Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Brachytherapy ; 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39112321

RESUMEN

BACKGROUND AND PURPOSE: The upgrade of major equipment can be disruptive to clinical operations and introduce risk as policy and procedures need to adapt to new technical possibilities and constraints. We describe here the transition from GammaMedPlus-iX to Bravos in a busy brachytherapy clinic, involving four afterloaders across two sites. MATERIAL AND METHODS: Our clinic employs three high-dose-rate remote afterloaders in four dedicated treatment vaults at the main site and a fourth afterloader at a regional location. Of more than 600 new HDR treatment plans performed annually, most are planned and treated intraoperatively. Most treatments are for prostate cancer, followed by GYN, intraoperative brachytherapy, GI, and other sites. Applicators used include vendor-provided applicators as well as third party applicators and in-house 3D-printed devices to provide interstitial, intracavitary, intraluminal, and surface treatments. All applicators were commissioned according to recommended guidelines. The choice of tolerances and the design of new procedures were informed by current guidelines and leveraged new HDR afterloader functionalities. A review of clinical operations in the 4 months postupgrade was conducted to evaluate the feasibility of new tolerances and the effectiveness of new procedures. RESULTS: The procedures outlined improved and standardized afterloader QA and treatment protocols with clear actionable steps for staff to follow to ensure treatments are delivered as planned. Re-commissioning of applicators yielded results similar to those previously reported by other investigators. A review of initial treatment data revealed that in one case, due to the implementation of tight tolerances, obstruction near the tip of the channel was detected and corrected prior to treatment. It confirms that the implementation of the tolerances adopted is feasible and effective in flagging treatment deviations. CONCLUSION: Enhanced procedures and QA processes were implemented successfully. We established clear actionable steps to follow by staff to ensure that treatments are delivered accurately.

2.
Cancers (Basel) ; 16(13)2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-39001374

RESUMEN

The initial favorable efficacy and safety profile for Alpha DaRT have been demonstrated (NCT04377360); however, the longer-term safety and durability of the treatment are unknown. This pooled analysis of four prospective trials evaluated the long-term safety and efficacy of Alpha DaRT for the treatment of head and neck or skin tumors. A total of 81 lesions in 71 patients were treated across six international institutions, with a median follow-up of 14.1 months (range: 2-51 months). Alpha DaRT sources were delivered via a percutaneous interstitial technique and placed to irradiate the tumor volume with the margin. The sources were removed two to three weeks following implantation. A complete response was observed in 89% of treated lesions (n = 72) and a partial response in 10% (n = 8). The two-year actuarial local recurrence-free survival was 77% [95% CI 63-87]. Variables, including recurrent versus non-recurrent lesions, baseline tumor size, or histology, did not impact long-term outcomes. Twenty-seven percent of patients developed related acute grade 2 or higher toxicities, which resolved with conservative measures. No grade 2 or higher late toxicities were observed. These data support the favorable safety profile of Alpha DaRT, which is currently being explored in a pivotal US trial.

3.
Med Phys ; 51(6): 3822-3849, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38648857

RESUMEN

Use of magnetic resonance (MR) imaging in radiation therapy has increased substantially in recent years as more radiotherapy centers are having MR simulators installed, requesting more time on clinical diagnostic MR systems, or even treating with combination MR linear accelerator (MR-linac) systems. With this increased use, to ensure the most accurate integration of images into radiotherapy (RT), RT immobilization devices and accessories must be able to be used safely in the MR environment and produce minimal perturbations. The determination of the safety profile and considerations often falls to the medical physicist or other support staff members who at a minimum should be a Level 2 personnel as per the ACR. The purpose of this guidance document will be to help guide the user in making determinations on MR Safety labeling (i.e., MR Safe, Conditional, or Unsafe) including standard testing, and verification of image quality, when using RT immobilization devices and accessories in an MR environment.


Asunto(s)
Inmovilización , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/instrumentación , Humanos , Inmovilización/instrumentación , Radioterapia Guiada por Imagen/instrumentación
4.
JAMA Netw Open ; 6(5): e2312824, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-37166798

RESUMEN

Importance: Patients with recurrent or unresectable skin cancers have limited treatment options. Diffusing alpha-emitter radiation therapy (DaRT), a novel solid tumor management strategy using alpha-particle interstitial brachytherapy, may address this challenge. Objective: To evaluate the feasibility and safety of using DaRT to manage recurrent or unresectable skin cancers. Design, Setting, and Participants: This prospective cohort study of patients who received a 2-week to 3-week treatment course and were followed up for 24 weeks after treatment during 2021 and 2022 at 2 sites in the US. Patients with malignant skin tumors or soft tissue tumors were recruited if they had limited treatment options for tumors recurrent after prior surgery or external beam radiotherapy or unresectable tumors. Intervention: Patients underwent DaRT to deliver a physical dose of 10 Gy (equivalent weighted dose of 200 CGE) to the tumor. Main Outcomes and Measures: Feasibility of the DaRT procedure was evaluated based on the ability of investigators to successfully deliver radiation to the tumor. Patients were followed up for adverse events (AEs) for 24 weeks and for tumor response by physicians' physical examination and imaging 12 weeks after device removal. Results: This study included 10 participants with recurrent or unresectable skin cancer (median [IQR] age, 72 [68-75] years; 6 males [60%]; 4 females [40%]). Six patients (60%) had recurrent disease, and 4 (40%) had tumors that were deemed unresectable. Tumors were located on the nose, chin, eyelid, scalp, neck, trunk, and extremities. Median (range) tumor volume before treatment was 2.1 cm3 (0.65-12.65 cm3). The mean (SD) prescription dose coverage of the gross tumor volume was 91% (2.8%) with all tumors having coverage of 85% or more. No device-related grade 3 AEs were noted. Common AEs were grade 1 to 2 erythema, edema, and pruritus. At 12 weeks following treatment, there was a 100% complete response rate. Nine of 10 complete responses (90%) were confirmed by CT imaging. Conclusions and Relevance: This cohort study suggests the feasibility and preliminary safety of DaRT in the management of recurrent or unresectable skin cancers. The favorable safety profile and high response rates are promising. A US trial for marketing approval based on this pilot study is under way. Trial Registration: ClinicalTrials.gov Identifier: NCT04377360.


Asunto(s)
Braquiterapia , Neoplasias Cutáneas , Masculino , Femenino , Humanos , Anciano , Braquiterapia/efectos adversos , Estudios de Cohortes , Estudios Prospectivos , Proyectos Piloto , Estudios de Factibilidad , Neoplasias Cutáneas/radioterapia
5.
J Appl Clin Med Phys ; 24(3): e13829, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36808798

RESUMEN

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines (MPPGs) will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: (1) Must and must not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. (2) Should and should not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances. Approved by AAPM's Executive Committee April 28, 2022.


Asunto(s)
Braquiterapia , Oncología por Radiación , Humanos , Estados Unidos , Física Sanitaria/educación , Sociedades
7.
Int J Radiat Oncol Biol Phys ; 116(3): 544-550, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-36586493

RESUMEN

PURPOSE: Keratinocyte carcinomas are amenable to many treatments, including radiation therapy (RT). Electronic skin surface brachytherapy (ESSB) enables the precise delivery of radiation without radioisotopes. In this prospective multicenter clinical trial, we characterized early outcomes of ESSB prospectively through both patient- and clinician-reported measures. To corroborate the cosmesis observations, we also assessed patient-reported quality of life (QoL) and adverse events. METHODS AND MATERIALS: Patients ≥60 years old with stage T1N0M0 keratinocyte carcinoma were treated with ESSB. At 2-, 6-, and 12-weeks post-treatment, cosmesis from ESSB was assessed by both the patient and a clinician study investigator as either "good," "fair," or "bad." The Skindex-16 and the Skin Cancer Index (SCI) were used to assess patient QoL before and after treatment. Adverse events were assessed using the Common Toxicity Criteria for Adverse Events, version 4.0. RESULTS: Cosmesis and QoL were collected at 97% (99/102) of possible patient follow-up times. By 12 weeks post-treatment, 93.9% (31/33) of patient-reported and 96.9% (31/32) of clinician-reported cosmesis outcomes were "good." Compared with baseline, total Skindex-16 score significantly deteriorated at 2 weeks post-treatment (10.5 vs 24.5, P <.001), but significantly improved at 6 weeks (10.5 vs 4.7, P = .014) and 12 weeks (10.5 vs 2.1, P = .001) post-treatment. The total SCI score significantly improved from baseline to 6 weeks (78.4 vs 89.0, P = .001) post-treatment. The most frequent adverse events were radiation dermatitis, skin pain, and pruritus. All adverse events resolved to Grade ≤1 by 12 weeks post-treatment. CONCLUSIONS: This prospective, multicenter study demonstrated that ESSB is associated with a high rate of "good" early patient-reported cosmesis and increasing QoL and satisfaction with time. Validated assessments demonstrated a significant improvement in quality of life and resolution of moderate early adverse events by 6 to 12 weeks after treatment and corroborate the observation of favorable cosmesis.


Asunto(s)
Braquiterapia , Neoplasias de la Mama , Carcinoma , Neoplasias Cutáneas , Humanos , Persona de Mediana Edad , Femenino , Calidad de Vida , Estudios Prospectivos , Braquiterapia/efectos adversos , Braquiterapia/métodos , Neoplasias Cutáneas/radioterapia , Neoplasias de la Mama/etiología
9.
J Neurooncol ; 159(3): 609-618, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35896906

RESUMEN

BACKGROUND: Salvage of recurrent previously irradiated brain metastases (rBrM) is a significant challenge. Resection without adjuvant re-irradiation is associated with a high local failure rate, while reirradiation only partially reduces failure but is associated with greater radiation necrosis risk. Salvage resection plus Cs131 brachytherapy may offer dosimetric and biologic advantages including improved local control versus observation, with reduced normal brain dose versus re-irradiation, however data are limited. METHODS: A prospective registry of consecutive patients with post-stereotactic radiosurgery (SRS) rBrM undergoing resection plus implantation of collagen-matrix embedded Cs131 seeds (GammaTile, GT Medical Technologies) prescribed to 60 Gy at 5 mm from the cavity was analyzed. RESULTS: Twenty patients underwent 24 operations with Cs131 implantation in 25 tumor cavities. Median maximum preoperative diameter was 3.0 cm (range 1.1-6.3). Gross- or near-total resection was achieved in 80% of lesions. A median of 16 Cs131 seeds (range 6-30), with a median air-kerma strength of 3.5 U/seed were implanted. There was one postoperative wound dehiscence. With median follow-up of 1.6 years for survivors, two tumors recurred (one in-field, one marginal) resulting in 8.4% 1-year progression incidence (95%CI = 0.0-19.9). Radiographic seed settling was identified in 7/25 cavities (28%) 1.9-11.7 months post-implantation, with 1 case of distant migration (4%), without clinical sequelae. There were 8 cases of radiation necrosis, of which 4 were symptomatic. CONCLUSIONS: With > 1.5 years of follow-up, intraoperative brachytherapy with commercially available Cs131 implants was associated with favorable local control and toxicity profiles. Weak correlation between preoperative tumor geometry and implanted tiles highlights a need to optimize planning criteria.


Asunto(s)
Productos Biológicos , Braquiterapia , Neoplasias Encefálicas , Traumatismos por Radiación , Radiocirugia , Braquiterapia/métodos , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirugía , Radioisótopos de Cesio , Colágeno , Humanos , Necrosis , Recurrencia Local de Neoplasia/complicaciones , Recurrencia Local de Neoplasia/radioterapia , Recurrencia Local de Neoplasia/cirugía , Traumatismos por Radiación/etiología , Radiocirugia/efectos adversos , Radiocirugia/métodos , Estudios Retrospectivos , Resultado del Tratamiento
10.
Med Phys ; 49(8): e983-e1023, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35662032

RESUMEN

The task group (TG) on magnetic resonance imaging (MRI) implementation in high-dose-rate (HDR) brachytherapy (BT)-Considerations from simulation to treatment, TG 303, was constituted by the American Association of Physicists in Medicine's (AAPM's) Science Council under the direction of the Therapy Physics Committee, the Brachytherapy Subcommittee, and the Working Group on Brachytherapy Clinical Applications. The TG was charged with developing recommendations for commissioning, clinical implementation, and on-going quality assurance (QA). Additionally, the TG was charged with describing HDR BT workflows and evaluating practical consideration that arise when implementing MR imaging. For brevity, the report is focused on the treatment of gynecologic and prostate cancer. The TG report provides an introduction and rationale for MRI implementation in BT, a review of previous publications on topics including available applicators, clinical trials, previously published BT-related TG reports, and new image-guided recommendations beyond CT-based practices. The report describes MRI protocols and methodologies, including recommendations for the clinical implementation and logical considerations for MR imaging for HDR BT. Given the evolution from prescriptive to risk-based QA, an example of a risk-based analysis using MRI-based, prostate HDR BT is presented. In summary, the TG report is intended to provide clear and comprehensive guidelines and recommendations for commissioning, clinical implementation, and QA for MRI-based HDR BT that may be utilized by the medical physics community to streamline this process. This report is endorsed by the American Brachytherapy Society.


Asunto(s)
Braquiterapia , Neoplasias de la Próstata , Braquiterapia/métodos , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Próstata , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Estados Unidos
11.
Brachytherapy ; 21(1): 120-127, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34706854

RESUMEN

PURPOSE: This is a multi-institutional report on inter-observer and inter-instrument variation in the calibration of the absorbed dose rate for a planar 32P beta emitting brachytherapy source. Measurement accuracy is essential since the dose profile is steep and the source is used for the treatment of tumors that are located in close proximity to healthy nervous system structures. METHODS AND MATERIALS: An RIC-100 32P source was calibrated by three institutions using their own equipment and following their standard procedures. The first institution calibrated the source with an electron diode and EBT3 film. The second institution used an electron diode. The third institution used HD810 film. Additionally, each institution was asked to calibrate the source using an electron diode and procedure that was shared among all institutions and shipped along with the radiation source. The dose rate was reported in units of cGy*min-1 at a water equivalent depth of 1 mm. RESULTS: Close agreement was observed in the measurements from different users and equipment. The variation across all diode detectors and institutions had a standard deviation of 1.8% and maximum difference of 4.6%. The observed variation among two different diode systems used within the same institution had a mean difference of 1.6% and a maximum variation of 1.8%. The variations among film and diode systems used within the same institution had a mean difference of 2.9% and a maximum variation of 4.3% CONCLUSIONS: The absorbed dose rate measurement protocol of the planar beta-emitting 32P source permits consistent dosimetry across three institutions and five different electron diode and radiochromic film systems. The methodologies presented herein should enable measurement consistency among other clinical users, which will help ensure high quality patient treatments and outcomes analysis.


Asunto(s)
Braquiterapia , Braquiterapia/métodos , Calibración , Dosimetría por Película , Humanos , Radiometría/métodos , Dosificación Radioterapéutica , Agua
12.
J Am Acad Dermatol ; 84(6): 1575-1584, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32827607

RESUMEN

BACKGROUND: Radiation therapy (RT) is a treatment option for select skin cancers. The histologic effects of RT on normal skin or skin cancers are not well characterized. Dermoscopy, high-frequency ultrasonography (HFUS), and reflectance confocal microscopy (RCM) are noninvasive imaging modalities that may help characterize RT response. OBJECTIVES: To describe changes in the tumor and surrounding skin of patients with basal cell carcinoma (BCC) treated with RT. METHODS: The study was conducted between 2014 and 2018. Patients with biopsy-proven BCCs were treated with 42 Gy in 6 fractions using a commercially available brachytherapy device. Dermoscopy, HFUS, and RCM were performed before treatment and at 6 weeks, 3 months, and 12 months after RT. RESULTS: A total of 137 imaging assessments (RCM + dermoscopy + HFUS) were performed in 12 patients. BCC-specific features were present in 81.8%, 91%, and 17% of patients imaged with dermoscopy, RCM, and HFUS at baseline, respectively, before treatment. After treatment, the resolution of these features was noted in 33.4%, 91.7%, and 100% of patients imaged with the respective modalities. No recurrences were seen after a mean of 31.7 months of follow-up. LIMITATIONS: Small sample size and no histopathologic correlation. CONCLUSION: Dermoscopy and HFUS were not as reliable as RCM at characterizing BCC RT response.


Asunto(s)
Carcinoma Basocelular/radioterapia , Fraccionamiento de la Dosis de Radiación , Recurrencia Local de Neoplasia/diagnóstico , Neoplasias Cutáneas/radioterapia , Piel/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Biopsia , Carcinoma Basocelular/diagnóstico , Dermoscopía/estadística & datos numéricos , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Microscopía Confocal/estadística & datos numéricos , Persona de Mediana Edad , Recurrencia Local de Neoplasia/prevención & control , Estudios Prospectivos , Reproducibilidad de los Resultados , Piel/efectos de la radiación , Neoplasias Cutáneas/diagnóstico por imagen , Resultado del Tratamiento , Ultrasonografía/estadística & datos numéricos
13.
Brachytherapy ; 19(6): 762-766, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32952055

RESUMEN

PURPOSE: Safe delivery of brachytherapy and establishing a safety culture are critical in high-quality brachytherapy. The American Brachytherapy Society (ABS) Quality and Safety Committee surveyed members regarding brachytherapy services offered, safety practices during treatment, quality assurance procedures, and needs to develop safety and training materials. METHODS AND MATERIALS: A 22-item survey was sent to ABS membership in early 2019 to physicians, physicists, therapists, nurses, and administrators. Participation was voluntary. Responses were summarized with descriptive statistics and relative frequency distributions. RESULTS: There were 103 unique responses. Approximately one in three was attending physicians and one in three attending physicists. Most were in practice >10 years. A total of 94% and 50% performed gynecologic and prostate brachytherapy, respectively. Ninety-one percent performed two-identification patient verification before treatment. Eighty-six percent performed a time-out. Ninety-five percent had an incident reporting or learning system, but only 71% regularly reviewed incidents. Half reviewed safety practices within the last year. Twenty percent reported they were somewhat or not satisfied with department safety culture, but 92% of respondents were interested in improving safety culture. Most reported time, communication, and staffing as barriers to improving safety. Most respondents desired safety-oriented webinars, self-assessment modules, learning modules, or checklists endorsed by the ABS to improve safety practice. CONCLUSIONS: Most but not all practices use standards and quality assurance procedures in line with society recommendations. There is a need to heighten safety culture at many departments and to shift resources (e.g., time or staffing) to improve safety practice. There is a desire for society guidance to improve brachytherapy safety practices. This is the first survey to assess safety practice patterns among a national sample of radiation oncologists with expertise in brachytherapy.


Asunto(s)
Braquiterapia/estadística & datos numéricos , Neoplasias de los Genitales Femeninos/radioterapia , Seguridad del Paciente , Neoplasias de la Próstata/radioterapia , Garantía de la Calidad de Atención de Salud/estadística & datos numéricos , Oncología por Radiación/organización & administración , Braquiterapia/efectos adversos , Braquiterapia/normas , Lista de Verificación , Comunicación , Femenino , Humanos , Masculino , Cultura Organizacional , Sistemas de Identificación de Pacientes/estadística & datos numéricos , Admisión y Programación de Personal , Mejoramiento de la Calidad , Gestión de Riesgos/estadística & datos numéricos , Encuestas y Cuestionarios , Factores de Tiempo
14.
Brachytherapy ; 19(4): 415-426, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32409128

RESUMEN

PURPOSE: Keratinocyte carcinoma (KC, previously nonmelanoma skin cancer) represents the most common cancer worldwide. While surgical treatment is commonly utilized, various radiation therapy techniques are available including external beam and brachytherapy. As such, the American Brachytherapy Society has created an updated consensus statement regarding the use of brachytherapy in the treatment of KCs. METHODS: Physicians and physicists with expertise in skin cancer and brachytherapy created a consensus statement for appropriate patient selection, data, dosimetry, and utilization of skin brachytherapy and techniques based on a literature search and clinical experience. RESULTS: Guidelines for patient selection, evaluation, and dose/fractionation schedules to optimize outcomes for patients with KC undergoing brachytherapy are presented. Studies of electronic brachytherapy are emerging, although limited long-term data or comparative data are available. Radionuclide-based brachytherapy represents an appropriate option for patients with small KCs with multiple techniques available. CONCLUSIONS: Skin brachytherapy represents a standard of care option for appropriately selected patients with KC. Radionuclide-based brachytherapy represents a well-established technique; however, the current recommendation is that electronic brachytherapy be used for KC on prospective clinical trial or registry because of a paucity of mature data.


Asunto(s)
Braquiterapia/normas , Carcinoma Basocelular/radioterapia , Carcinoma de Células Escamosas/radioterapia , Neoplasias Cutáneas/radioterapia , Braquiterapia/métodos , Consenso , Fraccionamiento de la Dosis de Radiación , Humanos , Selección de Paciente , Radioisótopos/uso terapéutico , Estados Unidos
15.
Brachytherapy ; 18(3): 277-284, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30803923

RESUMEN

BACKGROUND: Intraoperative radiotherapy (IORT) is an effective strategy for the delivery of high doses of radiotherapy to a residual tumor or resection cavity with relative sparing of nearby healthy tissues. This strategy is an important component of the multimodality management of pediatric soft tissue sarcomas, particularly in cases where patients have received prior courses of external beam radiotherapy. PURPOSE: Tumor beds with significant topographic irregularity remain a therapeutic challenge because existing IORT technologies are typically most reliable with flat surfaces. To address this limitation, we have developed a novel strategy to create custom, prefabricated high-dose-rate (HDR)-IORT applicators designed to match the shape of an anticipated surgical cavity. METHODS AND MATERIALS: Silastic applicators are constructed using three-dimensional (3D) printing and are derived from volumetric segmentation of preoperative imaging. RESULTS: HDR preplanning with the applicators improves dosimetric accuracy and minimizes incremental operative time. In this report, we describe the fabrication process for the 3D-printed applicators and detail our experience utilizing this strategy in two pediatric patients who underwent HDR-IORT as part of complex base of skull sarcoma resections. CONCLUSIONS: Early experience suggests that usage of the custom applicators is feasible, versatile for a variety of clinical situations, and enables the uniform delivery of high superficial doses of radiotherapy to irregularly shaped surgical cavities.


Asunto(s)
Braquiterapia/instrumentación , Diseño de Equipo , Neoplasias/terapia , Braquiterapia/métodos , Niño , Femenino , Humanos , Periodo Intraoperatorio , Masculino , Neoplasia Residual , Impresión Tridimensional , Planificación de la Radioterapia Asistida por Computador , Radioterapia Adyuvante
16.
Brachytherapy ; 18(3): 292-298, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30497939

RESUMEN

PURPOSE: Brachytherapy is utilized in the treatment of many different malignancies; although traditionally performed with low-dose-rate or high-dose-rate techniques, more recently, electronic brachytherapy (EB) has emerged as a potential alternative. At this time, there are no evidence-based guidelines to assist clinicians in patient selection for EB and concerns exits regarding differences in dosimetry as compared to traditional brachytherapy techniques. As such, the American Brachytherapy Society appointed a group of physicians and physicists to create a consensus statement regarding the use of EB. METHODS AND MATERIALS: Physicians and physicists with expertise in brachytherapy created a site-directed consensus statement for appropriate patient selection and utilization of EB based on a literature search and clinical experience. RESULTS: EB has been utilized to deliver accelerated partial breast irradiation with, thus far acceptable local control and toxicity rates including a randomized trial that used EB to deliver intraoperative radiotherapy; however, prospective data with large patient numbers and long-term follow up are needed. Increasing numbers of patients have been treated with EB for nonmelanomatous skin cancers; although, preliminary data are promising, there is a lack of data comparing EB to traditional radiotherapy techniques as well as a lack of long-term follow up. For treatment of the vaginal cuff with EB, small retrospective studies have been reported without long-term follow up. CONCLUSIONS: In light of a randomized trial in breast showing higher rates of recurrence and the lack of prospective data with mature follow up with other sites, as well as concerns regarding dosimetry, it is not recommended that EB be utilized for accelerated partial breast irradiation, nonmelanomatous skin cancers, or vaginal cuff brachytherapy outside prospective clinical trials at this time.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Neoplasias de los Genitales Femeninos/radioterapia , Selección de Paciente , Neoplasias Cutáneas/radioterapia , Braquiterapia/efectos adversos , Consenso , Electrónica , Femenino , Humanos , Dosificación Radioterapéutica , Ensayos Clínicos Controlados Aleatorios como Asunto
17.
Brachytherapy ; 17(3): 621-627, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29496425

RESUMEN

PURPOSE: Management of locally recurrent or persistent esophageal cancer (EC) after standard chemoradiation is challenging. This study updates our experience of treating medically inoperable EC patients with endoluminal high-dose-rate brachytherapy (EHDRBT) including the patients treated with a novel multiballoon channel centering esophageal applicator. METHODS AND MATERIALS: Thirty-three consecutive patients with early-stage primary (n = 7), posttreatment persistent (n = 7), and recurrent (n = 19) EC treated with EHDRBT at our institution were included. Median dose and treatment lengths were 14 Gy (range 10-17.5 Gy) and 6 cm (3.5-9.0 cm), respectively. Endoscopy and biopsy were performed 3 months after EHDRBT and then every 3-6 months thereafter. RESULTS: Median followup was 17.4 months (range 5.0-88.3). Grade 1 and 2 toxicities were observed in 13 (44.8%) and 11 (37.9%) patients, respectively. Grade 3 toxicity (tracheoesophageal fistula) was observed in 1 patient who had previously received two courses of external beam radiotherapy as well as a stent insertion. Median overall survival (OS) for entire cohort was 20.9 months, and 1-year OS was 78%. Complete response was achieved in 58.6% of patients with median time to failure and 1-year disease-free survival of 10.3 months (range 5.4-28.2) and 27%, respectively. CONCLUSIONS: For medically inoperable patients with early-stage primary or local posttreatment residual or recurrent EC, EHDRBT is a well-tolerated treatment option with minimal Grade ≥3 toxicity. Brachytherapy in our hands continues to be a safe treatment option. Although 58.6% of patients achieved a complete response and the OS of this cohort is relatively good, long-term local control and cure remains a challenge.


Asunto(s)
Braquiterapia/métodos , Neoplasias Esofágicas/radioterapia , Recurrencia Local de Neoplasia/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Braquiterapia/efectos adversos , Neoplasias Esofágicas/mortalidad , Esófago/patología , Esófago/efectos de la radiación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Traumatismos por Radiación/epidemiología , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Tasa de Supervivencia , Resultado del Tratamiento
18.
Brachytherapy ; 17(2): 251-258, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29241706

RESUMEN

PURPOSE: Rates of rectal toxicity after low-dose-rate (LDR) brachytherapy for prostate cancer are dependent on rectal dose, which is associated with rectal distance from prostate and implanted seeds. Placement of a hydrogel spacer between the prostate and rectum has proven to reduce the volume of the rectum exposed to higher radiation dose levels in the setting of external beam radiotherapy. We present our findings with placing a rectal hydrogel spacer in patients following LDR brachytherapy, and we further assess the impact of this placement on dosimetry and acute rectal toxicity. METHODS AND MATERIALS: Between January 2016 and April 2017, 74 patients had placement of a hydrogel spacer, immediately following a Pd-103 seed-implant procedure. Brachytherapy was delivered as follows: as a monotherapy to 26 (35%) patients; as part of planned combination therapy with external beam radiotherapy to 40 (54%) patients; or as a salvage monotherapy to eight (11%) patients. Postoperative MRI was used to assess separation achieved with rectal spacer. Acute toxicity was assessed retrospectively using Radiation Oncology Therapy Group radiation toxicity grading system. Rectal dosimetry was compared with a consecutive cohort of 136 patients treated with seed implantation at our institution without a spacer, using a 2-tailed paired Student's t test (p < 0.05 for statistical significance). RESULTS: On average, 11.2-mm (SD 3.3) separation was achieved between the prostate and the rectum. The resultant mean rectal volume receiving 100% of prescribed dose (V100%), dose to 1 cc of rectum (D1cc), and dose to 2 cc of rectum (D2cc) were 0 (SD 0.05 cc), 25.3% (SD 12.7), and 20.5% (SD 9.9), respectively. All rectal dosimetric parameters improved significantly for the cohort with spacer placement as compared with the nonspacer cohort. Mean prostate volume, prostate V100 and dose to 90% of gland (D90) were 29.3 cc (SD 12.4), 94.0% (SD 3.81), and 112.4% (SD 12.0), respectively. Urethral D20, D5cc, and D1cc were 122.0% (SD 17.27), 133.8% (SD 22.8), and 144.0% (SD 25.4), respectively. After completing all treatments, at the time of first the followup, 7 patients reported acute rectal toxicity-6 experiencing Grade 1 rectal discomfort and 1 (with preexisting hemorrhoids) experiencing Grade 1 bleeding. CONCLUSIONS: Injection of rectal spacer is feasible in the post-LDR brachytherapy setting and reduces dose to the rectum with minimal toxicity. Prostate and urethral dosimetries do not appear to be affected by the placement of a spacer. Further studies with long-term followup are warranted to assess the impact on reduction of late rectal toxicity.


Asunto(s)
Braquiterapia/métodos , Hidrogeles/administración & dosificación , Paladio/uso terapéutico , Próstata/patología , Neoplasias de la Próstata/radioterapia , Traumatismos por Radiación/prevención & control , Radioisótopos/uso terapéutico , Recto/efectos de la radiación , Anciano , Braquiterapia/efectos adversos , Estudios de Cohortes , Humanos , Imagen por Resonancia Magnética , Masculino , Tamaño de los Órganos , Órganos en Riesgo/efectos de la radiación , Paladio/efectos adversos , Neoplasias de la Próstata/diagnóstico por imagen , Dosis de Radiación , Traumatismos por Radiación/etiología , Radioisótopos/efectos adversos , Dosificación Radioterapéutica , Enfermedades del Recto , Estudios Retrospectivos , Terapia Recuperativa , Uretra/efectos de la radiación
19.
Brachytherapy ; 16(6): 1257-1264, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28827006

RESUMEN

PURPOSE: To present the clinical commissioning of a novel 103Pd directional brachytherapy device (CivaSheet) for intraoperative radiation therapy. METHODS AND MATERIALS: Clinical commissioning for the CivaSheet consisted of establishing: (1) source strength calibration capabilities, (2) experimental verification of TG-43 dosimetry parameters, (3) treatment planning system validation, and (4) departmental practice for dose specification and source ordering. Experimental verification was performed in water with radiochromic film calibrated with a 37 kVp X-ray beam. Percentage difference ([measurements - calculation]/calculation) and distance to agreement (difference between film-to-source distance and distance that minimized the percentage difference) were calculated. Nomogram values (in U/100 Gy) for all configurations (up to 20 × 20 sources) were calculated for source ordering. Clinical commissioning was used on patients enrolled in an ongoing Institutional Review Board-approved protocol. RESULTS: A source calibration procedure was established, and the treatment planning system was commissioned within standard clinical uncertainties. Percentage dose differences (distances to agreement) between measured and calculated doses were 8.6% (-0.12 mm), 0.6% (-0.01 mm), -6.4% (0.22 mm), and -10.0% (0.44 mm) at depths of 2.3, 5.1, 8.0, and 11.1 mm, respectively. All differences were within the experimental uncertainties. Nomogram values depended on sheet size and spatial extent. A value of 2.4U/100 Gy per CivaDot was found to satisfy most cases, ranging from 2.3 to 3.3U/100 Gy. Nomogram results depended on elongation of the treatment area with a higher variation observed for smaller treatment areas. Postimplantation dose evaluation was feasible. CONCLUSIONS: Commissioning and clinical deployment of CivaSheet was feasible using BrachyVision for postoperative dose evaluation. Experimental verification confirmed that the available TG-43 dosimetry parameters are accurate for clinical use.


Asunto(s)
Braquiterapia/instrumentación , Cuidados Intraoperatorios , Paladio , Prótesis e Implantes , Braquiterapia/métodos , Calibración , Dosimetría por Película , Humanos , Radiometría/instrumentación , Dosificación Radioterapéutica
20.
Brachytherapy ; 16(4): 715-727, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28396178

RESUMEN

Magnetic resonance imaging (MRI) is increasingly being used in radiation therapy, and integration of MRI into brachytherapy in particular is becoming more common. We present here a systematic review of the basic physics and technical aspects of incorporating MRI into prostate brachytherapy. Terminology and MRI system components are reviewed along with typical work flows in prostate high-dose-rate and low-dose-rate brachytherapy. In general, the brachytherapy workflow consists of five key components: diagnosis, implantation, treatment planning (scan + plan), implant verification, and delivery. MRI integration is discussed for diagnosis; treatment planning; and MRI-guided brachytherapy implants, in which MRI is used to guide the physical insertion of the brachytherapy applicator or needles. Considerations and challenges for establishing an MRI brachytherapy program are also discussed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA