Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38873698

RESUMEN

Image-guided core needle biopsies (IG-CNB) represent a minimally invasive approach for obtaining tissue in patients with lymphadenopathy and suspected lymphoma. Despite their utility, diagnostic challenges persist, with lower efficacy compared with excisional biopsies. Our study aimed to evaluate the potential utility of incorporation of flow cytometry (FC) alongside immunohistochemistry (IHC) when performing IG-CNB for suspected lymphoproliferative diseases. Analyzing 170 consecutive cases, guided by ultrasound (n = 94) or computer tomography (n = 76), we employed a diagnostic algorithm, already established in our laboratory practice, utilizing three antibody cocktail-equipped tubes tailored for defining lymphomas, particularly those of B-cell origin. FC expedited the diagnostic process, yielding presumptive results in 87.6% of cases within 48 h, with a positive predictive value of 98%. Addition of FC to routine IHC enhanced the diagnostic rate from 91.2% to 95.3%, reducing IG-CNB failure rate by 45%, from 8.8% to 4.7%. This enhancement was particularly notable for deep-seated sites and in the setting of suspected disease recurrences. Consequently, FC emerges as a valuable adjunctive tool, allowing for the improvement of diagnostic performance, with a particular focus on the ability to quantify the expression of surface markers for targeted therapies, and holding the potential to diminish the necessity for repeat excisional biopsies subsequent to IG-CNB procedures.

2.
Radiol Med ; 129(5): 807-816, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38512624

RESUMEN

OBJECTIVES: Combined treatment of ablation and chemoembolization for hepatocellular carcinoma represents a promising therapy to increase treatment efficacy and improve patient survival. The "hug sign" is a recently introduced radiological sign consisting in deposition of beads/contrast agent during transarterial chemoembolization in the hyperemic area surrounding the post-ablation volume, seen during intraprocedural unenhanced cone-beam CT, that may indicate intraprocedural success. Aim of our retrospective study was to analyze the usefulness of the "hug sign" at the intraprocedural unenhanced cone-beam CT as an early predictor of response to combined treatment, based on the hug sign angle. MATERIALS AND METHODS: Between January 2017 and September 2021 all patients with hepatocellular carcinoma which underwent a combined treatment of thermal ablation followed by chemoembolization were enrolled. All treated patients underwent immediate post-procedural unenhanced cone-beam CT to evaluate the deposition of contrast agent, lipiodol or radiopaque beads and to assess the percentage of coverage of the ablated area with the contrast agent (hug sign angle). Patients with missing pre-procedural, intra-procedural and/or post-procedural data/imaging, or with poor-quality post-procedural cone-beam CT images were excluded. RESULTS: 128 patients (mean age, 69.3 years ± 1.1 [standard deviation]; 87 men) were evaluated. Our study evidenced that 84.4% (81/85) of patients with a hug sign angle of 360° had no residual tumor at the first 1-/3-months follow-up examination. A hug sign angle of 360° also showed to be an independent protective factor against residual tumor at multivariate analysis. CONCLUSION: Unenhanced cone-beam CT performed at the end of a combined treatment with ablation plus chemoembolization can effectively predict an early treatment response on radiological images, when a hug sign angle of 360° was detected.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Tomografía Computarizada de Haz Cónico , Medios de Contraste , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Tomografía Computarizada de Haz Cónico/métodos , Masculino , Femenino , Estudios Retrospectivos , Anciano , Quimioembolización Terapéutica/métodos , Persona de Mediana Edad , Resultado del Tratamiento , Terapia Combinada , Valor Predictivo de las Pruebas , Aceite Etiodizado/administración & dosificación
3.
Cancers (Basel) ; 15(15)2023 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-37568804

RESUMEN

Hepatocellular carcinoma represents an important cause of death worldwide. Early-stage hepatocellular carcinoma patients not suitable for surgery can be treated with a variety of minimally invasive locoregional interventional oncology techniques. Various guidelines in different countries address the treatment of hepatocellular carcinoma, but the actual treatment is usually discussed by a multidisciplinary tumor board in a personalized manner, leading to potential treatment differences based on Western and Eastern perspectives. The aim of this paper is to integrate literature evidence with the eminent experiences collected during a focused session at the Mediterranean Interventional Oncology (MIO) Live Congress 2023.

4.
J Clin Med ; 12(14)2023 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-37510894

RESUMEN

Endovascular management of abdominal wall hematomas (AWHs) is now the primary treatment option in hemodynamically stable patients, and it is often preferred to surgical interventions. The purpose of this multicentric study was to assess the safety, technical, and clinical success of percutaneous transarterial embolization (PTAE) of spontaneous AWHs to evaluate the efficacy of blind or empiric embolization compared to targeted embolization and to compare the outcome of the endovascular treatment approach in patients affected by COVID-19 and non-COVID-19 patients. We retrospectively enrolled 112 patients with spontaneous AWHs who underwent PTAE, focusing on signs of bleeding at pre-procedural CTA and DSA. Patients were separated into two groups depending on whether a blind or targeted embolization approach was used. We also divided patients into COVID-19 and non-COVID-19 groups. The mean age of the study population was 68.6 ± 15.8 years. CTA and DSA revealed signs of active bleeding in 99 and 88 patients, respectively. In 21 patients, blind embolization was performed. The overall technical success rate was 99%. Clinical success was obtained in 96 patients (86%), while 16 (14%) re-bled within 96 h. One patient reported a major peri-procedural complication. The comparison between blind and targeted embolization approaches showed no statistically significant differences in the characteristics of groups and technical and clinical success rates. No significant differences were found in the procedural outcome between COVID-19 and non-COVID-19 groups. Our study confirmed that PTAE is effective for treating spontaneous AWHs, even in COVID-19 patients. It suggests that the efficacy and safety of blind embolization are comparable to targeted embolization.

6.
Cardiovasc Intervent Radiol ; 46(7): 827-834, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37225968

RESUMEN

AIM: The aim of this prospective, multicentre, observational study was to compare the efficacy and safety of balloon-based and non-balloon-based vascular closure devices (VCDs). MATERIALS AND METHODS: From March 2021 to May 2022, 2373 participants from 10 different centres were enrolled. Among them, 1672 patients with 5-7 Fr accesses were selected. Successful haemostasis, failure and safety were evaluated. Successful haemostasis was defined as the possibility to obtain complete haemostasis with the use of VCDs, without any complication. Failure management was defined as the need of manual compression. Safety was defined as the rate of complications. Cases of haematomas/pseudoaneurysms (PSA) and artero-venous fistula (AVF) were collected. RESULTS: VCDs mechanism of action is statistically significant associated with the outcome. Non-balloon-based VCDs demonstrated a statistically significant better outcome: successful haemostasis was obtained in 96.5% vs. 85.9%, of cases when compared to balloon occluders (p < 0.001). The incidence of AVF was statistically more frequent using non-balloon occluders devices (1.57% vs 0%, p: 0.007). No significant statistical difference was found in comparing haematoma and PSA occurrence. Thrombocytopenia, coagulation deficit, BMI, diabetes mellitus and anti-coagulation were demonstrated to be independent predictors of failure management. CONCLUSION: Our study suggests a better outcome with the same complication rate, except that for AVF incidence for non-balloon collagen plug device if compared to balloon occluders vascular closure devices.


Asunto(s)
Punciones , Dispositivos de Cierre Vascular , Humanos , Estudios Prospectivos , Hematoma , Técnicas Hemostáticas/efectos adversos , Arteria Femoral , Resultado del Tratamiento
7.
Int J Mol Sci ; 24(8)2023 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-37108507

RESUMEN

Personalized cancer treatments help to deliver tailored and biologically driven therapies for cancer patients. Interventional oncology techniques are able to treat malignancies in a locoregional fashion, with a variety of mechanisms of action leading to tumor necrosis. Tumor destruction determines a great availability of tumor antigens that can be recognized by the immune system, potentially triggering an immune response. The advent of immunotherapy in cancer care, with the introduction of specific immune checkpoint inhibitors, has led to the investigation of the synergy of these drugs when used in combination with interventional oncology treatments. The aim of this paper is to review the most recent advances in the field of interventional oncology locoregional treatments and their interactions with immunotherapy.


Asunto(s)
Neoplasias , Humanos , Neoplasias/tratamiento farmacológico , Oncología Médica/métodos , Inmunoterapia/métodos
8.
Life (Basel) ; 13(3)2023 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-36983990

RESUMEN

Pancreatic ductal adenocarcinoma (PDAC) is a lethal disease; patients' long-term survival is strictly linked to the surgical resection of the tumor but only a minority of patients (2-3%) have a resectable disease at diagnosis. In patients with surgically unresectable disease, interventional radiology is taking on an increasing role in treatment with the application of loco-regional percutaneous therapies. The primary purposes of this narrative review are to analyze the safety and efficacy of ablative techniques in the management of borderline resectable and locally advanced diseases and to underline the role of the interventional radiologist in the management of patients with distant metastases. The secondary purpose is to focus on the synergy between immunotherapy and ablative therapies.

11.
Br J Radiol ; : 20220236, 2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-36318237

RESUMEN

Pain is the most common and fearsome symptom in cancer patients, particularly in the advanced stage of disease. In cancer pain management, the first option is represented by analgesic drugs, whereas surgery is rarely used. Prior to considering surgical intervention, less invasive locoregional procedures are available from the wide pain management arsenal. In this review article, comprehensive information about the most commonly used locoregional options available for treating cancer pain focusing on interventional radiology (neurolysis, augmentation techniques, and embolization) and interventional radiotherapy were provided, also highlighting the potential ways to increase the effectiveness of treatments.

12.
Cardiovasc Intervent Radiol ; 45(2): 249-254, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35028722

RESUMEN

PURPOSE: The aim was to compare a protocol of uterine artery embolization (UAE) consisting in three digital subtraction angiographies (DSAs)-Group A, with a protocol based on a single DSA-Group B. MATERIALS AND METHODS: This is a single-center prospective randomized study enrolling 20 women (mean age 41 years, range 22-55 years) with uterine fibroids treated with UAE, from January 2015 to February 2016. All UAEs were performed by two interventional radiologists using the same angiography machine. Protocol of Group A consisted in three DSA runs (non-selective pelvic view and selective uterine views before and after embolization). Protocol of Group B consisted in 1 DSA run: selective UA angiography before embolization. (Fluoroscopic roadmap was used for UA catheterization; fluoroscopy storage was used as control after embolization.) Each patient was randomized to receive Protocol A in one pelvic side and Protocol B on the other. RESULTS: All patients received bilateral UAE. Mean fluoroscopy time for UA catheterization was 11.3 ± 3.7 s. (Protocol A) and 9.93 ± 2.99 s. (Protocol B) (p = 0.19). Fluoroscopy dose for catheterization and embolization was not different between both protocols (p = 0.14). Identification of the UA origin score was similar in both protocols (median error = 0, p = 0.79). Mean dose area product (DAP) was 40859 mGy/cm2 (Protocol A) and 28839 mGy/cm2 (Protocol B) (p = 0.003). Mean effective dose (ED) decreased from Protocol A (14.6 mSv) to Protocol B (9.2 mSv; - 37%). Mean absorbed dose (AD) to ovaries and uterus, respectively, decreased of 53% and 55% from Protocol A to Protocol B. CONCLUSION: Reducing the number of DSA runs from 3 to 1 during UAE allows at least a 30% reduction on radiation exposure, without compromising technical outcomes.


Asunto(s)
Exposición a la Radiación , Embolización de la Arteria Uterina , Adulto , Angiografía de Substracción Digital , Femenino , Fluoroscopía , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Ensayos Clínicos Controlados Aleatorios como Asunto , Adulto Joven
13.
J Ultrasound ; 25(1): 73-78, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33565051

RESUMEN

AIMS: To evaluate the echogenicity of a commercially available needle, modified on the tip, by comparing two groups of patients undergoing to percutaneous biliary drainage. METHODS: In this retrospective analysis 16 percutaneous transhepatic biliary drainage (PTBD) procedures performed on 16 oncologic patients were evaluated. Patients were randomly divided into two groups of eight subjects each; in the first group, a standard needle was adopted (group A); in the second group, the needle was manually modified to create a rough surface (group B), by scrubbing the tip with an 11 scalpel blade for 150 s all around its surface. To objectively quantify US needle tip visibility, the contrast-to-noise ratio (CNR) was calculated analyzing B-mode images by positioning region of interests in correspondence of needle tip and liver parenchyma. RESULTS: Needle tip echogenicity was significantly higher in group B where the needle tip was modified compared to control group A (p value = 0.014). CNR, considered to objectively evaluate differences among needle tip echogenicity, was significantly higher in group B with respect to control group A (p value = 0.018). CONCLUSIONS: The proposed method, scrubbing a 22 gauge commercially available needle tip with a scalpel blade, represents an effective technique to improve needle visibility during US-guided punctures of the liver.


Asunto(s)
Agujas , Ultrasonografía Intervencional , Humanos , Hígado/diagnóstico por imagen , Hígado/cirugía , Fantasmas de Imagen , Estudios Retrospectivos , Ultrasonografía Intervencional/métodos
16.
Tomography ; 7(4): 688-696, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34842836

RESUMEN

RATIONALE AND OBJECTIVES: The aim of our retrospective study was to assess the safety and feasibility of cryoablation in high-risk patients with complex chest neoplastic lesions. MATERIALS AND METHODS: Twenty patients with complex chest malignancies, both primary and secondary, located in the mediastinum, lung, and chest wall, underwent percutaneous CT-guided cryoablation treatments. Procedural success as well as complications were evaluated. RESULTS: A total of 24 neoplastic lesions were treated (mean diameter: 27 mm; range: 7-54 mm). Technical success was obtained in all patients, without major complications or intraprocedural death. A pneumothorax not requiring a drainage tube placement was registered in 50% of patients, while 3/24 patients had a grade 3 pneumothorax requiring a chest tube placement. CONCLUSION: Percutaneous CT-guided cryoablation seems a safe and feasible treatment for complex thoracic lesions.


Asunto(s)
Criocirugía , Neumotórax , Neoplasias Torácicas , Criocirugía/efectos adversos , Humanos , Neumotórax/diagnóstico por imagen , Neumotórax/etiología , Estudios Retrospectivos , Neoplasias Torácicas/diagnóstico por imagen , Neoplasias Torácicas/cirugía , Tomografía Computarizada por Rayos X
17.
Diagnostics (Basel) ; 11(7)2021 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-34359339

RESUMEN

BACKGROUND: This study aims to investigate the correlation between computed tomography (CT) and digital subtraction angiography (DSA) findings in patients affected by acute post-traumatic intraparenchymal renal hemorrhages and evaluate their conservative management with superselective embolization. METHODS: This retrospective multicenter analysis focuses on patients affected by renal bleedings detected by contrast-enhanced CT and treated with superselective endovascular embolization. CT findings were compared to DSA. Embolization procedural data were analyzed and renal function was evaluated before and after the intervention. RESULTS: Twenty-seven patients were retrospectively evaluated in one year. Compared to DSA, CT showed 96.3% diagnostic accuracy in terms of hemorrhage recognition; concerning the type of vascular lesion, there was discrepancy between CT and DSA in five cases. The technical success rate of embolization was 100%, while primary clinical success was 88.9%. The inferior parenchymal third was the most frequent site of renal injury. Microcoils were the most adopted embolics. Renal function did not change significantly before and after embolization. CONCLUSIONS: CT has elevated diagnostic accuracy in detecting post-traumatic intraparenchymal renal hemorrhages; in a small percentage, the type of vascular lesion may differ from the findings observed at DSA. In this scenario, superselective embolization presents high clinical success with a low complication rate.

18.
CVIR Endovasc ; 4(1): 59, 2021 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-34250548

RESUMEN

AIM: To describe a 3 years experience of peripheral arterial embolization with Micro Vascular Plug (MVP) (Medtronic, USA). MATERIALS AND METHODS: The following parameters were investigated: type of vascular injury, anticoagulation therapy at time of procedure, anatomical district, caliper of the target artery, course of the landing zone, additional embolics, technical and clinical success, device related clinical complications. Technical success was defined as complete embolization without deployment of additional embolics after MVP release. Primary clinical success was considered as hemodynamic stability in emergency setting and resolution of the underlying vascular pathology in elective cases; secondary clinical success was considered clinical success after a second embolization session. RESULTS: 116 MVP have been released in 104 patients (67 males and 37 females; mean age 61.3 years). The pullback release technique was adopted in each case. 85 patients were treated in emergent settings while in 19 patients the procedure was scheduled. The overall technical success was 75%. Primary clinical success was 96.1%, secondary clinical success 3% and clinical failure 0.9%. No statistical differences in terms of effectiveness were observed among patients assuming anticoagulation (p-value = 0.6). A straight and longer landing zone were statistically associated with higher technical success compared to curved and shorter ones, (p-values < 0.001 and = 0.048 respectively). MVP-3 and MVP-5 were the most frequently adopted models in this sample, in 29.8% and 49% of the patients respectively. No clinically adverse events directly related to MVP occurred; in 3 cases device migration was registered without clinical complications. CONCLUSION: MVP is a safe and effective embolic agent. While eventual concomitant anticoagulation therapy did not influence the technical outcome, straight course and length of the landing zone are essential parameters to evaluate before deployment.

19.
Tomography ; 7(3): 268-277, 2021 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-34209969

RESUMEN

Most medical devices are routinely recognized on radiological images and described as normal findings in the radiological report, but sometimes they can cause patient access to the emergency department. Multiple possible complications have been described and most of them require prompt recognition by radiologists for proper clinical management. This commentary proposes a systematic approach to radiological reporting of the most common emergent complications related to medical devices with the intent to avoid the omission of important findings in the final radiological report.


Asunto(s)
Radiología , Servicio de Urgencia en Hospital , Humanos , Radiografía , Radiólogos
20.
Radiol Med ; 126(7): 1007-1016, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33890201

RESUMEN

PURPOSE: Aim of this study was to identify preprocedural parameters, which may predict the application of a complex IVC filter retrieval technique and estimate the procedural outcome by applying two dedicated score systems. MATERIALS AND METHODS: In this retrospective multicenter analysis, data concerning patient, filter and procedure characteristics were retrieved from January 2018 to March 2020. Patients were evaluated according to the retrieval technique (standard vs. complex) and the procedural outcome (success vs. failure). Significant differences among these groups were evaluated, and two score systems were developed to predict the application of a complex retrieval technique and the procedural outcome. RESULTS: One hundred and sixteen IVC filters were retrieved in 116 patients. In 98 subjects, the filter was retrieved with a standard procedure (Standard group, 84.5% vs. Complex group, 15.5%), while in 106 patients the procedure was successful (Success group, 91.4% vs. Failure group, 8.6%). Statistically significant differences were noted in terms of embedded filter hook, filter apex tilt, angle between filter axis and IVC, caval wall penetration, dwelling time and procedural time. Two score 0-5 points to predict the need for a complex retrieval technique and the procedural outcome were developed, with a prognostic accuracy of 88.8% and 91.4%, respectively. CONCLUSION: Significant differences were appreciable analyzing the sample data comparing both the retrieval technique applied and the procedural outcome. Two predictive scores were developed to assess the need for applying a complex retrieval technique and to estimate the procedural outcome.


Asunto(s)
Remoción de Dispositivos/métodos , Puntaje de Propensión , Filtros de Vena Cava/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...