Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 94(9)2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37737696

RESUMEN

We report on the commissioning of a full aperture backscatter diagnostics station for the kilojoule, nanosecond high repetition rate L4n laser operating at a wavelength of 527 nm at the Extreme Light Infrastructure (ELI) - Beamlines, Dolni Brezany, Czech Republic. Light scattered back from laser-plasma interaction into the cone of the final focusing lens is captured and split into different channels to measure the signatures of laser plasma instabilities from stimulated Brillouin scattering, stimulated Raman scattering, and two plasmon decay with respect to back scattered energy, its spectrum, and its temporal profile. The performance was confirmed in a commissioning experiment with more than 800 shots at laser intensities ranging from 0.5 × 1013 to 1.1 × 1015 W cm-2. These diagnostics are permanently installed at ELI Beamlines, and can be used to understand the details of laser-plasma interactions in experiments with kJ and 527 nm light. The large number of shots that can be collected in an experimental campaign will allow us to study the details of the laser-plasma interaction with a high level of confidence.

2.
Rev Sci Instrum ; 92(6): 063504, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243562

RESUMEN

L3-HAPLS (High-repetition-rate Advanced Petawatt Laser System) at ELI (Extreme Light Infrastructure) Beamlines currently delivers 0.45 PW pulses (12 J in 27 fs) at 3.3 Hz repetition rate. A fresh target surface for every shot was placed at the laser focus using an in-house tape target system designed to withstand large laser intensities and energies. It has been tested for different material thicknesses (25 and 7.6 µm), while L3-HAPLS delivered laser shots for energies ranging from 1 to 12 J. A technical description of the tape target system is given. The device can be used in diverse geometries needed for laser-matter interaction studies by providing an ≈300° free angle of view on the target in the equatorial plane. We show experimental data demonstrating the shot-to-shot stability of the device. An x-ray crystal spherical spectrometer was set up to measure the Kα yield stability, while a GHz H-field probe was used to check the shot-to-shot electromagnetic pulse generation. Finally, we discuss short and mid-term future improvements of the tape target system for efficient user operation.

3.
Rev Sci Instrum ; 89(10): 10F104, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30399942

RESUMEN

We describe a setup for performing inelastic X-ray scattering and X-ray diffraction measurements at the Matter in Extreme Conditions (MEC) endstation of the Linac Coherent Light Source. This technique is capable of performing high-, meV-resolution measurements of dynamic ion features in both crystalline and non-crystalline materials. A four-bounce silicon (533) monochromator was used in conjunction with three silicon (533) diced crystal analyzers to provide an energy resolution of ∼50 meV over a range of ∼500 meV in single shot measurements. In addition to the instrument resolution function, we demonstrate the measurement of longitudinal acoustic phonon modes in polycrystalline diamond. Furthermore, this setup may be combined with the high intensity laser drivers available at MEC to create warm dense matter and subsequently measure ion acoustic modes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...