. Several metrics for measuring variability between models and validating processes are explored and assessed. METHODS: Using a clinical maxillofacial CT scan of a patient with a tumor of the mandible, four segmentation and refinement workflows were processed using four software packages. Differences in segmentation were calculated using several techniques including volumetric, surface, linear, global, and local measurements. RESULTS: Visual inspection of print-ready models showed distinct differences in the thickness of the medial wall of the mandible adjacent to the tumor. Volumetric intersections and heatmaps provided useful local metrics of mismatch or variance between models made by different workflows. They also allowed calculations of aggregate percentage agreement and disagreement which provided a global benchmark metric. For the relevant regions of interest (ROIs), statistically significant differences were found in the volume and surface area comparisons for the final mandible and tumor models, as well as between measurements of the nerve central path. As with all clinical use cases, statistically significant results must be weighed against the clinical significance of any deviations found. CONCLUSIONS: Statistically significant geometric variations from differences in segmentation and refinement algorithms can be introduced into patient-specific models. No single metric was able to capture the true accuracy of the final models. However, a combination of global and local measurements provided an understanding of important geometric variations. The clinical implications of each geometric variation is different for each anatomical location and should be evaluated on a case-by-case basis by clinicians familiar with the process. Understanding the basic segmentation and refinement functions of software is essential for sites to create a baseline from which to evaluate their standard workflows, user training, and inter-user variability when using patient-specific models for clinical interventions or decisions.

3.
Radiographics ; 42(2): 451-468, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35119967

RESUMEN

As the medical applications of three-dimensional (3D) printing increase, so does the number of health care organizations in which adoption or expansion of 3D printing facilities is under consideration. With recent advancements in 3D printing technology, medical practitioners have embraced this powerful tool to help them to deliver high-quality patient care, with a focus on sustainability. The use of 3D printing in the hospital or clinic at the point of care (POC) has profound potential, but its adoption is not without unanticipated challenges and considerations. The authors provide the basic principles and considerations for building the infrastructure to support 3D printing inside the hospital. This process includes building a business case; determining the requirements for facilities, space, and staff; designing a digital workflow; and considering how electronic health records may have a role in the future. The authors also discuss the supported applications and benefits of medical 3D printing and briefly highlight quality and regulatory considerations. The information presented is meant to be a practical guide to assist radiology departments in exploring the possibilities of POC 3D printing and expanding it from a niche application to a fixture of clinical care. An invited commentary by Ballard is available online. ©RSNA, 2022.


Asunto(s)
Sistemas de Atención de Punto , Impresión Tridimensional , Humanos
4.
PLoS One ; 16(11): e0257820, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34813584

RESUMEN

Horseshoes influence how horses' hooves interact with different ground surfaces, during the impact, loading and push-off phases of a stride cycle. Consequently, they impact on the biomechanics of horses' proximal limb segments and upper body. By implication, different shoe and surface combinations could drive changes in the magnitude and stability of movement patterns in horse-jockey dyads. This study aimed to quantify centre of mass (COM) displacements in horse-jockey dyads galloping on turf and artificial tracks in four shoeing conditions: 1) aluminium; 2) barefoot; 3) GluShu; and 4) steel. Thirteen retired racehorses and two jockeys at the British Racing School were recruited for this intervention study. Tri-axial acceleration data were collected close to the COM for the horse (girth) and jockey (kidney-belt), using iPhones (Apple Inc.) equipped with an iOS app (SensorLog, sample rate = 50 Hz). Shoe-surface combinations were tested in a randomized order and horse-jockey pairings remained constant. Tri-axial acceleration data from gallop runs were filtered using bandpass Butterworth filters with cut-off frequencies of 15 Hz and 1 Hz, then integrated for displacement using Matlab. Peak displacement was assessed in both directions (positive 'maxima', negative 'minima') along the cranio-caudal (CC, positive = forwards), medio-lateral (ML, positive = right) and dorso-ventral (DV, positive = up) axes for all strides with frequency ≥2 Hz (mean = 2.06 Hz). Linear mixed-models determined whether surfaces, shoes or shoe-surface interactions (fixed factors) significantly affected the displacement patterns observed, with day, run and horse-jockey pairs included as random factors; significance was set at p<0.05. Data indicated that surface-type significantly affected peak COM displacements in all directions for the horse (p<0.0005) and for all directions (p≤0.008) but forwards in the jockey. The largest differences were observed in the DV-axis, with an additional 5.7 mm and 2.5 mm of downwards displacement for the horse and jockey, respectively, on the artificial surface. Shoeing condition significantly affected all displacement parameters except ML-axis minima for the horse (p≤0.007), and all displacement parameters for the jockey (p<0.0005). Absolute differences were again largest vertically, with notable similarities amongst displacements from barefoot and aluminium trials compared to GluShu and steel. Shoe-surface interactions affected all but CC-axis minima for the jockey (p≤0.002), but only the ML-axis minima and maxima and DV-axis maxima for the horse (p≤0.008). The results support the idea that hoof-surface interface interventions can significantly affect horse and jockey upper-body displacements. Greater sink of hooves on impact, combined with increased push-off during the propulsive phase, could explain the higher vertical displacements on the artificial track. Variations in distal limb mass associated with shoe-type may drive compensatory COM displacements to minimize the energetic cost of movement. The artificial surface and steel shoes provoked the least CC-axis movement of the jockey, so may promote greatest stability. However, differences between horse and jockey mean displacements indicated DV-axis and CC-axis offsets with compensatory increases and decreases, suggesting the dyad might operate within displacement limits to maintain stability. Further work is needed to relate COM displacements to hoof kinematics and to determine whether there is an optimum configuration of COM displacement to optimise performance and minimise injury.


Asunto(s)
Pezuñas y Garras/fisiología , Caballos/fisiología , Locomoción/fisiología , Aceleración , Animales , Fenómenos Biomecánicos , Intervalos de Confianza , Análisis de Datos , Modelos Lineales
5.
Animals (Basel) ; 11(9)2021 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-34573553

RESUMEN

Understanding the effect of horseshoe-surface combinations on hoof kinematics at gallop is relevant for optimising performance and minimising injury in racehorse-jockey dyads. This intervention study assessed hoof breakover duration in Thoroughbred ex-racehorses from the British Racing School galloping on turf and artificial tracks in four shoeing conditions: aluminium, barefoot, aluminium-rubber composite (GluShu) and steel. Shoe-surface combinations were tested in a randomized order and horse-jockey pairings (n = 14) remained constant. High-speed video cameras (Sony DSC-RX100M5) filmed the hoof-ground interactions at 1000 frames per second. The time taken for a hoof marker wand fixed to the lateral hoof wall to rotate through an angle of 90 degrees during 384 breakover events was quantified using Tracker software. Data were collected for leading and non-leading forelimbs and hindlimbs, at gallop speeds ranging from 23-56 km h-1. Linear mixed-models assessed whether speed, surface, shoeing condition and any interaction between these parameters (fixed factors) significantly affected breakover duration. Day and horse-jockey pair were included as random factors and speed was included as a covariate. The significance threshold was set at p < 0.05. For all limbs, breakover times decreased as gallop speed increased (p < 0.0005), although a greater relative reduction in breakover duration for hindlimbs was apparent beyond approximately 45 km h-1. Breakover duration was longer on turf compared to the artificial surface (p ≤ 0.04). In the non-leading hindlimb only, breakover duration was affected by shoeing condition (p = 0.025) and an interaction between shoeing condition and speed (p = 0.023). This work demonstrates that speed, ground surface and shoeing condition are important factors influencing the galloping gait of the Thoroughbred racehorse.

6.
Radiographics ; 41(4): 1208-1229, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34197247

RESUMEN

The adoption of three-dimensional (3D) printing is rapidly spreading across hospitals, and the complexity of 3D-printed models and devices is growing. While exciting, the rapid growth and increasing complexity also put patients at increased risk for potential errors and decreased quality of the final product. More than ever, a strong quality management system (QMS) must be in place to identify potential errors, mitigate those errors, and continually enhance the quality of the product that is delivered to patients. The continuous repetition of the traditional processes of care, without insight into the positive or negative impact, is ultimately detrimental to the delivery of patient care. Repetitive tasks within a process can be measured, refined, and improved and translate into high levels of quality, and the same is true within the 3D printing process. The authors share their own experiences and growing pains in building a QMS into their 3D printing processes. They highlight errors encountered along the way, how they were addressed, and how they have strived to improve consistency, facilitate communication, and replicate successes. They also describe the vital intersection of health care providers, regulatory groups, and traditional manufacturers, who contribute essential elements to a common goal of providing quality and safety to patients. ©RSNA, 2021.


Asunto(s)
Hospitales , Impresión Tridimensional , Comunicación , Humanos
7.
IEEE Trans Biomed Circuits Syst ; 15(2): 281-293, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33729949

RESUMEN

Implantable motor neuroprostheses can restore functionality to individuals with neurological disabilities by electrically activating paralyzed muscles in coordinated patterns. The typical design of neuroprosthetic systems relies on a single multi-use device, but this limits the number of stimulus and sensor channels that can be practically implemented. To address this limitation, a modular neuroprosthesis, the "Networked Neuroprosthesis" (NNP), was developed. The NNP system is the first fully implanted modular neuroprosthesis that includes implantation of all power, signal processing, biopotential signal recording, and stimulating components. This paper describes the design of stimulation and recording modules, bench testing to verify stimulus outputs and appropriate filtering and recording, and validation that the components function properly while implemented in persons with spinal cord injury. The results of system testing demonstrated that the NNP was functional and capable of generating stimulus pulses and recording myoelectric, temperature, and accelerometer signals. Based on the successful design, manufacturing, and testing of the NNP System, multiple clinical applications are anticipated.


Asunto(s)
Terapia por Estimulación Eléctrica , Traumatismos de la Médula Espinal , Redes de Comunicación de Computadores , Humanos , Prótesis e Implantes , Procesamiento de Señales Asistido por Computador , Traumatismos de la Médula Espinal/terapia
8.
J Equine Vet Sci ; 97: 103327, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33478759

RESUMEN

Riding racehorses is a high-risk profession and optimizing safety alongside performance is paramount. Horseshoes play a critical role in providing traction with the ground surface and are therefore a major determinant of safety. However, the subjective perceptions of expert riders influence attitudes towards using different shoes and must be taken into consideration before any changes may be implemented. This study used a questionnaire-based method to evaluate jockey opinion of four shoeing conditions (aluminum, steel, GluShu, and barefoot) trialed at gallop over turf and artificial surfaces. Nine Lickert-style questions explored impact, cushioning, responsiveness, grip, uniformity, smoothness of ride, safety, adaptation period, and overall rating for each shoe-surface combination. A total of 94 questionnaires, based on 15 horse-rider pairs, were assessed using descriptive statistics and linear mixed models performed in SPSS (P < .05). Data indicate that shoe type significantly affected all question responses, with the exception of impact. Surface-type significantly affected perception of grip and safety. Overall, jockeys showed a preference for aluminum and steel shoes across both artificial and turf tracks. These rated "excellent" and were considered to be "very supportive" in approximately 80% of trials, with a 100% "active" response, good grip, and a quick adaptation period. In contrast, barefoot and GluShu conditions were generally considered "moderately supportive," with barefoot appearing favorable on the artificial surface. On turf, barefoot was deemed the least smooth and the only condition that jockeys sometimes marked "unsafe" (17% of responses). Future work aims to investigate the relationship between jockey opinion and hoof kinematic data.


Asunto(s)
Pezuñas y Garras , Animales , Fenómenos Biomecánicos , Caballos , Percepción , Zapatos
9.
Disaster Med Public Health Prep ; 14(2): 273-283, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31397260

RESUMEN

The aim of this systematic review is to evaluate the impact of personal protective equipment (PPE) on medical device use during public health emergency responses. We conducted a systematic literature search of peer-reviewed journals in PubMed, Web of Science, and EBSCO databases. Twenty-nine of 92 articles published between 1984 and 2015 met the inclusion criteria for the review. Although many medical device use impacts were reported, they predominantly fell into 3 categories: airway management, drug administration, and diagnostics and monitoring. Chemical, biological, radiological, and nuclear (CBRN)-PPE increased completion times for emergency clinical procedures by as much as 130% and first attempt failure rates by 35% (anesthetist) versus 55% (non-anesthetist). Effects of CBRN-PPE use depend on device, CBRN-PPE level, and clinician experience and training. Continuous clinical training of responders in CBRN-PPE and device modifications can improve safety and effectiveness of medical device use during public health emergency response.


Asunto(s)
Equipos y Suministros/normas , Equipo de Protección Personal/efectos adversos , Salud Pública/métodos , Humanos , Equipo de Protección Personal/normas , Salud Pública/tendencias
10.
Adv Healthc Mater ; 8(5): e1801471, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30707508

RESUMEN

The skin is responsible for several important physiological functions and has enormous clinical significance in wound healing. Tissue engineered substitutes may be used in patients suffering from skin injuries to support regeneration of the epidermis, dermis, or both. Skin substitutes are also gaining traction in the cosmetics and pharmaceutical industries as alternatives to animal models for product testing. Recent biomedical advances, ranging from cellular-level therapies such as mesenchymal stem cell or growth factor delivery, to large-scale biofabrication techniques including 3D printing, have enabled the implementation of unique strategies and novel biomaterials to recapitulate the biological, architectural, and functional complexity of native skin. This progress report highlights some of the latest approaches to skin regeneration and biofabrication using tissue engineering techniques. Current challenges in fabricating multilayered skin are addressed, and perspectives on efforts and strategies to meet those limitations are provided. Commercially available skin substitute technologies are also examined, and strategies to recapitulate native physiology, the role of regulatory agencies in supporting translation, as well as current clinical needs, are reviewed. By considering each of these perspectives while moving from bench to bedside, tissue engineering may be leveraged to create improved skin substitutes for both in vitro testing and clinical applications.


Asunto(s)
Materiales Biocompatibles/administración & dosificación , Piel/citología , Ingeniería de Tejidos/métodos , Investigación Biomédica Traslacional/métodos , Animales , Humanos , Impresión Tridimensional , Regeneración/fisiología , Piel Artificial , Andamios del Tejido/química , Cicatrización de Heridas/fisiología
11.
Int J Pharm ; 554: 292-301, 2019 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-30439491

RESUMEN

The rheological characteristics of pastes for 3D printing of tablets may not be described fully by the traditional rheological tests generally used for other pastes. In the present study, extrudability testing of carbopol based 3D printing pastes was performed to establish a constitutive rheological model for micro-extrusion. This model was developed for pastes that exhibit a non-linear plasto-viscoelastic behavior and follow the generalized Herschel-Bulkley flow rule. An analytical model was applied to extrudability data obtained by micro-extrusion through nozzles of 0.4 and 0.6 mm diameters. For this purpose, nineteen pastes were prepared per a fractional factorial design using various concentrations of the active ingredient and soluble and insoluble excipients. Critical material parameters (σ0, k and n) of the pastes were then calculated by analyzing extrudability data using a constitutive equation relating flow rate, nozzle and cartridge diameters, printing pressure and slip-flow angle. The accuracy of the constitutive model to predict paste yield stress, consistency and flow indices was evident by low RMSE values of 0.0691 bar, 0.034 and 6.3 bar/sn, respectively. Yield stress, flow and consistency parameters of the pastes were significantly affected by percentages of soluble and swellable excipients. The nozzle diameter had significant effect on flow index (n) but not on the consistency index (k). Hence, this study provides a mechanistic model to characterize the complex rheological behavior of pastes for 3D printing of tablets by a micro-extrusion process.


Asunto(s)
Química Farmacéutica/métodos , Excipientes/química , Impresión Tridimensional , Tecnología Farmacéutica/métodos , Preparaciones de Acción Retardada , Liberación de Fármacos , Modelos Teóricos , Preparaciones Farmacéuticas/administración & dosificación , Preparaciones Farmacéuticas/química , Reología , Solubilidad , Comprimidos
12.
Int J Pharm ; 555: 109-123, 2019 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-30453019

RESUMEN

The future of pharmaceutical manufacturing may be significantly transformed by 3-dimensional (3D) printing. As an emerging technology, the indicators of quality for materials and processes used in 3D printing have not been fully established. The objective of this study was to identify the critical material attributes of semisolid paste formulations filled into cartridges for 3D printing of personalized medicine. Nineteen semisolid formulations were prepared per a fractional factorial design with three replicates of the center point. The variables investigated included percent loading of API and various soluble and insoluble excipients. Pastes were characterized for viscoelastic characteristics during the 3D printing process including creep recovery, cross-modulus and extrudability models. Packing efficiency of pastes into 3D printing cartridges was also evaluated by X-ray tomography. Changes in composition of 3D printing pastes resulted in significant variations in their viscoelastic parameters, namely their elastic deformation, flow and relaxation behaviors. The percent of soluble excipients incorporated was the most significant factor affecting the creep behavior of pastes. Cross-over stresses were assessed to indicate the minimum pressure needed for the pastes to initiate flow. Increasing solid and swellable contents of the pastes from 7% to 63% w/w increased significantly (p < 0.05) the cross-over stress from 0.93 × 10-3 Pa to 9.47 × 10-3 Pa. Increasing soluble ingredients of paste from 30% to 80% w/w was found to increase flow of the paste from 0.41 × 10-3 to 3.85 × 10-3 %/s. X-ray tomography images revealed inclusion of air bubbles during packing of pastes into cartridges. These bubbles may affect the relaxation behavior of the pastes; hence bubbles should be eliminated. This study unveiled the critical material attributes that could be controlled for consistent 3D printing by microextrusion.


Asunto(s)
Excipientes/química , Modelos Teóricos , Impresión Tridimensional , Tecnología Farmacéutica/métodos , Química Farmacéutica/métodos , Preparaciones de Acción Retardada , Liberación de Fármacos , Preparaciones Farmacéuticas/administración & dosificación , Preparaciones Farmacéuticas/química , Solubilidad , Comprimidos
13.
Sci Transl Med ; 10(461)2018 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-30282697

RESUMEN

Additive manufacturing [also known as three-dimensional (3D) printing] is the layer-wise deposition of material to produce a 3D object. This rapidly emerging technology has the potential to produce new medical products with unprecedented structural and functional designs. Here, we describe the U.S. regulatory landscape of additive manufactured (3D-printed) medical devices and biologics and highlight key challenges and considerations.


Asunto(s)
Equipos y Suministros , Impresión Tridimensional/legislación & jurisprudencia , Control Social Formal , Animales , Productos Biológicos/uso terapéutico , Humanos , Medicina Regenerativa
14.
Artículo en Inglés | MEDLINE | ID: mdl-29974058

RESUMEN

Additive manufacturing/3D printing of medical devices is becoming more commonplace, a 3D printed drug is now commercially available, and bioprinting is poised to transition from laboratory to market. Despite the variety of technologies enabling these products, the US Food and Drug Administration (FDA) is charged with protecting and promoting the public health by ensuring these products are safe and effective. To that end, we are presenting the FDA's current perspective on additive manufacturing/3D printing of medical products ranging from those regulated by the Center for Devices and Radiological Health (CDRH), the Center for Drug Evaluation and Research (CDER), and the Center for Biologics Evaluation and Research (CBER). Each Center presents an overview of the additively manufactured products in their area and the specific concerns and thoughts on using this technology in those product spaces.

15.
J Biomed Opt ; 20(12): 121312, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26662064

RESUMEN

The emerging technique of rapid prototyping with three-dimensional (3-D) printers provides a simple yet revolutionary method for fabricating objects with arbitrary geometry. The use of 3-D printing for generating morphologically biomimetic tissue phantoms based on medical images represents a potentially major advance over existing phantom approaches. Toward the goal of image-defined phantoms, we converted a segmented fundus image of the human retina into a matrix format and edited it to achieve a geometry suitable for printing. Phantoms with vessel-simulating channels were then printed using a photoreactive resin providing biologically relevant turbidity, as determined by spectrophotometry. The morphology of printed vessels was validated by x-ray microcomputed tomography. Channels were filled with hemoglobin (Hb) solutions undergoing desaturation, and phantoms were imaged with a near-infrared hyperspectral reflectance imaging system. Additionally, a phantom was printed incorporating two disjoint vascular networks at different depths, each filled with Hb solutions at different saturation levels. Light propagation effects noted during these measurements­including the influence of vessel density and depth on Hb concentration and saturation estimates, and the effect of wavelength on vessel visualization depth­were evaluated. Overall, our findings indicated that 3-D-printed biomimetic phantoms hold significant potential as realistic and practical tools for elucidating light­tissue interactions and characterizing biophotonic system performance.


Asunto(s)
Biomimética , Fantasmas de Imagen , Retina/anatomía & histología , Algoritmos , Bioimpresión , Fondo de Ojo , Hemoglobinas/química , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Óptica y Fotónica , Oximetría , Impresión Tridimensional , Microtomografía por Rayos X , Rayos X
16.
J Biomech ; 48(10): 1828-35, 2015 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-25980556

RESUMEN

Manufacturers and investigators of Total Hip Replacement (THR) bearings require tools to predict the contact mechanics resulting from diverse design and loading parameters. This study provides contact mechanics solutions for metal-on-metal (MoM) bearings that encompass the current design space and could aid pre-clinical design optimization and evaluation. Stochastic finite element (FE) simulation was used to calculate the head-on-cup contact mechanics for five thousand combinations of design and loading parameters. FE results were used to train a Random Forest (RF) surrogate model to rapidly predict the contact patch dimensions, contact area, pressures and plastic deformations for arbitrary designs and loading. In addition to widely observed polar and edge contact, FE results included ring-polar, asymmetric-polar, and transitional categories which have previously received limited attention. Combinations of design and load parameters associated with each contact category were identified. Polar contact pressures were predicted in the range of 0-200 MPa with no permanent deformation. Edge loading (with subluxation) was associated with pressures greater than 500 MPa and induced permanent deformation in 83% of cases. Transitional-edge contact (with little subluxation) was associated with intermediate pressures and permanent deformation in most cases, indicating that, even with ideal anatomical alignment, bearings may face extreme wear challenges. Surrogate models were able to accurately predict contact mechanics 18,000 times faster than FE analyses. The developed surrogate models enable rapid prediction of MoM bearing contact mechanics across the most comprehensive range of loading and designs to date, and may be useful to those performing bearing design optimization or evaluation.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Diseño de Prótesis/métodos , Algoritmos , Simulación por Computador , Elasticidad , Análisis de Elementos Finitos , Humanos , Metales , Modelos Teóricos , Presión , Procesos Estocásticos , Estrés Mecánico
17.
Opt Lett ; 39(10): 3010-3, 2014 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-24978260

RESUMEN

We have investigated the potential of tissue phantoms fabricated with thermosoftening- and photopolymerization-based three-dimensional (3D) printers for use in evaluation of biophotonic imaging systems. The optical properties of printed polymer samples were measured and compared to biological tissues. Phantoms with subsurface channels as small as 0.2 mm in diameter were fabricated and imaged with microscopy, x-ray microtomography, and optical coherence tomography to characterize morphology. These phantoms were then implemented to evaluate the penetration depth of a hyperspectral reflectance imaging system used in conjunction with a near-infrared contrast agent. Results indicated that 3D printing may provide a suitable platform for performance testing in biophotonics, although subsurface imaging is critical to mitigate printer-to-printer variability in matrix homogeneity and feature microstructure.


Asunto(s)
Materiales Biomiméticos/síntesis química , Fantasmas de Imagen , Polímeros/química , Impresión Tridimensional/instrumentación , Tomografía/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo
18.
Soft Matter ; 10(13): 2304-12, 2014 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-24795963

RESUMEN

An aqueous hyaluronic acid (HA(aq)) pericellular coat, when mediating the tactile aspect of cellular contact inhibition, has three tasks: interface formation, mechanical signal transmission and interface separation. To quantify the interfacial adhesive behavior of HA(aq), we induce simultaneous interface formation and separation between HA(aq) and a model hydrophobic, hysteretic Si-SAM surface. While surface tension γ remains essentially constant, interface formation and separation depend greatly on concentration (5 ≤ C ≤ 30 mg mL(-1)), molecular weight (6 ≤ MW ≤ 2000 kDa) and interfacial velocity (0 ≤ V ≤ 3 mm s(-1)), each of which affect shear elastic and loss moduli G' and G'', respectively. Viscoelasticity dictates the mode of interfacial motion: wetting-dewetting, capillary necking, or rolling. Wetting-dewetting is quantified using advancing and receding contact angles θ(A) and θ(R), and the hysteresis between them, yielding data landscapes for each C above the [MW, V] plane. The landscape sizes, shapes, and curvatures disclose the interplay, between surface tension and viscoelasticity, which governs interfacial dynamics. Gel point coordinates modulus G and angular frequency ω appear to predict wetting-dewetting (G < 75 ω0.2), capillary necking (75 ω0.2 < G < 200 ω0.075) or rolling (G > 200ω0.075). Dominantly dissipative HA(aq) sticks to itself and distorts irreversibly before separating, while dominantly elastic HA(aq) makes contact and separates with only minor, reversible distortion. We propose the dimensionless number (G'V)/(ω(r)γ), varying from 10(-5) to 10(3) in this work, as a tool to predict the mode of interface formation-separation by relating interfacial kinetics with bulk viscoelasticity. Cellular contact inhibition may be thus aided or compromised by physiological or interventional shifts in [C, MW, V], and thus in (G'V)/(ω(r)γ), which affect both mechanotransduction and interfacial dynamics. These observations, understood in terms of physical properties, may be broadened to probe interfacial dynamics of other viscoelastic aqueous biopolymers.


Asunto(s)
Ácido Hialurónico/química , Módulo de Elasticidad , Elasticidad , Interacciones Hidrofóbicas e Hidrofílicas , Peso Molecular , Viscosidad , Agua/química
19.
Contraception ; 90(1): 86-93, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24680185

RESUMEN

BACKGROUND: Male condoms act as mechanical barriers to prevent passage of body fluids. For effective use of condoms the mechanical seal is also expected to remain intact under reasonable use conditions, including with personal lubricants. Absorption of low molecular weight lubricant components into the material of male condoms may initiate material changes leading to swelling and stress relaxation of the polymer network chains that could affect performance of the sealing function of the device. Swelling indicates both a rubber-solvent interaction and stress relaxation, the latter of which may indicate and/or result in a reduced seal pressure in the current context. METHODS: Swelling and stress relaxation of natural rubber latex condoms were assessed in a laboratory model in the presence of silicone-, glycol-, and water-based lubricants. RESULTS: Within 15 minutes, significant swelling (≥6 %) and stress reduction (≥12 %) of condoms were observed with 2 out of 4 silicone-based lubricants tested, but neither was observed with glycol- or water-based lubricants tested. Under a given strain, reduction in stress was prominent during the swelling processes, but not after the process was complete. CONCLUSIONS: Lubricant induced swelling and stress relaxation may loosen the circumferential stress responsible for the mechanical seal. Swelling and stress relaxation behavior of latex condoms in the presence of personal lubricants may be useful tests to identify lubricant-rooted changes in condom-materials. IMPLICATION: For non-lubricated latex condoms, material characteristics--which are relevant to failure--may change in the presence of a few silicone-based personal lubricants. These changes may in turn induce a loss of condom seal during use, specifically at low strain conditions.


Asunto(s)
Condones , Lubricantes/química , Goma/química , Módulo de Elasticidad , Glicoles/química , Humanos , Masculino , Siliconas/química , Agua/química
20.
J Biomech ; 47(7): 1634-41, 2014 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-24657104

RESUMEN

A variety of design and patient parameters have been implicated in recent reports of fretting corrosion at modular connections in total hip arthroplasty. We sought to identify the relative sensitivity of mechanical fretting to a comprehensive set of parameters such that attention may be focused on key variables. Stochastic finite element simulation of the head-neck taper-trunnion junction was performed. Four-hundred parameter sets were simulated using realistic variations of design variables, material properties and loading parameters to predict contact pressures (P), micromotions (M) and fretting work (coefficient of friction×P×M) over cycles of gait. Results indicated that fretting work was correlated with only three parameters: angular mismatch, center offset and body weight (r=0.47, 0.53 and 0.43, p<0.001). Maximum contact pressure increased by 85MPa for every 0.1° of angular mismatch. Maximum micromotion increased by 5µm per 10mm additional head offset and 1µm per 10kg increased body weight. Uncorrelated parameters included trunnion diameter, trunnion length and impaction forces. It was concluded that appropriate limiting of angular mismatch and center offset could minimize fretting, and hence its contribution to corrosion, at modular connections.


Asunto(s)
Cabeza Femoral/fisiología , Cuello Femoral/fisiología , Prótesis de Cadera , Modelos Biológicos , Diseño de Prótesis , Artroplastia de Reemplazo de Cadera , Fenómenos Biomecánicos , Simulación por Computador , Análisis de Elementos Finitos , Marcha/fisiología , Humanos , Presión
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA