Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Cancers (Basel) ; 16(3)2024 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-38339406

RESUMEN

Suspicious non-calcified mammographic findings have not been evaluated with modern mammographic technique, and the purpose of this work is to compare the likelihood of malignancy for those findings. To do this, 5018 consecutive mammographically guided biopsies performed during 2016-2019 at a large metropolitan, community-based hospital system were retrospectively reviewed. In total, 4396 were excluded for targeting calcifications, insufficient follow-up, or missing data. Thirty-seven of 126 masses (29.4%) were malignant, 44 of 194 asymmetries (22.7%) were malignant, and 77 of 302 architectural distortions (AD, 25.5%) were malignant. The combined likelihood of malignancy was 25.4%. Older age was associated with a higher likelihood of malignancy for each imaging finding type (all p ≤ 0.006), and a possible ultrasound correlation was associated with a higher likelihood of malignancy when all findings were considered together (p = 0.012). Two-view asymmetries were more frequently malignant than one-view asymmetries (p = 0.03). There were two false-negative biopsies (98.7% sensitivity and 100% specificity). In conclusion, the 25.4% likelihood of malignancy confirms the recommendation for biopsy of suspicious, ultrasound-occult, mammographic findings. Mammographically guided biopsies were highly sensitive and specific in this study. Older patient age and a possible ultrasound correlation should raise concern given the increased likelihood of malignancy in those scenarios.

2.
J Am Coll Radiol ; 21(4): 576-588, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37952808

RESUMEN

OBJECTIVE: The coronavirus disease of 2019 (COVID-19) pandemic disproportionately affected certain vulnerable communities. The purpose of our study was to determine how COVID-19 affected the socioeconomic demographics of breast imaging patients at a major comprehensive cancer center. METHODS: This retrospective cohort study compared female patients who underwent screening mammograms, diagnostic mammograms, breast ultrasound, or breast MRI during the following time periods: prepandemic (February 1, 2018, through February 29, 2020), acute pandemic (March 1, 2020, through June 30, 2020), subacute pandemic (August 1, 2020, through December 31, 2020), and chronic pandemic (January 1, 2021, through June 30, 2022). Statistics were performed using the generalized estimating equations approach. RESULTS: A total of 74,398 female patients (mean age, 55.6 ± 12.4 years) underwent 238,776 total breast imaging examinations. For screening mammograms, Hispanics represented 27.1% (9,197 of 33,960) of patients in the prepandemic time period compared with 16.7% (604 of 3,621) in the acute pandemic time period, 18.7% (1,835 of 9,830) in the subacute pandemic time period, and 24.3% (7,492 of 30,869) in the chronic pandemic time period (all P < .0001). Self-pay patients saw similar declines for screening mammograms during the same time periods: 21.7% (7,375 of 33,960), 7.9% (286 of 3,621), 9.5% (933 of 9,830), and 17.4% (5,357 of 30,869), respectively (all P < .0001, compared with the prepandemic time period). Similarly dramatic trends were not observed for race or other imaging examinations. DISCUSSION: At our cancer center, Hispanics and self-pay patients were disproportionately affected by the COVID-19 pandemic. Strategies to improve health inequities are needed.


Asunto(s)
Neoplasias de la Mama , COVID-19 , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Pandemias , Estudios Retrospectivos , COVID-19/epidemiología , Mamografía , Demografía , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/epidemiología
3.
Diagnostics (Basel) ; 13(13)2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-37443627

RESUMEN

RATIONALE AND OBJECTIVES: Information evaluating the efficacy of 2D synthesized mammography (2Ds) reconstructions in microcalcification detection is limited. This study used stereotactic biopsy data for microcalcifications to evaluate the stepwise implementation of 2Ds in screening mammography. The study aim was to identify whether 2Ds + digital breast tomosynthesis (DBT) is non-inferior to 2D digital mammography (2DM) + 2Ds + DBT, 2DM + DBT, and 2DM in identifying microcalcifications undergoing further diagnostic imaging and stereotactic biopsy. MATERIALS AND METHODS: Retrospective stereotactic biopsy data were extracted following 151,736 screening mammograms of healthy women (average age, 56.3 years; range, 30-89 years), performed between 2012 and 2019. The stereotactic biopsy data were separated into 2DM, 2DM + DBT, 2DM + 2Ds + DBT, and 2Ds + DBT arms and examined using Fisher's exact test to compare the detection rates of all cancers, invasive cancers, DCIS, and ADH between modalities for patients undergoing stereotactic biopsy of microcalcifications. RESULTS: No statistical significance in cancer detection was seen for 2Ds + DBT among those calcifications that underwent stereotactic biopsy when comparing the 2Ds + DBT to 2DM, 2DM + DBT, and 2DM + 2Ds + DBT imaging combinations. CONCLUSION: These data suggest that 2Ds + DBT is non-inferior to 2DM + DBT in detecting microcalcifications that will undergo stereotactic biopsy.

4.
Eur Radiol ; 33(9): 6189-6203, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37042980

RESUMEN

OBJECTIVES: Compare prone and upright, stereotactic, and tomosynthesis-guided vacuum-assisted breast biopsies (prone DM-VABB, prone DBT-VABB, upright DM-VABB, and upright DBT-VABB) in a community-practice setting and review outcomes of ultrasound-occult architectural distortions (AD). METHODS: Consecutive biopsies performed at two community-based breast centers from 2016 to 2019 were retrospectively reviewed. Technical details of each procedure and patient outcomes were recorded. Separate analyses were performed for ultrasound-occult ADs. Two sample t-tests and Fisher's exact test facilitated comparisons. RESULTS: A total of 1133 patients underwent 369 prone DM-VABB, 324 prone DBT-VABB, 437 upright DM-VABB, and 123 upright DBT-VABB with 99.2%, 100%, 99.3%, and 99.2% success, respectively (p-values > 0.25). Mean lesion targeting times were greater for prone biopsy (minutes: 6.94 prone DM-VABB, 8.54 prone DBT-VABB, 5.52 upright DM-VABB, and 5.51 upright DBT-VABB; p-values < 0.001), yielding longer total prone procedure times for prone biopsy (p < 0.001). Compared to DM-VABB, DBT-VABB used fewer exposures (p < 0.001) and more commonly targeted AD, asymmetries, or masses (p < 0.001). Malignancy rates were similar between procedures: prone DM-VABB 22.4%, prone DBT-VABB 21.9%, upright DM-VABB 22.8%, and upright DBT-VABB 17.2% (p-values > 0.19). One hundred forty of the 1133 patients underwent 145 biopsies for ultrasound-occult AD (143 DBT-VABB and 2 DM-VABB). Biopsy yielded 27 malignancies and 47 high-risk lesions (74 of 145, 51%). Malignancy rate was 20.7% after surgical upgrade of one benign-discordant and two high-risk lesions. CONCLUSIONS: All biopsy procedure types were extremely successful. The 20.7% malignancy rate for ultrasound-occult AD confirms a management recommendation for tissue diagnosis. Upright biopsy was faster than prone biopsy, and DBT-VABB used fewer exposures than DM-VABB. CLINICAL RELEVANCE: Our results highlight important differences between prone DM-VABB, prone DBT-VABB, upright DM-VABB, and upright DBT-VABB. Moreover, the high likelihood of malignancy for ultrasound-occult AD will provide confidence in recommending tissue diagnosis in lieu of observation or clinical follow-up. KEY POINTS: • Upright and prone stereotactic and tomosynthesis-guided breast biopsies were safe and effective in the community-practice setting. • The malignancy rate for ultrasound-occult architectural distortion of 20.7% confirms the management recommendation for biopsy. • Upright procedures were faster than prone procedures, and tomosynthesis-guided biopsy used fewer exposures than stereotactic biopsy.


Asunto(s)
Neoplasias de la Mama , Mamografía , Humanos , Femenino , Mamografía/métodos , Estudios Retrospectivos , Mama/diagnóstico por imagen , Mama/patología , Biopsia Guiada por Imagen/métodos , Biopsia con Aguja/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología
6.
Insights Imaging ; 12(1): 193, 2021 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-34931266

RESUMEN

BACKGROUND: Mammography-guided vacuum-assisted biopsies (MGVAB) can be done with stereotaxis or digital breast tomosynthesis guidance. Both methods can be performed with a conventional (CBA) or a lateral arm biopsy approach (LABA). Marker clip migration is relatively frequent in MGVAB (up to 44%), which in cases requiring surgery carries a risk of positive margins and re-excision. We aimed to compare the rates of clip migration and hematoma formation between the CBA and LABA techniques of prone MGVAB. Our HIPAA compliant retrospective study included all consecutive prone MGVAB performed in a single institution over a 20-month period. The LABA approach was used with DBT guidance; CBA utilized DBT or stereotactic guidance. The tissue sampling techniques were otherwise identical. RESULTS: After exclusion, 389 biopsies on 356 patients were analyzed. LABA was done in 97 (25%), and CBA in 292 (75%) cases. There was no statistical difference in clip migration rate with either 1 cm or 2 cm distance cut-off [15% for CBA and 10% for LABA for 1 cm threshold (p = 0.31); 5.8% or CBA and 3.1% or LABA for 2 cm threshold (p = 0.43)]. There was no difference in the rate of hematoma formation (57.5% in CDB and 50.5% in LABA, p = 0.24). The rates of technical failure were similar for both techniques (1.7% for CBA and 3% for LABA) with a combined failure rate of 1%. CONCLUSIONS: LABA and CBA had no statistical difference in clip migration or hematoma formation rates. Both techniques had similar success rates and may be helpful in different clinical situations.

7.
Radiol Artif Intell ; 3(4): e200097, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34350403

RESUMEN

PURPOSE: To develop a computational approach to re-create rarely stored for-processing (raw) digital mammograms from routinely stored for-presentation (processed) mammograms. MATERIALS AND METHODS: In this retrospective study, pairs of raw and processed mammograms collected in 884 women (mean age, 57 years ± 10 [standard deviation]; 3713 mammograms) from October 5, 2017, to August 1, 2018, were examined. Mammograms were split 3088 for training and 625 for testing. A deep learning approach based on a U-Net convolutional network and kernel regression was developed to estimate the raw images. The estimated raw images were compared with the originals by four image error and similarity metrics, breast density calculations, and 29 widely used texture features. RESULTS: In the testing dataset, the estimated raw images had small normalized mean absolute error (0.022 ± 0.015), scaled mean absolute error (0.134 ± 0.078) and mean absolute percentage error (0.115 ± 0.059), and a high structural similarity index (0.986 ± 0.007) for the breast portion compared with the original raw images. The estimated and original raw images had a strong correlation in breast density percentage (Pearson r = 0.946) and a strong agreement in breast density grade (Cohen κ = 0.875). The estimated images had satisfactory correlations with the originals in 23 texture features (Pearson r ≥ 0.503 or Spearman ρ ≥ 0.705) and were well complemented by processed images for the other six features. CONCLUSION: This deep learning approach performed well in re-creating raw mammograms with strong agreement in four image evaluation metrics, breast density, and the majority of 29 widely used texture features.Keywords: Mammography, Breast, Supervised Learning, Convolutional Neural Network (CNN), Deep learning algorithms, Machine Learning AlgorithmsSee also the commentary by Chan in this issue.Supplemental material is available for this article.©RSNA, 2021.

8.
J Breast Imaging ; 3(3): 354-362, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34056594

RESUMEN

OBJECTIVE: To determine the impact of the COVID-19 pandemic on breast imaging education. METHODS: A 22-item survey addressing four themes during the early pandemic (time on service, structured education, clinical training, future plans) was emailed to Society of Breast Imaging members and members-in-training in July 2020. Responses were compared using McNemar's and Mann-Whitney U tests; a general linear model was used for multivariate analysis. RESULTS: Of 136 responses (136/2824, 4.8%), 96 U.S. responses from radiologists with trainees, residents, and fellows were included. Clinical exposure declined during the early pandemic, with almost no medical students on service (66/67, 99%) and fewer clinical days for residents (78/89, 88%) and fellows (48/68, 71%). Conferences shifted to remote live format (57/78, 73%), with some canceled (15/78, 19%). Compared to pre-pandemic, resident diagnostic (75/78, 96% vs 26/78, 33%) (P < 0.001) and procedural (73/78, 94% vs 21/78, 27%) (P < 0.001) participation fell, as did fellow diagnostic (60/61, 98% vs 47/61, 77%) (P = 0.001) and procedural (60/61, 98% vs 43/61, 70%) (P < 0.001) participation. Most thought that the pandemic negatively influenced resident and fellow screening (64/77, 83% and 43/60, 72%, respectively), diagnostic (66/77, 86% and 37/60, 62%), and procedural (71/77, 92% and 37/61, 61%) education. However, a majority thought that decreased time on service (36/67, 54%) and patient contact (46/79, 58%) would not change residents' pursuit of a breast imaging fellowship. CONCLUSION: The pandemic has had a largely negative impact on breast imaging education, with reduction in exposure to all aspects of breast imaging. However, this may not affect career decisions.

9.
Eur Radiol ; 31(12): 9499-9510, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34014380

RESUMEN

OBJECTIVES: Compare four groups being screened: women without breast implants undergoing digital mammography (DM), women without breast implants undergoing DM with digital breast tomosynthesis (DM/DBT), women with implants undergoing DM, and women with implants undergoing DM/DBT. METHODS: Mammograms from February 2011 to March 2017 were retrospectively reviewed after 13,201 were excluded for a unilateral implant or prior breast cancer. Patients had been allowed to choose between DM and DM/DBT screening. Mammography performance metrics were compared using chi-square tests. RESULTS: Six thousand forty-one women with implants and 91,550 women without implants were included. In mammograms without implants, DM (n = 113,973) and DM/DBT (n = 61,896) yielded recall rates (RRs) of 8.53% and 6.79% (9726/113,973 and 4204/61,896, respectively, p < .001), cancer detection rates per 1000 exams (CDRs) of 3.96 and 5.12 (451/113,973 and 317/61,896, respectively, p = .003), and positive predictive values for recall (PPV1s) of 4.64% and 7.54% (451/9726 and 317/4204, respectively, p < .001), respectively. In mammograms with implants, DM (n = 6815) and DM/DBT (n = 5138) yielded RRs of 5.81% and 4.87% (396/6815 and 250/5138, respectively, p = .158), CDRs of 2.49 and 2.92 (17/6815 and 15/5138, respectively, p > 0.999), and PPV1s of 4.29% and 6.0% (17/396 and 15/250, respectively, p > 0.999), respectively. CONCLUSIONS: DM/DBT significantly improved recall rates, cancer detection rates, and positive predictive values for recall compared to DM alone in women without implants. DM/DBT performance in women with implants trended towards similar improvements, though no metric was statistically significant. KEY POINTS: • Digital mammography with tomosynthesis improved recall rates, cancer detection rates, and positive predictive values for recall compared to digital mammography alone for women without implants. • Digital mammography with tomosynthesis trended towards improving recall rates, cancer detection rates, and positive predictive values for recall compared to digital mammography alone for women with implants, but these trends were not statistically significant - likely related to sample size.


Asunto(s)
Neoplasias de la Mama , Detección Precoz del Cáncer , Mamografía/métodos , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Tamizaje Masivo , Estudios Retrospectivos
10.
J Am Coll Radiol ; 18(2): 280-293, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32861601

RESUMEN

OBJECTIVE: To compare batch reading and interrupted interpretation for modern screening mammography. METHODS: We retrospectively reviewed digital mammograms without and with tomosynthesis that were originally interpreted with batch reading or interrupted interpretation between January 2015 and June 2017. The following performance metrics were compared: recall rate (per 100 examinations), cancer detection rate (per 1,000 examinations), and positive predictive values for recall and biopsy. RESULTS: In all, 9,832 digital mammograms were batch read, yielding a recall rate of 9.98%, cancer detection rate of 4.27, and positive predictive values for recall and biopsy of 4.40% and 35.5%, respectively. There were 49,496 digital mammograms that were read with interrupted interpretation, yielding a recall rate of 11.3%, cancer detection rate of 4.44, and positive predictive values for recall and biopsy of 3.92% and 30.1%, respectively. Of the digital mammograms with tomosynthesis, 7,075 were batch read, yielding a recall rate of 6.98%, cancer detection rate of 5.37, and positive predictive values for recall and biopsy of 7.69% and 38.0%, respectively. Of the digital mammograms with tomosynthesis, 24,380 were read with interrupted interpretation, yielding a recall rate of 8.30%, cancer detection rate of 5.41, and positive predictive values for recall and biopsy of 6.52% and 33.3%, respectively. For both digital mammograms without and with tomosynthesis, recall rates improved with batch reading compared with interrupted interpretation (P < .001), but no significant differences were seen for other metrics. DISCUSSION: Batch reading digital mammograms without and with tomosynthesis improves recall rates while maintaining cancer detection rates and positive predictive values compared with interrupted interpretation.


Asunto(s)
Neoplasias de la Mama , Mamografía , Neoplasias de la Mama/diagnóstico por imagen , Detección Precoz del Cáncer , Femenino , Humanos , Tamizaje Masivo , Lectura , Estudios Retrospectivos
11.
J Breast Imaging ; 3(3): 343-353, 2021 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38424771

RESUMEN

OBJECTIVE: To determine the early impact of the COVID-19 pandemic on breast imaging centers in California and Texas and compare regional differences. METHODS: An 11-item survey was emailed to American College of Radiology accredited breast imaging facilities in California and Texas in August 2020. A question subset addressed March-April government restrictions on elective services ("during the shutdown" and "after reopening"). Comparisons were made between states with chi-square and Fisher's tests, and timeframes with McNemar's and paired t-tests. RESULTS: There were 54 respondents (54/240, 23%, 26 California, 28 Texas). Imaging volumes fell during the shutdown and remained below pre-pandemic levels after reopening, with reduction in screening greatest (ultrasound 12% of baseline, mammography 13%, MRI 23%), followed by diagnostic MRI (43%), procedures (44%), and diagnostics (45%). California reported higher volumes during the shutdown (procedures, MRI) and after reopening (diagnostics, procedures, MRI) versus Texas (P = 0.001-0.02). Most screened patients (52/54, 96% symptoms and 42/54, 78% temperatures), and 100% (53/53) modified check-in and check-out. Reading rooms or physician work were altered for social distancing (31/54, 57%). Physician mask (45/48, 94%), gown (15/48, 31%), eyewear (22/48, 46%), and face shield (22/48, 46%) use during procedures increased after reopening versus pre-pandemic (P < 0.001-0.03). Physician (47/54, 87%) and staff (45/53, 85%) financial impacts were common, but none reported terminations. CONCLUSION: Breast imaging volumes during the early pandemic fell more severely in Texas than in California. Safety measures and financial impacts on physicians and staff were similar in both states.

12.
AJR Am J Roentgenol ; 214(2): 276-281, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31825259

RESUMEN

OBJECTIVE. Historically, management recommendations for multiple bilateral circumscribed breast masses encountered with breast imaging have varied. This article reviews the evidence and provides best-practice recommendations for managing these masses. CONCLUSION. Meticulous imaging technique and interpretation are required to correctly diagnose multiple bilateral circumscribed breast masses. Radiologists should classify such masses identified at mammography, digital breast tomosynthesis, or bilateral whole-breast sonography as benign and recommend annual follow-up. Elucidating the significance of these masses on MRI, contrast-enhanced mammography, or nuclear breast imaging requires further study.


Asunto(s)
Enfermedades de la Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias Primarias Múltiples/diagnóstico por imagen , Biopsia con Aguja Gruesa , Enfermedades de la Mama/patología , Neoplasias de la Mama/patología , Diagnóstico Diferencial , Femenino , Humanos , Neoplasias Primarias Múltiples/patología
14.
AJR Am J Roentgenol ; 211(2): 445-451, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29792742

RESUMEN

OBJECTIVE: The purpose of this article is to compare outcomes of findings seen on one view only from screening full-field digital mammography (FFDM) and FFDM plus digital breast tomosynthesis (DBT). MATERIALS AND METHODS: A retrospective review was performed of 103,070 consecutive screening mammograms obtained from February 2011 through June 2014 at two community-based breast centers. Recalled findings prospectively seen on one view only were analyzed. Pearson chi-square test and Fisher exact test were performed, and 95% CIs were determined. RESULTS: Mammograms were acquired using FFDM (n = 71,656) and FFDM-DBT (n = 31,414) during the study period, and 2213 FFDM (3.1%) and 433 FFDM-DBT (1.4%) mammograms were recalled for one-view-only findings (p < 0.0001). The final study population (1592 FFDM and 354 FFDM-DBT) was defined after 689 of these recalled FFDM and 92 of these recalled FFDM-DBT examinations were excluded for insufficient mammographic follow-up (< 24 months). Summation artifacts accounted for more one-view-only findings from FFDM (1067/1592; 67.0%) than FFDM-DBT (190/354; 53.7%) (p < 0.0001). In the FFDM cohort, 28 one-view-only findings proved malignant (24 invasive ductal carcinoma [IDC], one invasive lobular carcinoma [ILC], and three ductal carcinoma in situ [DCIS]). In the FFDM-DBT cohort, 14 one-view-only findings proved malignant (11 IDC, one ILC, and two DCIS). The positive predictive value (PPV) of a one-view-only finding was significantly lower for FFDM (1.8%) than for FFDM-DBT (4.0%) (p = 0.010). CONCLUSION: One-view-only findings occur with both FFDM and FFDM-DBT and remain an important but uncommon sign of malignancy. They are more frequent, are more likely to represent summation artifacts, and have a lower PPV with FFDM than with FFDM-DBT.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Adulto , Anciano , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Tamizaje Masivo , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...