Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Heliyon ; 10(16): e36592, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39258195

RESUMEN

Diabetes is one of the leading causes of morbidity and mortality in the United States and worldwide. Traditionally, diabetes detection from retinal images has been performed only using relevant retinopathy indications. This research aimed to develop an artificial intelligence (AI) machine learning model which can detect the presence of diabetes from fundus imagery of eyes without any diabetic eye disease. A machine learning algorithm was trained on the EyePACS dataset, consisting of 47,076 images. Patients were also divided into cohorts based on disease duration, each cohort consisting of patients diagnosed within the timeframe in question (e.g., 15 years) and healthy participants. The algorithm achieved 0.86 area under receiver operating curve (AUC) in detecting diabetes per patient visit when averaged across camera models, and AUC 0.83 on the task of detecting diabetes per image. The results suggest that diabetes may be diagnosed non-invasively using fundus imagery alone. This may enable diabetes diagnosis at point of care, as well as other, accessible venues, facilitating the diagnosis of many undiagnosed people with diabetes.

2.
Semin Ophthalmol ; : 1-4, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39028204

RESUMEN

PURPOSE: To assess a novel Virtual Reality (VR) tool designed to enhance understanding of the nasal anatomy in patients eligible for DCR surgery. METHODS: Preoperative Computed Tomography (CT) scans of the orbit were obtained and loaded as DICOM (Digital Imaging and Communications in Medicine) files onto the D2P software (3D Systems Inc. Littleton, CO) for tissue segmentation and 3D model preparation. Segmentation was performed on several anatomical structures, including the skull, lacrimal sac, nasal septum, inferior and middle turbinate. The resulting 3D model was visualized using a VR headset. After completing the segmentation procedure, ten cases were evaluated by a panel of six surgeons, including both senior and resident physicians from ENT and oculoplastic specialties. RESULTS: The dataset under examination comprised images from 10 preoperative CT scans of the orbits of patients eligible for Endo-DCR. When evaluating the CT using the VR tool, in 73.3% of the cases ENT surgeons were right about the side of pathology, while only 43.3% ophthalmologists were right (chi-square, p = .018). In 72.8% of the cases ENT surgeons were evaluated right that there is a septum deviation, while only in 47.2% of the cases the ophthalmologists were right (chi-square, p = .094).When evaluating the CT using the VR tool, in 60% of the cases consultants were right about the pathology, while 57.7% of the residents were right (chi-square, p = .853). In 81.7% of the cases consultants were evaluated right that there is a septum deviation, while only in 58.3% of the cases the ophthalmologists were right (chi-square, p = .198). DISCUSSION: ENT surgeons, as well as consultants, interpreted the CT better than the ophthalmologists and residents. Surprisingly, the VR system did not help them to interpret the CT better. Further, more extensive studies should be done to build a VR system that assists in the correct interpretation of the preoperative CT before DCR surgery as well as during DCR surgery.

3.
BMC Ophthalmol ; 24(1): 218, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38773500

RESUMEN

PURPOSE: Comparing between the visual outcomes and post operative complications of two surgical treatments for sub macular hemorrhage, pars plana vitrectomy with tissue plasminogen activator (tPA) injection procedure, and pneumatic displacement of submacular hemorrhage with intravitreal tPA injection. METHODS: A retrospective chart review of patients with sub macular hemorrhage (SMH) was performed. Data was collected from 150 patients with sub macular hemorrhage. Patients were followed up from the day of admission and up to a year post surgery. Evaluation included visual acuity, optical coherence tomography (OCT), fundus examination and rates of complications. RESULTS: Pars plana vitrectomy procedure has showed a better visual outcome in small SMH. Comparing complications between the two treatment modalities, no significant difference has been found in the study. CONCLUSIONS: Pars plana vitrectomy and tPA showed a clear advantage with a trend of better visual acuity as well as a significant predictor to better visual acuity for small and medium sub macular hemorrhage.


Asunto(s)
Fibrinolíticos , Inyecciones Intravítreas , Hemorragia Retiniana , Activador de Tejido Plasminógeno , Tomografía de Coherencia Óptica , Agudeza Visual , Vitrectomía , Humanos , Activador de Tejido Plasminógeno/administración & dosificación , Vitrectomía/métodos , Hemorragia Retiniana/terapia , Hemorragia Retiniana/diagnóstico , Hemorragia Retiniana/tratamiento farmacológico , Estudios Retrospectivos , Masculino , Femenino , Anciano , Fibrinolíticos/administración & dosificación , Persona de Mediana Edad , Anciano de 80 o más Años
4.
J Clin Med ; 12(23)2023 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-38068531

RESUMEN

Retinal vein occlusion (RVO) results in ischemia followed by an inflammatory response. Both processes affect tissue temperature in opposite directions. Here, we evaluate the effect of RVO on the ocular surface temperature (OST) profile. Subjects with RVO were prospectively recruited. Healthy subjects without any ocular disease served as controls. The OST was determined using the Therm-App thermal imaging camera, and image processing software was employed to compute the mean temperature values of the medial canthus, lateral canthus, and cornea. We obtained thermographic images from 30 RVO subjects (30 eyes) and 148 controls (148 eyes). A univariate analysis found that eyes with RVO had significantly elevated OSTs compared to the controls (mean difference of 0.6 ± 0.3 Celsius, p < 0.05). However, this distinction between the groups lost statistical significance upon adjusting for possible confounders, including patient and environmental factors. These findings were confirmed with a post hoc case-control matched comparison. In conclusion, RVO does not seem to affect the OST. This might be due to the balance between inflammatory thermogenesis and heat constriction from ischemia in RVO. It is also possible that, in our cohort, the RVO pathophysiological processes involved were localized and did not extend to the anterior segment. Patient and environmental factors must be considered when interpreting the OST.

5.
Diagnostics (Basel) ; 11(10)2021 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-34679576

RESUMEN

PURPOSE: To characterize ocular surface temperature (OST) in healthy eyes and its association with systemic risk factors of cardiovascular and ischemic heart disease. METHODS: This prospective cross-sectional study included consenting subjects who were examined at the Institute for Medical Screening in Sheba Medical Center. A Therm-App™ thermal imaging camera (Opgal LTD, Israel) was used for OST acquisition, and the mean OST of the medial canthal, lateral canthal, and central cornea regions were measured. Room and body temperatures were also recorded. Past medical and ocular history as well as data from various clinical examinations performed at the same visit were obtained. RESULTS: Thermographic images were obtained from 186 subjects, 150 of which were included in the final analysis. OST was significantly higher in the medial canthal, central cornea, and lateral canthal regions in people with a history of ischemic heart disease (p = 0.02, p = 0.02, and p = 0.03, respectively). There were no significant OST differences (ANOVA test) associated with the presence of hypertension, diabetes mellitus, or active smoking status. CONCLUSIONS: OST correlated positively with the presence of ischemic heart disease. This correlation, its pathophysiological base, and its clinical application warrants further investigation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA