Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Int Braz J Urol ; 39(2): 209-13, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23683685

RESUMEN

INTRODUCTION: To date, there is a paucity of literature offering practicing urologists a reference for the amount of radiation exposure received while surgically managing urolithiasis. This study examines the cumulative radiation exposure of an urologist over 9 months. MATERIALS AND METHODS: We present a case series of fluoroscopic exposures of an experienced stone surgeon operating at an academic comprehensive stone center between April and December 2011. Radiation exposure measurements were determined by a thermoluminescent dosimeter worn on the outside of the surgeon's thyroid shield. Estimations of radiation exposure (mrem) per month were charted with fluoroscopy times, using scatter plots to estimate Spearman's rank correlation coefficients. RESULTS: The total 9-month radiation exposure was 87 mrems for deep dose equivalent (DDE), 293 mrem for lens dose equivalent (LDE), and 282 mrem for shallow dose equivalent (SDE). Total fluoroscopy time was 252.44 minutes for 64 ureteroscopies (URSs), 29 percutaneous nephrolithtomies (PNLs), 20 cystoscopies with ureteral stent placements, 9 shock wave lithotripsies (SWLs), 9 retrograde pyelograms (RPGs), 2 endoureterotomies, and 1 ureteral balloon dilation. Spearman's rank correlation coefficients examining the association between fluoroscopy time and radiation exposure were not significant for DDE (p = 0.6, Spearman's rho = 0.2), LDE (p = 0.6, Spearman's rho = 0.2), or SDE (p = 0.6, Spearman's rho = 0.2). CONCLUSIONS: Over a 9-month period, total radiation exposures were well below annual accepted limits (DDE 5000 mrem, LDE 15,000 mrem and SDE 50,000 mrem). Although fluoroscopy time did not correlate with radiation exposure, future prospective studies can account for co-variates such as patient obesity and urologist distance from radiation source.


Asunto(s)
Exposición Profesional/análisis , Monitoreo de Radiación/métodos , Urología , Fluoroscopía/efectos adversos , Humanos , Exposición Profesional/normas , Dosis de Radiación , Monitoreo de Radiación/instrumentación , Estándares de Referencia , Valores de Referencia , Estudios Retrospectivos , Medición de Riesgo , Estadísticas no Paramétricas , Factores de Tiempo , Urolitiasis/diagnóstico por imagen , Urolitiasis/cirugía
2.
Int. braz. j. urol ; 39(2): 209-13, Mar-Apr/2013. tab, graf
Artículo en Inglés | LILACS | ID: lil-676254

RESUMEN

Introduction To date, there is a paucity of literature offering practicing urologists a reference for the amount of radiation exposure received while surgically managing urolithiasis. This study examines the cumulative radiation exposure of an urologist over 9 months. Materials and Methods We present a case series of fluoroscopic exposures of an experienced stone surgeon operating at an academic comprehensive stone center between April and December 2011. Radiation exposure measurements were determined by a thermoluminescent dosimeter worn on the outside of the surgeon's thyroid shield. Estimations of radiation exposure (mrem) per month were charted with fluoroscopy times, using scatter plots to estimate Spearman's rank correlation coefficients. Results The total 9-month radiation exposure was 87 mrems for deep dose equivalent (DDE), 293 mrem for lens dose equivalent (LDE), and 282 mrem for shallow dose equivalent (SDE). Total fluoroscopy time was 252.44 minutes for 64 ureteroscopies (URSs), 29 percutaneous nephrolithtomies (PNLs), 20 cystoscopies with ureteral stent placements, 9 shock wave lithotripsies (SWLs), 9 retrograde pyelograms (RPGs), 2 endoureterotomies, and 1 ureteral balloon dilation. Spearman's rank correlation coefficients examining the association between fluoroscopy time and radiation exposure were not significant for DDE (p = 0.6, Spearman's rho = 0.2), LDE (p = 0.6, Spearman's rho = 0.2), or SDE (p = 0.6, Spearman's rho = 0.2). Conclusions Over a 9-month period, total radiation exposures were well below annual accepted limits (DDE 5000 mrem, LDE 15,000 mrem and SDE 50,000 mrem). Although fluoroscopy time did not correlate with radiation exposure, future prospective studies can account for co-variates such as patient obesity and urologist distance from radiation source. .


Asunto(s)
Humanos , Exposición Profesional/análisis , Monitoreo de Radiación/métodos , Urología , Fluoroscopía/efectos adversos , Exposición Profesional/normas , Dosis de Radiación , Estándares de Referencia , Valores de Referencia , Estudios Retrospectivos , Medición de Riesgo , Monitoreo de Radiación/instrumentación , Estadísticas no Paramétricas , Factores de Tiempo , Urolitiasis , Urolitiasis/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA