Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 31(Pt 4): 888-895, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38838165

RESUMEN

Understanding the correlation between chemical and microstructural properties is critical for unraveling the fundamental relationship between materials chemistry and physical structures that can benefit materials science and engineering. Here, we demonstrate novel in situ correlative imaging of the X-ray Compton scattering computed tomography (XCS-CT) technique for studying this fundamental relationship. XCS-CT can image light elements that do not usually exhibit strong signals using other X-ray characterization techniques. This paper describes the XCS-CT setup and data analysis method for calculating the valence electron momentum density and lithium-ion concentration, and provides two examples of spatially and temporally resolved chemical properties inside batteries in 3D. XCS-CT was applied to study two types of rechargeable lithium batteries in standard coin cell casings: (1) a lithium-ion battery containing a cathode of bespoke microstructure and liquid electrolyte, and (2) a solid-state battery containing a solid-polymer electrolyte. The XCS-CT technique is beneficial to a wide variety of materials and systems to map chemical composition changes in 3D structures.

2.
J Synchrotron Radiat ; 29(Pt 4): 1043-1053, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35787572

RESUMEN

Three-dimensional X-ray diffraction (3DXRD) is shown to be feasible at the I12 Joint Engineering, Environmental and Processing (JEEP) beamline of Diamond Light Source. As a demonstration, a microstructually simple low-carbon ferritic steel was studied in a highly textured and annealed state. A processing pipeline suited to this beamline was created, using software already established in the 3DXRD user community, enabling grain centre-of-mass positions, orientations and strain tensor elements to be determined. Orientations, with texture measurements independently validated from electron backscatter diffraction (EBSD) data, possessed a ∼0.1° uncertainty, comparable with other 3DXRD instruments. The spatial resolution was limited by the far-field detector pixel size; the average of the grain centre of mass position errors was determined as ±âˆ¼80 µm. An average per-grain error of ∼1 × 10-3 for the elastic strains was also measured; this could be reduced in future experiments by improving sample preparation, geometry calibration, data collection and analysis techniques. Application of 3DXRD onto I12 shows great potential, where its implementation is highly desirable due to the flexible, open architecture of the beamline. User-owned or designed sample environments can be used, thus 3DXRD could be applied to previously unexplored scientific areas.

3.
Adv Sci (Weinh) ; 9(16): e2105723, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35404540

RESUMEN

The performance of Li+ ion batteries (LIBs) is hindered by steep Li+ ion concentration gradients in the electrodes. Although thick electrodes (≥300 µm) have the potential for reducing the proportion of inactive components inside LIBs and increasing battery energy density, the Li+ ion concentration gradient problem is exacerbated. Most understanding of Li+ ion diffusion in the electrodes is based on computational modeling because of the low atomic number (Z) of Li. There are few experimental methods to visualize Li+ ion concentration distribution of the electrode within a battery of typical configurations, for example, coin cells with stainless steel casing. Here, for the first time, an interrupted in situ correlative imaging technique is developed, combining novel, full-field X-ray Compton scattering imaging with X-ray computed tomography that allows 3D pixel-by-pixel mapping of both Li+ stoichiometry and electrode microstructure of a LiNi0.8 Mn0.1 Co0.1 O2 cathode to correlate the chemical and physical properties of the electrode inside a working coin cell battery. An electrode microstructure containing vertically oriented pore arrays and a density gradient is fabricated. It is shown how the designed electrode microstructure improves Li+ ion diffusivity, homogenizes Li+ ion concentration through the ultra-thick electrode (1 mm), and improves utilization of electrode active materials.

4.
Sci Adv ; 7(52): eabj0960, 2021 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-34936457

RESUMEN

Experimental and field studies reported a significant discrepancy between the cleanup and contamination time scales, while its cause is not yet addressed. Using high-resolution fast synchrotron x-ray computed tomography, we characterized the solute transport in a fully saturated sand packing for both contamination and cleanup processes at similar hydrodynamic conditions. The discrepancy in the time scales has been demonstrated by the nonuniqueness of hydrodynamic dispersion coefficient versus injection rate (Péclet number). Observations show that in the mixed advection-diffusion regime, the hydrodynamic dispersion coefficient of cleanup is significantly larger than that of the contamination process. This nonuniqueness has been attributed to the concentration-dependent diffusion coefficient during the cocurrent and countercurrent advection and diffusion, present in contamination and cleanup processes. The new findings enhance our fundamental understanding of transport processes and improve our capability to estimate the transport time scales of chemicals or pollution in geological and engineering systems.

5.
Opt Express ; 29(12): 17849-17874, 2021 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-34154059

RESUMEN

Parallel-beam tomography systems at synchrotron facilities have limited field of view (FOV) determined by the available beam size and detector system coverage. Scanning the full size of samples bigger than the FOV requires various data acquisition schemes such as grid scan, 360-degree scan with offset center-of-rotation (COR), helical scan, or combinations of these schemes. Though straightforward to implement, these scanning techniques have not often been used due to the lack of software and methods to process such types of data in an easy and automated fashion. The ease of use and automation is critical at synchrotron facilities where using visual inspection in data processing steps such as image stitching, COR determination, or helical data conversion is impractical due to the large size of datasets. Here, we provide methods and their implementations in a Python package, named Algotom, for not only processing such data types but also with the highest quality possible. The efficiency and ease of use of these tools can help to extend applications of parallel-beam tomography systems.

6.
Elife ; 102021 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-33648628

RESUMEN

Numerous aspects of early hominin biology remain debated or simply unknown. However, recent developments in high-resolution imaging techniques have opened new avenues in the field of paleoanthropology. More specifically, X-ray synchrotron-based analytical imaging techniques have the potential to provide crucial details on the ontogeny, physiology, biomechanics, and biological identity of fossil specimens. Here we present preliminary results of our X-ray synchrotron-based investigation of the skull of the 3.67-million-year-old Australopithecus specimen StW 573 ('Little Foot') at the I12 beamline of the Diamond Light Source (United Kingdom). Besides showing fine details of the enamel (i.e., hypoplasias) and cementum (i.e., incremental lines), as well as of the cranial bone microarchitecture (e.g., diploic channels), our synchrotron-based investigation reveals for the first time the 3D spatial organization of the Haversian systems in the mandibular symphysis of an early hominin.


Asunto(s)
Fósiles/anatomía & histología , Hominidae/anatomía & histología , Cráneo/anatomía & histología , Animales , Fósiles/diagnóstico por imagen , Osteón/anatomía & histología , Mandíbula/anatomía & histología , Cráneo/diagnóstico por imagen , Sincrotrones , Tomografía Computarizada por Rayos X/métodos , Diente/anatomía & histología , Diente/diagnóstico por imagen
7.
J Appl Crystallogr ; 53(Pt 6): 1434-1443, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33304221

RESUMEN

An experimental technique is described for the collection of time-resolved X-ray diffraction information from a complete commercial battery cell during discharging or charging cycles. The technique uses an 80 × 80 pixel 2D energy-discriminating detector in a pinhole camera geometry which can be used with a polychromatic X-ray source. The concept was proved in a synchrotron X-ray study of commercial alkaline Zn-MnO2 AA size cells. Importantly, no modification of the cell was required. The technique enabled spatial and temporal changes to be observed with a time resolution of 20 min (5 min of data collection with a 15 min wait between scans). Chemical changes in the cell determined from diffraction information were correlated with complementary X-ray tomography scans performed on similar cells from the same batch. The clearest results were for the spatial and temporal changes in the Zn anode. Spatially, there was a sequential transformation of Zn to ZnO in the direction from the separator towards the current collector. Temporally, it was possible to track the transformation of Zn to ZnO during the discharge and follow the corresponding changes in the cathode.

8.
HardwareX ; 7: e00104, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35495201

RESUMEN

As a part of a research into new techniques for purifying recycled aluminium alloys, a novel electromagnetic apparatus had been developed for investigating in real-time the separation mechanisms of detrimental inclusions in aluminium alloy melts under alternating magnetic fields. The magnetic coil was designed based on the Helmholtz coil design. A viewing gap was designed for in-situ imaging studies using synchrotron X-rays. The gap was designed to maintain a uniform magnetic field in the central region where a sample is positioned. The current setup for the magnetic coil pair is able to produce a peak magnetic flux density of ~10 mT at a frequency of 25 kHz. A separate electrical resistance furnace, designed to concentrically fit within the magnetic coils, was used to control the heating (up to ~850°C) and cooling of the samples. After a series of systematic tests and commissioning, the apparatus was used in a number of in-situ and ex-situ experiments.

9.
Materials (Basel) ; 13(1)2019 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-31861786

RESUMEN

Quantitative understanding of the interactions of ultrasonic waves with liquid and solidifying metals is essential for developing optimal processing strategies for ultrasound processing of metal alloys in the solidification processes. In this research, we used the synchrotron X-ray high-speed imaging facility at Beamline I12 of the Diamond Light Source, UK to study the dynamics of ultrasonic bubbles in a liquid Sn-30wt%Cu alloy. A new method based on the X-ray attenuation for a white X-ray beam was developed to extract quantitative information about the bubble clouds in the chaotic and quasi-static cavitation regions. Statistical analyses were made on the bubble size distribution, and velocity distribution. Such rich statistical data provide more quantitative information about the characteristics of ultrasonic bubble clouds and cavitation in opaque, high-temperature liquid metals.

10.
Nat Commun ; 9(1): 5414, 2018 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-30575762

RESUMEN

Internal flow behaviour during melt-pool-based metal manufacturing remains unclear and hinders progression to process optimisation. In this contribution, we present direct time-resolved imaging of melt pool flow dynamics from a high-energy synchrotron radiation experiment. We track internal flow streams during arc welding of steel and measure instantaneous flow velocities ranging from 0.1 m s-1 to 0.5 m s-1. When the temperature-dependent surface tension coefficient is negative, bulk turbulence is the main flow mechanism and the critical velocity for surface turbulence is below the limits identified in previous theoretical studies. When the alloy exhibits a positive temperature-dependent surface tension coefficient, surface turbulence occurs and derisory oxides can be entrapped within the subsequent solid as result of higher flow velocities. The widely used arc welding and the emerging arc additive manufacturing routes can be optimised by controlling internal melt flow through adjusting surface active elements.

11.
J Synchrotron Radiat ; 25(Pt 3): 801-807, 2018 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-29714191

RESUMEN

The high flux of the white X-ray beams from third-generation synchrotron light sources can significantly benefit the development of high-speed X-ray imaging, but can also bring technical challenges to existing X-ray imaging systems. One prevalent problem is that the image quality deteriorates because of dust particles accumulating on the scintillator screen during exposure to intense X-ray radiation. Here, this problem has been solved by embedding the scintillator in a flowing inert-gas environment. It is also shown that the detector maintains the quality of the captured images even after days of X-ray exposure. This modification is cost-efficient and easy to implement. Representative examples of applications using the X-ray imaging system are also provided, including fast tomography and multimodal phase-contrast imaging for biomedical and geological samples.

12.
Data Brief ; 17: 837-841, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29527546

RESUMEN

The data presented in this article are related to the paper entitled 'Ultrafast synchrotron X-ray imaging studies of microstructure fragmentation in solidification under ultrasound' [Wang et al., Acta Mater. 144 (2018) 505-515]. This data article provides further supporting information and analytical methods, including the data from both experimental and numerical simulation, as well as the Matlab code for processing the X-ray images. Six videos constructed from the processed synchrotron X-ray images are also provided.

13.
Ultrason Sonochem ; 39: 66-76, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28732991

RESUMEN

The cavitation-induced fragmentation of primary crystals formed in Al alloys were investigated for the first time by high-speed imaging using a novel experimental approach. Three representative primary crystal types, Al3Ti, Si and Al3V with different morphologies and mechanical properties were first extracted by deep etching of the corresponding Al alloys and then subjected to ultrasonic cavitation processing in distilled water. The dynamic interaction between the cavitation bubbles and primary crystals was imaged in situ and in real time. Based on the recorded image sequences, the fragmentation mechanisms of primary crystals were studied. It was found that there are three major mechanisms by which the primary crystals were fragmented by cavitation bubbles. The first one was a slow process via fatigue-type failure. A cyclic pressure exerted by stationary pulsating bubbles caused the propagation of a crack pre-existing in the primary crystal to a critical length which led to fragmentation. The second mechanism was a sudden process due to the collapse of bubbles in a passing cavitation cloud. The pressure produced upon the collapse of the cloud promoted rapid monotonic crack growth and fast fracture in the primary crystals. The third observed mechanism was normal bending fracture as a result of the high pressure arising from the collapse of a bubble cloud and the crack formation at the branch connection points of dendritic primary crystals. The fragmentation of dendrite branches due to the interaction between two freely moving dendritic primary crystals was also observed. A simplified fracture analysis of the observed phenomena was performed. The specific fragmentation mechanism for the primary crystals depended on their morphology and mechanical properties.

14.
J Synchrotron Radiat ; 22(3): 828-38, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25931103

RESUMEN

I12 is the Joint Engineering, Environmental and Processing (JEEP) beamline, constructed during Phase II of the Diamond Light Source. I12 is located on a short (5 m) straight section of the Diamond storage ring and uses a 4.2 T superconducting wiggler to provide polychromatic and monochromatic X-rays in the energy range 50-150 keV. The beam energy enables good penetration through large or dense samples, combined with a large beam size (1 mrad horizontally × 0.3 mrad vertically). The beam characteristics permit the study of materials and processes inside environmental chambers without unacceptable attenuation of the beam and without the need to use sample sizes which are atypically small for the process under study. X-ray techniques available to users are radiography, tomography, energy-dispersive diffraction, monochromatic and white-beam two-dimensional diffraction/scattering and small-angle X-ray scattering. Since commencing operations in November 2009, I12 has established a broad user community in materials science and processing, chemical processing, biomedical engineering, civil engineering, environmental science, palaeontology and physics.


Asunto(s)
Cristalografía por Rayos X/instrumentación , Rayos Láser , Aceleradores de Partículas/instrumentación , Espectrometría por Rayos X/instrumentación , Rayos X , Transferencia de Energía , Diseño de Equipo , Análisis de Falla de Equipo , Iluminación/instrumentación , Reino Unido
15.
Proc Math Phys Eng Sci ; 470(2165): 20130629, 2014 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-24808753

RESUMEN

In recent times, there has been a drive to develop non-destructive X-ray imaging techniques that provide chemical or physical insight. To date, these methods have generally been limited; either requiring raster scanning of pencil beams, using narrow bandwidth radiation and/or limited to small samples. We have developed a novel full-field radiographic imaging technique that enables the entire physio-chemical state of an object to be imaged in a single snapshot. The method is sensitive to emitted and scattered radiation, using a spectral imaging detector and polychromatic hard X-radiation, making it particularly useful for studying large dense samples for materials science and engineering applications. The method and its extension to three-dimensional imaging is validated with a series of test objects and demonstrated to directly image the crystallographic preferred orientation and formed precipitates across an aluminium alloy friction stir weld section.

16.
J Appl Crystallogr ; 46(Pt 5): 1249-1260, 2013 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-24068840

RESUMEN

A complete calibration method to characterize a static planar two-dimensional detector for use in X-ray diffraction at an arbitrary wavelength is described. This method is based upon geometry describing the point of intersection between a cone's axis and its elliptical conic section. This point of intersection is neither the ellipse centre nor one of the ellipse focal points, but some other point which lies in between. The presented solution is closed form, algebraic and non-iterative in its application, and gives values for the X-ray beam energy, the sample-to-detector distance, the location of the beam centre on the detector surface and the detector tilt relative to the incident beam. Previous techniques have tended to require prior knowledge of either the X-ray beam energy or the sample-to-detector distance, whilst other techniques have been iterative. The new calibration procedure is performed by collecting diffraction data, in the form of diffraction rings from a powder standard, at known displacements of the detector along the beam path.

17.
Acta Crystallogr D Biol Crystallogr ; 69(Pt 7): 1252-9, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23793151

RESUMEN

The focus in macromolecular crystallography is moving towards even more challenging target proteins that often crystallize on much smaller scales and are frequently mounted in opaque or highly refractive materials. It is therefore essential that X-ray beamline technology develops in parallel to accommodate such difficult samples. In this paper, the use of X-ray microradiography and microtomography is reported as a tool for crystal visualization, location and characterization on the macromolecular crystallography beamlines at the Diamond Light Source. The technique is particularly useful for microcrystals and for crystals mounted in opaque materials such as lipid cubic phase. X-ray diffraction raster scanning can be used in combination with radiography to allow informed decision-making at the beamline prior to diffraction data collection. It is demonstrated that the X-ray dose required for a full tomography measurement is similar to that for a diffraction grid-scan, but for sample location and shape estimation alone just a few radiographic projections may be required.


Asunto(s)
Bacteriorodopsinas/química , Procesamiento de Imagen Asistido por Computador , Lípidos/química , Microrradiografía , Nitrito Reductasas/química , Receptor de Adenosina A2A/química , Tomografía Computarizada por Rayos X , Algoritmos , Cristalografía por Rayos X , Interpretación Estadística de Datos , Procesamiento Automatizado de Datos , Humanos , Programas Informáticos
18.
J Synchrotron Radiat ; 20(Pt 2): 316-23, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23412489

RESUMEN

The present investigation establishes the feasibility of using synchrotron-generated X-ray beams for time-resolved in situ imaging and diffraction of the interior components of an internal combustion engine during its operation. The demonstration experiment was carried out on beamline I12 (JEEP) at Diamond Light Source, UK. The external hutch of the JEEP instrument is a large-scale engineering test bed for complex in situ processing and simulation experiments. The hutch incorporates a large capacity translation and rotation table and a selection of detectors for monochromatic and white-beam diffraction and imaging. These capabilities were used to record X-ray movies of a motorcycle internal combustion engine running at 1850 r.p.m. and to measure strain inside the connecting rod via stroboscopic X-ray diffraction measurement. The high penetrating ability and high flux of the X-ray beam at JEEP allowed the observation of inlet and outlet valve motion, as well as that of the piston, connecting rod and the timing chain within the engine. Finally, the dynamic internal strain within the moving connecting rod was evaluated with an accuracy of ~50 × 10(-6).

19.
J Synchrotron Radiat ; 15(Pt 6): 584-92, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18955764

RESUMEN

Finite-element analysis is frequently used by engineers at synchrotron beamlines to calculate the elastic deformation of a single crystal undergoing mechanical bending or thermal load. ANSYS Workbench software is widely used for such simulations. However, although ANSYS Workbench software provides useful information on the displacements, strains and stresses within the crystal, it does not yield the local reciprocal lattice vectors that would be required for X-ray diffraction calculations. To bridge this gap, a method based on the shape functions and interpolation procedures of the software itself has been developed. An application to the double-crystal bent Laue monochromator being designed for the I12 (JEEP) wiggler beamline at the Diamond Light Source is presented.


Asunto(s)
Algoritmos , Cristalografía por Rayos X/métodos , Filtración/métodos , Análisis de Elementos Finitos , Modelos Químicos , Refractometría/métodos , Simulación por Computador , Dispersión de Radiación
20.
Med Eng Phys ; 29(10): 1132-41, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17137823

RESUMEN

Coronary stents are small scaffolds routinely implanted during angioplasty procedures to re-open coronary arteries which have become narrowed by an atherosclerotic plaque. Despite the advent of drug-eluting stents to reduce restenosis (re-narrowing) after the procedure, complications still arise and mechanical factors may be partly the cause. Stents are being used in increasingly complex cases, so new forms of pre-clinical testing may be helpful in evaluating stent designs and deployment techniques. With this in mind, an in vitro experiment was conducted to evaluate the use of X-ray micro-tomography to image stents at various stages of deployment. A stent was deployed in an artificial artery while using a synchrotron X-ray source to obtain the tomography scans. A volume element (voxel) size of 5.3 microm was achieved, with a vertical field of view of 4.5mm. The imaging of the stent and artificial artery materials was better than expected, despite some attenuation artifacts and the high monochromatic beam energy used (25 keV). Experimental problems are discussed, together with recommendations for improving the technique. It is intended that this technique will be of interest to engineers and clinicians as a pre-clinical test.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagenología Tridimensional , Interpretación de Imagen Radiográfica Asistida por Computador , Stents , Tomografía Computarizada por Rayos X/métodos , Arterias/patología , Implantación de Prótesis Vascular/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/etiología , Humanos , Metales , Microscopía de Contraste de Fase , Modelos Cardiovasculares , Diseño de Prótesis , Sincrotrones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...