Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 223
Filtrar
1.
Eur Heart J ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748258

RESUMEN

BACKGROUND AND AIMS: Patients with repaired tetralogy of Fallot remain at risk of life-threatening ventricular tachycardia related to slow-conducting anatomical isthmuses (SCAIs). Preventive ablation of SCAI identified by invasive electroanatomical mapping is increasingly performed. This study aimed to non-invasively identify SCAI using 3D late gadolinium enhancement cardiac magnetic resonance (3D-LGE-CMR). METHODS: Consecutive tetralogy of Fallot patients who underwent right ventricular electroanatomical mapping (RV-EAM) and 3D-LGE-CMR were included. High signal intensity threshold for abnormal myocardium was determined based on direct comparison of bipolar voltages and signal intensity by co-registration of RV-EAM with 3D-LGE-CMR. The diagnostic performance of 3D-LGE-CMR to non-invasively identify SCAI was determined, validated in a second cohort, and compared with the discriminative ability of proposed risk scores. RESULTS: The derivation cohort consisted of 48 (34 ± 16 years) and the validation cohort of 53 patients (36 ± 18 years). In the derivation cohort, 78 of 107 anatomical isthmuses (AIs) identified by EAM were normal-conducting AI, 22 were SCAI, and 7 blocked AI. High signal intensity threshold was 42% of the maximal signal intensity. The sensitivity and specificity of 3D-LGE-CMR for identifying SCAI or blocked AI were 100% and 90%, respectively. In the validation cohort, 85 of 124 AIs were normal-conducting AI, 36 were SCAI, and 3 blocked AI. The sensitivity and specificity of 3D-LGE-CMR were 95% and 91%, respectively. All risk scores showed an at best modest performance to identify SCAI (area under the curve ≤ .68). CONCLUSIONS: 3D late gadolinium enhancement cardiac magnetic resonance can identify SCAI with excellent accuracy and may refine non-invasive risk stratification and patient selection for invasive EAM in tetralogy of Fallot.

3.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38646926

RESUMEN

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Resultado del Tratamiento , Venas Pulmonares/cirugía , Femenino , Masculino , Recurrencia , Europa (Continente) , Persona de Mediana Edad
4.
Magn Reson Imaging ; 109: 256-263, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38522623

RESUMEN

PURPOSE: Joint bright- and black-blood MRI techniques provide improved scar localization and contrast. Black-blood contrast is obtained after the visual selection of an optimal inversion time (TI) which often results in uncertainties, inter- and intra-observer variability and increased workload. In this work, we propose an artificial intelligence-based algorithm to enable fully automated TI selection and simplify myocardial scar imaging. METHODS: The proposed algorithm first localizes the left ventricle using a U-Net architecture. The localized left cavity centroid is extracted and a squared region of interest ("focus box") is created around the resulting pixel. The focus box is then propagated on each image and the sum of the pixel intensity inside is computed. The smallest sum corresponds to the image with the lowest intensity signal within the blood pool and healthy myocardium, which will provide an ideal scar-to-blood contrast. The image's corresponding TI is considered optimal. The U-Net was trained to segment the epicardium in 177 patients with binary cross-entropy loss. The algorithm was validated retrospectively in 152 patients, and the agreement between the algorithm and two magnetic resonance (MR) operators' prediction of TI values was calculated using the Fleiss' kappa coefficient. Thirty focus box sizes, ranging from 2.3mm2 to 20.3cm2, were tested. Processing times were measured. RESULTS: The U-Net's Dice score was 93.0 ± 0.1%. The proposed algorithm extracted TI values in 2.7 ± 0.1 s per patient (vs. 16.0 ± 8.5 s for the operator). An agreement between the algorithm's prediction and the MR operators' prediction was found in 137/152 patients (κ= 0.89), for an optimal focus box of size 2.3cm2. CONCLUSION: The proposed fully-automated algorithm has potential of reducing uncertainties, variability, and workload inherent to manual approaches with promise for future clinical implementation for joint bright- and black-blood MRI.


Asunto(s)
Medios de Contraste , Gadolinio , Humanos , Estudios Retrospectivos , Cicatriz/diagnóstico por imagen , Inteligencia Artificial , Miocardio/patología , Imagen por Resonancia Magnética/métodos
5.
Sci Rep ; 14(1): 5860, 2024 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-38467726

RESUMEN

Atrial fibrillation (AF) is the most common human arrhythmia, forming thrombi mostly in the left atrial appendage (LAA). However, the relation between LAA morphology, blood patterns and clot formation is not yet fully understood. Furthermore, the impact of anatomical structures like the pulmonary veins (PVs) have not been thoroughly studied due to data acquisition difficulties. In-silico studies with flow simulations provide a detailed analysis of blood flow patterns under different boundary conditions, but a limited number of cases have been reported in the literature. To address these gaps, we investigated the influence of PVs on LA blood flow patterns and thrombus formation risk through computational fluid dynamics simulations conducted on a sizeable cohort of 130 patients, establishing the largest cohort of patient-specific LA fluid simulations reported to date. The investigation encompassed an in-depth analysis of several parameters, including pulmonary vein orientation (e.g., angles) and configuration (e.g., number), LAA and LA volumes as well as their ratio, flow, and mass-less particles. Our findings highlight the total number of particles within the LAA as a key parameter for distinguishing between the thrombus and non-thrombus groups. Moreover, the angles between the different PVs play an important role to determine the flow going inside the LAA and consequently the risk of thrombus formation. The alignment between the LAA and the main direction of the left superior pulmonary vein, or the position of the right pulmonary vein when it exhibits greater inclination, had an impact to distinguish the control group vs. the thrombus group. These insights shed light on the intricate relationship between PV configuration, LAA morphology, and thrombus formation, underscoring the importance of comprehensive blood flow pattern analyses.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Venas Pulmonares , Trombosis , Humanos , Apéndice Atrial/diagnóstico por imagen , Venas Pulmonares/diagnóstico por imagen , Ecocardiografía Transesofágica , Atrios Cardíacos/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen
6.
Artículo en Inglés | MEDLINE | ID: mdl-38509335

RESUMEN

INTRODUCTION: Bicuspid aortic valves (BAV) are the most common congenital heart defects and the extent of ventricular arrhythmias (VA) in patients with BAV is unclear. The objective of this study is to describe VAs and late gadolinium enhancement cardiac magnetic resonance imaging (LGE-CMR) in patients with BAV. METHODS: A total of 19 patients with BAV (18 males, age: 58 ± 13 years) were referred for VA ablation procedures. Ten patients had BAVs at the time of ablation, nine patients had prior aortic valve replacement for a BAV. All but one patient had LGE-CMR and all patients underwent programmed ventricular stimulation at the time of the ablation. RESULTS: Frequent PVCs were the targeted VAs in 17/19 patients and VT in 2/19 patients. Monomorphic ventricular tachycardia (VT) was inducible in 6 patients. A total of 15 VTs were inducible (2.5 ± 1.0 VTs per patient with a mean cycle length of 322 ± 83 msec). LGE was present in 13 patients. Patients with inducible VT had larger borderzone and core scar compared to non-inducible patients (7.8 ± 2.1 cm3 vs. 2.5 ± 3.1 cm3 and 5.1 ± 2.6 cm3 vs. 1.9 ± 3.0 cm3, p-value < .05 for both). PVCs and VTs were mapped to the periaortic valve area in 12 patients and 4 patients, respectively. The PVC burden was reduced from 27 ± 13 to 3 ± 6 (p < .001) and the ejection fraction improved from 49 ± 13% to 55 ± 9% (p = .005). CONCLUSIONS: VAs in patients with BAV often originate from the perivalvular area and patients often have LGE and inducible VT. LGE may be due to ventricular remodeling secondary to the presence of BAV and harbors the arrhythmogenic substrate for VT.

7.
Heart Rhythm ; 21(1): 36-44, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37852565

RESUMEN

BACKGROUND: Patients with arrhythmias originating from papillary muscles (PAPs) often have pleomorphic ventricular arrhythmias (PVAs) that can result in failed ablations. The mechanism of PVAs is unknown. OBJECTIVE: The purpose of this study was to assess the prevalence and mechanisms of PVAs and the impact on outcomes in patients with focal left ventricular PAP ventricular arrhythmias (VAs). METHODS: The sites of origin (SOOs) of VAs in 43 consecutive patients referred for ablation of focal left ventricular PAP VAs were determined by activation and pacemapping. SOOs were classified as (1) unifocal generating a single VA morphology; (2) unifocal from a deeper-seated origin generating multiple VA morphologies; (3) unifocal located on a PAP branching site; (4) multifocal from a single or multiple PAPs generating multiple VA morphologies; and (5) multifocal from a PAP and a different anatomic source. RESULTS: Most patients had multiple morphologies (n = 34 [79%]) and multiple mechanisms (79%) generating the different VA morphologies. Most of the patients with PVAs had multiple SOOs from a single or different PAPs (n = 23 [68%]), followed by patients with SOOs from PAP and non-PAP sites (n = 19 [56%]). In 13 patients (38%), single SOOs accounted for the observed PVAs. The frequent observation (n = 20) of changing QRS morphologies after radiofrequency energy delivery targeting a single VA suggests the presence of a deeper focus with changing sites of preferential conduction. CONCLUSION: VA pleomorphism in patients with PAP arrhythmias is most often due to premature ventricular complexes originating from different SOOs. The second most common cause is preferential conduction from a single SOO via PAP branching sites.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Humanos , Músculos Papilares , Taquicardia Ventricular/cirugía , Ventrículos Cardíacos , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía , Frecuencia Cardíaca , Electrocardiografía , Resultado del Tratamiento
8.
Eur Heart J Cardiovasc Imaging ; 25(4): 548-557, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37987558

RESUMEN

AIMS: To identify clinical correlates of myocardial T1ρ and to examine how myocardial T1ρ values change under various clinical scenarios. METHODS AND RESULTS: A total of 66 patients (26% female, median age 57 years [Q1-Q3, 44-65 years]) with known structural heart disease and 44 controls (50% female, median age 47 years [28-57 years]) underwent cardiac magnetic resonance imaging at 1.5 T, including T1ρ mapping, T2 mapping, native T1 mapping, late gadolinium enhancement, and extracellular volume (ECV) imaging. In controls, T1ρ positively related with T2 (P = 0.038) and increased from basal to apical levels (P < 0.001). As compared with controls and remote myocardium, T1ρ significantly increased in all patients' sub-groups and all types of myocardial injuries: acute and chronic injuries, focal and diffuse tissue abnormalities, as well as ischaemic and non-ischaemic aetiologies (P < 0.05). T1ρ was independently associated with T2 in patients with acute injuries (P = 0.004) and with native T1 and ECV in patients with chronic injuries (P < 0.05). Myocardial T1ρ mapping demonstrated good intra- and inter-observer reproducibility (intraclass correlation coefficient = 0.86 and 0.83, respectively). CONCLUSION: Myocardial T1ρ mapping appears to be reproducible and equally sensitive to acute and chronic myocardial injuries, whether of ischaemic or non-ischaemic origins. It may thus be a contrast-agent-free biomarker for gaining new and quantitative insight into myocardial structural disorders. These findings highlight the need for further studies through prospective and randomized trials.


Asunto(s)
Cardiomiopatías , Lesiones Cardíacas , Humanos , Femenino , Persona de Mediana Edad , Masculino , Medios de Contraste , Reproducibilidad de los Resultados , Estudios Prospectivos , Imagen por Resonancia Cinemagnética/métodos , Gadolinio , Miocardio/patología , Cardiomiopatías/patología , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética/efectos adversos , Valor Predictivo de las Pruebas
10.
JACC Clin Electrophysiol ; 9(12): 2507-2519, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37804259

RESUMEN

BACKGROUND: Electrophysiological mapping of ventricular tachycardia (VT) is tedious and poorly reproducible. Substrate analysis on imaging cannot explicitly display VT circuits. OBJECTIVES: This study sought to introduce a computed tomography-based model personalization approach, allowing for the simulation of postinfarction VT in a clinically compatible time frame. METHODS: In 10 patients (age 65 ± 11 years, 9 male) referred for post-VT ablation, computed tomography-derived wall thickness maps were registered to 25 electroanatomical maps (sinus rhythm, paced, and VT). The relationship between wall thickness and electrophysiological characteristics (activation-recovery interval) was analyzed. Wall thickness was then employed to parameterize a fast and tractable organ-scale wave propagation model. Pacing protocols were simulated from multiple sites to test VT induction in silico. In silico VTs were compared to VT circuits mapped clinically. RESULTS: Clinically, 6 different VTs could be induced with detailed maps in 9 patients. The proposed model allowed for fast simulation (median: 6 min/pacing site). Simulations of steady pacing (600 milliseconds) from 100 different sites/patient never triggered any arrhythmia. Applying S1-S2 or S1-S2-S3 induction schemes allowed for the induction of in silico VTs in the 9 of 10 patients who were clinically inducible. The patient who was not inducible clinically was also noninducible in silico. A total of 42 different VTs were simulated (4.2 ± 2 per patient). Six in silico VTs matched a VT circuit mapped clinically. CONCLUSIONS: The proposed framework allows for personalized simulations in a matter of hours. In 6 of 9 patients, simulations show re-entrant patterns matching intracardiac recordings.


Asunto(s)
Taquicardia Ventricular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Tomografía Computarizada por Rayos X
11.
Radiology ; 308(3): e230462, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37668517

RESUMEN

Background At follow-up CT after left atrial appendage occlusion (LAAO), hypoattenuation thickening (HAT) on the atrial aspect of the device is a common finding but the clinical implications require further study. Purpose To assess the association of HAT grade at follow-up CT with clinical characteristics and outcomes in patients who underwent LAAO. Materials and Methods This prospective study included consecutive participants with atrial fibrillation and who were at high risk for stroke (CHA2DS2-VASc score ≥4) who underwent LAAO and were administered pacifier or nonpacifier devices at two French medical centers between January 2012 and November 2020. Postprocedure CT images were evaluated by two radiologists in consensus and device-specific interpretation algorithms were applied to classify HAT as low grade (low suspicion of thrombosis) or high grade (high suspicion of thrombosis). The association between HAT grade and clinical characteristics was assessed using multinomial logistic regression, and variables associated with risk of stroke were assessed using a Cox proportional hazard model. Results This study included 412 participants (mean age, 76 years ± 8 [SD]; 284 male participants) who underwent follow-up CT at a mean of 4.2 months ± 1.7 after LAAO. Low-grade and high-grade HAT were depicted in 98 of 412 (23.8%) and 21 of 412 (5.1%) participants, respectively. High-grade HAT was associated with higher odds of antithrombotic drug discontinuation during follow-up (odds ratio, 9.5; 95% CI: 3.1, 29.1; P < .001), whereas low-grade HAT was associated with lower odds of persisting left atrial appendage patency (odds ratio, 0.46; 95% CI: 0.27, 0.79; P = .005). During a median follow-up of 17 months (IQR, 11-41 months), stroke occurred in 24 of 412 (5.8%) participants. High-grade HAT was associated with stroke (hazard ratio, 4.6; 95% CI: 1.5, 14.0; P = .008) and low-grade HAT (P = .62) was not. Conclusion Low-grade HAT was a more common finding at CT performed after LAAO CT (24%) than was high-grade HAT (5%), but it was associated with more favorable outcomes than high-grade HAT, which was associated with higher stroke risk. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Choe in this issue.


Asunto(s)
Apéndice Atrial , Accidente Cerebrovascular , Humanos , Masculino , Anciano , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Estudios Prospectivos , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Atrios Cardíacos , Tomografía Computarizada por Rayos X
12.
J Cardiovasc Electrophysiol ; 34(9): 1835-1842, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37579221

RESUMEN

INTRODUCTION: Variants of cardiomyopathy genes in patients with nonischemic cardiomyopathy (NICM) generate various phenotypes of cardiac scar and delayed enhancement cardiac magnetic resonance (DE-CMR) imaging which may impact ventricular tachycardia (VT) management. METHODS: The objective was to compare the findings of cardiomyopathy genetic testing on DE-CMR imaging and long-term outcomes among patients with NICM undergoing VT ablation procedures. Image phenotyping and genotyping were performed in a consecutive series of patients referred for VT ablation and correlated to survival free of VT. Scar depth index (SDI) (% of scar at 0-3 mm, 3-5 mm and >5 mm projected on the closest endocardial surface) was determined. RESULTS: Forty-three patients were included (11 women, 55 ± 14 years, ejection fraction (EF) 45 ± 16%) and were followed for 3.4 ± 2.9 years. Pathogenic variants (PV) were identified in 16 patients (37%) in the following genes: LMNA (n = 5), TTN (n = 5), DSP (n = 2), AMLS1 (n = 1), MYBPC3 (n = 1), PLN (n = 1), and SCN5A (n = 1). A ring-like septal scar (RLSS) pattern was more often seen in patients with pathogenic variants (66% vs 15%, p = .001). RLSS was associated with deeper seated scars (SDI >5 mm 30.6 ± 22.6% vs 12.4 ± 16.2%, p = .005), and increased VT recurrence (HR 5.7 95% CI[1.8-18.4], p = .003). After adjustment for age, sex, EF, and total scar burden, the presence of a PV remained independently associated with worse outcomes (HR 4.7 95% CI[1.22-18.0], p = .02). CONCLUSIONS: Preprocedural genotyping and scar phenotyping is beneficial to identify patients with a favorable procedural outcome. Some PVs are associated with an intramural, deeper seated scar phenotype and have an increase of VT recurrence after ablation.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Taquicardia Ventricular , Humanos , Femenino , Cicatriz/diagnóstico , Cicatriz/genética , Cicatriz/patología , Genotipo , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/genética , Cardiomiopatías/patología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/genética , Taquicardia Ventricular/cirugía , Ventrículos Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
13.
JACC Clin Electrophysiol ; 9(10): 2041-2051, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37480873

RESUMEN

BACKGROUND: Slow-conductive structural abnormalities located in the epicardium of the right ventricle (RV) underlie Brugada syndrome (BrS). The extent of such substrate in the left ventricle (LV) has not been investigated. OBJECTIVES: This study sought to characterize the extent of epicardial substrate abnormalities in BrS. METHODS: We evaluated 22 consecutive patients (mean age 46 ± 11 years, 21 male) referred for recurrent ventricular arrhythmias (mean 10 ± 13 episodes) in the setting of BrS. The patients underwent clinical investigations and wide genetic screening to identify SCN5A mutations and common risk variants. High-density biventricular epicardial mapping was performed to detect prolonged (>70 ms) fragmented electrograms, indicating abnormal substrate area. RESULTS: All patients presented with abnormal substrate in the epicardial anterior RV (27 ± 11 cm2). Abnormal substrate was also identified on the LV epicardium in 10 patients (45%), 9 at baseline and 1 after ajmaline infusion, covering 15 ± 11 cm2. Of these, 4 had severe LV fascicular blocks. Patients with LV substrate had a longer history of arrhythmia (11.4 ± 6.7 years vs 4.3 ± 4.3 years; P = 0.003), longer PR (217 ± 24 ms vs 171 ± 14 ms; P < 0.001) and HV (60 ± 12 ms vs 46 ± 5 ms; P = 0.005) intervals, and abnormal substrate also extending into the inferior RV (100% vs 33%; P = 0.001). SCN5A mutation was present in 70% of patients with LV substrate (vs 25%; P = 0.035). SCN5A BrS patients with recurrent ventricular arrhythmias present a higher polygenic risk score compared with a nonselected BrS population (median of differences: -0.86; 95% CI: -1.48 to -0.27; P = 0.02). CONCLUSIONS: A subset of patients with BrS present an abnormal substrate extending onto the LV epicardium and inferior RV that is associated with SCN5A mutations and multigenic variants.


Asunto(s)
Síndrome de Brugada , Ventrículos Cardíacos , Humanos , Masculino , Adulto , Persona de Mediana Edad , Ventrículos Cardíacos/diagnóstico por imagen , Síndrome de Brugada/diagnóstico , Electrocardiografía , Mapeo Epicárdico , Arritmias Cardíacas
14.
J Cardiovasc Electrophysiol ; 34(8): 1708-1717, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37431258

RESUMEN

BACKGROUND: The impact of filtering on bipolar electrograms (EGMs) has not been systematically examined. We tried to clarify the optimal filter configuration for ventricular tachycardia (VT) ablation. METHODS: Fifteen patients with VT were included. Eight different filter configurations were prospectively created for the distal bipoles of the ablation catheter: 1.0-250, 10-250, 100-250, 30-50, 30-100, 30-250, 30-500, and 30-1000 Hz. Pre-ablation stable EGMs with good contact (contact force > 10 g) were analyzed. Baseline fluctuation, baseline noise, bipolar peak-to-peak voltage, and presence of local abnormal ventricular activity (LAVA) were compared between different filter configurations. RESULTS: In total, 2276 EGMs with multiple bipolar configurations in 246 sites in scar and border areas were analyzed. Baseline fluctuation was only observed in the high-pass filter of (HPF) ≤ 10 Hz (p < .001). Noise level was lowest at 30-50 Hz (0.018 [0.012-0.029] mV), increased as the low-pass filter (LPF) extended, and was highest at 30-1000 Hz (0.047 [0.041-0.061] mV) (p < .001). Conversely, the HPF did not affect the noise level at ≤30 Hz. As the HPF extended to 100 Hz, bipolar voltages significantly decreased (p < .001), but were not affected when the LPF was extended to ≥100 Hz. LAVAs were most frequently detected at 30-250 Hz (207/246; 84.2%) and 30-500 Hz (208/246; 84.6%), followed by 30-1000 Hz (205/246; 83.3%), but frequently missed at LPF ≤ 100 Hz or HPF ≤ 10 Hz (p < .001). A 50-Hz notch-filter reduced the bipolar voltage by 43.9% and LAVA-detection by 34.5% (p < .0001). CONCLUSION: Bipolar EGMs are strongly affected by filter settings in scar/border areas. In all, 30-250 or 30-500 Hz may be the best configuration, minimizing the baseline fluctuation, baseline noise, and detecting LAVAs. Not applying the 50-Hz notch filter may be beneficial to avoid missing VT substrate.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Cicatriz , Ablación por Catéter/efectos adversos
15.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37428890

RESUMEN

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Humanos , Estudios Retrospectivos , Técnicas Electrofisiológicas Cardíacas , Taquicardia , Atrios Cardíacos , Resultado del Tratamiento
16.
MAGMA ; 36(6): 877-885, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37294423

RESUMEN

OBJECTIVE: To simplify black-blood late gadolinium enhancement (BL-LGE) cardiac imaging in clinical practice using an image-based algorithm for automated inversion time (TI) selection. MATERIALS AND METHODS: The algorithm selects from BL-LGE TI scout images, the TI corresponding to the image with the highest number of sub-threshold pixels within a region of interest (ROI) encompassing the blood-pool and myocardium. The threshold value corresponds to the most recurrent pixel intensity of all scout images within the ROI. ROI dimensions were optimized in 40 patients' scans. The algorithm was validated retrospectively (80 patients) versus two experts and tested prospectively (5 patients) on a 1.5 T clinical scanner. RESULTS: Automated TI selection took ~ 40 ms per dataset (manual: ~ 17 s). Fleiss' kappa coefficient for automated-manual, intra-observer and inter-observer agreements were [Formula: see text]= 0.73, [Formula: see text] = 0.70 and [Formula: see text] = 0.63, respectively. The agreement between the algorithm and any expert was better than the agreement between the two experts or between two selections of one expert. DISCUSSION: Thanks to its good performance and simplicity of implementation, the proposed algorithm is a good candidate for automated BL-LGE imaging in clinical practice.


Asunto(s)
Medios de Contraste , Gadolinio , Humanos , Estudios Retrospectivos , Corazón/diagnóstico por imagen , Miocardio , Imagen por Resonancia Magnética/métodos
17.
Front Physiol ; 14: 1198002, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37275229

RESUMEN

Introduction: Premature ventricular contractions (PVCs) are one of the most commonly targeted pathologies for ECGI validation, often through ventricular stimulation to mimic the ectopic beat. However, it remains unclear if such stimulated beats faithfully reproduce spontaneously occurring PVCs, particularly in the case of the R-on-T phenomenon. The objective of this study was to determine the differences in ECGI accuracy when reconstructing spontaneous PVCs as compared to ventricular-stimulated beats and to explore the impact of pathophysiological perturbation on this reconstruction accuracy. Methods: Langendorff-perfused pig hearts (n = 3) were suspended in a human torso-shaped tank, and local hyperkalemia was induced through perfusion of a high-K+ solution (8 mM) into the LAD. Recordings were taken simultaneously from the heart and tank surfaces during ventricular pacing and during spontaneous PVCs (including R-on-T), both at baseline and high K+. Epicardial potentials were reconstructed from torso potentials using ECGI. Results: Spontaneously occurring PVCs were better reconstructed than stimulated beats at baseline in terms of electrogram morphology [correlation coefficient (CC) = 0.74 ± 0.05 vs. CC = 0.60 ± 0.10], potential maps (CC = 0.61 ± 0.06 vs. CC = 0.51 ± 0.12), and activation time maps (CC = 0.86 ± 0.07 vs. 0.76 ± 0.10), though there was no difference in the localization error (LE) of epicardial origin (LE = 14 ± 6 vs. 15 ± 11 mm). High K+ perfusion reduced the accuracy of ECGI reconstructions in terms of electrogram morphology (CC = 0.68 ± 0.10) and AT maps (CC = 0.70 ± 0.12 and 0.59 ± 0.23) for isolated PVCs and paced beats, respectively. LE trended worse, but the change was not significant (LE = 17 ± 9 and 20 ± 12 mm). Spontaneous PVCs were less well when the R-on-T phenomenon occurred and the activation wavefronts encountered a line of block. Conclusion: This study demonstrates the differences in ECGI accuracy between spontaneous PVCs and ventricular-paced beats. We also observed a reduction in this accuracy near regions of electrically inactive tissue. These results highlight the need for more physiologically realistic experimental models when evaluating the accuracy of ECGI methods. In particular, reconstruction accuracy needs to be further evaluated in the presence of R-on-T or isolated PVCs, particularly when encountering obstacles (functional or anatomical) which cause line of block and re-entry.

18.
J Cardiovasc Magn Reson ; 25(1): 34, 2023 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-37331930

RESUMEN

The potential of cardiac magnetic resonance to improve cardiovascular care and patient management is considerable. Myocardial T1-rho (T1ρ) mapping, in particular, has emerged as a promising biomarker for quantifying myocardial injuries without exogenous contrast agents. Its potential as a contrast-agent-free ("needle-free") and cost-effective diagnostic marker promises high impact both in terms of clinical outcomes and patient comfort. However, myocardial T1ρ mapping is still at a nascent stage of development and the evidence supporting its diagnostic performance and clinical effectiveness is scant, though likely to change with technological improvements. The present review aims at providing a primer on the essentials of myocardial T1ρ mapping, and to describe the current range of clinical applications of the technique to detect and quantify myocardial injuries. We also delineate the important limitations and challenges for clinical deployment, including the urgent need for standardization, the evaluation of bias, and the critical importance of clinical testing. We conclude by outlining technical developments to be expected in the future. If needle-free myocardial T1ρ mapping is shown to improve patient diagnosis and prognosis, and can be effectively integrated in cardiovascular practice, it will fulfill its potential as an essential component of a cardiac magnetic resonance examination.


Asunto(s)
Infarto del Miocardio , Humanos , Infarto del Miocardio/patología , Valor Predictivo de las Pruebas , Miocardio/patología , Imagen por Resonancia Magnética/métodos , Medios de Contraste , Espectroscopía de Resonancia Magnética
19.
Heart Rhythm ; 20(10): 1445-1454, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37329938

RESUMEN

BACKGROUND: Ventricular arrhythmias (VAs) originating from papillary muscles (PAPs) can be challenging when targeted with catheter ablation. Reasons may include premature ventricular complex pleomorphism, structurally abnormal PAPs, or unusual origins of VAs from PAP-myocardial connections (PAP-MYCs). OBJECTIVE: The purpose of this study was to correlate PAP anatomy with mapping and ablation of PAP VAs. METHODS: In a series of 43 consecutive patients with frequent PAP arrhythmias referred for ablation, the anatomy and structure of PAPs and VA origins were analyzed using multimodality imaging. Successful ablation sites were analyzed for location on the PAP body or a PAP-MYC. RESULTS: In a total of 17 of 43 patients (40%), VAs originated from a PAP-MYC (in 5 of 17 patients, the PAP inserted into the mitral valve anulus); and in 41 patients, VAs originated from a PAP body. VAs from a PAP-MYC more often had delayed R-wave transition than did other PAP VAs (69% vs 28%; P < .001). Patients with failed procedures had more PAP-MYCs (24.8 ± 8 PAP-MYCs per patient vs 16 ± 7 PAP-MYCs per patient; P < .001). CONCLUSION: Multimodality imaging identifies anatomic details of PAPs that facilitate mapping and ablation of VAs. In more than a third of patients with PAP VAs, VAs originate from connections between PAPs and the surrounding myocardium or between other PAPs. VA electrocardiographic morphologies are different when VAs originate from PAP-connection sites as compared with VAs originating from the PAP body.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Humanos , Músculos Papilares/cirugía , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía , Electrocardiografía , Válvula Mitral/cirugía , Ventrículos Cardíacos
20.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1684-1693, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37354175

RESUMEN

BACKGROUND: The PAINESD (Pulmonary disease, Age, Ischemic cardiomyopathy, NYHA functional class, Ejection fraction, Storm, Diabetes mellitus) risk score has been validated as a predictor of periprocedural acute hemodynamic decompensation (AHD) in patients undergoing ventricular tachycardia (VT) ablation. Whether the addition of total scar volume (TSV) determined by preprocedure computed tomography imaging provides additional risk stratification has not been previously investigated. OBJECTIVES: The purpose of this study was to evaluate the impact of TSV on the risk of AHD and its adjunctive benefit to the PAINESD score newly modified as Pulmonary disease, Age, Ischemic cardiomyopathy, NYHA class, Ejection fraction, Storm, Scar volume, Diabetes mellitus (PAINES2D) based on the addition of scar volumes. METHODS: This was a retrospective analysis of all index VT ablations at a quaternary care center from 2017 to 2022. Associations between TSV and AHD were evaluated among patients with structural heart disease. RESULTS: Among 61 patients with TSV data, 13 (21%) had periprocedural AHD. TSV and PAINESD were independently associated with AHD risk. Both TSV and PAINESD were associated with AHD (P = 0.016 vs P = 0.053, respectively). The highest TSV tertile (≥37.30 mL) showed significant association with AHD (P = 0.018; OR: 4.80) compared to the other tertiles. The PAINESD and PAINES2D scores had significant impact on AHD (P = 0.046 and P = 0.010, respectively). The PAINES2D score had a greater impact on AHD compared to PAINESD (area under the curve: 0.73; P = 0.011; 95% CI: 0.56-0.91 and area under the curve: 0.67; P = 0.058; 95% CI: 0.49-0.85, respectively). CONCLUSIONS: Addition of TSV to a modified PAINESD score, PAINES2D, enhances risk prediction of AHD. Further prospective study is needed to assess benefit in various cardiomyopathy populations undergoing VT ablation.


Asunto(s)
Ablación por Catéter , Hemodinámica , Taquicardia Ventricular , Humanos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Cicatriz/complicaciones , Cicatriz/diagnóstico por imagen , Hemodinámica/fisiología , Estudios Retrospectivos , Medición de Riesgo , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/cirugía , Masculino , Femenino , Anciano , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...