Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Protein Eng ; 8(12): 1197-1204, 1995 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-8869632

RESUMEN

Optimal sequence threading can be used to recognize members of a library of protein folds which are closely related in 3-D structure to the native fold of an input test sequence, even when the test sequence is not significantly homologous to the sequence of any member of the fold library. The methods provide an alignment between the residues of the test sequence and the residue positions in a template fold. This alignment optimizes a score function, and the predicted fold is the highest scoring member of the library of folds. Most score functions contain a pairwise interaction energy term. This, coupled with the need to introduce gaps into the alignment, means that the optimization problem is NP hard. We report a comparison between two heuristic optimization algorithms used in the literature, double dynamic programming and an iterative algorithm based on the so-called frozen approximation. These are compared in terms of both the ranking of likely folds and the quality of the alignment produced.


Asunto(s)
Algoritmos , Pliegue de Proteína , Proteínas/química , Fructosa-Bifosfato Aldolasa/química , Ficocianina/química , Plastocianina/química , Poliovirus/química , Tripsina/química
2.
Protein Eng ; 7(2): 221-33, 1994 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-8170926

RESUMEN

Different simple solvent models have been implemented in an extended simulated annealing process (ESAP), developed by Higo et al. [(1992) Biopolymers, 32, 33-43] and proven to be able to predict ab initio the conformation of the antigen-combining loop H2 from FAB McPC603. The rationale used here provides a useful new method for testing solvent models in general. The different solvent models comprise a high dielectric constant, a screened coulomb potential, a dummy water model and a statistical continuum treatment of the solvent effect in which the reaction field and the solvent accessible area is accounted for. To assess the effect of the solvent, we tested the ability of simulations to retain the experimental conformation of loop H2. We compared the different structures obtained at the end of the annealing process in terms of root mean square deviation (r.m.s.d.), for both the backbone and for all atoms, root mean square (r.m.s.) fluctuation, solvent accessible surface area (ASA), hydrogen bonding network and phi-psi plot distribution. The relationship between the r.m.s.d. and the internal energy of a structure is also evaluated in terms of precision and another possible method for obtaining the best conformation is discussed. The accuracy of modelling the coarse effect of the solvent and the similarities of the resulting structures with respect to the X-ray reference structure are examined. The possible choice of one of these solvent models in the structure determination of an unknown loop structure is discussed.


Asunto(s)
Sitios de Unión de Anticuerpos/efectos de los fármacos , Simulación por Computador , Fragmentos Fab de Inmunoglobulinas/química , Modelos Moleculares , Conformación Proteica/efectos de los fármacos , Solventes/farmacología , Algoritmos , Fenómenos Químicos , Química Física , Enlace de Hidrógeno , Fragmentos Fab de Inmunoglobulinas/efectos de los fármacos , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA