1.
Heliyon ; 9(2): e13349, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36816240

RESUMEN

A face shield is a secondary personal protective equipment (PPE) for healthcare workers (HCW). Worn with the appropriate face masks/respirators, it provides short term barrier protection against potentially infectious droplet particles. Coronavirus disease 2019 (COVID-19) caused a spike in demand for PPE, leading to a shortage and risking the safety of HCW. Transport restrictions further challenged the existing PPE supply chain which has been reliant on overseas-based manufacturers. Despite the urgency in demand, PPE must be properly tested for functionality and quality. We describe the establishment of local face shields manufacture in Western Australia to ensure adequate PPE for HCW. Ten thousand face shields for general use (standard) and for ear, nose and throat (ENT) specialist use were produced. Materials and design considerations are described, and the face shields were vigorously tested to the relevant Standards to ensure their effectiveness as a protective barrier, including splash and impact resistance. Comparative testing with traditional and other novel face shields was also undertaken. Therapeutic Goods Administration (TGA) licence was obtained to manufacture and supply the face shields as a Class I medical device. The swiftness of process is a credit to collaboration from industry, academia and healthcare.

2.
Bone Joint J ; 103-B(12): 1791-1801, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34474593

RESUMEN

AIMS: The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted total knee arthroplasties (TKAs). METHODS: At our retrieval centre, we measured changes in the wear and deformation of PE inserts using coordinate measuring machines and light microscopy. The amount of cement cover on the backside of tibial trays was quantified as a percentage of the total surface. The study involved data from the explanted fixed-bearing components of four widely used contemporary designs of TKA (Attune, NexGen, Press Fit Condylar (PFC), and Triathlon), revised for any indication, and we compared them with components that used previous generations of PE. Regression modelling was used to identify variables related to the amount of cement cover on the retrieved trays. RESULTS: A total of 114 explanted fixed-bearing TKAs were examined. This included 76 used with contemporary PE inserts which were compared with 15 used with older generation PEs. The Attune and NexGen (central locking) trays were found to have significantly less cement cover than Triathlon and PFC trays (peripheral locking group) (p = 0.001). The median planicity values of the PE inserts used with central locking trays were significantly greater than of those with peripheral locking inserts (205 vs 85 microns; p < 0.001). Attune and NexGen inserts had a characteristic pattern of backside deformation, with the outer edges of the PE deviating inferiorly, leaving the PE margins as the primary areas of articulation. CONCLUSION: Explanted TKAs with central locking mechanisms were significantly more likely to debond from the cement mantle. The PE inserts of these designs showed characteristic patterns of deformation, which appeared to relate to the manufacturing process and may be exacerbated in vivo. This pattern of deformation was associated with PE wear occurring at the outer edges of the articulation, potentially increasing the frictional torque generated at this interface. Cite this article: Bone Joint J 2021;103-B(12):1791-1801.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Cementos para Huesos , Prótesis de la Rodilla , Polietileno , Diseño de Prótesis , Falla de Prótesis/etiología , Adulto , Anciano , Anciano de 80 o más Años , Remoción de Dispositivos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis de Regresión
4.
Mult Scler J Exp Transl Clin ; 4(2): 2055217318781989, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29977589

RESUMEN

PURPOSE: Sexual dysfunction is a common but often overlooked secondary symptom of multiple sclerosis (MS) and can be associated with a decreased health-related quality of life (HRQoL). Natalizumab is a disease-modifying therapy approved for the treatment of relapsing forms of MS. In addition to its efficacy, those using natalizumab have shown improvement in HRQoL parameters, including fatigue and cognition. The idea that improvement in fatigue may also correlate with improvement in sexual dysfunction is the impetus for this study. METHODS: A single-center, open-label, single-arm, 24-week study was performed to evaluate perceived change in sexual dysfunction in MS patients treated with natalizumab. Adults with relapsing MS initiating natalizumab treatment and had a baseline level of sexual dysfunction were enrolled. The primary endpoint was change in the MS Intimacy and Sexuality Questionnaire-19 (MSISQ-19) score from baseline to week 24. Mean age of patients was 41 years, median disease duration was 7 years, and 73% of patients used at least one prior MS disease-modifying therapy. RESULTS: Natalizumab-treated patients experienced improvement in sexual dysfunction within the first 24 weeks of starting therapy, as demonstrated by the primary subscale of the MSISQ-19 questionnaire (-0.6976, p = 0.02). CONCLUSIONS: Given the high prevalence of sexual dysfunction in MS patients and the significant impact it has on HRQoL, more research on this often overlooked symptom of MS could be very informative for patients that are deciding to initiate a new disease modifying therapy.